KSKamakshi Prashadini Swain

Kamakshi Prashadini Swain

*This is an algorithmically generated author record based on publicly available information.

Kamakshi Prashadini Swain has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Network-Level Vulnerability Assessment of Synchrophasor Measurement Devices

    by Kamakshi P. Swain, Ankush Sharma, Amey Karkare, Saikat Chakrabarti, Elena Gryazina, Vladimir Terzija

    Vulnerability assessment forms the foundation for remediation activities that an organization develops as a part of risk assessment and mitigation. This paper presents a synchrophasor measurement device-specific cyber security vulnerability assessment at network level. A synchrophasor network is essential for wide-area measurement system (WAMS) that assembles time-synchronized data from multiple power network components and facilitates the processing and transferring of these data. Attackers can leverage their knowledge of firmware and protocols to disrupt or critically damage the functioning of the power system in a stealthy manner. Nevertheless, the exploitation can be curbed or controlled if the operator is aware of the vulnerabilities associated with the field devices. The authors detail their analysis on the following aspects: (a) classification of attacks in synchrophasor network, (b) Type of resources and reconnaissance sufficient to launch an attack on field devices, (c) identification, demonstration, and exploitation of synchrophasor device vulnerabilities. The work showcases exploitable vulnerabilities, to understand the breath and scope of a synchrophasor measurement device’s exposure to a possible cyber attack. The reverse-engineered attack focuses on capturing essential features of packets and consuming the bandwidth during the three-way handshake among legitimate entities. The latency in packet transmission is gradually increased, which results in retransmission; thus, the legitimate connection gets terminated. Thus, the paper provides situational awareness at the device level and credible information regarding loopholes and weak links in field devices.


  • Identification and mitigation of congestion in distribution system utilizing proximity index‐based demand response

    by Kamakshi P. Swain, Mala De

    With the integration of distributed energy resources and transition towards smart grid, the existing power system has undergone a paradigm change. However, increasing flexibilities in demand and penetration of local generation to minimize the mismatch between generation and supply has changed the operational characteristics of distribution system. Integration of local generation assists bypassing congestion when placed in the proper location, but excessive generation or incorrectly placed generators can lead to congestion in the distribution networks. This paper proposes a demand response‐based technique to mitigate congestion in distribution networks using power transfer distribution factors (PTDFs) and a new network impedance‐based index known as proximity index. Power transfer distribution factor is used in case of meshed distribution system and proximity index is used in case of radial system where PTDF‐based congestion management fails. By utilizing the network topology, the optimal buses are identified; participation of these buses in DR‐based congestion management will be most effective in relieving congestion. The loads of these lines will be partially or fully shifted to reduce/get rid of congestion of the network. The proposed method is validated for both meshed type as well as radial distribution networks.


  • DSM for all‐day voltage profile improvement in a microgrid

    by Kamakshi Prashadini Swain, Mala De

    The role of demand side management (DSM) has changed the scenario of control and management in a microgrid. DSM works on real time without utilising any additional equipment in the network. The study proposes an all‐day voltage control methodology using DSM. The contribution of this study is threefold. Firstly, a novel method for the day ahead voltage profile improvement is proposed by shifting flexible loads using demand and generation forecast information. Secondly, the proposed method uses only two parameters, the impedance of the network and amount of power injected to the flexible loads, in order to influence the voltage level and to improve overall voltage profile of the system. Thirdly, factor matrix is introduced; it decides which flexible loads to be shifted to regulate voltage within tolerance limits. In order to verify the effectiveness of the proposed voltage control method, it is tested on an low voltage (LV) distribution system considered as a microgrid. The result indicates that when the flexible loads are shifted with proper margin, the voltage of the system is contained within a limit and results in better load distribution throughout the day.


  • Loss allocation method independent of dynamic load variation

    by Kamakshi Prashadini Swain, Mala De

    The paper proposes a technique to allocate the power flow and loss in a deregulated power system. The proposed technique is developed based on the concept of relative electrical distance. An algorithm has been developed to identify the contribution of generator on the line flow and the line loss. The proposed method works with the impedance of the network, which is a fixed parameter unless there is an alterations in the network topology. This feature eliminates the requirement of repeated load flow analysis, which is used for determining generator contribution on line flow and loss by most of the existing methods. The proposed allocation method will be independent of continuous load changes in the network. Hence it can be used for determining the contribution of a generator which will be valid for longer time period unlike other commonly used power flow based methods. This method can be used to decide the cost associated with loss to the market players for a time period until new facilities are built up. Proposed technique is implemented on IEEE 30 bus system to compute the contribution of generator bus on the line loss using RED concept.