Chunsheng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chunsheng Wang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Kunzheng Wang
Department of Bone and Joint Surgery, Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
4 shared publications - Pei Yang
Department of Bone and Joint Surgery, Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
4 shared publications - Run Tian
Department of Bone and Joint Surgery, Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
3 shared publications - Junyan Li
Department of Bone and Joint Surgery, Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
2 shared publications - Sen Luo
Department of Bone and Joint Surgery, Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
2 shared publications - Xu Gao
Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
2 shared publications
Latest Publications
- 22 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 865
Robotic-referenced automated measurement of acetabular cup orientation on postoperative CT: development and internal validation
Accurate measurement of acetabular cup orientation after total hip arthroplasty is essential, but postoperative CT relies on subjective, error-prone manual measurement. Robot-assisted surgery provides intraoperative cup-orientation measurements but is costly and not widely available. We aimed to develop and evaluate a deep-learning model measuring cup orientation on postoperative CT, using robotic navigation values as reference standard. This secondary analysis of a randomized trial (ChiCTR2200060115) analyzed 94 hips with robotic intraoperative angle measurements and postoperative CT (May 2023 to May 2024). A VGG16-based U-Net segmented key anatomical structures into three-dimensional point clouds. Three measurement pathways were compared: manual annotation, machine learning, and deep learning. The optimal model was integrated into a graphical user interface. Ninety-four hips (mean age, 57.0 years ± 9.5 [standard deviation]; 62 men) were evaluated using 27,821 CT images. The best model (PointNet++) achieved mean absolute errors of 4.48° (anteversion) and 3.89° (inclination), compared with 4.08°/ 5.52° for machine learning and 8.91°/ 8.70° for manual measurement, significantly outperforming manual measurement (both p < 0.05). Exploratory full-cohort Lewinnek classification was correct in 81/94 hips versus 57/94 with manual measurement; in internal validation, 71% and 81% of predictions were within 5° of the robotic reference. A deep-learning model developed using robotic navigation values showed promising internal-validation performance for automated cup-orientation measurement on postoperative CT; independent external validation is required before broader clinical application. Trial registration ChiCTR2200060115, 19 May 2022.
- 22 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 865
Robotic-referenced automated measurement of acetabular cup orientation on postoperative CT: development and internal validation
Accurate measurement of acetabular cup orientation after total hip arthroplasty is essential, but postoperative CT relies on subjective, error-prone manual measurement. Robot-assisted surgery provides intraoperative cup-orientation measurements but is costly and not widely available. We aimed to develop and evaluate a deep-learning model measuring cup orientation on postoperative CT, using robotic navigation values as reference standard. This secondary analysis of a randomized trial (ChiCTR2200060115) analyzed 94 hips with robotic intraoperative angle measurements and postoperative CT (May 2023 to May 2024). A VGG16-based U-Net segmented key anatomical structures into three-dimensional point clouds. Three measurement pathways were compared: manual annotation, machine learning, and deep learning. The optimal model was integrated into a graphical user interface. Ninety-four hips (mean age, 57.0 years ± 9.5 [standard deviation]; 62 men) were evaluated using 27,821 CT images. The best model (PointNet++) achieved mean absolute errors of 4.48° (anteversion) and 3.89° (inclination), compared with 4.08°/ 5.52° for machine learning and 8.91°/ 8.70° for manual measurement, significantly outperforming manual measurement (both p < 0.05). Exploratory full-cohort Lewinnek classification was correct in 81/94 hips versus 57/94 with manual measurement; in internal validation, 71% and 81% of predictions were within 5° of the robotic reference. A deep-learning model developed using robotic navigation values showed promising internal-validation performance for automated cup-orientation measurement on postoperative CT; independent external validation is required before broader clinical application. Trial registration ChiCTR2200060115, 19 May 2022.
- 5 June 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 237-248
Computed tomography radiomics in predicting patient satisfaction after robotic-assisted total knee arthroplasty
Purpose After robotic-assisted total knee arthroplasty (RA-TKA) surgery, some patients still experience joint discomfort. We aimed to establish an effective machine learning model that integrates radiomic features extracted from computed tomography (CT) scans and relevant clinical information to predict patient satisfaction three months postoperatively following RA-TKA. Materials and methods After careful selection, data from 142 patients were randomly divided into a training set (n = 99) and a test set (n = 43), approximately in a 7:3 ratio. A total of 1329 radiomic features were extracted from the regions of interest delineated in CT scans. The features were standardized using normalization algorithms, and the least absolute shrinkage and selection operator regression model was employed to select radiomic features with ICC > 0.75 and P < 0.05, generating the Rad-score as feature markers. Univariate and multivariate logistic regression was then used to screen clinical information (age, body mass index, operation time, gender, surgical side, comorbidities, preoperative KSS score, preoperative range of motion (ROM), preoperative and postoperative HKA angle, preoperative and postoperative VAS score) as potential predictive factors. The satisfaction scale ≥ 20 indicates patient satisfaction. Finally, three prediction models were established, focusing on radiomic features, clinical features, and their fusion. Model performance was evaluated using Receiver Operating Characteristic curves and decision curve analysis. Results In the training set, the area under the curve (AUC) of the clinical model was 0.793 (95% CI 0.681–0.906), the radiomic model was 0.854 (95% CI 0.743–0.964), and the combined radiomic-clinical model was 0.899 (95% CI 0.804–0.995). In the test set, the AUC of the clinical model was 0.908 (95% CI 0.814–1.000), the radiomic model was 0.709 (95% CI 0.541–0.878), and the combined radiomic-clinical model was 0.928 (95% CI 0.842–1.000). The AUC of the radiomic-clinical model was significantly higher than the other two models. The decision curve analysis indicated its clinical application value. Conclusion We developed a radiomic-based nomogram model using CT imaging to predict the satisfaction of RA-TKA patients at 3 months postoperatively. This model integrated clinical and radiomic features and demonstrated good predictive performance and excellent clinical application potential.
- 5 June 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 237-248
Computed tomography radiomics in predicting patient satisfaction after robotic-assisted total knee arthroplasty
Purpose After robotic-assisted total knee arthroplasty (RA-TKA) surgery, some patients still experience joint discomfort. We aimed to establish an effective machine learning model that integrates radiomic features extracted from computed tomography (CT) scans and relevant clinical information to predict patient satisfaction three months postoperatively following RA-TKA. Materials and methods After careful selection, data from 142 patients were randomly divided into a training set (n = 99) and a test set (n = 43), approximately in a 7:3 ratio. A total of 1329 radiomic features were extracted from the regions of interest delineated in CT scans. The features were standardized using normalization algorithms, and the least absolute shrinkage and selection operator regression model was employed to select radiomic features with ICC > 0.75 and P < 0.05, generating the Rad-score as feature markers. Univariate and multivariate logistic regression was then used to screen clinical information (age, body mass index, operation time, gender, surgical side, comorbidities, preoperative KSS score, preoperative range of motion (ROM), preoperative and postoperative HKA angle, preoperative and postoperative VAS score) as potential predictive factors. The satisfaction scale ≥ 20 indicates patient satisfaction. Finally, three prediction models were established, focusing on radiomic features, clinical features, and their fusion. Model performance was evaluated using Receiver Operating Characteristic curves and decision curve analysis. Results In the training set, the area under the curve (AUC) of the clinical model was 0.793 (95% CI 0.681–0.906), the radiomic model was 0.854 (95% CI 0.743–0.964), and the combined radiomic-clinical model was 0.899 (95% CI 0.804–0.995). In the test set, the AUC of the clinical model was 0.908 (95% CI 0.814–1.000), the radiomic model was 0.709 (95% CI 0.541–0.878), and the combined radiomic-clinical model was 0.928 (95% CI 0.842–1.000). The AUC of the radiomic-clinical model was significantly higher than the other two models. The decision curve analysis indicated its clinical application value. Conclusion We developed a radiomic-based nomogram model using CT imaging to predict the satisfaction of RA-TKA patients at 3 months postoperatively. This model integrated clinical and radiomic features and demonstrated good predictive performance and excellent clinical application potential.
- 10 March 2022
- Published by Elsevier in European Journal of Pharmacology
- Vol. 921, 174871
Captopril alleviates glucocorticoid-induced osteonecrosis of the femoral head by mediating the ACE2/ Ang-(1-7)/Mas receptor cascade
- 10 March 2022
- Published by Elsevier in European Journal of Pharmacology
- Vol. 921, 174871
Captopril alleviates glucocorticoid-induced osteonecrosis of the femoral head by mediating the ACE2/ Ang-(1-7)/Mas receptor cascade
- Open Access
- 8 November 2013
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 14 (1) , 318
Development of a new pre-vascularized tissue-engineered construct using pre-differentiated rADSCs, arteriovenous vascular bundle and porous nano-hydroxyapatide-polyamide 66 scaffold
Background: Development of a pre-vascularized tissue-engineered construct with intrinsic vascular system for cell growth and tissue formation still faces many difficulties due to the complexity of the vascular network of natural bone tissue. The present study was to design and form a new vascularized tissue-engineered construct using pre-differentiated rADSCs, arteriovenous vascular bundle and porous nHA-PA 66 scaffold. Methods: rADSCs were pre-differentiated to endothelial cells (rADSCs-Endo) and then incorporated in nHA-PA 66 scaffolds in vitro. Subsequently, in vivo experiments were carried out according to the following groups: Group A (rADSCs-Endo/nHA-PA 66 scaffold with arteriovenous vascular bundle), Group B (rADSCs/nHA-PA 66 scaffold with arteriovenous vascular bundle); Group C (nHA-PA66 scaffold with arteriovenous vascular bundle), Group D (nHA-PA 66 scaffold only). The vessel density and vessel diameter were measured based on histological and immunohistochemical evaluation, furthermore, the VEGF-C, FGF-2 and BMP-2 protein expressions were also evaluated by western blot analysis. Results: The results of in vivo experiments showed that the vessel density and vessel diameter in group A were significantly higher than the other three groups. Between Group B and C, no statistical difference was observed at each time point. In accordance with the results, there were dramatically higher expressions of VEGF-C and FGF-2 protein in Group A than that of Group B, C and D at 2 or 4 weeks. Statistical differences were not observed in VEGF-C and FGF-2 expression between Group B and C. BMP-2 was not expressed in any group at each time point. Conclusions: Compared with muscular wrapping method, arteriovenous vascular bundle implantation could promote vascularization of the scaffold; and the angiogenesis of the scaffold was significantly accelerated when pre-differentiated rADSCs (endothelial differentiation) were added. These positive results implicate the combination of pre-differentiated rADSCs (endothelial differentiation) and arteriovenous vascular bundle may achieve rapidly angiogenesis of biomaterial scaffold.
- 8 November 2013
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 14 (1) , 318
Open AccessDevelopment of a new pre-vascularized tissue-engineered construct using pre-differentiated rADSCs, arteriovenous vascular bundle and porous nano-hydroxyapatide-polyamide 66 scaffold
Background: Development of a pre-vascularized tissue-engineered construct with intrinsic vascular system for cell growth and tissue formation still faces many difficulties due to the complexity of the vascular network of natural bone tissue. The present study was to design and form a new vascularized tissue-engineered construct using pre-differentiated rADSCs, arteriovenous vascular bundle and porous nHA-PA 66 scaffold. Methods: rADSCs were pre-differentiated to endothelial cells (rADSCs-Endo) and then incorporated in nHA-PA 66 scaffolds in vitro. Subsequently, in vivo experiments were carried out according to the following groups: Group A (rADSCs-Endo/nHA-PA 66 scaffold with arteriovenous vascular bundle), Group B (rADSCs/nHA-PA 66 scaffold with arteriovenous vascular bundle); Group C (nHA-PA66 scaffold with arteriovenous vascular bundle), Group D (nHA-PA 66 scaffold only). The vessel density and vessel diameter were measured based on histological and immunohistochemical evaluation, furthermore, the VEGF-C, FGF-2 and BMP-2 protein expressions were also evaluated by western blot analysis. Results: The results of in vivo experiments showed that the vessel density and vessel diameter in group A were significantly higher than the other three groups. Between Group B and C, no statistical difference was observed at each time point. In accordance with the results, there were dramatically higher expressions of VEGF-C and FGF-2 protein in Group A than that of Group B, C and D at 2 or 4 weeks. Statistical differences were not observed in VEGF-C and FGF-2 expression between Group B and C. BMP-2 was not expressed in any group at each time point. Conclusions: Compared with muscular wrapping method, arteriovenous vascular bundle implantation could promote vascularization of the scaffold; and the angiogenesis of the scaffold was significantly accelerated when pre-differentiated rADSCs (endothelial differentiation) were added. These positive results implicate the combination of pre-differentiated rADSCs (endothelial differentiation) and arteriovenous vascular bundle may achieve rapidly angiogenesis of biomaterial scaffold.
- Open Access
- 15 June 2012
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 101
Changes of gluteus medius muscle in the adult patients with unilateral developmental dysplasia of the hip
Background: The gluteus medius muscle is essential for gait and hip stability. Changes that occur in the gluteus medius muscles in patients with developmental dysplasia of the hip (DDH) are not well understood. A better understanding of DDH related changes will have positive repercussions toward hip soft tissue reconstruction.Methods: 19 adult patients with unilateral DDH scheduled for total hip arthroplasty were assessed for: cross-sectional area (CSA), radiological density (RD) and the length of gluteus medius using computed tomograhpy(CT) (scanned before THA). Hip abductor moment arm and gluteus medius activation angle were also measuredviahip anteroposterior radiographs.Results: Both CSA and RD of gluteus medius muscle were significantly reduced (p < 0.05) in the affected hip compared to the control. In the affected hip, the length of the gluteus medius muscle was reduced by 8-11 % (p < 0.05) while the gluteus medius activation angle was significantly increased (p < 0.05) and the hip abductor moment arm was decreased (p < 0.05).Conclusions: The gluteus medius showed substantial loss of CSA, RD as well as decreased length in patients with DDH in the affected hip. These changes should be considered in both hip reconstruction and postoperative rehabilitation training in patients with DDH.
- 15 June 2012
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 101
Open AccessChanges of gluteus medius muscle in the adult patients with unilateral developmental dysplasia of the hip
Background: The gluteus medius muscle is essential for gait and hip stability. Changes that occur in the gluteus medius muscles in patients with developmental dysplasia of the hip (DDH) are not well understood. A better understanding of DDH related changes will have positive repercussions toward hip soft tissue reconstruction.Methods: 19 adult patients with unilateral DDH scheduled for total hip arthroplasty were assessed for: cross-sectional area (CSA), radiological density (RD) and the length of gluteus medius using computed tomograhpy(CT) (scanned before THA). Hip abductor moment arm and gluteus medius activation angle were also measuredviahip anteroposterior radiographs.Results: Both CSA and RD of gluteus medius muscle were significantly reduced (p < 0.05) in the affected hip compared to the control. In the affected hip, the length of the gluteus medius muscle was reduced by 8-11 % (p < 0.05) while the gluteus medius activation angle was significantly increased (p < 0.05) and the hip abductor moment arm was decreased (p < 0.05).Conclusions: The gluteus medius showed substantial loss of CSA, RD as well as decreased length in patients with DDH in the affected hip. These changes should be considered in both hip reconstruction and postoperative rehabilitation training in patients with DDH.
- 1 November 2005
- Vol. 19 (11) , 875-8
[Effect of olfactory ensheathing cells transplantation on protecting spinal cord and neurons after peripheral nerve injury].
To study the effect of olfactory ensheathing cells (OECs) transplantation on protecting spinal cord and neurons after peripheral nerve injury. Fifty-five SD rats were randomly divided into blank group (n = 5), experimental group (n = 25) and control group (n = 25). The right sciatic nerves of all the rats were transected. The proximal end was embedded in muscle and treated with OECs (experimental group) and DMEM (control group). No treatment was given to the blank group. The rats were sacrificed 1, 2, 3, 7, and 14 days after the transplantation, the related neurons were observed with histological and TUNEL methods. After sciatic nerves were transected, death of neurons occurred in spinal cord and ganglion. One, 2, 3 days after treatment, the neuron survival rate in experimental group was 98.4% +/- 6.5%, 97.6% +/- 6.5%, 95.2% +/- 6.7% respectively. The neuron survival rate in control group was 97.8% +/- 6.7%, 97.4% +/- 6.4%, 94.3% +/- 6.8% 1, 2, and 3 days after treatment respectively. There was no significant difference between experimental group and control group. Seven and 14 days after treatment, the neuron survival rate in experimental group was 92.4% +/- 8.9%, 87.7% +/- 9.4% respectively. The neuron survival rate in control group was 87.4% +/- 8.6%, 83.4% +/- 8.5% 7 and 14 days after treatment respectively. There was significant difference between experimental group and control group. On 1st and 2nd day, no apoptosis was seen in spinal cord anterior horn of the rats in both experimental group and control group. On 3rd, 7th, and 14th day, the apoptosis index of spinal cord anterior horn motoneuron in experimental rats were lower (1.2+/-0.8, 1.4 +/- 0. 6, 4.1 +/- 1. 3) than that in the control group (2.1 +/- 1.1, 3.1 +/- 1.1, 6.1 +/- 1.8) (P < 0.05). One, 2, and 3 days after the operation, no ganglion neurons apoptosis was observed in all rats. On 7th day the apoptosis index of ganglion neurons in experimental group(2.10 +/- 0.32) were lower than that in control group (4.40+/-0.56) (P<0.05). On 14th day there was no significant difference in the apoptosis index of ganglion neurons between experimental group (4.30+/-1.80) and control group (6.70 +/- 2.50) (P<0.05). Apoptosis of neurons occur after peripheral nerve injury in spinal cord and ganglion. OECs transplantation is effective in preventing apoptosis.
- 1 November 2005
- Vol. 19 (11) , 875-8
[Effect of olfactory ensheathing cells transplantation on protecting spinal cord and neurons after peripheral nerve injury].
To study the effect of olfactory ensheathing cells (OECs) transplantation on protecting spinal cord and neurons after peripheral nerve injury. Fifty-five SD rats were randomly divided into blank group (n = 5), experimental group (n = 25) and control group (n = 25). The right sciatic nerves of all the rats were transected. The proximal end was embedded in muscle and treated with OECs (experimental group) and DMEM (control group). No treatment was given to the blank group. The rats were sacrificed 1, 2, 3, 7, and 14 days after the transplantation, the related neurons were observed with histological and TUNEL methods. After sciatic nerves were transected, death of neurons occurred in spinal cord and ganglion. One, 2, 3 days after treatment, the neuron survival rate in experimental group was 98.4% +/- 6.5%, 97.6% +/- 6.5%, 95.2% +/- 6.7% respectively. The neuron survival rate in control group was 97.8% +/- 6.7%, 97.4% +/- 6.4%, 94.3% +/- 6.8% 1, 2, and 3 days after treatment respectively. There was no significant difference between experimental group and control group. Seven and 14 days after treatment, the neuron survival rate in experimental group was 92.4% +/- 8.9%, 87.7% +/- 9.4% respectively. The neuron survival rate in control group was 87.4% +/- 8.6%, 83.4% +/- 8.5% 7 and 14 days after treatment respectively. There was significant difference between experimental group and control group. On 1st and 2nd day, no apoptosis was seen in spinal cord anterior horn of the rats in both experimental group and control group. On 3rd, 7th, and 14th day, the apoptosis index of spinal cord anterior horn motoneuron in experimental rats were lower (1.2+/-0.8, 1.4 +/- 0. 6, 4.1 +/- 1. 3) than that in the control group (2.1 +/- 1.1, 3.1 +/- 1.1, 6.1 +/- 1.8) (P < 0.05). One, 2, and 3 days after the operation, no ganglion neurons apoptosis was observed in all rats. On 7th day the apoptosis index of ganglion neurons in experimental group(2.10 +/- 0.32) were lower than that in control group (4.40+/-0.56) (P<0.05). On 14th day there was no significant difference in the apoptosis index of ganglion neurons between experimental group (4.30+/-1.80) and control group (6.70 +/- 2.50) (P<0.05). Apoptosis of neurons occur after peripheral nerve injury in spinal cord and ganglion. OECs transplantation is effective in preventing apoptosis.