Kohji Ohbayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kohji Ohbayashi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Donghak Choi
Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan
2 shared publicationsHideaki Hiro-Oka
Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan
2 shared publicationsHiroyuki Furukawa
Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan
2 shared publicationsKimiya Shimizu
Department of Ophthalmology, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0374, Japan
2 shared publicationsMotoi Nakanishi
Department of Ophthalmology, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0374, Japan
2 shared publicationsReiko Yoshimura
Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan
2 shared publications
Latest Publications
- Open Access
- 1 December 2013
- Published by Springer Nature in BMC Urology
- Vol. 13 (1) , 65
The impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma
Optical coherence tomography (OCT) has become a promising diagnostic tool in many medical fields. In particular, noninvasive real-time optical biopsy of internal organs is one of the most attractive applications of OCT, enabling in situ diagnosis of carcinoma at an early stage. We used an ultra-high speed OCT system for real-time three-dimensional (3D) imaging of three excised specimens of advanced urothelial carcinoma (UC) and investigated the association of the images with results from histopathological examination.
- 1 December 2013
- Published by Springer Nature in BMC Urology
- Vol. 13 (1) , 65
Open AccessThe impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma
Optical coherence tomography (OCT) has become a promising diagnostic tool in many medical fields. In particular, noninvasive real-time optical biopsy of internal organs is one of the most attractive applications of OCT, enabling in situ diagnosis of carcinoma at an early stage. We used an ultra-high speed OCT system for real-time three-dimensional (3D) imaging of three excised specimens of advanced urothelial carcinoma (UC) and investigated the association of the images with results from histopathological examination.
- Open Access
- 23 November 2010
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 1 (5) , 1491-1501
Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging
We describe a high-speed long-depth range optical frequency domain imaging (OFDI) system employing a long-coherence length tunable source and demonstrate dynamic full-range imaging of the anterior segment of the eye including from the cornea surface to the posterior capsule of the crystalline lens with a depth range of 12 mm without removing complex conjugate image ambiguity. The tunable source spanned from 1260 to 1360 nm with an average output power of 15.8 mW. The fast A-scan rate of 20,000 per second provided dynamic OFDI and dependence of the whole anterior segment change on time following abrupt relaxation from the accommodated to the relaxed status, which was measured for a healthy eye and that with an intraocular lens.
- 23 November 2010
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 1 (5) , 1491-1501
Open AccessFull-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging
We describe a high-speed long-depth range optical frequency domain imaging (OFDI) system employing a long-coherence length tunable source and demonstrate dynamic full-range imaging of the anterior segment of the eye including from the cornea surface to the posterior capsule of the crystalline lens with a depth range of 12 mm without removing complex conjugate image ambiguity. The tunable source spanned from 1260 to 1360 nm with an average output power of 15.8 mW. The fast A-scan rate of 20,000 per second provided dynamic OFDI and dependence of the whole anterior segment change on time following abrupt relaxation from the accommodated to the relaxed status, which was measured for a healthy eye and that with an intraocular lens.
- 9 June 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (12) , 1318-1320
Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s
We describe high-speed Fourier domain optical coherence tomography (OCT) using optical demultiplexers (ODs) for spectral dispersion. The OD enables separation of a narrow spectral band of from a broadband incident light at 256 different frequencies in intervals centered at . OCT imaging of 60,000,000 axial scans per second was achieved through parallel signal acquisition using 256 balanced photoreceivers to simultaneously detect all the output signals from the ODs in a Fourier domain OCT system. OCT imaging at a frame rate, 1100 A-lines per frame, depth range, and resolution was demonstrated using a resonant scanner for lateral scanning.- 9 June 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (12) , 1318-1320
Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s
We describe high-speed Fourier domain optical coherence tomography (OCT) using optical demultiplexers (ODs) for spectral dispersion. The OD enables separation of a narrow spectral band of from a broadband incident light at 256 different frequencies in intervals centered at . OCT imaging of 60,000,000 axial scans per second was achieved through parallel signal acquisition using 256 balanced photoreceivers to simultaneously detect all the output signals from the ODs in a Fourier domain OCT system. OCT imaging at a frame rate, 1100 A-lines per frame, depth range, and resolution was demonstrated using a resonant scanner for lateral scanning.