Qian Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qian Xu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jingwen Mo
School of Mechanical Engineering, Southeast University 1 , Nanjing 210096
2 shared publications - Hubo Sun
Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, No.10 Xitoutiao You An Men, Beijing 100069, China
1 shared publication - Hui Jin
School of Public Health, Southeast University, China
1 shared publication - Hui Wang
Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, No.10 Xitoutiao You An Men, Beijing 100069, China
1 shared publication Jiaying Zeng
School of Public Health, Southeast University, Nanjing, P.R. China
1 shared publication- Jiaying Zeng
School of public health, Southeast University, Nanjing, People’s Republic of China
1 shared publication
Latest Publications
- 4 January 2021
- Published by Springer Nature in Journal of Inorganic and Organometallic Polymers and Materials
- Vol. 31 (7) , 2868-2876
A Fluorescent Sensor for Daunorubicin Determination Using 808 nm-excited Upconversion Nanoparticles
- 4 January 2021
- Published by Springer Nature in Journal of Inorganic and Organometallic Polymers and Materials
- Vol. 31 (7) , 2868-2876
A Fluorescent Sensor for Daunorubicin Determination Using 808 nm-excited Upconversion Nanoparticles
- Open Access
- 28 November 2019
- Published by MDPI AG in Nanomaterials
- Vol. 9 (12) , 1700
An Nd3+-Sensitized Upconversion Fluorescent Sensor for Epirubicin Detection
We describe here an Nd3+-sensitized upconversion fluorescent sensor for epirubicin (EPI) detection in aqueous solutions under 808 nm laser excitation. The upconversion fluorescence of nanoparticles is effectively quenched in the presence of EPI via a fluorescence resonance energy transfer mechanism. The dynamic quenching constant was 2.10 × 104 M−1. Normalized fluorescence intensity increased linearly as the EPI concentration was raised from 0.09 μM to 189.66 μM and the fluorometric detection limit was 0.05 μM. The sensing method was simple, fast, and low-cost and was able to be applied to determine the levels of EPI in urine with spike recoveries from 97.5% to 102.6%. Another important feature of the proposed fluorescent sensor is that it holds a promising potential for in vivo imaging and detection due to its distinctive properties such as weak autofluorescence, low heating effect, and high light penetration depth.
- 28 November 2019
- Published by MDPI AG in Nanomaterials
- Vol. 9 (12) , 1700
Open AccessAn Nd3+-Sensitized Upconversion Fluorescent Sensor for Epirubicin Detection
We describe here an Nd3+-sensitized upconversion fluorescent sensor for epirubicin (EPI) detection in aqueous solutions under 808 nm laser excitation. The upconversion fluorescence of nanoparticles is effectively quenched in the presence of EPI via a fluorescence resonance energy transfer mechanism. The dynamic quenching constant was 2.10 × 104 M−1. Normalized fluorescence intensity increased linearly as the EPI concentration was raised from 0.09 μM to 189.66 μM and the fluorometric detection limit was 0.05 μM. The sensing method was simple, fast, and low-cost and was able to be applied to determine the levels of EPI in urine with spike recoveries from 97.5% to 102.6%. Another important feature of the proposed fluorescent sensor is that it holds a promising potential for in vivo imaging and detection due to its distinctive properties such as weak autofluorescence, low heating effect, and high light penetration depth.
- Open Access
- 6 August 2013
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 10 (1) , 37
Degradation of aqueous synthesized CdTe/ZnS quantum dots in mice: differential blood kinetics and biodistribution of cadmium and tellurium
Background: Quantum dots (QDs) have been used as novel fluorescent nanoprobes for various bioapplications. The degradation of QDs, and consequent release of free cadmium ions, have been suggested to be the causes of their overall toxicity. However, in contrast to sufficient investigations regarding the biological fate of QDs, a paucity of studies have reported their chemical fate in vivo. Therefore, the overall aim of our study was to understand the chemical fate of QDs in vivo and explore analytical techniques or methods that could be used to define the chemical fate of QDs in vivo. Methods: Male ICR mice were administered a single intravenous dose (0.2 μmol/kg) of aqueous synthesized CdTe/ZnS aqQDs. Inductively coupled plasma-mass spectrometry (ICP-MS) was used to simultaneously measure the concentrations of cadmium (Cd) and tellurium (Te) in the blood and tissues over the course of a 28 day period. We compared the blood kinetic parameters and biodistributions of Cd and Te, and used the molar ratio of Cd:Te as a marker for QDs degradation. Results: Cd and Te display different blood kinetics and biodistribution profiles. The Cd:Te ratio in the blood did not vary significantly within the first hour compared with intact CdTe/ZnS aqQDs. The Cd:Te ratio decreased gradually over time from the 6 h time point on. Cd accumulated in the liver, kidneys, and spleen. Te was distributed primarily to the kidneys. Sharp time-dependent increases in the Cd:Te ratio were found in liver tissues. Conclusions: QDs can undergo degradation in vivo. In vitro, QDs are chemically stable and do not elicit the same biological responses or consequences as they do in vivo. Our methods might provide valuable information regarding the degradation of QDs in vivo and may enable the design and development of QDs for biological and biomedical applications.
- 6 August 2013
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 10 (1) , 37
Open AccessDegradation of aqueous synthesized CdTe/ZnS quantum dots in mice: differential blood kinetics and biodistribution of cadmium and tellurium
Background: Quantum dots (QDs) have been used as novel fluorescent nanoprobes for various bioapplications. The degradation of QDs, and consequent release of free cadmium ions, have been suggested to be the causes of their overall toxicity. However, in contrast to sufficient investigations regarding the biological fate of QDs, a paucity of studies have reported their chemical fate in vivo. Therefore, the overall aim of our study was to understand the chemical fate of QDs in vivo and explore analytical techniques or methods that could be used to define the chemical fate of QDs in vivo. Methods: Male ICR mice were administered a single intravenous dose (0.2 μmol/kg) of aqueous synthesized CdTe/ZnS aqQDs. Inductively coupled plasma-mass spectrometry (ICP-MS) was used to simultaneously measure the concentrations of cadmium (Cd) and tellurium (Te) in the blood and tissues over the course of a 28 day period. We compared the blood kinetic parameters and biodistributions of Cd and Te, and used the molar ratio of Cd:Te as a marker for QDs degradation. Results: Cd and Te display different blood kinetics and biodistribution profiles. The Cd:Te ratio in the blood did not vary significantly within the first hour compared with intact CdTe/ZnS aqQDs. The Cd:Te ratio decreased gradually over time from the 6 h time point on. Cd accumulated in the liver, kidneys, and spleen. Te was distributed primarily to the kidneys. Sharp time-dependent increases in the Cd:Te ratio were found in liver tissues. Conclusions: QDs can undergo degradation in vivo. In vitro, QDs are chemically stable and do not elicit the same biological responses or consequences as they do in vivo. Our methods might provide valuable information regarding the degradation of QDs in vivo and may enable the design and development of QDs for biological and biomedical applications.