TCTai-Yuan Chuang

Tai-Yuan Chuang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tai-Yuan Chuang has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Arthroscopic T-shaped biceps tenotomy decreased risk of Popeye deformity compared to traditional biceps tenotomy

    by Yen-Wei Huang, Pu-Kuang Wang, Shen-Wu Hung, Yu-Pin Chen, Wei-Chun Chang, Yi-Jie Kuo, Tai-Yuan Chuang

  • Open Access

    Comparing the Prognostic Roles of Red Blood Cell Volume Distribution Width, Neutrophil–Lymphocyte Ratio, and Platelet–Lymphocyte Ratio for Predicting Mortality after Hip Fracture in the Geriatric Population (Preprint)

    by Yu-Hsiang Su, Yen-Wei Huang, Shu-Wei Huang, Yi-Jie Kuo, Tai-Yuan Chuang, Yu-Pin Chen

    BACKGROUND Hip fractures have adverse effects on older adults, often resulting in reduced functional independence, increased social costs, morbidity, and an elevated risk of mortality within 1 year after surgery. Prognostic markers such as red blood cell volume distribution width (RDW), the neutrophil–lymphocyte ratio (NLR), and the platelet–lymphocyte ratio (PLR) have been used to predict outcomes following hip fracture surgery; however, their prediction accuracy has varied across studies. OBJECTIVE This study aims to compare the prognostic accuracy of RDW, NLR, and PLR in predicting the mortality of older adults after hip fracture surgery. METHODS This study enrolled 469 patients who underwent hip fracture surgery and were followed up for 1 year at a single tertiary medical center from December 2018 to May 2022. The patients’ preoperative RDW, NLR, and PLR levels were measured, and data on their clinical characteristics were collected. Receiver operating characteristic (ROC) curves and areas under the curve (AUCs) were used to assess the predictive accuracy of these markers for 1-month, 3-month, and 1-year mortality. RESULTS Among the patients, the mean age was 81.2 years, and 2.6%, 4.1%, and 13.9% died within 1 month, 3 months, and 1 year after surgery, respectively. RDW, NLR, and PLR were nonsignificant predictors of 1-month mortality, but RDW was the sole significant predictor of 3-month and 1-year mortality. The cutoff values for RDW were 15.05% and 13.65% for 3-month and 1-year mortality, respectively. Among the patients aged 60–80 years, RDW was a significant predictor of mortality following hip fracture surgery (AUC: 1 month, 0.83; 3 month, 0.86). However, for the patients aged >80 years, all three markers were nonsignificant predictors. CONCLUSIONS RDW was a robust prognostic factor that outperformed NLR and PLR in predicting the mortality of patients aged >60 years who underwent hip fracture surgery. Furthermore, the predictive accuracy of RDW was even higher for 1-month and 3-month mortality of patients aged 60–80 years who underwent hip fracture surgery.

  • Open Access

    Correction: Preoperative handgrip strength can predict early postoperative shoulder function in patients undergoing arthroscopic rotator cuf repair

    by Yu-Cheng Liu, Shu-Wei Huang, Christopher R. Adams, Chung-Ying Lin, Yu-Pin Chen, Yi-Jie Kuo, Tai-Yuan Chuang

  • Open Access

    Preoperative handgrip strength can predict early postoperative shoulder function in patients undergoing arthroscopic rotator cuff repair

    by Yu-Cheng Liu, Shu-Wei Huang, Christopher R. Adams, Chung-Ying Lin, Yu-Pin Chen, Yi-Jie Kuo, Tai-Yuan Chuang

    Background: Rotator cuff tears (RCTs) are a common musculoskeletal disorder, and arthroscopic rotator cuff repair (ARCR) is widely performed for tendon repair. Handgrip strength correlates with rotator cuff function; however, whether preoperative grip strength can predict functional outcomes in patients undergoing ARCR remains unknown. This study aimed to investigate the correlation between preoperative grip strength and postoperative shoulder function following ARCR. Methods: A total of 52 patients with full-thickness repairable RCTs were prospectively enrolled. Baseline parameters, namely patient characteristics and intraoperative findings, were included for analysis. Postoperative shoulder functional outcomes were assessed using the Quick Disabilities of the Arm, Shoulder, and Hand (QDASH) questionnaire and Constant–Murley scores (CMSs). Patients were followed up and evaluated at three and six months after ARCR. The effects of baseline parameters on postoperative outcomes were measured using generalized estimating equations. Results: At three and six months postoperatively, all clinical outcomes evaluated exhibited significant improvement from baseline following ARCR. Within 6 months postoperatively, higher preoperative grip strength was significantly correlated with higher CMSs (β = 0.470, p = 0.022), whereas increased numbers of total suture anchors were significantly correlated with decreased CMSs (β = − 4.361, p = 0.03). Higher body mass index was significantly correlated with higher postoperative QDASH scores (β = 1.561, p = 0.03) during follow-up. Conclusions: Higher baseline grip strength predicts more favorable postoperative shoulder function following ARCR. A preoperative grip strength test in orthopedic clinics may serve as a predictor for postoperative shoulder functional recovery in patients undergoing ARCR.


  • Open Access

    Higher Charlson Comorbidity Index is a Risk Factor for Hip Fracture in Older Adults at Lower Temperatures: A Cross-sectional Study (Preprint)

    by Ming-Hsiu Chiang, Yi-Jie Kuo, Shu-Wei Huang, Duy Nguyen Anh Tran, Tai-Yuan Chuang, Chung-Ying Lin, Yu-Pin Chen

    BACKGROUND The incidence of hip fractures is increasing, and there have been reports linking cold weather to a higher risk of fractures. OBJECTIVE The study aimed to evaluate clinical variables in hip fracture patients who may predispose them to such fractures under different temperatures. METHODS This is a cross-sectional study conducted at a single medical center, enrolling older adults (≥60 years) who had experienced a hip fracture. Comprehensive clinical histories and detailed information regarding each patient's hip fracture were obtained. All meteorological data were extracted from the Taiwan Central Weather Bureau database. Multiple clinical parameters that may have a close connection with the temperature at which the hip fracture occurred were screened. Statistical analysis involved using the Pearson correlation test or the independent Student’s t-test, followed by generalized estimating equation analysis. RESULTS The cohort comprised 506 older adults with hip fractures. Initial univariate analysis revealed that a history of past cerebrovascular accidents, Charlson Comorbidity Index, patient age, and preinjury Barthel Index were significantly related to the temperature at which the hip fractures occurred. The generalized estimating equation analysis indicated that only the Charlson Comorbidity Index had a considerably inverse association with temperature. This finding suggests that for older adults with a higher Charlson Comorbidity Index, hip fractures tend to occur at lower temperatures, and vice versa. CONCLUSIONS Comorbidities are the only clinical concern that predisposes older adults to hip fracture under colder temperatures. This epidemiological finding could guide future patient education and hip fracture prevention programs. CLINICALTRIAL TMU-JIRB N201709053

  • Open Access

    Wearable Motion Sensor Device to Facilitate Rehabilitation in Patients With Shoulder Adhesive Capsulitis: Pilot Study to Assess Feasibility

    by Yu-Pin Chen, Chung-Ying Lin, Ming-Jr Tsai, Tai-Yuan Chuang, Oscar Kuang-Sheng Lee

    Background: Adhesive capsulitis (AC) of the shoulder is a common disorder that painfully reduces the shoulder range of motion (ROM) among middle-aged individuals. Although physical therapy with home-based exercises is widely advised to restore ROM in the treatment of AC, clinical results vary owing to inconsistent patient compliance. Objective: In this study, we aimed to verify the feasibility of a treatment model that involves applying a wearable motion sensor device to assist patients conduct home-based exercises to improve training compliance and the accuracy of exercises, with the ultimate goal of improving the functional recovery of patients with AC. Methods: The motion sensor device was comprised of inertial measurement unit–based sensors and mobile apps for patients and physicians, offering shoulder mobility tracing, home-based exercise support, and progress monitoring. The interrater reliability of shoulder mobility measurement using the motion sensor device on 10 healthy participants and 15 patients with AC was obtained using an intraclass correlation coefficient analysis and compared with the assessments performed by two highly experienced physicians. A pilot prospective control trial was then carried out to allocate the 15 patients with AC to two groups: home-based exercise group and motion sensor–assisted rehabilitation group. Changes in active and passive shoulder ROM, pain and functional scores, and exercise completion rates were compared between the groups during a treatment period of 3 months. Results: Shoulder ROM, as measured using the motion sensor device, exhibited good to excellent reliability based on the comparison with the measurements of two physicians (intraclass correlation coefficient range, 0.771 to 0.979). Compared with patients with AC in the home-based exercise group, those in the motion sensor–assisted rehabilitation group exhibited better shoulder mobility and functional recovery and a higher exercise completion rate during and after 3 months of rehabilitation. Conclusions: Motion sensor device–assisted home-based rehabilitation for the treatment of AC is a useful treatment model for telerehabilitation that enhances the compliance of patients through training, thus improving functional recovery. This helps overcome important obstacles in physiotherapy at home by providing comprehensible and easily accessible exercise instructions, enhancing compliance, ensuring the correctness of exercise, and monitoring the progress of patients.


  • Open Access

    Wearable Motion Sensor Device to Facilitate Rehabilitation in Patients With Shoulder Adhesive Capsulitis: Pilot Study to Assess Feasibility (Preprint)

    by Yu-Pin Chen, Chung-Ying Lin, Ming-Jr Tsai, Tai-Yuan Chuang, Oscar Kuang-Sheng Lee

    BACKGROUND Adhesive capsulitis (AC) of the shoulder is a common disorder that painfully reduces the shoulder range of motion (ROM) among middle-aged individuals. Although physical therapy with home-based exercises is widely advised to restore ROM in the treatment of AC, clinical results vary owing to inconsistent patient compliance. OBJECTIVE In this study, we aimed to verify the feasibility of a treatment model that involves applying a wearable motion sensor device to assist patients conduct home-based exercises to improve training compliance and the accuracy of exercises, with the ultimate goal of improving the functional recovery of patients with AC. METHODS The motion sensor device was comprised of inertial measurement unit–based sensors and mobile apps for patients and physicians, offering shoulder mobility tracing, home-based exercise support, and progress monitoring. The interrater reliability of shoulder mobility measurement using the motion sensor device on 10 healthy participants and 15 patients with AC was obtained using an intraclass correlation coefficient analysis and compared with the assessments performed by two highly experienced physicians. A pilot prospective control trial was then carried out to allocate the 15 patients with AC to two groups: home-based exercise group and motion sensor–assisted rehabilitation group. Changes in active and passive shoulder ROM, pain and functional scores, and exercise completion rates were compared between the groups during a treatment period of 3 months. RESULTS Shoulder ROM, as measured using the motion sensor device, exhibited good to excellent reliability based on the comparison with the measurements of two physicians (intraclass correlation coefficient range, 0.771 to 0.979). Compared with patients with AC in the home-based exercise group, those in the motion sensor–assisted rehabilitation group exhibited better shoulder mobility and functional recovery and a higher exercise completion rate during and after 3 months of rehabilitation. CONCLUSIONS Motion sensor device–assisted home-based rehabilitation for the treatment of AC is a useful treatment model for telerehabilitation that enhances the compliance of patients through training, thus improving functional recovery. This helps overcome important obstacles in physiotherapy at home by providing comprehensible and easily accessible exercise instructions, enhancing compliance, ensuring the correctness of exercise, and monitoring the progress of patients.

  • Open Access

    Wearable motion sensor device to facilitate compliance with rehabilitation program and functional recovery in patients with shoulder adhesive capsulitis - a pilot study to assess feasibility (Preprint)

    by Yu-Pin Chen, Ming-Jr Tsai, Tai-Yuan Chuang, Oscar Kuang-Sheng Lee

    BACKGROUND Adhesive capsulitis (AC) of the shoulder is a common shoulder disorder that painfully reduces the shoulder range of motion (ROM) among the middle-aged population. Although physical therapy with home-based exercises is widely advised to restore range of motion in the treatment of AC, clinical results vary owing to inconsistent compliance. OBJECTIVE This study aims to verify the feasibility of a treatment model that applies wearable motion sensor device (MSD) to assist home-based exercises to improve training compliance and the accuracy of exercises, with the ultimate goal of improving the functional recovery of AC patients. METHODS The MSD comprised inertial measurement unit-based sensors and mobile apps for patients and physicians, offering shoulder mobility tracing, home-based exercise support and progress monitoring. The inter-rater reliability of shoulder mobility measurement using the MSD on ten healthy participants and 15 AC patients was obtained using intraclass correlation coefficient (ICC) analysis and compared to assessments by two highly experienced physicians. A pilot prospective control trial was then carried out to allocate 15 AC patients to two groups – a home-based exercise (HE) group and a motion sensor-assisted rehabilitation (MAR) group. Changes in active and passive shoulder ROM, pain and functional scores and exercise completion rates were compared between groups for a treatment of three months. RESULTS Shoulder ROM, as measured using the MSD herein, exhibited good to excellent reliability by comparison the measurements made by two physicians (ICC range from 0.771 to 0.979). The AC patients in the MAR group exhibited better shoulder mobility and functional recovery and a higher exercise completion rate than the patients in the HE group during and after three months of rehabilitation CONCLUSIONS This investigation shows that MSD-assisted home-based rehabilitation in the treatment of AC is a useful treatment model for tele-rehabilitation that enhances the compliance of patients with training, improving functional recovery, the overcoming of important obstacles in physiotherapy at home by providing comprehensible and easily accessible exercise instructions, compliance, exercise correctness, and the monitoring of progress.

  • Clinical Results of Hamstring Autografts in Anterior Cruciate Ligament Reconstruction: A Comparison of Femoral Knot/Press‐Fit Fixation and Interference Screw Fixation

    by Wei‐Pin Ho, Chian‐Her Lee, Chang‐Hung Huang, Chih‐Hwa Chen, Tai‐Yuan Chuang

    Purpose: To compare the clinical outcomes of femoral knot/press‐fit anterior cruciate ligament (ACL) reconstruction with conventional techniques using femoral interference screws. Methods: Among patients who underwent arthroscopic ACL reconstruction with hamstring autografts, 73 were treated with either a femoral knot/press‐fit technique (40 patients, group A) or femoral interference screw fixation (33 patients, group B). The clinical results of the 2 groups were retrospectively compared. The inclusion criteria were primary ACL reconstruction in active patients. The exclusion criteria were fractures, multiligamentous injuries, patients undergoing revision, or patients with contralateral ACL‐deficient knees. In the femoral knot/press‐fit technique, semitendinosus and gracilis tendons were prepared as 2 loops with knots. After passage through a bottleneck femoral tunnel, the grafts were fixed with a press‐fit method (grafts' knots were stuck in the bottleneck of the femoral tunnel). A tie with Mersilene tape (Ethicon, Somerville, NJ) over a bone bridge for each tendon loop and an additional bioabsorbable interference screw were used for tibial fixation. Results: The mean follow‐up period was 38 months (range, 24 to 61 months). A significant improvement in knee function and symptoms was reported in most patients, as shown by improved Tegner scores, Lysholm knee scores, and International Knee Documentation Committee assessments ( P < .01). The results of instrumented laxity testing, thigh muscle assessment, and radiologic assessment were clearly improved when compared with the preoperative status ( P < .01). No statistically significant difference in outcomes could be observed between group A and group B ( P = not significant). Conclusions: In this nonrandomized study, femoral knot/press‐fit ACL reconstruction did not appear to provide increased anterior instability compared with that of conventional femoral interference screw ACL reconstruction. Favorable outcomes with regard to knee stability and patient satisfaction were achieved in most of our ACL‐reconstructed patients using femoral knot/press‐fit fixation with hamstring tendon autograft. Level of Evidence: Level IV, therapeutic case series.