Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Si-Wook Lee has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing Medical Students’ Disease Detection Skills: Leveraging Artificial Intelligence Software for Diagnosing Developmental Dysplasia Using Ultrasound Imaging

    by Yu-Ran Heo, Jun-Chae Lee, Yeon-Kyoung Ko, Seung-Bo Lee, Jae-Ho Lee, Si-Wook Lee

    Background: Ultrasound is the gold standard for the screening of developmental dysplasia of the hip (DDH). However, there are several problems in overcoming the learning curve of technical skills required to detect DDH using ultrasound. Thus, several attempts have been made to assist in the detection of DDH using artificial intelligence (AI) software (SW). This study aimed to evaluate the efficacy of AI in DDH ultrasound screening to aid medical students in the diagnosis of DDH. Method: A Mask R-CNN-based detection model was developed to identify six key points and measure the alpha and beta angles, as well as containment, following Graf’s method. Fifty-three second-year medical students assessed 38 DDH screening ultrasound images from 28 patients twice: first through self-measurement after brief training and then using AI-assisted measurement, where key points were refined based on AI predictions. The gold standard for comparison was the measurement performed by an experienced orthopedic surgeon. Results: AI assistance significantly improved agreement with the expert reference for all three measurements. The proportion of students classified in the excellent agreement category increased from 26.4% to 81.1% for the alpha angle, from 67.9% to 86.8% for the beta angle, and from 56.6% to 84.9% for containment. The mean ICC increased from 0.593 to 0.855 for the alpha angle, from 0.760 to 0.892 for the beta angle, and from 0.722 to 0.882 for containment. Wilcoxon signed-rank tests demonstrated significant improvements in all three measurements (all p < 0.001). Conclusions: AI-assisted ultrasound measurement may improve agreement with expert measurements among novice users assessing DDH. This approach may have potential as a supportive tool for DDH screening and educational training by reducing the learning curve associated with ultrasound-based measurement.

  • Open Access

    Personalized 3D-Printed Prostheses for Bone Defect Reconstruction After Tumor Resection in the Foot and Ankle

    by Chang-Jin Yon, Byung-Chan Choi, Jung-Min Lee, Si-Wook Lee

    Three-dimensional (3D)-printing technology is revolutionizing orthopedic oncology by providing precise, customized solutions for complex bone defects following tumor resection. Traditional modular endoprostheses are prone to complications such as fretting corrosion and implant failure, underscoring the need for innovative approaches. This case series reports on three patients treated with 3D-printed, patient-specific prostheses and cutting guides. Preoperative CT and MRI data were used to design implants tailored to each patient’s anatomy, manufactured using electron beam melting technology with a titanium–aluminum–vanadium alloy. Functional outcomes showed significant improvements: in Case I, AOFAS improved from 71 to 96, and VAS decreased from 6 to 1; in Case II, AOFAS increased from 65 to 79, and VAS decreased from 5 to 3. Radiographic evaluations demonstrated stable prosthesis placement and early evidence of bone integration in Cases I and II, while in Case III, localized disease control was achieved before systemic progression. This case series highlights the transformative potential of 3D-printed prostheses in addressing the challenges of reconstructing anatomically complex defects. By enabling precise tumor resection and improving functional outcomes, this approach can advance current practices in orthopedic oncology. Further research should explore larger cohorts and use cost-effectiveness analyses to validate these findings and facilitate broader clinical adoption.


  • Open Access

    Comparison of Biocompatibility of 3D-Printed Ceramic and Titanium in Micropig Ankle Hemiarthroplasty

    by Si-Wook Lee, Donghyun Lee, Junsik Kim, Sanghyun An, Chul-Hyun Park, Jung-Min Lee, Chang-Jin Yon, Yu-Ran Heo

    Background: Ankle arthritis is a common degenerative disease that progresses as cartilage damage in the lower tibia and upper talus progresses, resulting in loss of joint function. In addition to typical arthritis, there is also structural bone loss in the talus due to diseases such as talar avascular necrosis. Total talus replacement surgery is the procedure of choice in end-stage ankle arthritis and consists of a tibial, talar component and an insert. However, in cases of severe cartilage and bone damage to the talar bone with less damage to the tibial cartilage, a talar component hemiarthroplasty may be considered. Although the application of total talus replacement surgery using ceramics has been studied, reports on the application of metal 3D printing technology are limited. We aimed to investigate the feasibility of partial talar components using ceramic and titanium 3D printing technology in terms of biocompatibility and stability through animal experiments. Methods: Preoperative 3D CT was acquired and converted to STL files to fabricate a partial talus component for ankle hemiarthroplasty using ceramic and titanium. Six minipigs with an average age of 17 months were implanted with three ceramic (C-group) and three titanium talar components (T-group) in the hind limb ankle joint. The surgery was performed under anesthesia in a sterile operating room and was performed by two experienced foot and ankle specialist orthopedic surgeons. Blood analysis and CT were performed before surgery and every month for 3 months after surgery to assess the extent of inflammatory response and physical stability, sacrifices were performed 3 months after surgery, and H&E staining and micro-CT analysis were performed to compare histological biocompatibility. A grading score was calculated to semi-quantitative assess and compare the two groups. Results: In the postsurgical evaluation, blood analysis revealed that both groups had increased white blood cell counts on the postoperative day after surgery. The white blood cell count increased more in the titanium group (1.85-fold) than in the ceramic group (1.45-fold). After 3 months, all values normalized. During the study, CT analysis confirmed that all artificial samples were displaced from their initial positions. In micro-CT analysis, the adhesive tissue score of the ceramic artificial sample was better than that of the titanium sample (average threshold = 3027.18 ± 405.92). In histologic and grading scores for the inflammatory reactions, the average inflammation indices of the ceramic and titanium groups were 2.0 and 1.21, respectively. Also, the average grade score confirmed based on the results of fibrous tissue proliferation and new blood vessels was 18.4 in the ceramic application group and 12.3 in the titanium application group. Conclusions: In conclusion, both titanium and ceramics have excellent biocompatibility for artificial joints, and ceramic materials can be used as novel artificial joints. Further research on the strength and availability of these ceramics is required.


  • Open Access

    Supernumerary Head of the Biceps Brachii Muscle Influences the Topography of the Coracobrachialis and Biceps Brachii Muscles

    by Yu-Ran Heo, Hyunsu Lee, Si-Wook Lee, Beom-Soo Kim, Hong-Tae Kim, Jae-Ho Lee

    Background/Objectives: Anatomical variations in the biceps brachii muscle (BBM) are extremely frequent, leading to developmental and clinical implications. We studied the topography of the BBM and analyzed its correlations with other structures in the brachial region. Methods: A total of 103 cadaveric upper extremities were dissected. The length of the upper extremities was utilized as a reference line. The origin and insertion of the BBM, the coracobrachialis muscle (CBM), and the related neurovascular system were evaluated. Results: Each variable was calculated as a percentile and compared according to the presence of the considered variation; in particular, a supernumerary head of the BBM was found in 12/103 (11.65%) of upper extremities and was associated with a longer upper limb (506.25 ± 32.55 mm vs. 484.27 ± 30.41 mm, p = 0.022). When the variables were standardized by the length of the upper limb, the accessory head of the BBM was associated with the distal insertion point of the CBM (28.18 ± 3.54% vs. 30.59 ± 2.94%, p = 0.011) and BBM length (55.11 ± 2.17% vs. 58.18 ± 3.72%, p = 0.006). Other variables did not present significant differences with respect to the presence of the supernumerary head of the BBM. Conclusions: BBM variations may affect the topography of other structures, such as the length of the upper extremities, insertion of the CBM, and length of the BBM. Further studies are required to elucidate its clinical implications.


  • Open Access

    Pathomechanism of Triangular Fibrocartilage Complex Injuries in Patients with Distal-Radius Fractures: A Magnetic-Resonance Imaging Study

    by Beom-Soo Kim, Chul-Hyun Cho, Kyung-Jae Lee, Si-Wook Lee, Seok-Ho Byun

    Injury to the triangular fibrocartilage complex (TFCC) is one of the most common complications following a fracture of the distal radius. In this study, an examination of TFCC injuries in patients with distal-radius fractures was conducted using magnetic-resonance imaging (MRI); the aim of the study was to analyze the prevalence of TFCC injury as well as to suggest acceptable radiologic parameters for use in prediction of the injury pattern. Fifty-eight patients with distal-radius fractures who underwent MRI prior to undergoing open-reduction surgery between April 2020 and July 2021 were included in this study. An analysis of various radiologic parameters, the fracture type, and the MRI classification of TFCC injuries was performed. Radiologic parameters were used in the evaluation of distal radioulnar joint (DRUJ), radial shortening, and the dorsal angularity of the fracture. All of the patients in this study had definite traumatic TFCC injuries. A statistical relationship was observed between the radial length gap between the intact wrist and the injured wrist, which represents relative radial shortening, and the pattern of TFCC injury. In conclusion, the shortening of the distal radius, causing peripheral soft tissue of the ulnar side to become tauter, is highly relevant with regard to the pattern of TFCC injury. However, because no data on the clinical outcome were utilized in this study, it is lacking in clinical perspective. The conduct of further studies on patients’ clinical outcome will be necessary.


  • Open Access

    The Comparison of Lower Extremity Length and Angle between Computed Radiography-Based Teleoroentgenogram and EOS® Imaging System

    by Kwang-Rak Park, Jae-Ho Lee, Dae-Soo Kim, Ho Ryu, Jaeho Kim, Chang-Jin Yon, Si-Wook Lee

    Background and objectives: The differences between computed radiography-based teleoroentgenograms (CR-based teleoroentgenograms) and an EOS® imaging system were evaluated by measuring lower extremity lengths and alignments. Materials and methods: The leg length [L], femur length [F], tibia length [T], and hip–knee–ankle (HKA) angle were measured in 101 patients with lower extremity disease by a CR-based teleoroentgenogram with computed radiography and an EOS®. The additive length of the femoral and tibial segments (F + T) was determined by adding the two length values. Then, the differences among all five parameters between the two techniques were analyzed. The magnification (mm) was calculated by subtracting the length measurements on the EOS® from those in the scanogram. Furthermore, the magnification percentage (%) was calculated by dividing the magnification with the measurements on the EOS®. Results: The magnification errors (mean ± standard deviation), when comparing both right and left sides, were 7.80 ± 1.41%, 7.3 ± 6.01%, 5.16 ± 1.25%, and 6.45 ± 0.94% for L, F, T, and F + T, respectively. For limb length, the CR-based teleoroentgenogram had an average magnification of 6.8% (range, 5.2 to 7.8%) compared to the EOS® imaging. The two groups displayed a statistical difference (p < 0.01), except for the HKA angle. Conclusions: The CR-based teleoroentgenogram had a magnification of about 6.8% compared to the EOS® imaging system in evaluating lower extremity length. Therefore, more attention must be given to CR-based teleoroentgenograms to correct angular deformities.


  • Open Access

    A Simple Method to Locate the Master Knot of Henry Using the Correlation between the Flexor Tendon Length Parameter and the Foot Length

    by Kwang Rak Park, Won-Jin Park, Si-Wook Lee, Hongtae Kim, Hyunsu Lee, Jae-Ho Lee

    The precise location of the Master Knot of Henry (MKH) has important clinical significance, but its anatomical definition has not been agreed upon. The purpose of this study is to present a linear regression equation for predicting length variables based on foot length, by evaluating the correlation of length variables related to flexor hallucis longus (FHL) and flexor digitorum longus (FDL), with respect to the location of the MKH. A total of 95 limbs were dissected from 48 adult cadavers, and were fixed in formalin. Measurements were made for the length parameter, with reference to the landmark. The relevance between length variables was analyzed through simple correlation analysis and linear regression analysis. The foot length was 213.69 ± 17.53 mm, MKH-great toe distal phalanx was 140.16 ± 14.69 mm, MKH-FHL insertion was 124.55 ± 13.46 mm, MKH-little toe distal phalanx was 121.79 ± 13.41 mm, MKH-FDL little toe insertion was 109.07 ± 14.16 mm, and the FHL-FDL angle was 33.15 ± 5.39. The correlation coefficient between all the length variables for foot length showed a high positive correlation. We derived a regression equation that can predict the length of each variable. This regression formula is considered to be highly useful because it can estimate the positional relationship of the MKH relatively simply.


  • Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study

    by Byung-Woo Min, Ki-Cheor Bae, Chul-Hyun Cho, Eun-Suck Son, Kyung-Jae Lee, Si-Wook Lee

    Background Outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic arthritis due to a higher rate of cup loosening and osteolysis. We, therefore, investigated whether highly cross-linked polyethylene liners positively impact outcomes of THA in patients with posttraumatic osteoarthritis after acetabular fracture. Methods We retrospectively evaluated 39 patients with previous acetabular fracture who underwent THA using highly cross-linked polyethylene liner after a mean 8.5 year follow-up. All procedures were performed at a single institution by a single surgeon using the same type of THA implants. Wear measurements were performed using a computer-assisted PolyWare software. Osteolysis was evaluated with use of radiography and computed tomography. Results The mean preoperative Harris hip score was 44.4 points, which improved to 93.1 points at final follow-up. Neither femoral nor acetabular components displayed mechanical loosening and no components had been revised. Radiographs and CT scans did not demonstrate osteolysis. The mean linear wear was 0.043 mm/y (range 0–0.098 mm/y). With the data available, univariate regression analysis suggests that age, gender, weight, initial fracture type, the duration of follow-up, activity level, liner thickness, acetabular cup inclination, and the necessity of bone graft had no influence on liner penetration. Conclusion While the long-term effects of the polyethylene particles from highly cross-linked polyethylene remain unknown, implant survivorship and wear data in this study are promising for this high-risk population. Our encouraging results support the continued use of this type of polyethylene in patients after acetabular fractures. Level of Evidence Level IV Therapeutic study.


  • Open Access

    Clinical Characteristics of Mitochondrial DNA Copy Number in Osteonecrosis of the Femoral Head

    by Si-Wook Lee, Kyung-Jae Lee, Beom-Soo Kim, Hyuk-Jun Kwon, Jae-Ho Lee

    Background and objectives: Alterations in mitochondrial DNA (mtDNA) have been observed and studied in various diseases. However, the clinical value of the mtDNA copy number (mtDNA-CN) alterations in osteonecrosis of the femoral head (ONFH) is poorly understood. In the present study, we investigated whether alterations in mtDNA-CNs are associated with clinicopathological parameters in ONFH. Materials and methods: MtDNA-CNs in the synovial tissue of 34 patients with ONFH and 123 control tissues (femoral neck fracture) were measured using quantitative real-time PCR. The present study then analyzed the correlation between the mtDNA-CN and the clinicopathological characteristics of ONFH and fracture patients. Results: The average mtDNA-CN (mean ± standard deviation) was 23.82 ± 22.37 and 25.04 ± 24.27 in ONFH and control tissues, respectively, and was not significantly different between the groups (p = 0.792). The mtDNA-CN was positively associated with age (27.7% vs. 45.9%, p = 0.018) and negatively associated with the erythrocyte sedimentation rate (ESR) (11.8% vs. 39.7%, p = 0.024) in all of the samples. The study also found further associations with age (22.2% vs. 68.8%, p = 0.014), gender (30.0% vs. 64.3%, p = 0.048), and ESR (0% vs. 57.7%, p = 0.043) in ONFH. Conclusions: in this study, we demonstrated that mtDNA-CN might be a significant marker for predicting clinical characteristics in ONFH.