Thomas F. Floyd
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas F. Floyd has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Li
Department of Radiology, Department of Bioengineering, Laboratory for Structural NMRImaging (LSNI), Philadelphia, PA, USA
3 shared publications - Emile R. Mohler
Department of Medicine, Cardiovascular Division, Section of Vascular Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States
3 shared publications - Erin K. Englund
Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
3 shared publications - Felix. W. Wehrli
Laboratory for Structural, Physiologic and Functional Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
3 shared publications - Michael C. Langham
Laboratory for Structural, Physiologic and Functional Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, PA
3 shared publications - Zachary B Rodgers
Department of Radiology, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA, 19104, USA
2 shared publications
Latest Publications
- Open Access
- 1 December 2015
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 123 (6) , 1362-1373
Fiber-optic Monitoring of Spinal Cord Hemodynamics in Experimental Aortic Occlusion
The fiber-optic probe can be placed percutaneously into the epidural space of anesthetized sheep. Changes in blood flow detected by the probe correlated with microsphere-detected changes in spinal cord blood flow during occlusion and deocclusion of the thoracic aorta. Changes in spinal cord blood flow detected by the fiber-optic probe were markedly more rapid in onset than functional changes detected by motor-evoked responses. Supplemental Digital Content is available in the text. Background: Spinal cord ischemia occurs frequently during thoracic aneurysm repair. Current methods based on electrophysiology techniques to detect ischemia are indirect, non-specific, and temporally slow. In this article, the authors report the testing of a spinal cord blood flow and oxygenation monitor, based on diffuse correlation and optical spectroscopies, during aortic occlusion in a sheep model. Methods: Testing was carried out in 16 Dorset sheep. Sensitivity in detecting spinal cord blood flow and oxygenation changes during aortic occlusion, pharmacologically induced hypotension and hypertension, and physiologically induced hypoxia/hypercarbia was assessed. Accuracy of the diffuse correlation spectroscopy measurements was determined via comparison with microsphere blood flow measurements. Precision was assessed through repeated measurements in response to pharmacologic interventions. Results: The fiber-optic probe can be placed percutaneously and is capable of continuously measuring spinal cord blood flow and oxygenation preoperatively, intraoperatively, and postoperatively. The device is sensitive to spinal cord blood flow and oxygenation changes associated with aortic occlusion, immediately detecting a decrease in blood flow (−65 ± 32%; n = 32) and blood oxygenation (−17 ± 13%, n = 11) in 100% of trials. Comparison of spinal cord blood flow measurements by the device with microsphere measurements led to a correlation of R 2 = 0.49, P < 0.01, and the within-sheep coefficient of variation was 9.69%. Finally, diffuse correlation spectroscopy is temporally more sensitive to ischemic interventions than motor-evoked potentials. Conclusion: The first-generation spinal fiber-optic monitoring device offers a novel and potentially important step forward in the monitoring of spinal cord ischemia.
- 1 December 2015
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 123 (6) , 1362-1373
Open AccessFiber-optic Monitoring of Spinal Cord Hemodynamics in Experimental Aortic Occlusion
The fiber-optic probe can be placed percutaneously into the epidural space of anesthetized sheep. Changes in blood flow detected by the probe correlated with microsphere-detected changes in spinal cord blood flow during occlusion and deocclusion of the thoracic aorta. Changes in spinal cord blood flow detected by the fiber-optic probe were markedly more rapid in onset than functional changes detected by motor-evoked responses. Supplemental Digital Content is available in the text. Background: Spinal cord ischemia occurs frequently during thoracic aneurysm repair. Current methods based on electrophysiology techniques to detect ischemia are indirect, non-specific, and temporally slow. In this article, the authors report the testing of a spinal cord blood flow and oxygenation monitor, based on diffuse correlation and optical spectroscopies, during aortic occlusion in a sheep model. Methods: Testing was carried out in 16 Dorset sheep. Sensitivity in detecting spinal cord blood flow and oxygenation changes during aortic occlusion, pharmacologically induced hypotension and hypertension, and physiologically induced hypoxia/hypercarbia was assessed. Accuracy of the diffuse correlation spectroscopy measurements was determined via comparison with microsphere blood flow measurements. Precision was assessed through repeated measurements in response to pharmacologic interventions. Results: The fiber-optic probe can be placed percutaneously and is capable of continuously measuring spinal cord blood flow and oxygenation preoperatively, intraoperatively, and postoperatively. The device is sensitive to spinal cord blood flow and oxygenation changes associated with aortic occlusion, immediately detecting a decrease in blood flow (−65 ± 32%; n = 32) and blood oxygenation (−17 ± 13%, n = 11) in 100% of trials. Comparison of spinal cord blood flow measurements by the device with microsphere measurements led to a correlation of R 2 = 0.49, P < 0.01, and the within-sheep coefficient of variation was 9.69%. Finally, diffuse correlation spectroscopy is temporally more sensitive to ischemic interventions than motor-evoked potentials. Conclusion: The first-generation spinal fiber-optic monitoring device offers a novel and potentially important step forward in the monitoring of spinal cord ischemia.
- Top Cited Papers
- 3 June 2014
- Published by Wolters Kluwer Health in Circulation
- Vol. 129 (22) , 2253-2261
Stroke After Aortic Valve Surgery
Background—: The incidence and impact of clinical stroke and silent radiographic cerebral infarction complicating open surgical aortic valve replacement (AVR) are poorly characterized. Methods and Results—: We performed a prospective cohort study of subjects ≥65 years of age who were undergoing AVR for calcific aortic stenosis. Subjects were evaluated by neurologists preoperatively and postoperatively and underwent postoperative magnetic resonance imaging. Over a 4-year period, 196 subjects were enrolled at 2 sites (mean age, 75.8±6.2 years; 36% women; 6% nonwhite). Clinical strokes were detected in 17%, transient ischemic attack in 2%, and in-hospital mortality was 5%. The frequency of stroke in the Society for Thoracic Surgery database in this cohort was 7%. Most strokes were mild; the median National Institutes of Health Stroke Scale was 3 (interquartile range, 1–9). Clinical stroke was associated with increased length of stay (median, 12 versus 10 days; P =0.02). Moderate or severe stroke (National Institutes of Health Stroke Scale ≥10) occurred in 8 (4%) and was strongly associated with in-hospital mortality (38% versus 4%; P =0.005). Of the 109 stroke-free subjects with postoperative magnetic resonance imaging, silent infarct was identified in 59 (54%). Silent infarct was not associated with in-hospital mortality or increased length of stay. Conclusions—: Clinical stroke after AVR was more common than reported previously, more than double for this same cohort in the Society for Thoracic Surgery database, and silent cerebral infarctions were detected in more than half of the patients undergoing AVR. Clinical stroke complicating AVR is associated with increased length of stay and mortality.
- 3 June 2014
- Published by Wolters Kluwer Health in Circulation
- Vol. 129 (22) , 2253-2261
Top Cited PapersStroke After Aortic Valve Surgery
Background—: The incidence and impact of clinical stroke and silent radiographic cerebral infarction complicating open surgical aortic valve replacement (AVR) are poorly characterized. Methods and Results—: We performed a prospective cohort study of subjects ≥65 years of age who were undergoing AVR for calcific aortic stenosis. Subjects were evaluated by neurologists preoperatively and postoperatively and underwent postoperative magnetic resonance imaging. Over a 4-year period, 196 subjects were enrolled at 2 sites (mean age, 75.8±6.2 years; 36% women; 6% nonwhite). Clinical strokes were detected in 17%, transient ischemic attack in 2%, and in-hospital mortality was 5%. The frequency of stroke in the Society for Thoracic Surgery database in this cohort was 7%. Most strokes were mild; the median National Institutes of Health Stroke Scale was 3 (interquartile range, 1–9). Clinical stroke was associated with increased length of stay (median, 12 versus 10 days; P =0.02). Moderate or severe stroke (National Institutes of Health Stroke Scale ≥10) occurred in 8 (4%) and was strongly associated with in-hospital mortality (38% versus 4%; P =0.005). Of the 109 stroke-free subjects with postoperative magnetic resonance imaging, silent infarct was identified in 59 (54%). Silent infarct was not associated with in-hospital mortality or increased length of stay. Conclusions—: Clinical stroke after AVR was more common than reported previously, more than double for this same cohort in the Society for Thoracic Surgery database, and silent cerebral infarctions were detected in more than half of the patients undergoing AVR. Clinical stroke complicating AVR is associated with increased length of stay and mortality.
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 70
Combined measurement of perfusion, venous oxygen saturation, and skeletal muscle T2* during reactive hyperemia in the leg
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 70
Open AccessCombined measurement of perfusion, venous oxygen saturation, and skeletal muscle T2* during reactive hyperemia in the leg
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 17
Quantitative CMR markers of impaired vascular reactivity associated with age and peripheral artery disease
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 17
Open AccessQuantitative CMR markers of impaired vascular reactivity associated with age and peripheral artery disease
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 100
Vessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 100
Open AccessVessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo