Tainsong Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tainsong Chen has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Chia-Hung Lin
Department of Electrical Engineering, Kao Yuan University, Kaohsiung City 82151, Taiwan
3 shared publicationsYi-Chun Du
Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan City 71005, Taiwan
3 shared publicationsGuan-Chun Chen
Department of Biomedical Engineering, National Cheng Kung University, Tainan City 70101, Taiwan
2 shared publications- Guan-Chun Chen
National Synchrotron Radiation Research Center, Hsinchu Science Park, Hsinchu, Taiwan
2 shared publications Jian-Xing Wu
Department of Biomedical Engineering, National Cheng Kung University, Tainan City 70101, Taiwan
2 shared publications- Pei-Jarn Chen
Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan City 71005, Taiwan
2 shared publications
Latest Publications
- 6 May 2016
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (2) , 257-270
Bilateral photoplethysmography for arterial steal detection in arteriovenous fistula using a fractional-order decision-making quantizer
As inflow and outflow stenoses worsen, both flow resistance and pressure increase in the stenotic vascular access. During dialysis, when blood flow decreases, it may retrograde from the peripheral artery through the palmar arch to the arterial anastomosis site. Arterial steal syndrome (ASS) causes distal hypoperfusion, resulting in hand ischemia or extremity pain and edema. Hence, this study proposes the bilateral photoplethysmography (PPG) for ASS detection in arteriovenous fistulas. The decision-making quantizer utilizes the fractional-order feature extraction method and a non-cooperative game (NCG) framework to evaluate the ASS risk level. Bilateral asynchronous PPG signals have significant differences in the rise time and amplitude in relation to the degree of stenosis. The fractional-order self-synchronization error formulation is a feature extraction method used to quantify bilateral differences in blood flow changes between the dexter and sinister PPG signals. The NCG model as a method of decision-making is then employed to evaluate the ASS risk level. Using an acoustic Doppler measurement, the resistive (Res) index is also used to evaluate the vascular access stenosis at the arterial anastomosis site. In contrast with alternative methods including the high-sensitivity C-reactive protein level or Res index, our experimental results indicate that the proposed decision-making quantizer is more efficient in preventing ASS during hemodialysis treatment.
- 6 May 2016
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (2) , 257-270
Bilateral photoplethysmography for arterial steal detection in arteriovenous fistula using a fractional-order decision-making quantizer
As inflow and outflow stenoses worsen, both flow resistance and pressure increase in the stenotic vascular access. During dialysis, when blood flow decreases, it may retrograde from the peripheral artery through the palmar arch to the arterial anastomosis site. Arterial steal syndrome (ASS) causes distal hypoperfusion, resulting in hand ischemia or extremity pain and edema. Hence, this study proposes the bilateral photoplethysmography (PPG) for ASS detection in arteriovenous fistulas. The decision-making quantizer utilizes the fractional-order feature extraction method and a non-cooperative game (NCG) framework to evaluate the ASS risk level. Bilateral asynchronous PPG signals have significant differences in the rise time and amplitude in relation to the degree of stenosis. The fractional-order self-synchronization error formulation is a feature extraction method used to quantify bilateral differences in blood flow changes between the dexter and sinister PPG signals. The NCG model as a method of decision-making is then employed to evaluate the ASS risk level. Using an acoustic Doppler measurement, the resistive (Res) index is also used to evaluate the vascular access stenosis at the arterial anastomosis site. In contrast with alternative methods including the high-sensitivity C-reactive protein level or Res index, our experimental results indicate that the proposed decision-making quantizer is more efficient in preventing ASS during hemodialysis treatment.
- Open Access
Ultrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom
The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastography, the eSNR and depth of ultrasound penetration must be increased using chirp-coded excitation. Moreover, the low axial resolution of ultrasound images generated by a chirp-coded pulse must be increased using an appropriate compression filter. The main aim of this study is to develop an ultrasound elasticity imaging system with chirp-coded excitation using a Tukey window for assessing the biomechanical properties of soft tissues. In this study, we propose an ultrasound elasticity imaging system equipped with a 7.5-MHz single-element transducer and polymethylpentene compression plate to measure strains in soft tissues. Soft tissue strains were analyzed using cross correlation (CC) and absolution difference (AD) algorithms. The optimal parameters of CC and AD algorithms used for the ultrasound elasticity imaging system with chirp-coded excitation were determined by measuring the elastographic signal-to-noise ratio (SNRe) of a homogeneous phantom. Moreover, chirp-coded excitation and short pulse excitation were used to measure the elasticity properties of the phantom. The elastographic qualities of the tissue-mimicking phantom were assessed in terms of Young’s modulus and elastographic contrast-to-noise ratio (CNRe). The results show that the developed ultrasound elasticity imaging system with chirp-coded excitation modulated by a Tukey window can acquire accurate, high-quality elastography images.
Open AccessUltrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom
The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastography, the eSNR and depth of ultrasound penetration must be increased using chirp-coded excitation. Moreover, the low axial resolution of ultrasound images generated by a chirp-coded pulse must be increased using an appropriate compression filter. The main aim of this study is to develop an ultrasound elasticity imaging system with chirp-coded excitation using a Tukey window for assessing the biomechanical properties of soft tissues. In this study, we propose an ultrasound elasticity imaging system equipped with a 7.5-MHz single-element transducer and polymethylpentene compression plate to measure strains in soft tissues. Soft tissue strains were analyzed using cross correlation (CC) and absolution difference (AD) algorithms. The optimal parameters of CC and AD algorithms used for the ultrasound elasticity imaging system with chirp-coded excitation were determined by measuring the elastographic signal-to-noise ratio (SNRe) of a homogeneous phantom. Moreover, chirp-coded excitation and short pulse excitation were used to measure the elasticity properties of the phantom. The elastographic qualities of the tissue-mimicking phantom were assessed in terms of Young’s modulus and elastographic contrast-to-noise ratio (CNRe). The results show that the developed ultrasound elasticity imaging system with chirp-coded excitation modulated by a Tukey window can acquire accurate, high-quality elastography images.
- Open Access
- 1 January 2015
- Published by Wiley in The Scientific World Journal
- Vol. 2015 (1) , 697569
Virtual‐Reality Simulator System for Double Interventional Cardiac Catheterization Using Fractional‐Order Vascular Access Tracker and Haptic Force Producer
This study proposes virtual‐reality (VR) simulator system for double interventional cardiac catheterization (ICC) using fractional‐order vascular access tracker and haptic force producer. An endoscope or a catheter for diagnosis and surgery of cardiovascular disease has been commonly used in minimally invasive surgery. It needs specific skills and experiences for young surgeons or postgraduate year (PGY) students to operate a Berman catheter and a pigtail catheter in the inside of the human body and requires avoiding damaging vessels. To improve the training in inserting catheters, a double‐catheter mechanism is designed for the ICC procedures. A fractional‐order vascular access tracker is used to trace the senior surgeons’ consoled trajectories and transmit the frictional feedback and visual feedback during the insertion of catheters. Based on the clinical feeling through the aortic arch, vein into the ventricle, or tortuous blood vessels, haptic force producer is used to mock the elasticity of the vessel wall using voice coil motors (VCMs). The VR establishment with surgeons’ consoled vessel trajectories and hand feeling is achieved, and the experimental results show the effectiveness for the double ICC procedures.
- 1 January 2015
- Published by Wiley in The Scientific World Journal
- Vol. 2015 (1) , 697569
Open AccessVirtual‐Reality Simulator System for Double Interventional Cardiac Catheterization Using Fractional‐Order Vascular Access Tracker and Haptic Force Producer
This study proposes virtual‐reality (VR) simulator system for double interventional cardiac catheterization (ICC) using fractional‐order vascular access tracker and haptic force producer. An endoscope or a catheter for diagnosis and surgery of cardiovascular disease has been commonly used in minimally invasive surgery. It needs specific skills and experiences for young surgeons or postgraduate year (PGY) students to operate a Berman catheter and a pigtail catheter in the inside of the human body and requires avoiding damaging vessels. To improve the training in inserting catheters, a double‐catheter mechanism is designed for the ICC procedures. A fractional‐order vascular access tracker is used to trace the senior surgeons’ consoled trajectories and transmit the frictional feedback and visual feedback during the insertion of catheters. Based on the clinical feeling through the aortic arch, vein into the ventricle, or tortuous blood vessels, haptic force producer is used to mock the elasticity of the vessel wall using voice coil motors (VCMs). The VR establishment with surgeons’ consoled vessel trajectories and hand feeling is achieved, and the experimental results show the effectiveness for the double ICC procedures.
- Open Access
- 30 April 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-13
Multiple-Site Hemodynamic Analysis of Doppler Ultrasound with an Adaptive Color Relation Classifier for Arteriovenous Access Occlusion Evaluation
This study proposes multiple-site hemodynamic analysis of Doppler ultrasound with an adaptive color relation classifier for arteriovenous access occlusion evaluation in routine examinations. The hemodynamic analysis is used to express the properties of blood flow through a vital access or a tube, using dimensionless numbers. An acoustic measurement is carried out to detect the peak-systolic and peak-diastolic velocities of blood flow from the arterial anastomosis sites (A) to the venous anastomosis sites (V). The ratio of the supracritical Reynolds () number and the resistive (Res) index quantitates the degrees of stenosis (DOS) at multiple measurement sites. Then, an adaptive color relation classifier is designed as a nonlinear estimate model to survey the occlusion level in monthly examinations. For 30 long-term follow-up patients, the experimental results show the proposed screening model efficiently evaluates access occlusion.- 30 April 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-13
Open AccessMultiple-Site Hemodynamic Analysis of Doppler Ultrasound with an Adaptive Color Relation Classifier for Arteriovenous Access Occlusion Evaluation
This study proposes multiple-site hemodynamic analysis of Doppler ultrasound with an adaptive color relation classifier for arteriovenous access occlusion evaluation in routine examinations. The hemodynamic analysis is used to express the properties of blood flow through a vital access or a tube, using dimensionless numbers. An acoustic measurement is carried out to detect the peak-systolic and peak-diastolic velocities of blood flow from the arterial anastomosis sites (A) to the venous anastomosis sites (V). The ratio of the supracritical Reynolds () number and the resistive (Res) index quantitates the degrees of stenosis (DOS) at multiple measurement sites. Then, an adaptive color relation classifier is designed as a nonlinear estimate model to survey the occlusion level in monthly examinations. For 30 long-term follow-up patients, the experimental results show the proposed screening model efficiently evaluates access occlusion. - Open Access
- 9 December 2013
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (S1) , S4
Clinical Verification of A Clinical Decision Support System for Ventilator Weaning
Background: Weaning is typically regarded as a process of discontinuing mechanical ventilation in the daily practice of an intensive care unit (ICU). Among the ICU patients, 39%-40% need mechanical ventilator for sustaining their lives. The predictive rate of successful weaning achieved only 35-60% for decisions made by physicians. Clinical decision support systems (CDSSs) are promising in enhancing diagnostic performance and improve healthcare quality in clinical setting. To our knowledge, a prospective study has never been conducted to verify the effectiveness of the CDSS in ventilator weaning before. In this study, the CDSS capable of predicting weaning outcome and reducing duration of ventilator support for patients has been verified. Methods: A total of 380 patients admitted to the respiratory care center of the hospital were randomly assigned to either control or study group. In the control group, patients were weaned with traditional weaning method, while in the study group, patients were weaned with CDSS monitored by physicians. After excluding the patients who transferred to other hospitals, refused further treatments, or expired the admission period, data of 168 and 144 patients in the study and control groups, respectively, were used for analysis. Results: The results show that a sensitivity of 87.7% has been achieved, which is significantly higher (pp<0.001) shorter than the control group (43.69 ± 14.89), with a decrease of 5.2 days in average, resulting in a saving of healthcare cost of NT$45,000 (US$1,500) per patient in the current Taiwanese National Health Insurance setting. Conclusions: The CDSS is demonstrated to be effective in identifying the earliest time of ventilator weaning for patients to resume and sustain spontaneous breathing, thereby avoiding unnecessary prolonged ventilator use and decreasing healthcare cost.
- 9 December 2013
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (S1) , S4
Open AccessClinical Verification of A Clinical Decision Support System for Ventilator Weaning
Background: Weaning is typically regarded as a process of discontinuing mechanical ventilation in the daily practice of an intensive care unit (ICU). Among the ICU patients, 39%-40% need mechanical ventilator for sustaining their lives. The predictive rate of successful weaning achieved only 35-60% for decisions made by physicians. Clinical decision support systems (CDSSs) are promising in enhancing diagnostic performance and improve healthcare quality in clinical setting. To our knowledge, a prospective study has never been conducted to verify the effectiveness of the CDSS in ventilator weaning before. In this study, the CDSS capable of predicting weaning outcome and reducing duration of ventilator support for patients has been verified. Methods: A total of 380 patients admitted to the respiratory care center of the hospital were randomly assigned to either control or study group. In the control group, patients were weaned with traditional weaning method, while in the study group, patients were weaned with CDSS monitored by physicians. After excluding the patients who transferred to other hospitals, refused further treatments, or expired the admission period, data of 168 and 144 patients in the study and control groups, respectively, were used for analysis. Results: The results show that a sensitivity of 87.7% has been achieved, which is significantly higher (pp<0.001) shorter than the control group (43.69 ± 14.89), with a decrease of 5.2 days in average, resulting in a saving of healthcare cost of NT$45,000 (US$1,500) per patient in the current Taiwanese National Health Insurance setting. Conclusions: The CDSS is demonstrated to be effective in identifying the earliest time of ventilator weaning for patients to resume and sustain spontaneous breathing, thereby avoiding unnecessary prolonged ventilator use and decreasing healthcare cost.
- 5 May 2013
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 51 (9) , 1011-1019
Phonographic signal with a fractional-order chaotic system: a novel and simple algorithm for analyzing residual arteriovenous access stenosis
To detect the early developmental stages of arteriovenous access (AVA) stenosis in hemodialysis patients, this study explored a stenosis detector based on the Burg method and the fractional-order chaos system (FOCS). The bruit developed by the blood flowing through AVA can be a viable noninvasive strategy for monitoring AVA functions. We used the Burg method of the autoregressive model to estimate the frequency spectra of phonographic signals recorded by an electronic stethoscope in patients’ AVAs and to identify the spectral peaks in the region of 25–800 Hz. The frequency spectra differed significantly between normal and stenosis statuses in AVA. We found that the frequency and amplitude in power spectra analysis varied in accordance with the severity of AVA stenosis. However, the correlation of these parameters for classifying the degree of stenosis is limited when only using the Burg method. Therefore, we used an FOCS to monitor the differing frequency spectra between the normal condition and AVA stenosis. The variances of these two conditions were dynamic errors that were the coupling variables that tracked the responses between the master system and the slave system. A total of 42 patients who had received percutaneous transluminal angioplasty (PTA) for their failing AVAs was recruited for this study. In this study, the dynamic error, Index Ψ, was used to calculate the frequency spectrum redistribution in patients undergoing PTA. In addition, ΔImp was the index used to evaluate improvements in the luminal diameter between pre- and post-PTA. Therefore, we used linear regression to model the relationship between ΔImp and Index Ψ. The findings indicate that the proposed method has enhanced efficiency, especially in the venous anastomosis (V-site). The FOCS is a novel and simple algorithm for analyzing the residual AVA stenosis of PTA treatment.
- 5 May 2013
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 51 (9) , 1011-1019
Phonographic signal with a fractional-order chaotic system: a novel and simple algorithm for analyzing residual arteriovenous access stenosis
To detect the early developmental stages of arteriovenous access (AVA) stenosis in hemodialysis patients, this study explored a stenosis detector based on the Burg method and the fractional-order chaos system (FOCS). The bruit developed by the blood flowing through AVA can be a viable noninvasive strategy for monitoring AVA functions. We used the Burg method of the autoregressive model to estimate the frequency spectra of phonographic signals recorded by an electronic stethoscope in patients’ AVAs and to identify the spectral peaks in the region of 25–800 Hz. The frequency spectra differed significantly between normal and stenosis statuses in AVA. We found that the frequency and amplitude in power spectra analysis varied in accordance with the severity of AVA stenosis. However, the correlation of these parameters for classifying the degree of stenosis is limited when only using the Burg method. Therefore, we used an FOCS to monitor the differing frequency spectra between the normal condition and AVA stenosis. The variances of these two conditions were dynamic errors that were the coupling variables that tracked the responses between the master system and the slave system. A total of 42 patients who had received percutaneous transluminal angioplasty (PTA) for their failing AVAs was recruited for this study. In this study, the dynamic error, Index Ψ, was used to calculate the frequency spectrum redistribution in patients undergoing PTA. In addition, ΔImp was the index used to evaluate improvements in the luminal diameter between pre- and post-PTA. Therefore, we used linear regression to model the relationship between ΔImp and Index Ψ. The findings indicate that the proposed method has enhanced efficiency, especially in the venous anastomosis (V-site). The FOCS is a novel and simple algorithm for analyzing the residual AVA stenosis of PTA treatment.
- 1 January 2013
- Published by Springer Nature
- No. 02,p. 1499-1502
Development of a High-Frequency Ultrasound System for High Speed Image Scanning
- 1 January 2013
- Published by Springer Nature
- No. 02,p. 1499-1502
Development of a High-Frequency Ultrasound System for High Speed Image Scanning
- 3 June 2010
- Published by Springer Nature in Journal of Medical Systems
- Vol. 35 (5) , 877-883
Development of a Telecare System Based on ZigBee Mesh Network for Monitoring Blood Pressure of Patients with Hemodialysis in Health Care Centers
In Taiwan, the number of the patients needing dialysis increases rapidly in recent years. Because there is risk in every hemodialysis session, monitoring physiological status, such as blood pressure measurement every 30 min to 1 h is needed during about 4 h hemodialysis process. Therefore, an assisted measurement on blood pressure is needful in dialysis care centers. Telecare system (TCS) is regarded as one of important technique in the medical care. In this study, we utilized ZigBee wireless technique to establish a mesh network for monitoring blood pressure automatically and data storage in medical record system for display and further analysis. Moreover, while the blood pressure exceeds the normal range, the system could send a warning signal to remind, or inform the relatives and clinicians in health care center through the personal handy-phone system (PHS) immediately. The proposed system provides an assisted device for monitoring patients’ blood pressure during hemodialysis process and saving medical manpower.
- 3 June 2010
- Published by Springer Nature in Journal of Medical Systems
- Vol. 35 (5) , 877-883
Development of a Telecare System Based on ZigBee Mesh Network for Monitoring Blood Pressure of Patients with Hemodialysis in Health Care Centers
In Taiwan, the number of the patients needing dialysis increases rapidly in recent years. Because there is risk in every hemodialysis session, monitoring physiological status, such as blood pressure measurement every 30 min to 1 h is needed during about 4 h hemodialysis process. Therefore, an assisted measurement on blood pressure is needful in dialysis care centers. Telecare system (TCS) is regarded as one of important technique in the medical care. In this study, we utilized ZigBee wireless technique to establish a mesh network for monitoring blood pressure automatically and data storage in medical record system for display and further analysis. Moreover, while the blood pressure exceeds the normal range, the system could send a warning signal to remind, or inform the relatives and clinicians in health care center through the personal handy-phone system (PHS) immediately. The proposed system provides an assisted device for monitoring patients’ blood pressure during hemodialysis process and saving medical manpower.
- Open Access
- 1 September 2008
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 8 (12) , 5
Quantitative assessment of divergence eye movements
Purpose: This study sought to quantify divergence eye movements and differences between divergence and convergence to smoothly moving ramp, step, and disappearing step stimuli. Methods: Eight visually normal, adult subjects participated in three experiments investigating the dynamics of responses using an infrared limbal eye tracker. Results: There were four primary findings: (1) a smooth tracking behavior was observed for slow ramps while the fast ramps elicited smooth tracking combined with a high-velocity, step-like behavior; (2) the high-velocity components observed in the faster ramps had a similar main sequence as divergence steps; (3) divergence dynamics to disappearing steps starting at the subject's near dissociated phoria level were similar to corresponding step responses; and (4) the high-velocity components from divergence ramps were dependent on initial vergence position, whereas the high-velocity components from convergence ramps were not. Conclusion: The results suggest a preprogrammed component is present in divergence similar to convergence; however, unlike convergence, the high-velocity components from divergence ramp responses are dependent on initial vergence position.
- 1 September 2008
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 8 (12) , 5
Open AccessQuantitative assessment of divergence eye movements
Purpose: This study sought to quantify divergence eye movements and differences between divergence and convergence to smoothly moving ramp, step, and disappearing step stimuli. Methods: Eight visually normal, adult subjects participated in three experiments investigating the dynamics of responses using an infrared limbal eye tracker. Results: There were four primary findings: (1) a smooth tracking behavior was observed for slow ramps while the fast ramps elicited smooth tracking combined with a high-velocity, step-like behavior; (2) the high-velocity components observed in the faster ramps had a similar main sequence as divergence steps; (3) divergence dynamics to disappearing steps starting at the subject's near dissociated phoria level were similar to corresponding step responses; and (4) the high-velocity components from divergence ramps were dependent on initial vergence position, whereas the high-velocity components from convergence ramps were not. Conclusion: The results suggest a preprogrammed component is present in divergence similar to convergence; however, unlike convergence, the high-velocity components from divergence ramp responses are dependent on initial vergence position.