Michelle. J. Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michelle. J. Johnson has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Brinda Ramachandran
Student Member, IEEE, graduate student, Department of Biomedical Engineering, Marquette University, Milwaukee, WI, 53233; Rehabilitation Robotics Research and Design Lab, Zablocki VA Medical Center, Milwaukee, WI 53295
4 shared publications - Ruta P. Paranjape
Student Member, IEEE, graduate student, Department of Biomedical Engineering, Marquette University, Milwaukee, WI, 53233; Rehabilitation Robotics Research and Design Lab, Zablocki VA Medical Center, Milwaukee, WI 53295
4 shared publications - Dominic E. Nathan
Department of Biomedical Engineering, Marquette University, Milwaukee, WI 53233, USA
3 shared publications Elaine Strachota
Department of Occupational Therapy, Milwaukee Area Technical College, Milwaukee, USA
2 shared publications- Judith B. Kosasih
MD, Assistant Professor, Department of Physical Medicine and Rehabilitation, Medical College of Wisconsin, Milwaukee WI 53226
2 shared publications - Benedict Hui
Physical Medicine and Rehabilitation, MCW, Milwaukee, WI, USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2013
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 10 (1) , 105
Remote vibrotactile noise improves light touch sensation in stroke survivors’ fingertips via stochastic resonance
Stroke rehabilitation does not often integrate both sensory and motor recovery. While subthreshold noise was shown to enhance sensory signal detection at the site of noise application, having a noise-generating device at the fingertip to enhance fingertip sensation and potentially enhance dexterity for stroke survivors is impractical, since the device would interfere with object manipulation. This study determined if remote application of subthreshold vibrotactile noise (away from the fingertips) improves fingertip tactile sensation with potential to enhance dexterity for stroke survivors. Index finger and thumb pad sensation was measured for ten stroke survivors with fingertip sensory deficit using the Semmes-Weinstein Monofilament and Two-Point Discrimination Tests. Sensation scores were measured with noise applied at one of three intensities (40%, 60%, 80% of the sensory threshold) to one of four locations of the paretic upper extremity (dorsal hand proximal to the index finger knuckle, dorsal hand proximal to the thumb knuckle, dorsal wrist, volar wrist) in a random order, as well as without noise at beginning (Pre) and end (Post) of the testing session. Vibrotactile noise of all intensities and locations instantaneously and significantly improved Monofilament scores of the index fingertip and thumb tip (p < .01). No significant effect of the noise was seen for the Two-Point Discrimination Test scores. Remote application of subthreshold (imperceptible) vibrotactile noise at the wrist and dorsal hand instantaneously improved stroke survivors' light touch sensation, independent of noise location and intensity. Vibrotactile noise at the wrist and dorsal hand may have enhanced the fingertips' light touch sensation via stochastic resonance and interneuronal connections. While long-term benefits of noise in stroke patients warrants further investigation, this result demonstrates potential that a wearable device applying vibrotactile noise at the wrist could enhance sensation and grip ability without interfering with object manipulation in everyday tasks.
- 1 January 2013
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 10 (1) , 105
Open AccessRemote vibrotactile noise improves light touch sensation in stroke survivors’ fingertips via stochastic resonance
Stroke rehabilitation does not often integrate both sensory and motor recovery. While subthreshold noise was shown to enhance sensory signal detection at the site of noise application, having a noise-generating device at the fingertip to enhance fingertip sensation and potentially enhance dexterity for stroke survivors is impractical, since the device would interfere with object manipulation. This study determined if remote application of subthreshold vibrotactile noise (away from the fingertips) improves fingertip tactile sensation with potential to enhance dexterity for stroke survivors. Index finger and thumb pad sensation was measured for ten stroke survivors with fingertip sensory deficit using the Semmes-Weinstein Monofilament and Two-Point Discrimination Tests. Sensation scores were measured with noise applied at one of three intensities (40%, 60%, 80% of the sensory threshold) to one of four locations of the paretic upper extremity (dorsal hand proximal to the index finger knuckle, dorsal hand proximal to the thumb knuckle, dorsal wrist, volar wrist) in a random order, as well as without noise at beginning (Pre) and end (Post) of the testing session. Vibrotactile noise of all intensities and locations instantaneously and significantly improved Monofilament scores of the index fingertip and thumb tip (p < .01). No significant effect of the noise was seen for the Two-Point Discrimination Test scores. Remote application of subthreshold (imperceptible) vibrotactile noise at the wrist and dorsal hand instantaneously improved stroke survivors' light touch sensation, independent of noise location and intensity. Vibrotactile noise at the wrist and dorsal hand may have enhanced the fingertips' light touch sensation via stochastic resonance and interneuronal connections. While long-term benefits of noise in stroke patients warrants further investigation, this result demonstrates potential that a wearable device applying vibrotactile noise at the wrist could enhance sensation and grip ability without interfering with object manipulation in everyday tasks.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 146-149
An MR safe algometer to study phantom and residual limb pain
Researchers are interested in understanding phantom limb pain (PLP) and residual limb pain (RLP) in amputees and the neural mechanisms leading to it. fMRI can provide information on the intensity and the location of activated centers in the brain that control PLP and RLP. MR safe algometers are important to this work. This paper described the new pneumatically actuated algometer and the evaluation methods for MR safety. Our results indicate that the custom device is an improved MR safe algometer capable of autonomously producing reproducible pressure profiles.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 146-149
An MR safe algometer to study phantom and residual limb pain
Researchers are interested in understanding phantom limb pain (PLP) and residual limb pain (RLP) in amputees and the neural mechanisms leading to it. fMRI can provide information on the intensity and the location of activated centers in the brain that control PLP and RLP. MR safe algometers are important to this work. This paper described the new pneumatically actuated algometer and the evaluation methods for MR safety. Our results indicate that the custom device is an improved MR safe algometer capable of autonomously producing reproducible pressure profiles.
- 1 September 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (10) , 1157-1171
Bilateral assessment of functional tasks for robot-assisted therapy applications
This article presents a novel evaluation system along with methods to evaluate bilateral coordination of arm function on activities of daily living tasks before and after robot-assisted therapy. An affordable bilateral assessment system (BiAS) consisting of two mini-passive measuring units modeled as three degree of freedom robots is described. The process for evaluating functional tasks using the BiAS is presented and we demonstrate its ability to measure wrist kinematic trajectories. Three metrics, phase difference, movement overlap, and task completion time, are used to evaluate the BiAS system on a bilateral symmetric (bi-drink) and a bilateral asymmetric (bi-pour) functional task. Wrist position and velocity trajectories are evaluated using these metrics to provide insight into temporal and spatial bilateral deficits after stroke. The BiAS system quantified movements of the wrists during functional tasks and detected differences in impaired and unimpaired arm movements. Case studies showed that stroke patients compared to healthy subjects move slower and are less likely to use their arm simultaneously even when the functional task requires simultaneous movement. After robot-assisted therapy, interlimb coordination spatial deficits moved toward normal coordination on functional tasks.
- 1 September 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (10) , 1157-1171
Bilateral assessment of functional tasks for robot-assisted therapy applications
This article presents a novel evaluation system along with methods to evaluate bilateral coordination of arm function on activities of daily living tasks before and after robot-assisted therapy. An affordable bilateral assessment system (BiAS) consisting of two mini-passive measuring units modeled as three degree of freedom robots is described. The process for evaluating functional tasks using the BiAS is presented and we demonstrate its ability to measure wrist kinematic trajectories. Three metrics, phase difference, movement overlap, and task completion time, are used to evaluate the BiAS system on a bilateral symmetric (bi-drink) and a bilateral asymmetric (bi-pour) functional task. Wrist position and velocity trajectories are evaluated using these metrics to provide insight into temporal and spatial bilateral deficits after stroke. The BiAS system quantified movements of the wrists during functional tasks and detected differences in impaired and unimpaired arm movements. Case studies showed that stroke patients compared to healthy subjects move slower and are less likely to use their arm simultaneously even when the functional task requires simultaneous movement. After robot-assisted therapy, interlimb coordination spatial deficits moved toward normal coordination on functional tasks.
- 1 January 2011
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 56 (1) , 5-9
Low-cost monitoring of patients during unsupervised robot/computer assisted motivating stroke rehabilitation
There is a need for effective stroke rehabilitation systems that can be used in undersupervised/unsupervised environments such as the home to assist in improving and/or sustaining functional outcomes. We determined the stability, accuracy and usability of an extremely low-cost mobile robot for use with a robot/computer motivating rehabilitation device, TheraDrive. The robot provided cues to discourage excessive trunk movements and to encourage arm movements. The mobile robot system was positively received by potential users, and it was accurate and stable over time. Feedback from users suggests that finding the optimal frequency and type of encouragement and corrective feedback given by the robot helper will be critical for long-term acceptance.
- 1 January 2011
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 56 (1) , 5-9
Low-cost monitoring of patients during unsupervised robot/computer assisted motivating stroke rehabilitation
There is a need for effective stroke rehabilitation systems that can be used in undersupervised/unsupervised environments such as the home to assist in improving and/or sustaining functional outcomes. We determined the stability, accuracy and usability of an extremely low-cost mobile robot for use with a robot/computer motivating rehabilitation device, TheraDrive. The robot provided cues to discourage excessive trunk movements and to encourage arm movements. The mobile robot system was positively received by potential users, and it was accurate and stable over time. Feedback from users suggests that finding the optimal frequency and type of encouragement and corrective feedback given by the robot helper will be critical for long-term acceptance.
- 1 January 2009
- Published by Journal of Rehabilitation Research & Development in Journal of Rehabilitation Research and Development
- Vol. 46 (5) , 587-602
Design and validation of low-cost assistive glove for hand assessment and therapy during activity of daily living-focused robotic stroke therapy
Hand and arm impairment is common after stroke. Robotic stroke therapy will be more effective if hand and upper-arm training is integrated to help users practice reaching and grasping tasks. This article presents the design, development, and validation of a low-cost, functional electrical stimulation grasp-assistive glove for use with task-oriented robotic stroke therapy. Our glove measures grasp aperture while a user completes simple-to-complex real-life activities, and when combined with an integrated functional electrical stimulator, it assists in hand opening and closing. A key function is a new grasp-aperture prediction model, which uses the position of the end-effectors of two planar robots to define the distance between the thumb and index finger. We validated the accuracy and repeatability of the glove and its capability to assist in grasping. Results from five nondisabled subjects indicated that the glove is accurate and repeatable for both static hand-open and -closed tasks when compared with goniometric measures and for dynamic reach-to-grasp tasks when compared with motion analysis measures. Results from five subjects with stroke showed that with the glove, they could open their hands but without it could not. We present a glove that is a low-cost solution for in vivo grasp measurement and assistance.
- 1 January 2009
- Published by Journal of Rehabilitation Research & Development in Journal of Rehabilitation Research and Development
- Vol. 46 (5) , 587-602
Design and validation of low-cost assistive glove for hand assessment and therapy during activity of daily living-focused robotic stroke therapy
Hand and arm impairment is common after stroke. Robotic stroke therapy will be more effective if hand and upper-arm training is integrated to help users practice reaching and grasping tasks. This article presents the design, development, and validation of a low-cost, functional electrical stimulation grasp-assistive glove for use with task-oriented robotic stroke therapy. Our glove measures grasp aperture while a user completes simple-to-complex real-life activities, and when combined with an integrated functional electrical stimulator, it assists in hand opening and closing. A key function is a new grasp-aperture prediction model, which uses the position of the end-effectors of two planar robots to define the distance between the thumb and index finger. We validated the accuracy and repeatability of the glove and its capability to assist in grasping. Results from five nondisabled subjects indicated that the glove is accurate and repeatable for both static hand-open and -closed tasks when compared with goniometric measures and for dynamic reach-to-grasp tasks when compared with motion analysis measures. Results from five subjects with stroke showed that with the glove, they could open their hands but without it could not. We present a glove that is a low-cost solution for in vivo grasp measurement and assistance.
- 23 January 2008
- Published by Springer Nature in Intelligent Service Robotics
- Vol. 1 (2) , 109-121
Collaborative tele-rehabilitation and robot-mediated therapy for stroke rehabilitation at home or clinic
- 23 January 2008
- Published by Springer Nature in Intelligent Service Robotics
- Vol. 1 (2) , 109-121
Collaborative tele-rehabilitation and robot-mediated therapy for stroke rehabilitation at home or clinic
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457898,p. 943-950
Design of a Grasp Assistive Glove for ADL-focused, Robotic Assisted Therapy after Stroke
Reaching to grasp is an essential process in our everyday lives. Individual who suffer a stroke experience major deficits in this ability leading to compromised activities of daily living (ADL), employment, and social interaction. Robotic aided therapy is at the forefront of stroke rehabilitation, however not many systems support functional goal oriented therapy using real world objects. We are interested in designing a grasp assistive component for our ADL-focused robotic therapy environment. This paper reports on the glove development and a static validation study to determine the accuracy and repeatability of the glove in the measurement of joint angles of the thumb and index fingers and grasp aperture, which is the distance between the fingers. Our results showed no significant differences between the glove and a hand-held goniometer for the measured joint angles and the derived grasp aperture. The results suggest that the glove is repeatable and has the potential to measure in vivo grasp aperture during a functional tasks. Our next steps are to complete a dynamic validation study and integrate the glove with our robotic environment.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457898,p. 943-950
Design of a Grasp Assistive Glove for ADL-focused, Robotic Assisted Therapy after Stroke
Reaching to grasp is an essential process in our everyday lives. Individual who suffer a stroke experience major deficits in this ability leading to compromised activities of daily living (ADL), employment, and social interaction. Robotic aided therapy is at the forefront of stroke rehabilitation, however not many systems support functional goal oriented therapy using real world objects. We are interested in designing a grasp assistive component for our ADL-focused robotic therapy environment. This paper reports on the glove development and a static validation study to determine the accuracy and repeatability of the glove in the measurement of joint angles of the thumb and index fingers and grasp aperture, which is the distance between the fingers. Our results showed no significant differences between the glove and a hand-held goniometer for the measured joint angles and the derived grasp aperture. The results suggest that the glove is repeatable and has the potential to measure in vivo grasp aperture during a functional tasks. Our next steps are to complete a dynamic validation study and integrate the glove with our robotic environment.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457898,p. 438-445
Methods for Evaluating Interlimb Coordination for Bimanual Robotic Therapy after Stroke
Deficits in interlimb coordination(IC) contribute to the functional disability in stroke patients. Addressing IC deficits after stroke has been somewhat overlooked in the realm of robotic bilateral stroke interventions. Our goal is to develop a robotic therapy protocol to improve IC for bimanual tasks and to assess changes in IC due to therapy. We evaluated the metrics of phase difference (PD), goal synchronization (GS), task completion time (TCT), % movement overlap (%MO) to determine which are most sensitive to IC on both symmetric and asymmetric bimanual functional tasks (e.g., drink and feed). We assessed IC for able-bodied and strokes. We showed PD, TCT, and %MO to be sensitive to differences in IC across subject groups. PD was more sensitive in the symmetrical task while TCT and %MO were more sensitive in the asymmetrical task. Creating a robotic intervention with these metrics will enable us to explore the efficacy of addressing coordination deficits after stroke.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457898,p. 438-445
Methods for Evaluating Interlimb Coordination for Bimanual Robotic Therapy after Stroke
Deficits in interlimb coordination(IC) contribute to the functional disability in stroke patients. Addressing IC deficits after stroke has been somewhat overlooked in the realm of robotic bilateral stroke interventions. Our goal is to develop a robotic therapy protocol to improve IC for bimanual tasks and to assess changes in IC due to therapy. We evaluated the metrics of phase difference (PD), goal synchronization (GS), task completion time (TCT), % movement overlap (%MO) to determine which are most sensitive to IC on both symmetric and asymmetric bimanual functional tasks (e.g., drink and feed). We assessed IC for able-bodied and strokes. We showed PD, TCT, and %MO to be sensitive to differences in IC across subject groups. PD was more sensitive in the symmetrical task while TCT and %MO were more sensitive in the asymmetrical task. Creating a robotic intervention with these metrics will enable us to explore the efficacy of addressing coordination deficits after stroke.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 3365-3370
Trajectory Planning for Functional Wrist Movements in an ADL-Oriented, Robot-Assisted Therapy Environment
A task-oriented robot-assisted therapy environment to support activities of daily living tasks was developed with the goals of addressing some of the shortcomings of current robotic therapy systems. An important aspect of making these environments work is the implementation of trajectory planning algorithms that support the naturally curving wrist movement seen in real life functional tasks. We explore the challenge of naturally supporting the positioning of the wrist for activities of daily living tasks such as drinking and feeding. In this paper, we examine the minimum jerk model often used to define trajectory planning routines to automatically position the wrist and present the results of fitting these two models to natural wrist movements for a drinking task. Also, we present a case study to examine how an able-bodied experienced the two models as implemented on the ADLER, task-oriented robot-assisted therapy environment.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 3365-3370
Trajectory Planning for Functional Wrist Movements in an ADL-Oriented, Robot-Assisted Therapy Environment
A task-oriented robot-assisted therapy environment to support activities of daily living tasks was developed with the goals of addressing some of the shortcomings of current robotic therapy systems. An important aspect of making these environments work is the implementation of trajectory planning algorithms that support the naturally curving wrist movement seen in real life functional tasks. We explore the challenge of naturally supporting the positioning of the wrist for activities of daily living tasks such as drinking and feeding. In this paper, we examine the minimum jerk model often used to define trajectory planning routines to automatically position the wrist and present the results of fitting these two models to natural wrist movements for a drinking task. Also, we present a case study to examine how an able-bodied experienced the two models as implemented on the ADLER, task-oriented robot-assisted therapy environment.
- Open Access
- 23 March 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 7
Quantifying kinematics of purposeful movements to real, imagined, or absent functional objects: Implications for modelling trajectories for robot-assisted ADL tasks**
Robotic therapy is at the forefront of stroke rehabilitation. The Activities of Daily Living Exercise Robot (ADLER) was developed to improve carryover of gains after training by combining the benefits of Activities of Daily Living (ADL) training (motivation and functional task practice with real objects), with the benefits of robot mediated therapy (repeatability and reliability). In combining these two therapy techniques, we seek to develop a new model for trajectory generation that will support functional movements to real objects during robot training. We studied natural movements to real objects and report on how initial reaching movements are affected by real objects and how these movements deviate from the straight line paths predicted by the minimum jerk model, typically used to generate trajectories in robot training environments. We highlight key issues that to be considered in modelling natural trajectories.
- 23 March 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 7
Open AccessQuantifying kinematics of purposeful movements to real, imagined, or absent functional objects: Implications for modelling trajectories for robot-assisted ADL tasks**
Robotic therapy is at the forefront of stroke rehabilitation. The Activities of Daily Living Exercise Robot (ADLER) was developed to improve carryover of gains after training by combining the benefits of Activities of Daily Living (ADL) training (motivation and functional task practice with real objects), with the benefits of robot mediated therapy (repeatability and reliability). In combining these two therapy techniques, we seek to develop a new model for trajectory generation that will support functional movements to real objects during robot training. We studied natural movements to real objects and report on how initial reaching movements are affected by real objects and how these movements deviate from the straight line paths predicted by the minimum jerk model, typically used to generate trajectories in robot training environments. We highlight key issues that to be considered in modelling natural trajectories.