ACAntonio E. Castellvi

Antonio E. Castellvi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Antonio E. Castellvi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Indirect Decompression of Lumbar Stenosis With Transpsoas Interbody Cages and Percutaneous Posterior Instrumentation

    by Antonio E. Castellvi, Thomas W. Nienke, German A. Marulanda, Ryan D. Murtagh, Brandon G. Santoni

    The minimally invasive lateral transpsoas retroperitoneal approach to address lumbar stenosis offers advantages to traditional approaches, including sparing of the AP annulus and longitudinal ligament and less risk to the peritoneal contents and retroperitoneal vascular structures. Few studies have presented longitudinal measures of radiographic indirect decompression and relief of pain and restoration of function using the lateral approach to spine fusion. We determined (1) whether radiographic measures suggestive of decompression were achieved after surgery and maintained 1 year after surgery, (2) whether the intervention resulted in sustained improvements in patient-reported outcomes scores 1 year after surgery, and (3) the frequency of pseudarthrosis on CT scans at 1 year after surgery in patients with moderate or severe lumbar stenosis treated with the approach. Between 2008 and 2012, 158 patients were surgically treated to alleviate symptoms associated with degenerative lumbar stenosis, of whom 60 (38%) were treated with lateral lumbar interbody fusion. Of these 60 patients, 36 (60%) received CT scans preoperatively and at 1-year postoperatively and were available for radiographic analysis. Of the 60 treated patients, 16 (27%) were lost to followup before 12 months, leaving the records of 44 patients available for review of patient-reported improvements in pain and return to function. Radiographic increases in disc height, foraminal area, and canal area were measured by one observer on CT scans postoperatively and at 1 year and compared to preoperative values. Patient-reported scores, including VAS pain score and Oswestry Disability Index (ODI), were collected preoperatively and at 3 and 12 months postoperatively. Increases in disc height (67%, p < 0.001), foraminal area (24%–31%, p < 0.001), and canal area (7%, p = 0.011) measured immediately postoperatively were sustained at 1-year followup. VAS pain score and ODI both improved (p < 0.001) at 3 months and were maintained at 1 year. No pseudarthroses were noted radiographically. The lateral transpsoas approach to interbody fusion is capable of sustaining indirect decompression of the neural structures and resolving preoperative claudication and radiculopathy. A larger series of patients with longer followup should be studied to substantiate these early clinical results. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study

    by Brandon G. Santoni, Gerald E. Alexander, Aniruddh Nayak, Andres Cabezas, German A. Marulanda, Ryan Murtagh, Antonio E. Castellvi

    The lateral transpsoas approach to interbody fusion is gaining popularity. Existing literature suggests that perioperative vertebra-related complications include endplate breach owing to aggressive enedplate preparation and poor bone quality. The acute effects of cage subsidence on stabilization and indirect decompression at the affected level are unknown. The purpose of this study was to compare the kinematics and radiographic metrics of indirect decompression in lumbar spines instrumented with laterally placed cages in the presence of inadvertent endplate fracture, which was determined radiographically, to specimens instrumented with lateral cages with intact endplates. Five levels in 5 specimens sustained endplate fracture during lateral cage implantation followed by supplementary fixation (pedicle screw/rod [PSR]: n = 1; anterolateral plate [ALP]: n = 4), as part of a larger laboratory-based study. Range of motion (ROM) in these specimens was compared with 13 instrumented specimens with intact endplates. All specimens were scanned using computed tomography (CT) in the intact, noninstrumented condition and after 2-level cage placement with internal fixation under a 400-N follower load. Changes in disc height, foraminal area, and canal area were measured and compared between specimens with intact endplates and fractured endplates. Subsidence in the single PSR specimen and 4 ALP specimens was 6.5 mm and 4.3 ± 2.7 mm (range: 2.2-8.3 mm), respectively. ROM was increased in the PSR and ALP specimens with endplate fracture when compared with instrumented specimens with intact endplates. In 3 ALP specimens with endplate fracture, ROM in some motion planes increased relative to the intact, noninstrumented spine. These increases in ROM were paralleled by increase in cage translations during cyclic loading (up to 3.3 mm) and an unpredictable radiographic outcome with increases or decreases in posterior disc height, foraminal area, and canal area when compared with instrumented specimens with intact endplates. Endplate fracture and cage subsidence noted radiographically intraoperatively or in the early postoperative period may be indicative of biomechanical instability at the affected level concomitant with a lack of neurologic decompression, which may require revision surgery.


  • Corpectomy with titanium cage reconstruction in the cervical spine

    by Antonio E. Castellvi, Alex Castellvi, Deborah H. Clabeaux


  • Open Access

    Effects of preoperative education on spinal surgery patients

    by Ioannis Papanastassiou, Roberta Anderson, Nicole Barber, Cathleen Conover, Antonio E. Castellvi

    Preoperative patient education (PE) has been used by many institutions to deal with patient anxiety, pain control, and overall satisfaction. Although the literature suggests PE's effectiveness in joint reconstruction, data are missing in spinal surgery. We retrospectively analyzed patients having elective spinal surgery who underwent PE (spine pre-care class) from October 2009 to March 2010. Of the 155 patients surveyed, 77 (49.7%) attended the class whereas 78 (50.3%) did not. Of the participants in the pre-care class, 96% were satisfied with their pain management versus 83% in the control group (P =.02). There was also a trend for better overall satisfaction in the pre-care class group (91% vs 85%; P > .05, multiple regression analysis). Elderly women tend to be less satisfied with pain management and overall treatment. Implementation of PE has had a positive impact on patient satisfaction, especially in terms of pain management.


  • Open Access

    Hybrid dynamic stabilization with posterior spinal fusion in the lumbar spine

    by William R.S. Hudson, John Eric Gee, James B. Billys, Antonio E. Castellvi

    Spinal fusion has been the standard treatment for degenerative disc disease and other degenerative conditions of the spine after failure of nonoperative regimens. Successful instrumented fusions provide immediate stability after decompression and long-term maintenance of correction after reconstruction but also eliminate motion of the segment.