KOKohji Ohbayashi

Kohji Ohbayashi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kohji Ohbayashi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Donghak Choi

    Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan

    2 shared publications
  • Hideaki Hiro-Oka

    Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan

    2 shared publications
  • Hiroyuki Furukawa

    Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan

    2 shared publications
  • Kimiya Shimizu

    Department of Ophthalmology, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0374, Japan

    2 shared publications
  • Motoi Nakanishi

    Department of Ophthalmology, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0374, Japan

    2 shared publications
  • Reiko Yoshimura

    Center for Natural Science, Kitasato University, Kitasato 1-15-1, Minamiku, Sagamihara, Kanagawa, 232-0373, Japan

    2 shared publications

Latest Publications

  • Open Access

    The impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma

    by Masaomi Ikeda, Kazumasa Matsumoto, Donghak Choi, Morihiro Nishi, Tetsuo Fujita, Kohji Ohbayashi, Kimiya Shimizu, Masatsugu Iwamura

    Optical coherence tomography (OCT) has become a promising diagnostic tool in many medical fields. In particular, noninvasive real-time optical biopsy of internal organs is one of the most attractive applications of OCT, enabling in situ diagnosis of carcinoma at an early stage. We used an ultra-high speed OCT system for real-time three-dimensional (3D) imaging of three excised specimens of advanced urothelial carcinoma (UC) and investigated the association of the images with results from histopathological examination.


  • Open Access

    Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging

    by Hiroyuki Furukawa, Hideaki Hiro-Oka, Nobuyuki Satoh, Reiko Yoshimura, Donghak Choi, Motoi Nakanishi, Akihito Igarashi, Hitoshi Ishikawa, Kohji Ohbayashi, Kimiya Shimizu

    We describe a high-speed long-depth range optical frequency domain imaging (OFDI) system employing a long-coherence length tunable source and demonstrate dynamic full-range imaging of the anterior segment of the eye including from the cornea surface to the posterior capsule of the crystalline lens with a depth range of 12 mm without removing complex conjugate image ambiguity. The tunable source spanned from 1260 to 1360 nm with an average output power of 15.8 mW. The fast A-scan rate of 20,000 per second provided dynamic OFDI and dependence of the whole anterior segment change on time following abrupt relaxation from the accommodated to the relaxed status, which was measured for a healthy eye and that with an intraocular lens.


  • Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s

    by Donghak Choi, Hideaki Hiro-Oka, Hiroyuki Furukawa, Reiko Yoshimura, Motoi Nakanishi, Kimiya Shimizu, Kohji Ohbayashi

    We describe high-speed Fourier domain optical coherence tomography (OCT) using optical demultiplexers (ODs) for spectral dispersion. The OD enables separation of a narrow spectral band of 14GHz (0.11nm) from a broadband incident light at 256 different frequencies in 25.0GHz intervals centered at 192.2THz (1559.8nm). OCT imaging of 60,000,000 axial scans per second was achieved through parallel signal acquisition using 256 balanced photoreceivers to simultaneously detect all the output signals from the ODs in a Fourier domain OCT system. OCT imaging at a 16kHz frame rate, 1100 A-lines per frame, 3mm depth range, and 23μm resolution was demonstrated using a resonant scanner for lateral scanning.