Spandan Maiti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Spandan Maiti has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Thomas G. Gleason
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States; Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA, United States; Surgery, University of Pittsburgh, Pittsburgh, PA, United States; Center for Vascular Remodeling and Regeneration, University of Pittsburgh, Pittsburgh, PA, United States; Center for Vascular Remodeling and Regeneration, University of Pittsburgh, Pittsburgh, PA, United States
5 shared publicationsDavid A. Vorp
4 shared publicationsSiladitya Pal
Mechanical and Industrial Engineering Department, Indian Institute of Technology Roorkee, Roorkee, India
4 shared publications- James Thunes
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
3 shared publications - Ronald N. Fortunato
Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA
3 shared publications - Alkiviadis Tsamis
Department of Mechanical Engineering, School of Engineering, University of Western Macedonia, Kozani 50100, Greece
2 shared publications
Latest Publications
- 25 September 2020
- Published by Springer Nature in Experimental Mechanics
- Vol. 61 (1) , 5-18
Effect of Macro-calcification on the Failure Mechanics of Intracranial Aneurysmal Wall Tissue
Background Calcification was recently found to be present in the majority of cerebral aneurysms, though how calcification and the presence or absence of co-localized lipid pools affect failure properties is still unknown. Objective The primary objective is to quantify the biomechanical effect of a macro-calcification with surrounding Near-Calcification Region (NCR) of varying mechanical properties on tissue failure behavior. Methods We utilized a structurally informed finite element model to simulate pre-failure and failure behavior of a human cerebral tissue specimen modeled as a composite containing a macro-calcification and surrounding NCR, embedded in a fiber matrix composite. Data from multiple imaging modalities was combined to quantify the collagen organization and calcification geometry. An idealized parametric model utilizing the calibrated model was used to explore the impact of NCR properties on tissue failure. Results Compared to tissue without calcification, peak stress was reduced by 82% and 49% for low modulus (representing lipid pool) and high modulus (simulating increase in calcification size) of the NCR, respectively. Failure process strongly depended on NCR properties with lipid pools blunting the onset of complete failure. When the NCR was calcified, the sample was able to sustain larger overall stress, however the failure process was abrupt with nearly simultaneous failure of the loaded fibers. Conclusions Failure of calcified vascular tissue is strongly influenced by the ultrastructure in the vicinity of the calcification. Computational modeling of failure in fibrous soft tissues can be used to understand how pathological changes impact the tissue failure process, with potentially important clinical implications.
- 25 September 2020
- Published by Springer Nature in Experimental Mechanics
- Vol. 61 (1) , 5-18
Effect of Macro-calcification on the Failure Mechanics of Intracranial Aneurysmal Wall Tissue
Background Calcification was recently found to be present in the majority of cerebral aneurysms, though how calcification and the presence or absence of co-localized lipid pools affect failure properties is still unknown. Objective The primary objective is to quantify the biomechanical effect of a macro-calcification with surrounding Near-Calcification Region (NCR) of varying mechanical properties on tissue failure behavior. Methods We utilized a structurally informed finite element model to simulate pre-failure and failure behavior of a human cerebral tissue specimen modeled as a composite containing a macro-calcification and surrounding NCR, embedded in a fiber matrix composite. Data from multiple imaging modalities was combined to quantify the collagen organization and calcification geometry. An idealized parametric model utilizing the calibrated model was used to explore the impact of NCR properties on tissue failure. Results Compared to tissue without calcification, peak stress was reduced by 82% and 49% for low modulus (representing lipid pool) and high modulus (simulating increase in calcification size) of the NCR, respectively. Failure process strongly depended on NCR properties with lipid pools blunting the onset of complete failure. When the NCR was calcified, the sample was able to sustain larger overall stress, however the failure process was abrupt with nearly simultaneous failure of the loaded fibers. Conclusions Failure of calcified vascular tissue is strongly influenced by the ultrastructure in the vicinity of the calcification. Computational modeling of failure in fibrous soft tissues can be used to understand how pathological changes impact the tissue failure process, with potentially important clinical implications.
- 1 July 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 108, 109884
Computational modeling of the strength of the ascending thoracic aortic media tissue under physiologic biaxial loading conditions
- 1 July 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 108, 109884
Computational modeling of the strength of the ascending thoracic aortic media tissue under physiologic biaxial loading conditions
- 4 June 2019
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 18 (6) , 1791-1807
Computational modeling reveals the relationship between intrinsic failure properties and uniaxial biomechanical behavior of arterial tissue
Biomechanical failure of the artery wall can lead to rupture, a catastrophic event with a high rate of mortality. Thus, there is a pressing need to understand failure behavior of the arterial wall. Uniaxial testing remains the most common experimental technique to assess tissue failure properties. However, the relationship between intrinsic failure parameters of the tissue and measured uniaxial failure properties is not fully established. Furthermore, the effect of the experimental variables, such as specimen shape and boundary conditions, on the measured failure properties is not well understood. We developed a finite element model capable of recapitulating pre-failure and post-failure uniaxial biomechanical response of the arterial tissue specimen. Intrinsic stiffness, strength and fracture toughness of the vessel wall tissue were used as the input material parameters to the model. Two uniaxial testing protocols were considered: a conventional setup with a rectangular specimen held at the grips by cardboard inserts, and the other used a dogbone specimen with soft foam inserts at the grips. Our computational study indicated negligible differences in the peak stress and post-peak mechanical behavior between these two testing protocols. It was also found that the tissue experienced only modest localized failure until higher levels of applied stretch beyond the peak stress. A robust cohesive model was capable of modeling the post-peak biomechanical response, which was primarily governed by tissue fracture toughness. Our results suggest that the post-peak region, in conjunction with the peak stress, must be considered to evaluate the complete biomechanical failure behavior of the soft tissue.
- 4 June 2019
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 18 (6) , 1791-1807
Computational modeling reveals the relationship between intrinsic failure properties and uniaxial biomechanical behavior of arterial tissue
Biomechanical failure of the artery wall can lead to rupture, a catastrophic event with a high rate of mortality. Thus, there is a pressing need to understand failure behavior of the arterial wall. Uniaxial testing remains the most common experimental technique to assess tissue failure properties. However, the relationship between intrinsic failure parameters of the tissue and measured uniaxial failure properties is not fully established. Furthermore, the effect of the experimental variables, such as specimen shape and boundary conditions, on the measured failure properties is not well understood. We developed a finite element model capable of recapitulating pre-failure and post-failure uniaxial biomechanical response of the arterial tissue specimen. Intrinsic stiffness, strength and fracture toughness of the vessel wall tissue were used as the input material parameters to the model. Two uniaxial testing protocols were considered: a conventional setup with a rectangular specimen held at the grips by cardboard inserts, and the other used a dogbone specimen with soft foam inserts at the grips. Our computational study indicated negligible differences in the peak stress and post-peak mechanical behavior between these two testing protocols. It was also found that the tissue experienced only modest localized failure until higher levels of applied stretch beyond the peak stress. A robust cohesive model was capable of modeling the post-peak biomechanical response, which was primarily governed by tissue fracture toughness. Our results suggest that the post-peak region, in conjunction with the peak stress, must be considered to evaluate the complete biomechanical failure behavior of the soft tissue.
- 4 April 2018
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (6)
A Uniaxial Testing Approach for Consistent Failure in Vascular Tissues
Although uniaxial tensile testing is commonly used to evaluate failure properties of vascular tissue, there is no established protocol for specimen shape or gripping method. Large percentages of specimens are reported to fail near the clamp and can potentially confound the studies, or, if discarded will result in sample waste. The objective of this study is to identify sample geometry and clamping conditions that can achieve consistent failure in the midregion of small arterial specimens, even for vessels from older individuals. Failure location was assessed in 17 dogbone specimens from human cerebral and sheep carotid arteries using soft inserts. For comparison with commonly used protocols, an additional 22 rectangular samples were tested using either sandpaper or foam tape inserts. Midsample failure was achieved in 94% of the dogbone specimens, while only 14% of the rectangular samples failed in the midregion, the other 86% failing close to the clamps. Additionally, we found midregion failure was more likely to be abrupt, caused by cracking or necking. In contrast, clamp failure was more likely to be gradual and included a delamination mode not seen in midregion failure. Hence, this work provides an approach that can be used to obtain consistent midspecimen failure, avoiding confounding clamp-related artifacts. Furthermore, with consistent midregion failure, studies can be designed to image the failure process in small vascular samples providing valuable quantitative information about changes to collagen and elastin structure during the failure process.
- 4 April 2018
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (6)
A Uniaxial Testing Approach for Consistent Failure in Vascular Tissues
Although uniaxial tensile testing is commonly used to evaluate failure properties of vascular tissue, there is no established protocol for specimen shape or gripping method. Large percentages of specimens are reported to fail near the clamp and can potentially confound the studies, or, if discarded will result in sample waste. The objective of this study is to identify sample geometry and clamping conditions that can achieve consistent failure in the midregion of small arterial specimens, even for vessels from older individuals. Failure location was assessed in 17 dogbone specimens from human cerebral and sheep carotid arteries using soft inserts. For comparison with commonly used protocols, an additional 22 rectangular samples were tested using either sandpaper or foam tape inserts. Midsample failure was achieved in 94% of the dogbone specimens, while only 14% of the rectangular samples failed in the midregion, the other 86% failing close to the clamps. Additionally, we found midregion failure was more likely to be abrupt, caused by cracking or necking. In contrast, clamp failure was more likely to be gradual and included a delamination mode not seen in midregion failure. Hence, this work provides an approach that can be used to obtain consistent midspecimen failure, avoiding confounding clamp-related artifacts. Furthermore, with consistent midregion failure, studies can be designed to image the failure process in small vascular samples providing valuable quantitative information about changes to collagen and elastin structure during the failure process.
- 1 April 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 71, 84-93
Structural modeling reveals microstructure-strength relationship for human ascending thoracic aorta
- 1 April 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 71, 84-93
Structural modeling reveals microstructure-strength relationship for human ascending thoracic aorta
- 1 June 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (9) , 1562-1569
A structural finite element model for lamellar unit of aortic media indicates heterogeneous stress field after collagen recruitment
- 1 June 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (9) , 1562-1569
A structural finite element model for lamellar unit of aortic media indicates heterogeneous stress field after collagen recruitment
- 1 August 2015
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 137 (8) , 081012
The Effect of Size and Location of Tears in the Supraspinatus Tendon on Potential Tear Propagation
Rotator cuff tears are a common problem in patients over the age of 50 yr. Tear propagation is a potential contributing factor to the failure of physical therapy for treating rotator cuff tears, thus requiring surgical intervention. However, the evolution of tears within the rotator cuff is not well understood yet. The objective of this study is to establish a computational model to quantify initiation of tear propagation in the supraspinatus tendon and examine the effect of tear size and location. A 3D finite element (FE) model of the supraspinatus tendon was constructed from images of a healthy cadaveric tendon. A tear of varying length was placed at six different locations within the tendon. A fiber-reinforced Mooney–Rivlin material model with spatial variation in material properties along the anterior–posterior (AP) axis was utilized to obtain the stress state of the computational model under uniaxial stretch. Material parameters were calibrated by comparing computational and experimental stress–strain response and used to validate the computational model. The stress state of the computational model was contrasted against the spatially varying material strength to predict the critical applied stretch at which a tear starts propagating further. It was found that maximum principal stress (as well as the strain) was localized at the tips of the tear. The computed critical stretch was significantly lower for the posterior tip of the tear than for the anterior tip suggesting a propensity to propagate posteriorly. Onset of tear propagation was strongly correlated with local material strength and stiffness in the vicinity of the tear tip. Further, presence of a stress-shielded zone along the edges of the tear was observed. This study illustrates the complex interplay between geometry and material properties of tendon up to the initiation of tear propagation. Future work will examine the evolution of tears during the propagation process as well as under more complex loading scenarios.
- 1 August 2015
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 137 (8) , 081012
The Effect of Size and Location of Tears in the Supraspinatus Tendon on Potential Tear Propagation
Rotator cuff tears are a common problem in patients over the age of 50 yr. Tear propagation is a potential contributing factor to the failure of physical therapy for treating rotator cuff tears, thus requiring surgical intervention. However, the evolution of tears within the rotator cuff is not well understood yet. The objective of this study is to establish a computational model to quantify initiation of tear propagation in the supraspinatus tendon and examine the effect of tear size and location. A 3D finite element (FE) model of the supraspinatus tendon was constructed from images of a healthy cadaveric tendon. A tear of varying length was placed at six different locations within the tendon. A fiber-reinforced Mooney–Rivlin material model with spatial variation in material properties along the anterior–posterior (AP) axis was utilized to obtain the stress state of the computational model under uniaxial stretch. Material parameters were calibrated by comparing computational and experimental stress–strain response and used to validate the computational model. The stress state of the computational model was contrasted against the spatially varying material strength to predict the critical applied stretch at which a tear starts propagating further. It was found that maximum principal stress (as well as the strain) was localized at the tips of the tear. The computed critical stretch was significantly lower for the posterior tip of the tear than for the anterior tip suggesting a propensity to propagate posteriorly. Onset of tear propagation was strongly correlated with local material strength and stiffness in the vicinity of the tear tip. Further, presence of a stress-shielded zone along the edges of the tear was observed. This study illustrates the complex interplay between geometry and material properties of tendon up to the initiation of tear propagation. Future work will examine the evolution of tears during the propagation process as well as under more complex loading scenarios.
- 1 June 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (9) , 1566-1574
The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading
- 1 June 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (9) , 1566-1574
The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading
- 1 December 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (16) , 3820-3824
Effect of aneurysm on biomechanical properties of “radially-oriented” collagen fibers in human ascending thoracic aortic media
- 1 December 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (16) , 3820-3824
Effect of aneurysm on biomechanical properties of “radially-oriented” collagen fibers in human ascending thoracic aortic media
- 1 March 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (5) , 981-988
A mechanistic model on the role of “radially-running” collagen fibers on dissection properties of human ascending thoracic aorta
- 1 March 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (5) , 981-988
A mechanistic model on the role of “radially-running” collagen fibers on dissection properties of human ascending thoracic aorta