SCShih-Hao Chen

Shih-Hao Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shih-Hao Chen has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Global Compressive Loading from an Ultra-Thin PEEK Button Augment Enhances Fibrocartilage Regeneration of Rotator Cuff Enthesis

    by Chia-Wei Lin, En-Rung Chiang, Shih-Hao Chen, Poyu Chen, Heng-Jui Liu, Joe Chih-Hao Chiu

    A PEEK button is developed to improve the tendon-to-bone compression area. In total, 18 goats were divided into 12-week, 4-week, and 0-week groups. All underwent bilateral detachment of the infraspinatus tendon. In the 12-week group, 6 were fixed with a 0.8–1 mm-thick PEEK augment (A-12, Augmented), and 6 were fixed with the double-row technique (DR-12). Overall, 6 infraspinatus were fixed with PEEK augment (A-4) and without PEEK augment (DR-4) in the 4-week group. The same condition was performed in the 0-week groups (A-0 and DR-0). Mechanical testing, immunohistochemistry assessment, cell responses, tissue alternation, surgical impact, remodeling, and the expression of type I, II, and III collagen of the native tendon-to-bone insertion and new footprint areas were evaluated. The average maximum load in the A-12 group (393.75 (84.40) N) was significantly larger than in the TOE-12 group (229.17 (43.94) N) (p < 0.001). Cell responses and tissue alternations in the 4-week group were slight. The new footprint area of the A-4 group had better fibrocartilage maturation and more type III collagen expression than in DR-4 group. This result proved the novel device is safe and provides superior load-displacement to the double-row technique. There is a trend toward better fibrocartilage maturation and more collagen III secretions in the PEEK augmentation group.

  • Open Access

    Biomechanical comparison of three stand-alone lumbar cages — a three-dimensional finite element analysis

    by Shih-Hao Chen, Ming-Chieh Chiang, Jin-Fu Lin, Shang-Chih Lin, Ching-Hua Hung

    Background: For anterior lumbar interbody fusion (ALIF), stand-alone cages can be supplemented with vertebral plate, locking screws, or threaded cylinder to avoid the use of posterior fixation. Intuitively, the plate, screw, and cylinder aim to be embedded into the vertebral bodies to effectively immobilize the cage itself. The kinematic and mechanical effects of these integrated components on the lumbar construct have not been extensively studied. A nonlinearly lumbar finite-element model was developed and validated to investigate the biomechanical differences between three stand-alone (Latero, SynFix, and Stabilis) and SynCage-Open plus transpedicular fixation. All four cages were instrumented at the L3-4 level. Methods: The lumbar models were subjected to the follower load along the lumbar column and the moment at the lumbar top to produce flexion (FL), extension (EX), left/right lateral bending (LLB, RLB), and left/right axial rotation (LAR, RAR). A 10 Nm moment was applied to obtain the six physiological motions in all models. The comparison indices included disc range of motion (ROM), facet contact force, and stresses of the annulus and implants. Results: At the surgical level, the SynCage-open model supplemented with transpedicular fixation decreased ROM (>76%) greatly; while the SynFix model decreased ROM 56-72%, the Latero model decreased ROM 36-91%, in all motions as compared with the INT model. However, the Stabilis model decreased ROM slightly in extension (11%), lateral bending (21%), and axial rotation (34%). At the adjacent levels, there were no obvious differences in ROM and annulus stress among all instrumented models. Conclusions: ALIF instrumentation with the Latero or SynFix cage provides an acceptable stability for clinical use without the requirement of additional posterior fixation. However, the Stabilis cage is not favored in extension and lateral bending because of insufficient stabilization.


  • Open Access

    Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery -- a finite element analysis

    by Shih-Hao Chen, Shang-Chih Lin, Wen-Chi Tsai, Chih-Wei Wang, Shih-Heng Chao

    Little is known about the biomechanical effectiveness of transforaminal lumbar interbody fusion (TLIF) cages in different positioning and various posterior implants used after decompressive surgery. The use of the various implants will induce the kinematic and mechanical changes in range of motion (ROM) and stresses at the surgical and adjacent segments. Unilateral pedicle screw with or without supplementary facet screw fixation in the minimally invasive TLIF procedure has not been ascertained to provide adequate stability without the need to expose on the contralateral side. This study used finite element (FE) models to investigate biomechanical differences in ROM and stress on the neighboring structures after TLIF cages insertion in conjunction with posterior fixation.


  • Open Access

    Biomechanical optimization of different fixation modes for a proximal femoral L-osteotomy

    by Ching-Lung Tai, Weng-Pin Chen, Hsih-Hao Chen, Chien-Yu Lin, Mel S Lee

    Background: Numerous proposed surgical techniques have had minimal success in managing greater trochanter overgrowth secondary to retarded growth of the femoral capital epiphysis. For reconstruction of residual hip deformities, a novel type of proximal femur L-osteotomy was performed with satisfactory results. Although the clinical outcome was good, the biomechanical characteristics of the femur after such an osteotomy have not been clearly elucidated. Therefore, this study presents a three dimensional finite element analysis designed to understand the mechanical characteristics of the femur after the L-osteotomy. Methods: A patient with left hip dysplasia was recruited as the study model for L-osteotomy. The normal right hip was used as a reference for performing the corrective surgery. Four FEA models were constructed using different numbers of fixation screws but the same osteotomy lengths together with four FEA models with the same number of fixation screws but different osteotomy lengths. The von Mises stress distributions and femoral head displacements were analyzed and compared. Results: The results revealed the following: 1). The fixation devices (plate and screws) sustained most of the external loading, and the peak value of von Mises stress on the fixation screws decreased with an increasing number of screws. 2). Additional screws are more beneficial on the proximal segment than on the distal segment for improving the stability of the postoperative femur. 3). The extent of osteotomy should be limited because local stress might be concentrated in the femoral neck region with increasing length of the L-osteotomy. Conclusion: Additional screw placement on the proximal segment improves stability in the postoperative femur. The cobra-type plate with additional screw holes in the proximal area might improve the effectiveness of L-osteotomies.


  • Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures

    by Shih-Hao Chen, Tzai-Chiu Yu, Chih-Han Chang, Yuan-Chiao Lu


  • Open Access

    Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques – a three-dimensional finite element analysis

    by Shih-Hao Chen, Ching-Lung Tai, Chien-Yu Lin, Pang-Hsing Hsieh, Weng-Pin Chen

    Initial promise of a stand-alone interbody fusion cage to treat chronic back pain and restore disc height has not been realized. In some instances, a posterior spinal fixation has been used to enhance stability and increase fusion rate. In this manuscript, a new stand-alone cage is compared with conventional fixation methods based on the finite element analysis, with a focus on investigating cage-bone interface mechanics and stress distribution on the adjacent tissues.