Yuichi Okata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuichi Okata has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Yuko Bitoh
Division of Pediatric Surgery, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
18 shared publicationsKosaku Maeda
Department of Pediatric Surgery, Kobe Children's Hospital, Kobe, Japan
10 shared publicationsHarunori Miyauchi
Division of Pediatric Surgery, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
9 shared publicationsAkiko Yokoi
Department of Pediatric Surgery, Kobe Children's Hospital, 1-6-7 Minatojima-cho, Chuo-ku, Kobe, 650-0047, Japan
8 shared publicationsChieko Hisamatsu
Department of Pediatric Surgery, Kobe Children's Hospital, 1-6-7 Minatojima-cho, Chuo-ku, Kobe, 650-0047, Japan
6 shared publicationsEiji Nishijima
Department of Pediatric Surgery, Takatsuki Hospital, Takatsuki, Japan
6 shared publications
Latest Publications
- Open Access
- 2 October 2025
- Published by Springer Nature in Pediatric Surgery International
- Vol. 41 (1) , 1-9
Initial adaptation and surgical performance of the hinotori™ robotic system among pediatric surgeons with minimal robotic exposure
Purpose: This study aimed to evaluate the ability of the hinotori™ system to mitigate technical and ergonomic challenges in pediatric laparoscopy by comparing usability, suturing precision, and stress responses with that of conventional laparoscopy in a simulated infant abdomen. Methods: Ten pediatric surgeons with limited robotic experience performed peg transfer and suturing in a 1,400-mL box model simulating a 6-month-old abdomen, using robotic-assisted (Robo) and laparoscopic (Lap) approaches in a crossover design. Performance was assessed using the Fundamentals of Laparoscopic Surgery (FLS) score and the A-Lap Mini platform, which evaluates suturing accuracy across five domains. Physiological stress (heart rate and salivary amylase levels) and subjective fatigue (Chalder Fatigue Scale and visual analog scale) were recorded. Results: Peg-transfer FLS scores were comparable between Robo and Lap (497.5 vs 531), with progressive improvement across Robo trials. Robotic suturing demonstrated greater air-leak resistance, smaller wound openings, and fewer internal collisions. Stress and fatigue indices did not differ significantly, although trends favored Robo. Conclusion: Pediatric surgeons with minimal robotic experience achieved higher suturing precision using hinotori™, suggesting intuitive usability and potential safety-related benefits in training. Owing to the small sample size, absence of resident-level validation, and lack of formal performance–stress correlation, confirmation in larger cohorts is warranted.
- 2 October 2025
- Published by Springer Nature in Pediatric Surgery International
- Vol. 41 (1) , 1-9
Open AccessInitial adaptation and surgical performance of the hinotori™ robotic system among pediatric surgeons with minimal robotic exposure
Purpose: This study aimed to evaluate the ability of the hinotori™ system to mitigate technical and ergonomic challenges in pediatric laparoscopy by comparing usability, suturing precision, and stress responses with that of conventional laparoscopy in a simulated infant abdomen. Methods: Ten pediatric surgeons with limited robotic experience performed peg transfer and suturing in a 1,400-mL box model simulating a 6-month-old abdomen, using robotic-assisted (Robo) and laparoscopic (Lap) approaches in a crossover design. Performance was assessed using the Fundamentals of Laparoscopic Surgery (FLS) score and the A-Lap Mini platform, which evaluates suturing accuracy across five domains. Physiological stress (heart rate and salivary amylase levels) and subjective fatigue (Chalder Fatigue Scale and visual analog scale) were recorded. Results: Peg-transfer FLS scores were comparable between Robo and Lap (497.5 vs 531), with progressive improvement across Robo trials. Robotic suturing demonstrated greater air-leak resistance, smaller wound openings, and fewer internal collisions. Stress and fatigue indices did not differ significantly, although trends favored Robo. Conclusion: Pediatric surgeons with minimal robotic experience achieved higher suturing precision using hinotori™, suggesting intuitive usability and potential safety-related benefits in training. Owing to the small sample size, absence of resident-level validation, and lack of formal performance–stress correlation, confirmation in larger cohorts is warranted.
- Open Access
- 23 July 2025
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 196, 112499
Preclinical assessment of agreement between optical frequency domain imaging and pathology in rabbit subglottic mucosal lesions
- 23 July 2025
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 196, 112499
Open AccessPreclinical assessment of agreement between optical frequency domain imaging and pathology in rabbit subglottic mucosal lesions
- Open Access
- 1 January 2025
- Published by Wiley in Pediatrics International
- Vol. 67 (1) , e70271
Initial pediatric robot‐assisted adrenalectomy using the hinotori Surgical Robot System
- 1 January 2025
- Published by Wiley in Pediatrics International
- Vol. 67 (1) , e70271
Open AccessInitial pediatric robot‐assisted adrenalectomy using the hinotori Surgical Robot System
- Open Access
- 27 July 2024
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-9
Evaluation of the hinotori™ Surgical Robot System for accurate suturing in small cavities
The hinotori™ Surgical Robot System (hinotori™, Medicaroid, Kobe, Japan) is increasingly being utilized primarily in urology and adult surgery; however, data on its application in pediatric surgery are lacking. This preclinical study aimed to evaluate the limitations of this system for accurate suturing in small cavities designed for pediatric and neonatal applications. Two trained operators performed simple ligature sutures (easy task [ET]) and hepaticojejunostomy sutures (difficult task [DT]) within five differently sized boxes, ranging from 5123 to 125 mL. The suture time, number of internal and external instrument/instrument collisions, instrument/box collisions, and suture accuracy were evaluated. The suture accuracy was assessed using the A-Lap Mini endoscopic surgery skill assessment system. As a result, an increase in the number of collisions and extended suturing times were observed in boxes with volumes smaller than 215 mL. Despite these variations, there were no significant differences between the boxes, and all tasks were precisely performed in all boxes (p = 0.10 for the ET and p = 1.00 for the DT). These findings demonstrate the capability of the hinotori™ system to perform precise suturing techniques within tightly confined simulated neonatal cavities as small as 125 mL. To advance the integration of pediatric robotic surgery utilizing the hinotori™ system, additional trials comparing it with conventional laparoscopic and thoracoscopic techniques using pediatric and animal models are necessary to assess its clinical safety and applicability.
- 27 July 2024
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-9
Open AccessEvaluation of the hinotori™ Surgical Robot System for accurate suturing in small cavities
The hinotori™ Surgical Robot System (hinotori™, Medicaroid, Kobe, Japan) is increasingly being utilized primarily in urology and adult surgery; however, data on its application in pediatric surgery are lacking. This preclinical study aimed to evaluate the limitations of this system for accurate suturing in small cavities designed for pediatric and neonatal applications. Two trained operators performed simple ligature sutures (easy task [ET]) and hepaticojejunostomy sutures (difficult task [DT]) within five differently sized boxes, ranging from 5123 to 125 mL. The suture time, number of internal and external instrument/instrument collisions, instrument/box collisions, and suture accuracy were evaluated. The suture accuracy was assessed using the A-Lap Mini endoscopic surgery skill assessment system. As a result, an increase in the number of collisions and extended suturing times were observed in boxes with volumes smaller than 215 mL. Despite these variations, there were no significant differences between the boxes, and all tasks were precisely performed in all boxes (p = 0.10 for the ET and p = 1.00 for the DT). These findings demonstrate the capability of the hinotori™ system to perform precise suturing techniques within tightly confined simulated neonatal cavities as small as 125 mL. To advance the integration of pediatric robotic surgery utilizing the hinotori™ system, additional trials comparing it with conventional laparoscopic and thoracoscopic techniques using pediatric and animal models are necessary to assess its clinical safety and applicability.
- 24 January 2024
- Vol. 69 (4) , E122-E128
Significance of Serum Leucine-rich Alpha-2 Glycoprotein as a Diagnostic Marker in Pediatric Inflammatory Bowel Disease
Serum leucine-rich alpha-2 glycoprotein (LRG) has been utilized for adult inflammatory bowel disease (IBD); however, its efficacy in pediatric IBD remains unknown. The aim of this study was to compare the diagnostic accuracy of serum LRG for pediatric IBD with that of current inflammatory markers, erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP). This retrospective case-control study included pediatric patients, aged <16 years, who underwent colonoscopy and/or esophagogastroduodenoscopy between April 2017 and March 2022. All eligible patients were divided into two groups: patients with IBD, diagnosed with ulcerative colitis and Crohn’s disease, and non-IBD controls. The optimal cut-off value of serum LRG for IBD diagnosis was determined from receiver operating characteristic analysis, and diagnostic accuracy of serum LRG was compared to serum ESR and CRP. A total of 53 patients (24 with IBD and 29 non-IBD controls) met the inclusion criteria. The cut-off value of serum LRG for IBD diagnosis was determined to be 19.5 μg/ml. At this cut-off value, serum LRG had a positive predictive value (PPV) of 0.80 and negative predictive value (NPV) of 0.88. In contrast, PPV and NPV were 0.78 and 0.70 for serum ESR and 0.82 and 0.72 for serum CRP, respectively. Serum LRG can be a potential diagnostic marker for pediatric IBD, with higher diagnostic accuracy than that of the conventional serum markers ESR and CRP.
- 24 January 2024
- Vol. 69 (4) , E122-E128
Significance of Serum Leucine-rich Alpha-2 Glycoprotein as a Diagnostic Marker in Pediatric Inflammatory Bowel Disease
Serum leucine-rich alpha-2 glycoprotein (LRG) has been utilized for adult inflammatory bowel disease (IBD); however, its efficacy in pediatric IBD remains unknown. The aim of this study was to compare the diagnostic accuracy of serum LRG for pediatric IBD with that of current inflammatory markers, erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP). This retrospective case-control study included pediatric patients, aged <16 years, who underwent colonoscopy and/or esophagogastroduodenoscopy between April 2017 and March 2022. All eligible patients were divided into two groups: patients with IBD, diagnosed with ulcerative colitis and Crohn’s disease, and non-IBD controls. The optimal cut-off value of serum LRG for IBD diagnosis was determined from receiver operating characteristic analysis, and diagnostic accuracy of serum LRG was compared to serum ESR and CRP. A total of 53 patients (24 with IBD and 29 non-IBD controls) met the inclusion criteria. The cut-off value of serum LRG for IBD diagnosis was determined to be 19.5 μg/ml. At this cut-off value, serum LRG had a positive predictive value (PPV) of 0.80 and negative predictive value (NPV) of 0.88. In contrast, PPV and NPV were 0.78 and 0.70 for serum ESR and 0.82 and 0.72 for serum CRP, respectively. Serum LRG can be a potential diagnostic marker for pediatric IBD, with higher diagnostic accuracy than that of the conventional serum markers ESR and CRP.
- 6 January 2024
- Published by Wiley in Journal of Intellectual Disability Research
- Vol. 68 (4) , 317-324
Cholelithiasis prevalence and risk factors in individuals with severe or profound intellectual and motor disabilities
BackgroundThe prevalence and risk factors of cholelithiasis in individuals with severe or profound intellectual and motor disabilities (SPIMD) are poorly characterised. Thus, we aimed to investigate the prevalence and risk determinants of cholelithiasis in a cohort with SPIMD under medical care in a residential facility.MethodsWe categorised 84 patients in a residential hospital for persons with SPIMD into groups: those with (Group CL) and without (Group N) cholelithiasis. Gallstones were detected via computed tomography, ultrasonography or both. We evaluated gastrostomy status, nutritional and respiratory support, constipation, and bladder and kidney stones. Data were significantly analysed using univariate and multivariate logistic regression analyses.ResultsThe prevalence rate of cholelithiasis in our SPIMD cohort was 27%. There were no significant differences in sex, age, weight, height, or Gross Motor Function Classification System between the two groups. However, more patients received enteral nutrition (39.13% vs. 6.56%; P = 0.000751) and were on ventilator support (56.52% vs. 19.67%; P = 0.00249) in Group CL than in Group N. Enteral nutrition [odds ratio (OR) 10.4, 95% confidence interval (CI) 1.98-54.7] and ventilator support (OR 20.0, 95% CI 1.99-201.0) were identified as independent risk factors for the prevalence of cholelithiasis in patients with SPIMD.ConclusionsPatients with SPIMD demonstrated an increased prevalence of cholelithiasis, with a notable association between nutritional tonic use and respiratory support. Therefore, to emphasise the need for proactive screening, it is crucial to devise diagnostic and therapeutic strategies specific to patients with SPIMD. Further investigation is essential to validate our findings and explore causative factors.
- 6 January 2024
- Published by Wiley in Journal of Intellectual Disability Research
- Vol. 68 (4) , 317-324
Cholelithiasis prevalence and risk factors in individuals with severe or profound intellectual and motor disabilities
BackgroundThe prevalence and risk factors of cholelithiasis in individuals with severe or profound intellectual and motor disabilities (SPIMD) are poorly characterised. Thus, we aimed to investigate the prevalence and risk determinants of cholelithiasis in a cohort with SPIMD under medical care in a residential facility.MethodsWe categorised 84 patients in a residential hospital for persons with SPIMD into groups: those with (Group CL) and without (Group N) cholelithiasis. Gallstones were detected via computed tomography, ultrasonography or both. We evaluated gastrostomy status, nutritional and respiratory support, constipation, and bladder and kidney stones. Data were significantly analysed using univariate and multivariate logistic regression analyses.ResultsThe prevalence rate of cholelithiasis in our SPIMD cohort was 27%. There were no significant differences in sex, age, weight, height, or Gross Motor Function Classification System between the two groups. However, more patients received enteral nutrition (39.13% vs. 6.56%; P = 0.000751) and were on ventilator support (56.52% vs. 19.67%; P = 0.00249) in Group CL than in Group N. Enteral nutrition [odds ratio (OR) 10.4, 95% confidence interval (CI) 1.98-54.7] and ventilator support (OR 20.0, 95% CI 1.99-201.0) were identified as independent risk factors for the prevalence of cholelithiasis in patients with SPIMD.ConclusionsPatients with SPIMD demonstrated an increased prevalence of cholelithiasis, with a notable association between nutritional tonic use and respiratory support. Therefore, to emphasise the need for proactive screening, it is crucial to devise diagnostic and therapeutic strategies specific to patients with SPIMD. Further investigation is essential to validate our findings and explore causative factors.
- Open Access
- 5 March 2023
- Published by Elsevier in Journal of Pediatric Surgery Open
- Vol. 2
Impact of peritoneal lavage temperature during laparotomy in a preterm peritonitis mouse model using cecal slurry
- 5 March 2023
- Published by Elsevier in Journal of Pediatric Surgery Open
- Vol. 2
Open AccessImpact of peritoneal lavage temperature during laparotomy in a preterm peritonitis mouse model using cecal slurry
- 1 January 2023
- Published by Wiley in Pediatrics International
- Vol. 65 (1) , e15569
Laparoscopic Necrosectomy for walled‐off necrosis following necrotizing pancreatitis
- 1 January 2023
- Published by Wiley in Pediatrics International
- Vol. 65 (1) , e15569
Laparoscopic Necrosectomy for walled‐off necrosis following necrotizing pancreatitis
- Open Access
- 3 August 2022
- Published by Elsevier in Journal of Pediatric Surgery Case Reports
- Vol. 85
A primary appendiceal Burkitt lymphoma mimicking appendiceal abscess
- 3 August 2022
- Published by Elsevier in Journal of Pediatric Surgery Case Reports
- Vol. 85
Open AccessA primary appendiceal Burkitt lymphoma mimicking appendiceal abscess