Susan K. Frazier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Susan K. Frazier has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Jeanne Widener
Ohio State University College of Nursing, Columbus, Ohio
2 shared publicationsKathleen S. Stone
Ohio State University College of Nursing, Columbus, Ohio
2 shared publicationsLauren Pender
Ohio State University College of Nursing, Columbus, Ohio
2 shared publicationsAllison R. Jones
Department of Acute, Chronic & Continuing Care, School of Nursing, University of Alabama at Birmingham, NB 543, 1720 2nd Avenue South, Birmingham, AL 35294-1210, USA
1 shared publication- Andrew Bugajski
Lakeland Regional Health, Lakeland, FL, United States
1 shared publication Carolyn Carle
University of Kentucky College of Nursing, Lexington, Ky (skf, dm) and Ohio State University College of Nursing, Columbus, Ohio (kss, rs, cc, lp, jw, hb)
1 shared publication
Latest Publications
- 1 September 2017
- Published by Elsevier in Critical Care Nursing Clinics of North America
- Vol. 29 (3) , 271-290
Adverse Reactions to Transfusion of Blood Products and Best Practices for Prevention
- 1 September 2017
- Published by Elsevier in Critical Care Nursing Clinics of North America
- Vol. 29 (3) , 271-290
Adverse Reactions to Transfusion of Blood Products and Best Practices for Prevention
- 1 December 2014
- Published by Wolters Kluwer Health in Journal of the American Association of Nurse Practitioners
- Vol. 26 (12) , 681-688
Predictors of perceived higher quality patient-provider communication in patients with rheumatoid arthritis
Of contextual factors for higher quality patient-provider communication. Data sources: A validated, self-report scale measured patient perception of quality of patient-provider communication. Data were analyzed using chi-square tests of association, two-sample t-tests, and multiple linear regression. Conclusions/implications for practice: There were no differences in external environmental or internal personal factors between those who perceived higher and lower quality of communication. From the linear regression, patients with fewer years of education (p = .008), those taking a greater number of RA medications (p = .03), and those living in an urban area (p = .04) perceived the quality of communication more positively. The findings from this study suggest that contextual factors (years of education, residence, and the number of medications) may affect RA patient perception of the quality of patient-provider communication. This underscores the need for development of appropriate and effective interventions to improve communication and optimize RA patient outcomes....
- 1 December 2014
- Published by Wolters Kluwer Health in Journal of the American Association of Nurse Practitioners
- Vol. 26 (12) , 681-688
Predictors of perceived higher quality patient-provider communication in patients with rheumatoid arthritis
Of contextual factors for higher quality patient-provider communication. Data sources: A validated, self-report scale measured patient perception of quality of patient-provider communication. Data were analyzed using chi-square tests of association, two-sample t-tests, and multiple linear regression. Conclusions/implications for practice: There were no differences in external environmental or internal personal factors between those who perceived higher and lower quality of communication. From the linear regression, patients with fewer years of education (p = .008), those taking a greater number of RA medications (p = .03), and those living in an urban area (p = .04) perceived the quality of communication more positively. The findings from this study suggest that contextual factors (years of education, residence, and the number of medications) may affect RA patient perception of the quality of patient-provider communication. This underscores the need for development of appropriate and effective interventions to improve communication and optimize RA patient outcomes....
- 1 April 2008
- Published by SAGE Publications in Biological Research For Nursing
- Vol. 9 (4) , 301-310
Autonomic Tone in Medical Intensive Care Patients Receiving Mechanical Ventilation and During a CPAP Weaning Trial
Mechanical ventilator support and the resumption of spontaneous ventilation or weaning create significant alterations in alveolar and intrathoracic pressure that influence thoracic blood volume and flow. Compensatory autonomic tone alterations occur to ensure adequate tissue oxygen delivery, but autonomic responses may produce cardiovascular dysfunction with subsequent weaning failure. The authors describe autonomic responses of critically ill patients (n = 43) during a 24-hr period of mechanical ventilatory support and during the 24 hr that included their initial spontaneous breathing trial using continuous positive airway pressure. Nearly two thirds of these patients demonstrated abnormal autonomic function and this dysfunction was more severe in those patients who were unable to sustain spontaneous ventilation (n = 15). With further systematic study, autonomic responses may be useful in the identification of patients who are likely to develop cardiac dysfunction with the resumption of spontaneous breathing.
- 1 April 2008
- Published by SAGE Publications in Biological Research For Nursing
- Vol. 9 (4) , 301-310
Autonomic Tone in Medical Intensive Care Patients Receiving Mechanical Ventilation and During a CPAP Weaning Trial
Mechanical ventilator support and the resumption of spontaneous ventilation or weaning create significant alterations in alveolar and intrathoracic pressure that influence thoracic blood volume and flow. Compensatory autonomic tone alterations occur to ensure adequate tissue oxygen delivery, but autonomic responses may produce cardiovascular dysfunction with subsequent weaning failure. The authors describe autonomic responses of critically ill patients (n = 43) during a 24-hr period of mechanical ventilatory support and during the 24 hr that included their initial spontaneous breathing trial using continuous positive airway pressure. Nearly two thirds of these patients demonstrated abnormal autonomic function and this dysfunction was more severe in those patients who were unable to sustain spontaneous ventilation (n = 15). With further systematic study, autonomic responses may be useful in the identification of patients who are likely to develop cardiac dysfunction with the resumption of spontaneous breathing.
- 1 March 2008
- Published by Elsevier in Nursing Clinics of North America
- Vol. 43 (1) , 1-15
Cardiovascular Effects of Mechanical Ventilation and Weaning
- 1 March 2008
- Published by Elsevier in Nursing Clinics of North America
- Vol. 43 (1) , 1-15
Cardiovascular Effects of Mechanical Ventilation and Weaning
- 1 March 2008
- Published by Wolters Kluwer Health in Journal of Cardiovascular Nursing
- Vol. 23 (2) , 103-104
Foreword
- 1 March 2008
- Published by Wolters Kluwer Health in Journal of Cardiovascular Nursing
- Vol. 23 (2) , 103-104
Foreword
- 1 March 2008
- Published by Wolters Kluwer Health in Journal of Cardiovascular Nursing
- Vol. 23 (2) , 113-121
Pulmonary Artery Catheters
Since 1970, pulmonary artery catheters (PACs) have been used in clinical practice to monitor the hemodynamic status of critically ill and injured patients. This technology was introduced and commercialized without considerable testing to determine safety and efficacy. After years of common clinical use, investigators identified potential increases in mortality associated with PAC use. For the past decade, investigators have studied various patient populations to elucidate the safety and efficacy of the PAC. This article reviews the historical context of PAC use, findings from recent clinical trials intended to determine safety and efficacy, issues with reliability and validity of PAC use, and complications associated with PAC use. Data from recent clinical trials do not support routine use of PACs, and the authors suggest that PAC-guided therapy should be the focus of study in future trials.
- 1 March 2008
- Published by Wolters Kluwer Health in Journal of Cardiovascular Nursing
- Vol. 23 (2) , 113-121
Pulmonary Artery Catheters
Since 1970, pulmonary artery catheters (PACs) have been used in clinical practice to monitor the hemodynamic status of critically ill and injured patients. This technology was introduced and commercialized without considerable testing to determine safety and efficacy. After years of common clinical use, investigators identified potential increases in mortality associated with PAC use. For the past decade, investigators have studied various patient populations to elucidate the safety and efficacy of the PAC. This article reviews the historical context of PAC use, findings from recent clinical trials intended to determine safety and efficacy, issues with reliability and validity of PAC use, and complications associated with PAC use. Data from recent clinical trials do not support routine use of PACs, and the authors suggest that PAC-guided therapy should be the focus of study in future trials.
- 1 November 2006
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 15 (6) , 580-593
Hemodynamic Changes During Discontinuation of Mechanical Ventilation in Medical Intensive Care Unit Patients
• Background Cardiac dysfunction can prevent successful discontinuation of mechanical ventilation. Critically ill patients may have undetected cardiac disease, and cardiac dysfunction can be produced or exacerbated by underlying pathophysiology. • Objective To describe and compare hemodynamic function and cardiac rhythm during baseline mechanical ventilation with function and rhythm during a trial of continuous positive airway pressure in medical intensive care patients. • Methods A convenience sample of 43 patients (53% men; mean age 51.1 years) who required mechanical ventilation were recruited for this pilot study. Cardiac output, stroke volume, arterial blood pressure, heart rate, cardiac rhythm, and plasma catecholamine levels were measured during mechanical ventilation and during a trial of continuous positive airway pressure. • Results One third of the patients had difficulty discontinuing mechanical ventilation. Successful patients had significantly increased cardiac output and stroke volume without changes in heart rate or arterial pressure during the trial of continuous positive airway pressure. Unsuccessful patients had no significant changes in cardiac output, stroke volume, or heart rate but had a significant increase in mean arterial pressure. The 2 groups of patients also had different patterns in ectopy. Concurrently, catecholamine concentrations decreased in the successful patients and significantly increased in the unsuccessful patients during the trial. • Conclusions Patterns of cardiac function and plasma catecholamine levels differed between patients who did or did not achieve spontaneous ventilation with a trial of continuous positive airway pressure. Cardiac function must be systematically considered before and during the return to spontaneous ventilation to optimize the likelihood of success.
- 1 November 2006
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 15 (6) , 580-593
Hemodynamic Changes During Discontinuation of Mechanical Ventilation in Medical Intensive Care Unit Patients
• Background Cardiac dysfunction can prevent successful discontinuation of mechanical ventilation. Critically ill patients may have undetected cardiac disease, and cardiac dysfunction can be produced or exacerbated by underlying pathophysiology. • Objective To describe and compare hemodynamic function and cardiac rhythm during baseline mechanical ventilation with function and rhythm during a trial of continuous positive airway pressure in medical intensive care patients. • Methods A convenience sample of 43 patients (53% men; mean age 51.1 years) who required mechanical ventilation were recruited for this pilot study. Cardiac output, stroke volume, arterial blood pressure, heart rate, cardiac rhythm, and plasma catecholamine levels were measured during mechanical ventilation and during a trial of continuous positive airway pressure. • Results One third of the patients had difficulty discontinuing mechanical ventilation. Successful patients had significantly increased cardiac output and stroke volume without changes in heart rate or arterial pressure during the trial of continuous positive airway pressure. Unsuccessful patients had no significant changes in cardiac output, stroke volume, or heart rate but had a significant increase in mean arterial pressure. The 2 groups of patients also had different patterns in ectopy. Concurrently, catecholamine concentrations decreased in the successful patients and significantly increased in the unsuccessful patients during the trial. • Conclusions Patterns of cardiac function and plasma catecholamine levels differed between patients who did or did not achieve spontaneous ventilation with a trial of continuous positive airway pressure. Cardiac function must be systematically considered before and during the return to spontaneous ventilation to optimize the likelihood of success.