Zheng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zheng Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bin Song
Department of Radiation Oncology, Huanhu Hospital, Tianjin, China
1 shared publication - Jing Liu
Department of Radiotherapy, Tianjin First Central Hospital, Tianjin, 300384, China
1 shared publication - Wei Jiang
Department of Radiation Oncology, Tianjin Huanhu Hospital, Tianjin 300060, China.
1 shared publication - Yang Guo
Department of Radiation Oncology, Huanhu Hospital, Tianjin, China
1 shared publication - Yu Guo
Medical School, Tianjin University, China
1 shared publication - Yuanming Feng
Department of Biomedical Engineering, Tianjin University, Tianjin, China
1 shared publication
Latest Publications
- Open Access
- 15 April 2025
- Published by Elsevier in Mutation Research - Reviews in Mutation Research
- Vol. 795, 108536
The landscape of FGFR-TACC fusion in adult glioblastoma: From bench to bedside
- 15 April 2025
- Published by Elsevier in Mutation Research - Reviews in Mutation Research
- Vol. 795, 108536
Open AccessThe landscape of FGFR-TACC fusion in adult glioblastoma: From bench to bedside
- Open Access
- 17 September 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 217
A simple approach of three-isocenter IMRT planning for craniospinal irradiation
Purpose To develop a new IMRT technique to simplify the process and improve efficiency in radiotherapy treatment planning for craniospinal irradiation (CSI) treatment. Methods Image data of 9 patients who received CSI treatment in 2012 were used, the prescription was 36Gy in 20 fractions. Two treatment plans were created for each patient, one was with the new technique called three-isocenter overlap-junction (TIOJ) IMRT and the other was with the three-isocenter jagged-junction (TIJJ) IMRT technique. The comparative study was conducted using the parameters of heterogeneity index (HI), conformity index (CI), and doses to the organs at risk (OARs). Results Comparing the TIOJ IMRT plans with the TIJJ IMRT plans, the average homogeneity index is 0.071 ± 0.003 and 0.077 ± 0.002, respectively, and the averaged conformity number is 0.80 ± 0.012 and 0.80 ± 0.009, respectively. There are no significant differences (p > 0.05). Both plans provide satisfactory sparing for the OARs. Conclusions The TIOJ IMRT technique for CSI treatment planning can create similar plans as with the TIJJ IMRT technique, but the new technique greatly simplifies the steps required to manually set field widths and boundaries and improved efficiency.
- 17 September 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 217
Open AccessA simple approach of three-isocenter IMRT planning for craniospinal irradiation
Purpose To develop a new IMRT technique to simplify the process and improve efficiency in radiotherapy treatment planning for craniospinal irradiation (CSI) treatment. Methods Image data of 9 patients who received CSI treatment in 2012 were used, the prescription was 36Gy in 20 fractions. Two treatment plans were created for each patient, one was with the new technique called three-isocenter overlap-junction (TIOJ) IMRT and the other was with the three-isocenter jagged-junction (TIJJ) IMRT technique. The comparative study was conducted using the parameters of heterogeneity index (HI), conformity index (CI), and doses to the organs at risk (OARs). Results Comparing the TIOJ IMRT plans with the TIJJ IMRT plans, the average homogeneity index is 0.071 ± 0.003 and 0.077 ± 0.002, respectively, and the averaged conformity number is 0.80 ± 0.012 and 0.80 ± 0.009, respectively. There are no significant differences (p > 0.05). Both plans provide satisfactory sparing for the OARs. Conclusions The TIOJ IMRT technique for CSI treatment planning can create similar plans as with the TIJJ IMRT technique, but the new technique greatly simplifies the steps required to manually set field widths and boundaries and improved efficiency.