Naresh Kumar Mani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naresh Kumar Mani has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
Anusha Prabhu
Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India
13 shared publications- Raja Chinnappan
College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
5 shared publications - Ahmed Yaqinuddin
College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
4 shared publications - Khaled Alkattan
College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
4 shared publications - Anusha Prabhu
Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India
3 shared publications - Balachandar Sundarrajan
Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India
3 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by Springer Nature in Scientific Reports
Bio-waste-derived chicken feather carbon-integrated ZnGa2O4 nanocomposites for asymmetric supercapacitor application
The pursuit of next-generation energy storage systems necessitates the development of advanced electrode materials that offer both high charge storage capacity and outstanding cycling stability to meet the increasing need for advanced energy storage devices. Engineering hybrid nanostructures that combine conductivity, porosity, and electrochemical activity offers a promising pathway to elevate supercapacitor performance. This study reports the hydrothermal synthesis of ZnGa 2 O 4 /chicken feather carbon (ZGO/CFC) composites using varying amounts of chicken feather-derived carbon (40, 65, and 100 mg) as a sustainable carbon source. Comprehensive characterization techniques including X-ray diffraction (XRD), Raman Spectroscopy, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Brunauer-Emmett-Teller (BET) analyses confirm the formation of a well-crystallized cubic ZnGa 2 O 4 structure, along with its morphological characteristics, elemental composition, and porosity. Electrochemical characterization reveal that the ZnGa 2 O 4 /100 mg chicken feather carbon electrode exhibits the highest specific capacitance of about 642.0 F g − 1 at 1 A g − 1 surpassing its counterparts. Asymmetric supercapacitor fabricated from ZnGa 2 O 4 /100 mg chicken feather carbon electrode shows specific capacitance of 67.33 F g − 1 with energy and power densities of about 21.04 Wh kg − 1 ,750 W kg − 1 respectively. In addition, it achieves a capacitive retention rate of about 94.0% and coulombic efficiency of about 95.0% which demands the integration of metal oxides with low-cost, renewable carbon materials as an effective strategy for advancing the performance of supercapacitors. The optimized ZGO/CFC composites demonstrate promising prospects for high-performance supercapacitor applications, facilitating the development for green energy storage solutions.
- 8 October 2026
- Published by Springer Nature in Scientific Reports
Open AccessBio-waste-derived chicken feather carbon-integrated ZnGa2O4 nanocomposites for asymmetric supercapacitor application
The pursuit of next-generation energy storage systems necessitates the development of advanced electrode materials that offer both high charge storage capacity and outstanding cycling stability to meet the increasing need for advanced energy storage devices. Engineering hybrid nanostructures that combine conductivity, porosity, and electrochemical activity offers a promising pathway to elevate supercapacitor performance. This study reports the hydrothermal synthesis of ZnGa 2 O 4 /chicken feather carbon (ZGO/CFC) composites using varying amounts of chicken feather-derived carbon (40, 65, and 100 mg) as a sustainable carbon source. Comprehensive characterization techniques including X-ray diffraction (XRD), Raman Spectroscopy, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Brunauer-Emmett-Teller (BET) analyses confirm the formation of a well-crystallized cubic ZnGa 2 O 4 structure, along with its morphological characteristics, elemental composition, and porosity. Electrochemical characterization reveal that the ZnGa 2 O 4 /100 mg chicken feather carbon electrode exhibits the highest specific capacitance of about 642.0 F g − 1 at 1 A g − 1 surpassing its counterparts. Asymmetric supercapacitor fabricated from ZnGa 2 O 4 /100 mg chicken feather carbon electrode shows specific capacitance of 67.33 F g − 1 with energy and power densities of about 21.04 Wh kg − 1 ,750 W kg − 1 respectively. In addition, it achieves a capacitive retention rate of about 94.0% and coulombic efficiency of about 95.0% which demands the integration of metal oxides with low-cost, renewable carbon materials as an effective strategy for advancing the performance of supercapacitors. The optimized ZGO/CFC composites demonstrate promising prospects for high-performance supercapacitor applications, facilitating the development for green energy storage solutions.
- 3 July 2026
- Published by Taylor & Francis in Bioanalysis
- Vol. 18 (10) , 911-932
Dry chemistry-based approaches for point-of-care (POC) diagnostics
1. “Prevention is better than cure” is a classic saying that continues to influence the future of health care. In the relentless drive to improve patient outcomes, advancements in early disease det...
- 3 July 2026
- Published by Taylor & Francis in Bioanalysis
- Vol. 18 (10) , 911-932
Dry chemistry-based approaches for point-of-care (POC) diagnostics
1. “Prevention is better than cure” is a classic saying that continues to influence the future of health care. In the relentless drive to improve patient outcomes, advancements in early disease det...
- Open Access
- 29 May 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (24) , 5105-5115
A novel bubble rupture sensing methodology for sweat-driven disease diagnostics
The ionic strength of sweat fluid influences the bubble bursting time.
- 29 May 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (24) , 5105-5115
Open AccessA novel bubble rupture sensing methodology for sweat-driven disease diagnostics
The ionic strength of sweat fluid influences the bubble bursting time.
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Sustainable Food Technology
An ultra-frugal press-and-detect assay for the qualitative assessment of milk fat using silicon carbide sandpaper and milk skin
A simple, low-cost press-and-detect method was developed for qualitative milk fat analysis using sandpaper and lactoderm, offering a robust alternative to conventional methods in resource-limited settings.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Sustainable Food Technology
Open AccessAn ultra-frugal press-and-detect assay for the qualitative assessment of milk fat using silicon carbide sandpaper and milk skin
A simple, low-cost press-and-detect method was developed for qualitative milk fat analysis using sandpaper and lactoderm, offering a robust alternative to conventional methods in resource-limited settings.
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
Lab-on-a-tip platform with cotton matrices for colorimetric detection of carmine in lipsticks
Cotton-based lab-on-a-tip device enables colorimetric detection of carmine through formation of a brown ferric–carminic acid complex with a LOD of 0.5 mg mL −1 . The assay's potential using commercial lipstick underscores a portable low-cost platform.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
Open AccessLab-on-a-tip platform with cotton matrices for colorimetric detection of carmine in lipsticks
Cotton-based lab-on-a-tip device enables colorimetric detection of carmine through formation of a brown ferric–carminic acid complex with a LOD of 0.5 mg mL −1 . The assay's potential using commercial lipstick underscores a portable low-cost platform.
- Open Access
- 29 September 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Distance-based ratio metric assay using thread-based devices for Karaya gum detection in food samples
Karaya gum, a natural food-grade thickener, is an adulterant that compromises product quality and consumer safety. Herein, we develop a low-cost, rapid and portable device that employs thread-based microfluidics integrated with ratio-metric displacement to detect and quantify Karaya gum, with a limit of detection of 0.1%w/v. The interaction between the cellulose in the bamboo viscose thread and the chlor-zinc-iodide reagent causes the thread to turn blue immediately. On addition of simulated Karaya gum samples, a brown region appears beyond the blue region due to hydrogen bond formation between the hydroxyl groups of the thread and the complex sugars in the gum, thereby causing the displacement of iodine, which was confirmed by FTIR analysis. Higher gum concentrations increase viscosity and result in less displacement of iodine, with the blue-to-brown colorimetric ratio being directly proportional to the gum concentration. These observations were confirmed by measuring the viscosity of the Karaya gum and correlating it with the structure and nature of the gum. Furthermore, the variation in the iodine release was quantified using grayscale values utilizing Fiji software. The device was implemented for field trial using commercial basil drink. This approach offers an efficient alternative to conventional cumbersome detection strategies and has enormous potential for onsite food safety and quality control.
- 29 September 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Open AccessDistance-based ratio metric assay using thread-based devices for Karaya gum detection in food samples
Karaya gum, a natural food-grade thickener, is an adulterant that compromises product quality and consumer safety. Herein, we develop a low-cost, rapid and portable device that employs thread-based microfluidics integrated with ratio-metric displacement to detect and quantify Karaya gum, with a limit of detection of 0.1%w/v. The interaction between the cellulose in the bamboo viscose thread and the chlor-zinc-iodide reagent causes the thread to turn blue immediately. On addition of simulated Karaya gum samples, a brown region appears beyond the blue region due to hydrogen bond formation between the hydroxyl groups of the thread and the complex sugars in the gum, thereby causing the displacement of iodine, which was confirmed by FTIR analysis. Higher gum concentrations increase viscosity and result in less displacement of iodine, with the blue-to-brown colorimetric ratio being directly proportional to the gum concentration. These observations were confirmed by measuring the viscosity of the Karaya gum and correlating it with the structure and nature of the gum. Furthermore, the variation in the iodine release was quantified using grayscale values utilizing Fiji software. The device was implemented for field trial using commercial basil drink. This approach offers an efficient alternative to conventional cumbersome detection strategies and has enormous potential for onsite food safety and quality control.
- Open Access
- 12 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 603
From Biomarkers to Biosensors: Modern Approaches for the Detection of Matrix Metalloproteinases (MMPs)
Matrix metalloproteinases (MMPs) are a class of extracellular Zn2+ peptidases involved in various physiological and pathological processes. These enzymes serve as excellent biomarkers for diagnosing various diseases, including cancer and periodontitis, to name a few. MMP levels also serve as a prognostic marker, which helps determine how much the disease has progressed. However, the current methods used to detect MMPs need a large sample volume, carry a high cost, and are not widely accessible to the public due to these challenges. Biosensing techniques tackle these problems by providing an efficient, cost-effective sensor with great sensitivity. This review provides a comprehensive overview of the latest developments and advancements in detecting MMPs using biosensors that employ various detection mechanisms such as electrochemical, colorimetric, and fluorescence methods. Furthermore, we have discussed the challenges and prospects of using MMPs as diagnostic tools.
- 12 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 603
Open AccessFrom Biomarkers to Biosensors: Modern Approaches for the Detection of Matrix Metalloproteinases (MMPs)
Matrix metalloproteinases (MMPs) are a class of extracellular Zn2+ peptidases involved in various physiological and pathological processes. These enzymes serve as excellent biomarkers for diagnosing various diseases, including cancer and periodontitis, to name a few. MMP levels also serve as a prognostic marker, which helps determine how much the disease has progressed. However, the current methods used to detect MMPs need a large sample volume, carry a high cost, and are not widely accessible to the public due to these challenges. Biosensing techniques tackle these problems by providing an efficient, cost-effective sensor with great sensitivity. This review provides a comprehensive overview of the latest developments and advancements in detecting MMPs using biosensors that employ various detection mechanisms such as electrochemical, colorimetric, and fluorescence methods. Furthermore, we have discussed the challenges and prospects of using MMPs as diagnostic tools.
- Open Access
- 9 July 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (28) , 31059-31065
What’s in My Coffee? Do-It-Yourself Testing for Chicory Adulteration Using Particle Trapping in Stencil-Based Paper Devices
Our study introduces a cost-effective Do-It-Yourself (DIY) method for detecting chicory adulteration in coffee powder via the Shake & Invert approach integrated with a particle trapping mechanism. Coffee powders of different sizes were blended with chicory in distinct proportions. A bioline layer was employed as an adhering agent to selectively capture chicory on a laminated paper-based device. This selective adhesion is attributed primarily to the differences in surface morphology between the coffee and chicory particles. The texture and structural arrangement of the particles play crucial roles in determining their interaction with the bioline-coated surface. SEM imaging provided further insight into these differences, revealing that chicory possesses rough and distinctive fiber-like structures, whereas the coffee particles have a uniform plate-like surface. These structural characteristics are believed to enhance its adhesion toward the bioline-coated paper, resulting in superior adhesion compared with that of the coffee particles. Our developed approach exhibited a limit of detection (LOD) at a coffee-to-chicory ratio of 90:10. This understanding of the distinct physical properties of chicory and coffee underscores the effectiveness of our adhesive testing method, indicating its potential as a robust tool for detecting chicory within 5 min. This “low-cost” sensing could facilitate accessible screening of coffee samples, enhancing quality within the industry and ultimately safeguarding consumer interests.
- 9 July 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (28) , 31059-31065
Open AccessWhat’s in My Coffee? Do-It-Yourself Testing for Chicory Adulteration Using Particle Trapping in Stencil-Based Paper Devices
Our study introduces a cost-effective Do-It-Yourself (DIY) method for detecting chicory adulteration in coffee powder via the Shake & Invert approach integrated with a particle trapping mechanism. Coffee powders of different sizes were blended with chicory in distinct proportions. A bioline layer was employed as an adhering agent to selectively capture chicory on a laminated paper-based device. This selective adhesion is attributed primarily to the differences in surface morphology between the coffee and chicory particles. The texture and structural arrangement of the particles play crucial roles in determining their interaction with the bioline-coated surface. SEM imaging provided further insight into these differences, revealing that chicory possesses rough and distinctive fiber-like structures, whereas the coffee particles have a uniform plate-like surface. These structural characteristics are believed to enhance its adhesion toward the bioline-coated paper, resulting in superior adhesion compared with that of the coffee particles. Our developed approach exhibited a limit of detection (LOD) at a coffee-to-chicory ratio of 90:10. This understanding of the distinct physical properties of chicory and coffee underscores the effectiveness of our adhesive testing method, indicating its potential as a robust tool for detecting chicory within 5 min. This “low-cost” sensing could facilitate accessible screening of coffee samples, enhancing quality within the industry and ultimately safeguarding consumer interests.
- Open Access
- 5 July 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (8) , 1-27
Microfluidic paper–based analytical extraction devices (µPAEDs): a cost-effective and portable solution for biomarkers, contaminants and VOC detection
The human body relies on various biological and environmental cues, and regulatory processes for basic functioning and maintenance of health. Thus, by monitoring these cues, which include biomarkers and chemical contaminants, scientists and health professionals can prioritize the health, well-being, and longevity of the general population. These analytes are found in biological and other fluids and are usually extracted using conventional extraction methods like liquid–liquid or solid-phase extraction. Until recently, these methods were used in tandem with conventional detection techniques like LC–MS/MS and GC–MS/MS. However, this inept combination proves to be disadvantageous for the general population due to its higher costs, requirement of specialized equipment and experienced personnel, usage of several organic and environmentally harmful reagents, and a centralized approach. Thus, recently there has been a rise in the usage of microfluidics, particularly µPADs and conventional extraction techniques. By capitalizing on the multifarious advantages of µPADs, including affordability, miniaturization, and dispensable equipment, researchers have developed all-in-one microfluidic paper–based analytical extraction devices (µPAEDs). This approach mitigates the risks associated with the former and improves costs, transportability, and accessibility. Additionally, this novel approach has also been applied to non-invasive detection of volatile organic compounds (VOCs). In this review, we highlight the advancements of µPAEDs to detect myriads of biomarkers and chemical contaminants in samples like blood, breath, and water. Graphical Abstract
- 5 July 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (8) , 1-27
Open AccessMicrofluidic paper–based analytical extraction devices (µPAEDs): a cost-effective and portable solution for biomarkers, contaminants and VOC detection
The human body relies on various biological and environmental cues, and regulatory processes for basic functioning and maintenance of health. Thus, by monitoring these cues, which include biomarkers and chemical contaminants, scientists and health professionals can prioritize the health, well-being, and longevity of the general population. These analytes are found in biological and other fluids and are usually extracted using conventional extraction methods like liquid–liquid or solid-phase extraction. Until recently, these methods were used in tandem with conventional detection techniques like LC–MS/MS and GC–MS/MS. However, this inept combination proves to be disadvantageous for the general population due to its higher costs, requirement of specialized equipment and experienced personnel, usage of several organic and environmentally harmful reagents, and a centralized approach. Thus, recently there has been a rise in the usage of microfluidics, particularly µPADs and conventional extraction techniques. By capitalizing on the multifarious advantages of µPADs, including affordability, miniaturization, and dispensable equipment, researchers have developed all-in-one microfluidic paper–based analytical extraction devices (µPAEDs). This approach mitigates the risks associated with the former and improves costs, transportability, and accessibility. Additionally, this novel approach has also been applied to non-invasive detection of volatile organic compounds (VOCs). In this review, we highlight the advancements of µPAEDs to detect myriads of biomarkers and chemical contaminants in samples like blood, breath, and water. Graphical Abstract