Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tao Lin has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Optimization Model Solution Method for Transient Voltage Stability Emergency Control in High-Voltage DC Receiving End

    by Weigang Jin, Tao Lin, Jiawei Zhang, Jiayi Wang, Jun Li, Chen Li

    In the context of the “dual-carbon” target, the large-scale integration of renewable energy sources leads to an increased risk of transient voltage instability at the high voltage direct current (HVDC) transmission receiving end. The HVDC transmission system possesses fast and accurate power regulation capability. After a fault occurs near the inverter station, reducing the DC current enables the reactive power from the compensation devices to be released and injected into the receiving-end power grid, thereby providing emergency voltage support for the receiving-end grid. To reduce control costs, an optimization model constrained by transient voltage violation is established, and the DC current modulation is acquired via an online solution. To maintain system stability and meet the requirements of online applications, it is crucial to rapidly solve the optimization model based on the grid operating mode and contingency information to update the emergency control strategy table in the special protection system (SPS). Conventional global orthogonal collocation (GOC) and adaptive orthogonal collocation (AOC)-based solution methods transform the optimization model in the continuous time domain into a nonlinear programming (NLP) problem for solution, which addresses the low efficiency of traditional rolling optimization. However, the GOC- and AOC-based solution methods improve the discretization accuracy of the model by pursuing global uniform densification of collocation points, making it difficult to balance solution accuracy and solution efficiency. To this end, this paper proposes an efficient interval partition dynamic adaptive orthogonal collocation (IP-DAOC)-based solution method. Firstly, the overall optimization time window is interval-partitioned into multiple initial intervals, and an interval-partitioned transient voltage stability emergency control optimization model is established. Furthermore, the interval length and the number of collocation points are dynamically adjusted according to the curvature of interpolation polynomials at collocation points in different intervals. Finally, after interval adjustment, the dynamic equations discretized in adjacent intervals are made continuous by reconstructing the differential matrix. This solution method reduces the total number of collocation points, thereby decreasing the scale of the NLP problem and narrowing the search space, significantly improving solution efficiency while ensuring solution accuracy. To verify the effectiveness of the proposed solution method, simulations are carried out on a modified IEEE 14-bus system. The results are compared with those of the traditional GOC- and AOC-based solution methods, which further demonstrate the superiority of the proposed solution method.

  • Open Access

    State Estimation of Power Systems Under Measurement Anomalies

    by Tao Lin, Jiawei Zhang, Zhengyang Lin, Jun Li, Chen Li, Xialing Xu

    As a product of the integration of information and communication technologies, smart grid has greatly enhanced the efficiency of power system. However, with the development of the smart grid towards deep digitalization and interconnection, state estimation (SE) of power systems is facing dual challenges of a complex measurement environment and threat of cyber-attacks. The integrity and reliability of measurement data are affected by sensor failure, complex environmental noise, and data packet loss, causing state estimation deviations. Meanwhile, in recent years, malicious cyber-attacks, mainly in the form of false data injection into (FDIA) and denial-of-service (DoS), have also threatened the stable operation of power systems. This paper systematically reviews research achievements in related fields. Firstly, an analysis is conducted on the causes and mechanisms of measurement anomalies such as measurement loss, complex noise, and cyber-attacks. Then, the existing identification methods of measurement anomalies are reviewed, and state estimation methods for power systems under measurement anomaly conditions are analyzed from three perspectives: model-driven, data-driven, and hybrid-driven. Finally, advantages and disadvantages of various methods are analyzed, and future research directions are prospected, aiming to provide a reference for building a highly resilient and adaptive smart grid monitoring system.


  • Open Access

    Sub/Super-Synchronous Oscillation Oriented Dominant Controller Parameters Stability Region Based on Gerschgorin Disk Theorem

    by Song Ke, Tao Lin, Yibiao Sheng, Hui Du, Shuitian Li, Baoping Chen, Rusi Chen, Qingyan Li

    Since the development of renewable power generation, Sub/Super-Synchronous Control Interac-tion (SSCI), has attracted wide attention. Sub/super-synchronous oscillation (SSO) belongs to the category of small signal stability, and its characteristics are closely related to the operation mode and controller parameters in power grid. The operation mode of renewable power system changes frequently, a method to construct controller parameter stability region (PSR) is proposed for online assessment of the matching degree of controller parameters in power grid under current operation mode. Based on Gerschgorin disk theorem (GDT), eigenvalue distribution range of the system state matrix is estimated, thus the feasible value set of the controller parameter is deduced through small signal stability criterion. The stability margin evaluation index is proposed for guiding the prevention and control of SSO. Specifically, the preconditions of the application of the GDT on the PSR construction are discussed, and a construction method of transition matrix is proposed for the PSR construction. Furthermore, to reduce the conservativeness of PSR, an extension method for PSR is given. Finally, the validity of the proposed method is verified by a realistic benchmark. The efficiency of the proposed method is highlighted by comparing with the point-wise eigenvalue calculation of the state matrix.


  • Open Access

    A Novel Self-Healing Strategy for Distribution Network with Distributed Generators Considering Uncertain Power-Quality Constraints

    by Song Ke, Tao Lin, Rusi Chen, Hui Du, Shuitian Li, Xialing Xu

    Self-healing of smart distribution networks with distributed generators, which are usually operated as independent islands after fault, can improve power-supply reliability. As a hot research topic, a self-healing scheme is usually treated as the output of a nonlinear optimizuoation model. However, existing strategies have two main shortcomings. The first, high-optimization dimension, results in low-optimization efficiency. The second, the effects of power-quality issues, which are more serious on islands and may further threaten the safe operation of islands, is usually neglected. To quickly obtain a reliable self-healing scheme, a novel strategy is proposed. As the first step, the distribution network after a fault occurrence can be divided into several trouble-free subnets via the connectivity analysis; each subnet is called an initial island. Further, for each initial island, a two-step optimization model of self-healing, which consists of load-shedding optimization and network reconfiguration optimization, is proposed to obtain the self-healing strategy with lower searching space as well as higher solving efficiency. In detail, in load-shedding optimization, by means of heuristic differential evolution algorithm, larger total recovery capacity is achieved by considering the droop characteristic of distributed generators (DGs) within the permissible change in frequency. In network-reconfiguration optimization, based on the improved hybrid particle swarm optimization algorithm, a comprehensive set of power-quality constraints, including constraint of change in frequency, uncertain constraints of node voltage total harmonic distortion (THD), and negative sequence components of DGs, is developed to guarantee the reliability of each island. To evaluate whether the constraints are satisfied during the optimization procedure, an improved flexible power-flow algorithm is developed to calculate the power flow of each island under change in frequency. Further, 2m+1-point estimate method is employed for uncertainty analyses of the distributions of harmonic and negative sequence components caused by the uncertainty of corresponding sources. Finally, via a 94-node practical distribution network, the effectiveness and advantages of the proposed strategy in safety, recovery capacity, and optimization efficiency are verified.


  • Open Access

    Electromagnetic torque analysis‐based method for performance evaluation and optimisation of closed‐loop CPS regarding small signal stability

    by Yibiao Sheng, Tao Lin, Rusi Chen, Baoping Chen, Guili Ding, Xialing Xu, Chang Xie, Lin Liu

    Low frequency oscillation occurs frequently in the smart grid, which threatens the security andstability of the physical system. Wide‐area damping controller (WADC), whichbelongs to cyber system, can effectively suppress inter‐area low frequencyoscillations and improve the small signal stability of the closed‐loopcyber‐physical system (CPS). However, with the introduction of global signals,time delays of communication are inevitable. Considering that, this paperdeduces the general mathematics expression among electromagnetic torquecoefficients, WADC control parameters and time delays, which makes it possibleto analyse the influence mechanism of time delay on small signal stability.Based on these analysis, on the one hand, the time‐delay small signal stabilityregion is established to evaluate the operation state of closed‐loop CPS, on theother hand, if small signal stability is not achieved due to the measured timedelays, optimisation scheme is proposed to carry out WADC control parameterscoordination to optimise small signal stability of the closed‐loop system.Finally, taking two time delays as example, this study verifies theeffectiveness and advantages of the proposed method by comparing the closed‐loopsystem performance considering two time delays with the cases of consideringsinge time delay and without time delay.


  • A New Out-of-Step Splitting Strategy Based on Compound Information

    by Youqiang Xiao, Hangpeng Ni, Wen Qian, Tao Lin, Ruyu Bi

  • Open Access

    Alleviation of post‐contingency overloads by SOCP based corrective control considering TCSC and MTDC

    by Ruyu Bi, Tao Lin, Rusi Chen, Jing Ye, Xueming Zhou, Xialing Xu

    With the increasing installation of the high‐voltage direct current device and flexible AC transmission system, the power transfer capability increases significantly. However, the risk of line overloads or even cascading failures caused by DC blocking or line outage also augments, which requires accurate and effective post‐contingency corrective control (CC) actions. Traditional sensitivity‐based methods are fast, but are less accurate and may suffer from the seesaw problem. Artificial intelligence optimisation‐based methods usually exhibit better CC performance but are time‐consuming. For fastly performing accurate CC actions, a second‐order cone programming (SOCP)‐based CC optimisation model for line overloads alleviation in meshed AC/DC power systems is proposed. Initially, to reduce the number of CC actions and optimisation variables (OVs), a heuristic search method is proposed to automatically select the most effective generators/loads for the overloaded lines. Subsequently, thyristor controlled series capacitor (TCSC) compensation levels and multi‐terminal direct current (MTDC) power are treated as additional OVs to minimise load shedding/generation rescheduling. Additionally, to boost computational efficiency, SOCP format power flow equations for systems with MTDCs and TCSCs are proposed. Eventually, the effectiveness, accuracy, and superiority in computational efficiency of the proposed method are verified based on the modified IEEE 30‐bus test system.


  • Open Access

    Novel Method for Rapidly Constructing Active Power Steady-State Security Regions Incorporating the Equivalent Reactances of TCSCs

    by Rusi Chen, Tao Lin, Baoping Chen, Ruyu Bi, Xialing Xu

    Active power steady-state security regions (APSSRs), which can provide guidance for prevention and control through security checks, is of great importance for the safe operation of power systems in which more and more sustainable energy power generation is integrated. As a mature flexible AC transmission system (FACTS) device, thyristor-controlled series compensators (TCSCs) can carry out series compensation for the transmission line by controlling its equivalent reactance. With the change of the equivalent reactance parameter of a TCSC, the nodal admittance matrix and power flow distribution of the power system also changes. Inevitably, the APSSR will be different. Therefore, it is necessary and important to further incorporate the equivalent reactance parameters of TCSCs in the APSSR expression, which is generally established in the space of node active power injections. In this paper, a rapid construction method of APSSRs incorporating the equivalent reactances of TCSCs is proposed. Firstly, applicability and efficiency of the conventional APSSR construction method for power systems with TCSCs are analyzed. Further, with equivalent disconnection of TCSC branches, the effect of TCSC equivalent reactances on the distribution of active power flow through changing the structure parameters is treated as modifying node active power injections. On this basis, explicit expressions of APSSRs with a single TCSC equivalent reactance parameter and double TCSC equivalent reactance parameters are derived, respectively. Moreover, by deducing the general formula of APSSRs with multiple TCSC equivalent reactance parameters, the feasibility of the proposed method for power systems with multiple TCSCs is analyzed. Eventually, via benchmarks with different scales and a different number of TCSCs, validity and superiorities of the proposed method in computational efficiency are demonstrated.


  • Open Access

    Novel Detection Method for Consecutive DC Commutation Failure Based on Daubechies Wavelet with 2nd-Order Vanishing Moments

    by Tao Lin, Ziyu Guo, Liyong Wang, Rusi Chen, Ruyu Bi

    Accurate detection and effective control strategy of commutation failure (CF) of high voltage direct current (HVDC) are of great significance for keeping the safe and stable operations of the hybrid power grid. At first, a novel detection method for consecutive CF is proposed. Concretely, the 2nd and higher orders’ derivative values of direct current are summarized as the core to judge CF by analyzing the physical characteristics of the direct current waveform of the converter station in CF. Then, the Daubechies wavelet coefficient that can represent the 2nd and higher order derivative values of direct current is derived. Once the wavelet coefficients of the sampling points are detected to exceed the threshold, the occurrence of CF is confirmed. Furthermore, by instantly increasing advanced firing angle β in the inverter side, an additional emergency control strategy to prevent subsequent CF is proposed. Eventually, with simulations of the benchmark model, the effectiveness and superiorities of the proposed detection method and additional control strategy in accuracy and rapidity are verified.


  • Open Access

    Novel Strategy for Accurate Locating of Voltage Sag Sources in Smart Distribution Networks with Inverter-Interfaced Distributed Generators

    by Rusi Chen, Tao Lin, Ruyu Bi, Xialing Xu

    With the aid of power quality monitoring systems (PQMSs), accurate locating of voltage sag sources, which has important significance for guiding maintenance personnel in finding and repairing faults as well as improving power supply reliability, has been becoming a new research hotspot. However, existing methods have unsatisfactory locating accuracy due to the integration of distributed generators (DGs) and fault resistance. In this paper, a novel strategy for accurately locating voltage sag sources in smart distribution networks is proposed. Based on inverse theory, which is well applied in geophysics, the accurate location issue is treated as a two-step optimization model. It aims at making the distribution of voltage phasors and current phasors obtained by theoretical short-circuit calculation match those actually observed as closely as possible. To guarantee the feasibility of the strategy, the effect of inverter-interfaced DGs (IIDGs) which are the main form of DG is considered in the short-circuit calculations. To guarantee the location accuracy of the strategy, fault resistance is treated as an optimization variable in the two-step optimization model to eliminate estimation error of fault resistance. Via two modified IEEE benchmarks with different scales, the validity and the superiorities in applicability and accuracy of the proposed strategy are verified.