Varun Lingaiah Kopparthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Varun Lingaiah Kopparthy has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Eric J. Guilbeau
Department of Biomedical Engineering, Louisiana Tech University, Ruston, LA, USA
4 shared publications- Gergana G. Nestorova
School of Biological Sciences, Louisiana Tech University, Ruston, LA, USA
4 shared publications Niel D. Crews
Institute for Micromanufacturing (IfM) Louisiana Tech University Ruston Louisiana
4 shared publicationsDavid Erickson
Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY
2 shared publications- David Erickson
Cornell University
2 shared publications - Eric J. Guilbeau
Louisiana Tech University
2 shared publications
Latest Publications
- Open Access
- 19 May 2023
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 11 (5S) , 78
124. Porcine Model for Superior Epigastric Artery Based Perforator Flap in Reconstructive Microsurgery
- 19 May 2023
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 11 (5S) , 78
Open Access124. Porcine Model for Superior Epigastric Artery Based Perforator Flap in Reconstructive Microsurgery
- Open Access
- 21 June 2022
- Published by American Society of Hematology in Blood Advances
- Vol. 6 (12) , 3650-3654
Simplified detection of Epstein-Barr virus for diagnosis of endemic Burkitt lymphoma
Andrea L Garner, Julio Alvarez, Caitlyn Genovese, Ryan Snodgrass, Varun Kopparthy, David Erickson, Ethel Cesarman; Simplified Detection of Epstein-Barr Virus fo
- 21 June 2022
- Published by American Society of Hematology in Blood Advances
- Vol. 6 (12) , 3650-3654
Open AccessSimplified detection of Epstein-Barr virus for diagnosis of endemic Burkitt lymphoma
Andrea L Garner, Julio Alvarez, Caitlyn Genovese, Ryan Snodgrass, Varun Kopparthy, David Erickson, Ethel Cesarman; Simplified Detection of Epstein-Barr Virus fo
- 20 January 2020
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (5) , 1525-1532
A versatile oscillating‐flow microfluidic PCR system utilizing a thermal gradient for nucleic acid analysis
We report the development of a versatile system based on the oscillating‐flow methodology in a thermal gradient system for nucleic acid analysis. Analysis of DNA and RNA samples were performed in the device, without additional temperature control and complexity. The technique reported in this study eliminates the need for predetermined fluidic channels for thermocycles, and complexity involved with additional incubation steps required for RNA amplification. A microfluidic device was fabricated using rapid prototyping by simply sandwiching dual side adhesive Kapton tape and a polydimethylsiloxane spacer between glass microscope slides. Amplification of the 181‐bp segment of a viral phage DNA (ΦX174) and B2M gene in human RNA samples was demonstrated using the system. The developed system enables simultaneous acquisition of amplification and melt curves, eliminating the need for postprocessing. A direct comparison between the oscillating‐flow system and a commercial real‐time polymerase chain reaction (PCR) instrument showed complete agreement in PCR data and improved sample‐to‐result time by eliminating an additional 30 min melt curve step required in commercial PCR systems.
- 20 January 2020
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (5) , 1525-1532
A versatile oscillating‐flow microfluidic PCR system utilizing a thermal gradient for nucleic acid analysis
We report the development of a versatile system based on the oscillating‐flow methodology in a thermal gradient system for nucleic acid analysis. Analysis of DNA and RNA samples were performed in the device, without additional temperature control and complexity. The technique reported in this study eliminates the need for predetermined fluidic channels for thermocycles, and complexity involved with additional incubation steps required for RNA amplification. A microfluidic device was fabricated using rapid prototyping by simply sandwiching dual side adhesive Kapton tape and a polydimethylsiloxane spacer between glass microscope slides. Amplification of the 181‐bp segment of a viral phage DNA (ΦX174) and B2M gene in human RNA samples was demonstrated using the system. The developed system enables simultaneous acquisition of amplification and melt curves, eliminating the need for postprocessing. A direct comparison between the oscillating‐flow system and a commercial real‐time polymerase chain reaction (PCR) instrument showed complete agreement in PCR data and improved sample‐to‐result time by eliminating an additional 30 min melt curve step required in commercial PCR systems.
- Open Access
- 8 February 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
Oscillating-flow Thermal Gradient PCR
We report the development of a versatile system based on oscillating-flow methodology in a thermal gradient system for nucleic acid analysis. Analysis of DNA and RNA samples were performed in the device, without additional temperature control and complexity. The technique reported in this study eliminates the need for predetermined fluidic channels for thermocycles, and complexity involved with additional incubation steps required for RNA amplification. A microfluidic device was fabricated using rapid prototyping by simply sandwiching dual side adhesive Kapton tape and a PDMS spacer between glass microscope slides. Amplification of the 181-bp segment of a viral phage DNA (ΦX174) and B2M gene in human RNA samples was demonstrated using the system. The developed system enables simultaneous acquisition of amplification and melt curves, eliminating the need for post-processing.
- 8 February 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
Open AccessOscillating-flow Thermal Gradient PCR
We report the development of a versatile system based on oscillating-flow methodology in a thermal gradient system for nucleic acid analysis. Analysis of DNA and RNA samples were performed in the device, without additional temperature control and complexity. The technique reported in this study eliminates the need for predetermined fluidic channels for thermocycles, and complexity involved with additional incubation steps required for RNA amplification. A microfluidic device was fabricated using rapid prototyping by simply sandwiching dual side adhesive Kapton tape and a PDMS spacer between glass microscope slides. Amplification of the 181-bp segment of a viral phage DNA (ΦX174) and B2M gene in human RNA samples was demonstrated using the system. The developed system enables simultaneous acquisition of amplification and melt curves, eliminating the need for post-processing.
- 6 February 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (5) , 728-737
Point of care technologies for sepsis diagnosis and treatment
Development of new point of care tools for sepsis has the potential to improve diagnostic speed and accuracy, leading to prompt administration of appropriate therapeutics, thereby reducing healthcare costs and improving patient outcomes.
- 6 February 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (5) , 728-737
Point of care technologies for sepsis diagnosis and treatment
Development of new point of care tools for sepsis has the potential to improve diagnostic speed and accuracy, leading to prompt administration of appropriate therapeutics, thereby reducing healthcare costs and improving patient outcomes.
- 29 December 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 133, 572-580
Detecting thermal asymmetry in microfluidics for sensor applications: Critical design considerations and optimization
- 29 December 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 133, 572-580
Detecting thermal asymmetry in microfluidics for sensor applications: Critical design considerations and optimization
- 11 September 2018
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 2 (9) , 657-665
A portable device for nucleic acid quantification powered by sunlight, a flame or electricity
A decentralized approach to diagnostics can decrease the time to treatment of infectious diseases in resource-limited settings, yet most modern diagnostic tools require stable electricity and are not portable. Here, we describe a portable device for isothermal nucleic acid quantification that can operate with power from electricity, sunlight or a flame, and that can store heat from intermittent energy sources for operation when electrical power is not available or reliable. We deployed the device in two Ugandan health clinics, where it successfully operated through multiple power outages, with equivalent performance when powered via sunlight or electricity. A direct comparison between the portable device and commercial quantitative polymerase chain reaction machines for samples from 71 Ugandan patients (29 of which were tested in Uganda) for the presence of Kaposi’s sarcoma-associated herpesvirus DNA showed 94% agreement, with the four discordant samples having the lowest concentration of the herpesvirus DNA. The device’s flexibility in power supply provides a needed solution for on-field diagnostics.
- 11 September 2018
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 2 (9) , 657-665
A portable device for nucleic acid quantification powered by sunlight, a flame or electricity
A decentralized approach to diagnostics can decrease the time to treatment of infectious diseases in resource-limited settings, yet most modern diagnostic tools require stable electricity and are not portable. Here, we describe a portable device for isothermal nucleic acid quantification that can operate with power from electricity, sunlight or a flame, and that can store heat from intermittent energy sources for operation when electrical power is not available or reliable. We deployed the device in two Ugandan health clinics, where it successfully operated through multiple power outages, with equivalent performance when powered via sunlight or electricity. A direct comparison between the portable device and commercial quantitative polymerase chain reaction machines for samples from 71 Ugandan patients (29 of which were tested in Uganda) for the presence of Kaposi’s sarcoma-associated herpesvirus DNA showed 94% agreement, with the four discordant samples having the lowest concentration of the herpesvirus DNA. The device’s flexibility in power supply provides a needed solution for on-field diagnostics.
- 16 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (3) , 434-439
Microfab in a Microwave Oven: Simultaneous Patterning and Bonding of Glass Microfluidic Devices
We report a new method for fabrication of research-grade glass microfluidic devices using a household microwave oven. The transformative step in this technique is the formation of the microchannel and fusion bonding of the glass layers in a single step. This is demonstrated here using a non-photolithographic technique for both high aspect ratio rectangular and circular cross-section microchannels. In this paper, the microfluidic devices are fabricated utilizing a thin paper cutout as the sacrificial channel layer, glass blanks, and a microwave kiln sold commercially for arts and crafts. Glass microfluidic devices are fabricated in a microwave oven in as short as 2 min.
- 16 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (3) , 434-439
Microfab in a Microwave Oven: Simultaneous Patterning and Bonding of Glass Microfluidic Devices
We report a new method for fabrication of research-grade glass microfluidic devices using a household microwave oven. The transformative step in this technique is the formation of the microchannel and fusion bonding of the glass layers in a single step. This is demonstrated here using a non-photolithographic technique for both high aspect ratio rectangular and circular cross-section microchannels. In this paper, the microfluidic devices are fabricated utilizing a thin paper cutout as the sacrificial channel layer, glass blanks, and a microwave kiln sold commercially for arts and crafts. Glass microfluidic devices are fabricated in a microwave oven in as short as 2 min.
- 29 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (20) , 6510-6514
Highly Sensitive Microfluidic Chip Sensor for Biochemical Detection
Chip calorimetry offers a power tool for fast and high throughput analysis of biochemical process. However, it is challenging to realize an inexpensive, easy to fabricate microfluidic chip-based calorimeter with high sensitivity. This paper describes the design of a novel, highly sensitive, and continuous flow microfluidic chip sensor with an integrated antimony (Sb)-bismuth (Bi) thin-film thermopile heat detection element. The geometry and the design of the microfluidic device facilitate hydrodynamic flow focusing, and the integration and design of the thermopile sensor into the microfluidic device eliminates the need for reference temperature control. The device contains a single flow channel that is 120 μm high and 10-mm wide with two fluid inlets and one fluid outlet. An Sb-Bi thin film thermopile is fabricated on the inner surface of the bottom channel wall using thermal evaporation and was passivized with a 3 μm SU-8 photoresist layer. The device has been successfully used to measure the dynamic temperature changes resulting from heat generation following the mixing of glycerol and water. The effect of flow rates on the sensor's response was measured. The sensor can detect dynamic temperature changes in the order of 10-6 K. The limit of detection of heat power of the device was calculated to be 8.8 pW. With the obtained remarkable sensitivity and heat power detection limit, the microfluidic chip sensor can potentially be used to investigate biochemical processes, such as enzyme-catalysed reactions, and metabolic activity of cells.
- 29 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (20) , 6510-6514
Highly Sensitive Microfluidic Chip Sensor for Biochemical Detection
Chip calorimetry offers a power tool for fast and high throughput analysis of biochemical process. However, it is challenging to realize an inexpensive, easy to fabricate microfluidic chip-based calorimeter with high sensitivity. This paper describes the design of a novel, highly sensitive, and continuous flow microfluidic chip sensor with an integrated antimony (Sb)-bismuth (Bi) thin-film thermopile heat detection element. The geometry and the design of the microfluidic device facilitate hydrodynamic flow focusing, and the integration and design of the thermopile sensor into the microfluidic device eliminates the need for reference temperature control. The device contains a single flow channel that is 120 μm high and 10-mm wide with two fluid inlets and one fluid outlet. An Sb-Bi thin film thermopile is fabricated on the inner surface of the bottom channel wall using thermal evaporation and was passivized with a 3 μm SU-8 photoresist layer. The device has been successfully used to measure the dynamic temperature changes resulting from heat generation following the mixing of glycerol and water. The effect of flow rates on the sensor's response was measured. The sensor can detect dynamic temperature changes in the order of 10-6 K. The limit of detection of heat power of the device was calculated to be 8.8 pW. With the obtained remarkable sensitivity and heat power detection limit, the microfluidic chip sensor can potentially be used to investigate biochemical processes, such as enzyme-catalysed reactions, and metabolic activity of cells.