CSChengjun Sun

Chengjun Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengjun Sun has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Yang Li

    West China School of Public Health, Sichuan University, Chengdu, People's Republic of China

    4 shared publications
  • Feng Xue

    West China School of Public Health, Sichuan University, No. 17, Section 3, South Renmin Road, Chengdu 610041, Sichuan, People's Republic of China

    2 shared publications
  • Jiangtao Hu

    Sichuan Entry-Exit Inspection and Quarantine Bureau, No. 28, Fourth Section, South 1st Ring Road, Chengdu 610041, Sichuan, People's Republic of China

    2 shared publications
  • Ying Shi

    Sichuan University

    2 shared publications
  • Yong Xue

    West China School of Public Health, Sichuan University, No.17, Section 3, South Renmin Road, Chengdu 610041, China

    2 shared publications
  • Yuan Wang

    West China School of Public Health, Sichuan University, Chengdu 610041, China

    2 shared publications

Latest Publications

  • Open Access

    Thyroid volume, goiter prevalence, and selenium levels in an iodine-sufficient area: a cross-sectional study

    by Yang Liu, Hui Huang, Jing Zeng, Chengjun Sun

    Background: Selenium (Se) is a necessary element for the biosynthesis of thyroid hormones. We investigated the relationship between selenium status, thyroid volume, and goiter in a cross-sectional study in an iodine-sufficient area. Methods: We selected residents of Chengdu (over 18 years old and living in the city for more than 5 years) using a stratified cluster sampling technique. Fifteen hundred subjects were selected for the study, which involved a questionnaire survey, physical examination, thyroid ultrasound, serum thyroid function test, and determination of serum selenium level. Thyroid volume was calculated from the thickness, width, length, and a corrective factor for each lobe. Ultimately, 1,205 subjects completed the investigation and were included in our study. Additionally, 80 school-age children were selected to provide urine samples for urinary iodine analysis. We analyzed the data using appropriate nonparametric and parametric statistical tests. Results: The median urinary iodine value was 184 μg/L in school-age children, indicating iodine sufficiency. The median serum selenium level of the 1,205 subjects was 52.63 (interquartile range [IQR] : 40.40-67.00) μg/L. The median thyroid volume was 9.93 (IQR: 7.71-12.57) mL; both log-transformed serum selenium and log-transformed thyroid volume were Gaussian distributions (P = .638 and P = .046, respectively). The prevalences of goiter and thyroid nodules were 8.8% and 18.6%. The prevalences of positive thyroid autoantibodies, thyroperoxidase autoantibodies and thyroglobulin autoantibodies were 16.7%, 12.0%, and 11.1%, respectively. In the general linear regression model, there were positive associations between serum selenium and age, and body mass index. We found no association between serum selenium and thyroid-stimulating hormone. In simple linear regression analyses, we found no association between thyroid volume and serum selenium. There were no significant differences in serum selenium between persons with or without goiter. Serum selenium was not a risk factor for goiter. Conclusion: In our study population, serum selenium was neither associated with thyroid volume nor with goiter in an iodine-sufficient area. More studies should be conducted by following non-goitrous persons over time and monitoring their selenium status.


  • Simultaneous determination of seven preservatives in cosmetics by dispersive liquid–liquid microextraction coupled with high performance capillary electrophoresis

    by Yong Xue, Na Chen, Chunying Luo, Xixi Wang, Chengjun Sun

    A simple, rapid, inexpensive and efficient method based on dispersive liquid–liquid microextraction (DLLME) coupled with high performance capillary electrophoresis (HPCE) has been developed for the extraction and determination of methylparaben (MP), ethylparaben (EP), propylparaben (PP), butylparaben (BP), sorbic acid (SOA), benzoic acid (BA), and salicylic acid (SA) in cosmetic products. A dispersive solution composed of 50 μL trichloromethane and 0.45 mL isopropyl alcohol was used to extract the target analytes from acidified sample solution quantitatively in the DLLME procedure. A suitable amount of lower layer was transferred into a vial and evaporated to dryness under nitrogen gas. The residue was reconstituted in methanol–water (20 : 80, v/v) solution, and separated using bare fused-silica capillary (50 μm i.d., 50 cm of total length, and 41 cm effective length) and detected at 230 nm. Urobenzoic acid was used as the internal standard. The calibration curves were linear in the range of 0.05 to 5.0 μg mL−1 for MP and SA, and 0.025 to 5.0 μg mL−1 for the rest with the coefficients of correlation ranging from 0.9978 to 0.9995. The limits of detection were in the range of 0.200–0.375 mg kg−1 with enrichment factors ranging from 41 to 133 for all target analytes. Recoveries of the method were in the range of 71.1–112.6%, with the intraday RSDs and interday RSDs in the range of 2.22–4.51% and 3.05–4.89%, respectively. This method has been successfully applied for analysis of the preservatives in different samples of cosmetic.


  • A fast and easy GC-MS/MS method for simultaneous analysis of 73 pesticide residues in vegetables and fruits

    by Dan Lu, Yuan Yang, Xiaofei Luo, Chengjun Sun

    A simple and easy method was established for the simultaneous determination of 73 pesticide residues in vegetables and fruits by gas chromatography-tandem mass spectrometry (GC-MS/MS). After samples were ultrasonically extracted with hexane and centrifuged, the analytes in sample solution were separated with DB-5MS column (30 m × 0.25 mm, 0.25 μm). Qualitative determination of the analytes was based on characteristic ion pairs and retention time using multiple reactions monitoring (MRM) mode. The mixed-matrices standard curves were used for quantification. The calibration curves were mostly in the range of 10–1000 μg L−1. The limits of detection (LODs) of the method were from 0.012 to 18.8 μg kg−1 and limits of quantification (LOQs) were in the range of 0.042–61.8 μg kg−1, which were much lower than the maximum residue levels (MRLs) established by European legislation. The average recoveries of the method ranged from 86.7% to 124%, 85.6% to 117%, 89.2% to 111% at three spiked levels of 0.10, 0.20, 0.50 mg kg−1 in leek samples, with relative standard deviations (RSDs) of 1.84% to 11.3%, 2.40% to 9.50%, 0.79% to 8.30%, respectively. Additionally, the method was more favorable than gas chromatography-mass spectrometry (GC-MS) in the analysis of 15 spiked samples, including ten vegetables and five fruits. Three pesticides were detected in the samples of celery and apple by the established method and the GC-MS method.


  • Simultaneous determination of eleven preservatives in foods using ultrasound-assisted emulsification micro-extraction coupled with gas chromatography-mass spectrometry

    by Jinling Yang, Dan Li, Chengjun Sun

    A simple and rapid method based on ultrasound-assisted emulsification micro-extraction (USAEME) coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and validated for simultaneous determination of eleven preservatives in foods, including benzoic acid, sorbic acid, dehydroacetic acid, dimethyl fumarate, benzyl alcohol, methyl benzoate, o-phenylphenol, methylparaben, ethylparaben, propylparaben and butylparaben. Mandelic acid and anthracene were used as internal standards. A mixed solvent of dichloromethane and ethyl acetate in the ratio of 9 : 1(v/v) was used to extract the target analytes from acidified sample solution quantitatively in the USAEME procedure. The enrichment factors (EF) ranged from 88 to 141. The linear ranges of the method were between 0.062 μg mL−1 to 100 μg mL−1 with the correlation coefficients varied from 0.9994 to 0.9999. The limits of detection (LODs) were 0.025 mg kg−1 to 1.53 mg kg−1. The intra-day and inter-day precisions (RSDs) were less than 4.96% and 6.79%, respectively. The mean recoveries ranged from 90.5% to 104.6%. The proposed method has been successfully applied to the determination of preservatives in different food samples including cake, soy sauce, vinegar, jam, ham, beverage, pickle and bean paste.


  • Open Access

    A GC–EI-MS-MS Method for Simultaneous Determination of Seven Adulterants in Slimming Functional Foods

    by Yang Li, Hong Zhang, Jiangtao Hu, Feng Xue, Yongxin Li, Chengjun Sun

    A gas chromatography–electron impact–tandem mass spectrometric method was established for the simultaneous determination of seven adulterants, including fenfluramine (FEN), norpseudoephedrine (NPE), pseudoephedrine (PSE), ephedrine (EPH), amfepramone (AMF), sibutramine (SIB) and strychnine (STR) in slimming functional foods. The target chemicals were extracted with 2% formic acid solution and then cleaned-up with solid-phase extraction using a strong cation exchange cartridge from tablet, liquid, mixed plant powder and capsule formulations. Chromatographic separation was accomplished on a VF-5MS column within 23 min. Leucomalachite green was employed as an internal standard. The recoveries of seven target chemicals in two formulations ranged from 80.1 to 106%. Limits of detection of the method were from 7.5 to 375 µg/kg with relative standard deviations of 1.6 to 13.9%. The linearity of the method ranged from 90 to 1500 ng/mL for NPE, 150 to 1500 ng/mL for STR, 10 to 500 ng/mL for AMF, 5.0 to 500 ng/mL for PSE and EPH and 3.0 to 500 ng/mL for FEN and SIB. This method was applied to the determination of six brands of slimming functional foods. SIB was detected in five of the samples with the contents in the range of 10.3 – 8.55 × 105 μg/kg.