Byung Kook Kwak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Byung Kook Kwak has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Hyung Jin Shim
8 shared publicationsJisung Jung
Department of Radiology, Chung-Ang University College of Medicine, Seoul, Korea
4 shared publicationsKun Sang Kim
Department of Radiology, Yongsan Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
3 shared publicationsSerah Park
Department of Radiology, Chung-Ang University College of Medicine, Seoul, Korea
3 shared publications- Alavala Matta Reddy
School of Life and Health Sciences, Adikavi Nannaya University, Rajamahendravaram, India
2 shared publications Bon Chul Ha
Department of Radiology, Chung-ang University Hospital, Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 22 April 2015
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 12 (2) , e20782
Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study
Background: Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences. Objectives: This study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived mesenchymal stem cells (SPIO-hMSCs) compared with that of T2- and T2*-weighted imaging (T2WI and T2*WI, respectively) in a phantom and in vivo study in rats. Materials and Methods: A phantom was prepared with various cell concentrations. In one normal rat, SPIO-hMSCs were implanted directly through burr holes into both caudate putamens, while in three rats without and six rats with photothrombotic infarction, 2.5 × 105/ml SPIO-hMSCs were infused into the ipsilateral internal carotid artery (ICA). T2WI, T2*WI, and SWI findings were compared for dark regions representing SPIO-hMSCs. Results: SWI and T2*WI detected 15 µL of 13 SPIO-hMSCs/µL and 15 µL of 27 SPIO-hMSCs/µL in the phantom, respectively and 3 µL of 333 SPIO-hMSCs/µL and 3 µL of 167 SPIO-hMSCs/µL in the normal rat brain (direct implantation). In the normal rat brain (ICA infusion), one of the three cases showed numerous foci of dark regions dispersed throughout the brain on T2*WI and SWI. Dark regions surrounded the infarcts in all six infracted rat brains. The dark region was most prominent on SWI, followed by T2*WI and T2WI in all six rats (P = 0.002). Implanted SPIO-hMSCs were confirmed using Prussian blue staining. Conclusions: SWI is the most sensitive in the detection of SPIO-hMSCs, with the dark regions representing SPIO-hMSCs being more prominent on SWI than on T2*WI and T2WI. Keywords: Mesenchymal Stromal Cells; Cerebral Infarction; Rats; Ferrosoferric Oxide
- 22 April 2015
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 12 (2) , e20782
Open AccessSensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study
Background: Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences. Objectives: This study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived mesenchymal stem cells (SPIO-hMSCs) compared with that of T2- and T2*-weighted imaging (T2WI and T2*WI, respectively) in a phantom and in vivo study in rats. Materials and Methods: A phantom was prepared with various cell concentrations. In one normal rat, SPIO-hMSCs were implanted directly through burr holes into both caudate putamens, while in three rats without and six rats with photothrombotic infarction, 2.5 × 105/ml SPIO-hMSCs were infused into the ipsilateral internal carotid artery (ICA). T2WI, T2*WI, and SWI findings were compared for dark regions representing SPIO-hMSCs. Results: SWI and T2*WI detected 15 µL of 13 SPIO-hMSCs/µL and 15 µL of 27 SPIO-hMSCs/µL in the phantom, respectively and 3 µL of 333 SPIO-hMSCs/µL and 3 µL of 167 SPIO-hMSCs/µL in the normal rat brain (direct implantation). In the normal rat brain (ICA infusion), one of the three cases showed numerous foci of dark regions dispersed throughout the brain on T2*WI and SWI. Dark regions surrounded the infarcts in all six infracted rat brains. The dark region was most prominent on SWI, followed by T2*WI and T2WI in all six rats (P = 0.002). Implanted SPIO-hMSCs were confirmed using Prussian blue staining. Conclusions: SWI is the most sensitive in the detection of SPIO-hMSCs, with the dark regions representing SPIO-hMSCs being more prominent on SWI than on T2*WI and T2WI. Keywords: Mesenchymal Stromal Cells; Cerebral Infarction; Rats; Ferrosoferric Oxide
- 1 February 2015
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (2) , 219-227
Susceptibility-weighted imaging for stem cell visualization in a rat photothrombotic cerebral infarction model
Background: In cell therapy, magnetic resonance imaging (MRI) has been used to visualize superparamagnetic iron oxide (SPIO)-labeled stem cells homing to a lesion. Improving traceability is to utilize the sequence that maximizes sensitivity to the susceptibility effect of SPIO. Purpose: To explore the best method by comparing the MRI sequences to visualize mesenchymal stem cells (MSCs) labeled with SPIO. Material and Methods: Human bone marrow (hBM)-derived MSCs were labeled by internalization of SPIO nanoparticles. In vitro MRI was performed for the SPIO-labeled hBM-MSCs in tubes with T2-weighted (T2W), T2*-weighted (T2*W), and susceptibility-weighted images (SWI). Contrast-to-noise ratio (CNR) and volumes of dark signal of SPIO-labeled hBM-MSCs were obtained on images of each sequence. Photothrombotic cerebral infarction (PTCI) was induced in eight rats, and 2.5 × 105 SPIO-labeled hBM-MSCs were infused through the tail vein on the third day. In vivo MRI of the rat brain was performed using a 3.0 T MRI on the first, third, seventh, and 14th days. CNRspio was obtained on T2W imaging, T2*W imaging, and SWI. The dark signals were compared with the SPIO-positive cells of Prussian blue staining. Results: In vitro MRI of 5 × 105 SPIO-labeled hBM-MSCs showed the CNR and volume of dark signal to be 63, 517 mm3 in SWI, 41, 228 mm3 in T2*W imaging, and 56, 41 mm3 in T2W imaging, respectively. In vivo MRI showed a dark signal surrounding the high signal intensity of PTCI. Pathologically, the dark signals were matched with SPIO-labeled hBM-MSC in the corresponding rat. The dark signal was most prominent in SWI, then T2*W imaging, and finally in T2W imaging ( P <0.05). In SWI, other causes of dark signals were matched with the veins and the choroid plexuses on histopathology. Conclusion: SWI can visualize SPIO-labeled hBM-MSCs more sensitively, earlier, and with larger size and greater contrast than T2W imaging and T2*W imaging.
- 1 February 2015
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (2) , 219-227
Susceptibility-weighted imaging for stem cell visualization in a rat photothrombotic cerebral infarction model
Background: In cell therapy, magnetic resonance imaging (MRI) has been used to visualize superparamagnetic iron oxide (SPIO)-labeled stem cells homing to a lesion. Improving traceability is to utilize the sequence that maximizes sensitivity to the susceptibility effect of SPIO. Purpose: To explore the best method by comparing the MRI sequences to visualize mesenchymal stem cells (MSCs) labeled with SPIO. Material and Methods: Human bone marrow (hBM)-derived MSCs were labeled by internalization of SPIO nanoparticles. In vitro MRI was performed for the SPIO-labeled hBM-MSCs in tubes with T2-weighted (T2W), T2*-weighted (T2*W), and susceptibility-weighted images (SWI). Contrast-to-noise ratio (CNR) and volumes of dark signal of SPIO-labeled hBM-MSCs were obtained on images of each sequence. Photothrombotic cerebral infarction (PTCI) was induced in eight rats, and 2.5 × 105 SPIO-labeled hBM-MSCs were infused through the tail vein on the third day. In vivo MRI of the rat brain was performed using a 3.0 T MRI on the first, third, seventh, and 14th days. CNRspio was obtained on T2W imaging, T2*W imaging, and SWI. The dark signals were compared with the SPIO-positive cells of Prussian blue staining. Results: In vitro MRI of 5 × 105 SPIO-labeled hBM-MSCs showed the CNR and volume of dark signal to be 63, 517 mm3 in SWI, 41, 228 mm3 in T2*W imaging, and 56, 41 mm3 in T2W imaging, respectively. In vivo MRI showed a dark signal surrounding the high signal intensity of PTCI. Pathologically, the dark signals were matched with SPIO-labeled hBM-MSC in the corresponding rat. The dark signal was most prominent in SWI, then T2*W imaging, and finally in T2W imaging ( P <0.05). In SWI, other causes of dark signals were matched with the veins and the choroid plexuses on histopathology. Conclusion: SWI can visualize SPIO-labeled hBM-MSCs more sensitively, earlier, and with larger size and greater contrast than T2W imaging and T2*W imaging.
- Open Access
- 1 January 2015
- Published by XMLink in Korean Journal of Radiology
- Vol. 16 (3) , 575-585
Evaluation of Engraftment of Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells Using Three-Dimensional Reconstruction of Magnetic Resonance Imaging in Photothrombotic Cerebral Infarction Models of Rats
Shim J, et al. Korean J Radiol. 2015 May-Jun;16(3):575-585. https://doi.org/10.3348/kjr.2015.16.3.575
- 1 January 2015
- Published by XMLink in Korean Journal of Radiology
- Vol. 16 (3) , 575-585
Open AccessEvaluation of Engraftment of Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells Using Three-Dimensional Reconstruction of Magnetic Resonance Imaging in Photothrombotic Cerebral Infarction Models of Rats
Shim J, et al. Korean J Radiol. 2015 May-Jun;16(3):575-585. https://doi.org/10.3348/kjr.2015.16.3.575
- Open Access
- 18 January 2014
- Published by Springer Nature in Discover Nano
- Vol. 9 (1) , 38
Preparation and evaluation of poly(2-hydroxyethyl aspartamide)-hexadecylamine-iron oxide for MR imaging of lymph nodes
The purpose of this study was to synthesize biocompatible poly(2-hydroxyethyl aspartamide)–C16-iron oxide (PHEA-C16-iron oxide) nanoparticles and to evaluate their efficacy as a contrast agent for magnetic resonance imaging of lymph nodes. The PHEA-C16-iron oxide nanoparticles were synthesized by coprecipitation method. The core size of the PHEA-C16-iron oxide nanoparticles was about 5 to 7 nm, and the overall size of the nanoparticles was around 20, 60, and 150 nm in aqueous solution. The size of the nanoparticles was controlled by the amount of C16. The 3.0-T MRI signal intensity of a rabbit lymph node was effectively reduced after intravenous administration of PHEA-C16-iron oxide with the size of 20 nm. The in vitro and in vivo toxicity tests revealed the high biocompatibility of PHEA-C16-iron oxide nanoparticles. Therefore, PHEA-C16-iron oxide nanoparticles with 20-nm size can be potentially useful as T2-weighted MR imaging contrast agents for the detection of lymph nodes.
- 18 January 2014
- Published by Springer Nature in Discover Nano
- Vol. 9 (1) , 38
Open AccessPreparation and evaluation of poly(2-hydroxyethyl aspartamide)-hexadecylamine-iron oxide for MR imaging of lymph nodes
The purpose of this study was to synthesize biocompatible poly(2-hydroxyethyl aspartamide)–C16-iron oxide (PHEA-C16-iron oxide) nanoparticles and to evaluate their efficacy as a contrast agent for magnetic resonance imaging of lymph nodes. The PHEA-C16-iron oxide nanoparticles were synthesized by coprecipitation method. The core size of the PHEA-C16-iron oxide nanoparticles was about 5 to 7 nm, and the overall size of the nanoparticles was around 20, 60, and 150 nm in aqueous solution. The size of the nanoparticles was controlled by the amount of C16. The 3.0-T MRI signal intensity of a rabbit lymph node was effectively reduced after intravenous administration of PHEA-C16-iron oxide with the size of 20 nm. The in vitro and in vivo toxicity tests revealed the high biocompatibility of PHEA-C16-iron oxide nanoparticles. Therefore, PHEA-C16-iron oxide nanoparticles with 20-nm size can be potentially useful as T2-weighted MR imaging contrast agents for the detection of lymph nodes.
- Open Access
- 1 January 2013
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 54 (6) , 467-476
Engraftment of Human Mesenchymal Stem Cells in a Rat Photothrombotic Cerebral Infarction Model : Comparison of Intra-Arterial and Intravenous Infusion Using MRI and Histological Analysis
Byun JS, et al. J Korean Neurosurg Soc. 2013 Dec;54(6):467-476. http://dx.doi.org/10.3340/jkns.2013.54.6.467
- 1 January 2013
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 54 (6) , 467-476
Open AccessEngraftment of Human Mesenchymal Stem Cells in a Rat Photothrombotic Cerebral Infarction Model : Comparison of Intra-Arterial and Intravenous Infusion Using MRI and Histological Analysis
Byun JS, et al. J Korean Neurosurg Soc. 2013 Dec;54(6):467-476. http://dx.doi.org/10.3340/jkns.2013.54.6.467
- 31 July 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (7) , 941-946
A Radiofrequency Electrode Catheter–Guide Wire System for Arterial Occlusion
- 31 July 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (7) , 941-946
A Radiofrequency Electrode Catheter–Guide Wire System for Arterial Occlusion
- Open Access
- 1 January 2010
- Published by Korean Academy of Medical Sciences in Journal of Korean Medical Science
- Vol. 25 (2) , 211-219
In vivo Tracking of Mesenchymal Stem Cells Labeled with a Novel Chitosan-coated Superparamagnetic Iron Oxide Nanoparticles using 3.0T MRI
Reddy AM, et al. J Korean Med Sci. 2010 Feb;25(2):211-219. http://dx.doi.org/10.3346/jkms.2010.25.2.211
- 1 January 2010
- Published by Korean Academy of Medical Sciences in Journal of Korean Medical Science
- Vol. 25 (2) , 211-219
Open AccessIn vivo Tracking of Mesenchymal Stem Cells Labeled with a Novel Chitosan-coated Superparamagnetic Iron Oxide Nanoparticles using 3.0T MRI
Reddy AM, et al. J Korean Med Sci. 2010 Feb;25(2):211-219. http://dx.doi.org/10.3346/jkms.2010.25.2.211
- 23 March 2009
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 4 (3) , 118-126
Functional characterization of mesenchymal stem cells labeled with a novel PVP-coated superparamagnetic iron oxide
- 23 March 2009
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 4 (3) , 118-126
Functional characterization of mesenchymal stem cells labeled with a novel PVP-coated superparamagnetic iron oxide
- 1 June 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (3) , 370-374
Arterial Occlusion Using a Microguidewire as a Radiofrequency Electrode
Purpose: To illustrate the use of superselective radiofrequency (RF) energy delivery for arterial occlusion in vessels requiring embolization. Technique: A 3.0-F microcatheter and a 0.016-inch stainless steel microguidewire coated with polytetrafluoroethylene except for the floppy platinum-coiled tip are inserted into the diseased arteries. After positioning the microcatheter at the target site, the floppy tip of the microguidewire is advanced 1 to 2 cm beyond the microcatheter to act as an electrode. RF ablation is performed at a power of 20 watts until there was a rise in uncontrolled impedance. If occlusion is incomplete, embolic agents can be applied. The use of the technique is illustrated in 4 cases, 3 involving renal branch arteries and a large arteriovenous malformation in the buttock. RF energy was successful in occluding the target vessels in 3 cases; the other required additional embolization. There were no complications, and the patients had sustained occlusion of the lesions. Conclusion: Diseased arteries can be endovascularly occluded using a microguidewire to deliver radiofrequency energy. However, further development of the technique is needed to circumvent wire adhesion to the arterial wall and optimize RF delivery to avoid damage to adjacent structures.
- 1 June 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (3) , 370-374
Arterial Occlusion Using a Microguidewire as a Radiofrequency Electrode
Purpose: To illustrate the use of superselective radiofrequency (RF) energy delivery for arterial occlusion in vessels requiring embolization. Technique: A 3.0-F microcatheter and a 0.016-inch stainless steel microguidewire coated with polytetrafluoroethylene except for the floppy platinum-coiled tip are inserted into the diseased arteries. After positioning the microcatheter at the target site, the floppy tip of the microguidewire is advanced 1 to 2 cm beyond the microcatheter to act as an electrode. RF ablation is performed at a power of 20 watts until there was a rise in uncontrolled impedance. If occlusion is incomplete, embolic agents can be applied. The use of the technique is illustrated in 4 cases, 3 involving renal branch arteries and a large arteriovenous malformation in the buttock. RF energy was successful in occluding the target vessels in 3 cases; the other required additional embolization. There were no complications, and the patients had sustained occlusion of the lesions. Conclusion: Diseased arteries can be endovascularly occluded using a microguidewire to deliver radiofrequency energy. However, further development of the technique is needed to circumvent wire adhesion to the arterial wall and optimize RF delivery to avoid damage to adjacent structures.
- 15 February 2008
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 31 (4) , 790-798
A New Ischemic Model Using a Radiofrequency Wire Electrode in a Rabbit Hindlimb
- 15 February 2008
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 31 (4) , 790-798
A New Ischemic Model Using a Radiofrequency Wire Electrode in a Rabbit Hindlimb