Yee-Peng Teh
Yee-Peng Teh has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aik-Hwee Eng
Ansell Healthcare Products LLC, S&T Innovation Centre, 40000 Shah Alam Selangor, Malaysia
1 shared publication - Bit New Yee
Science & Technology Innovation Centre, Ansell Shah Alam, 40000, Shah Alam, Selangor, Malaysia
1 shared publication - Johannes Leitgeb
Department of Traumatology, Medical University of Vienna, Vienna, Austria
1 shared publication - Ojan Assadian
Institute for Skin Integrity, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK
1 shared publication - Rupert Schuster
Department of Orthopedics and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
1 shared publication - Verena Dosch
Department for Hospital Hygiene, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
1 shared publication
Latest Publications
- Open Access
- 11 October 2013
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
- Vol. 2 (1) , 27
In-vitro experimental evaluation of skin-to-surface recovery of four bacterial species by antibacterial and non-antibacterial medical examination gloves
Background: The number of bacteria recovered from a stainless steel coupon after touching a pigskin substrate with an examination glove coated on its outside with polyhexanide (PHMB), as compared to the number of bacteria recovered in the same manner with non-coated control gloves was evaluated. Methods: Suspensions containing 1 × 109 colony-forming units of 4 clinically relevant bacterial species (Enterococcus faecium ATCC #51559; Escherichia coli ATCC #25922; Klebsiella pneumoniae ATCC #4352; and Staphylococcus aureus ATCC #33591) were used to contaminate Gamma-irradiated pigskin substrates. Bacterial recoveries from the pigskin substrate, stainless steel coupons, and each glove swatch were performed. A difference in the bacterial recovery from the stainless steel coupons after touching with coated and uncoated control gloves was measured. Results: For E. faecium, the coated glove showed a reduction of 4.63 log10 cfu recovery, when compared to control gloves. For E. coli, the coated glove showed 5.48 log10 cfu, for K. pneumoniae 5.03 log10 cfu, and for S. aureus 5.72 log10 cfu recovery, when compared to the non-coated control glove. Conclusion: An in-vitro experiment designed to mimic cross-contamination of clinically relevant bacteria in a simulated healthcare setting following glove contact with a contaminated biological surface and cross-transfer to a stainless steel surface has demonstrated that an examination glove coated on its outside surface with PHMB was able to reduce bacterial recovery from a contaminated surface by > 4 log10 cfu, compared to a control non-coated examination glove. These elaborated results may encourage further clinical investigation on the clinical impact of an antibacterial examination glove.
- 11 October 2013
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
- Vol. 2 (1) , 27
Open AccessIn-vitro experimental evaluation of skin-to-surface recovery of four bacterial species by antibacterial and non-antibacterial medical examination gloves
Background: The number of bacteria recovered from a stainless steel coupon after touching a pigskin substrate with an examination glove coated on its outside with polyhexanide (PHMB), as compared to the number of bacteria recovered in the same manner with non-coated control gloves was evaluated. Methods: Suspensions containing 1 × 109 colony-forming units of 4 clinically relevant bacterial species (Enterococcus faecium ATCC #51559; Escherichia coli ATCC #25922; Klebsiella pneumoniae ATCC #4352; and Staphylococcus aureus ATCC #33591) were used to contaminate Gamma-irradiated pigskin substrates. Bacterial recoveries from the pigskin substrate, stainless steel coupons, and each glove swatch were performed. A difference in the bacterial recovery from the stainless steel coupons after touching with coated and uncoated control gloves was measured. Results: For E. faecium, the coated glove showed a reduction of 4.63 log10 cfu recovery, when compared to control gloves. For E. coli, the coated glove showed 5.48 log10 cfu, for K. pneumoniae 5.03 log10 cfu, and for S. aureus 5.72 log10 cfu recovery, when compared to the non-coated control glove. Conclusion: An in-vitro experiment designed to mimic cross-contamination of clinically relevant bacteria in a simulated healthcare setting following glove contact with a contaminated biological surface and cross-transfer to a stainless steel surface has demonstrated that an examination glove coated on its outside surface with PHMB was able to reduce bacterial recovery from a contaminated surface by > 4 log10 cfu, compared to a control non-coated examination glove. These elaborated results may encourage further clinical investigation on the clinical impact of an antibacterial examination glove.