Hironobu Sou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hironobu Sou has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Akiko Hayakawa
Medical Affairs Department, Business Intelligence Division, DAIICHI SANKYO CO., LTD, 3-5-1, Nihonbashi honcho, Chuo-ku, Tokyo 103-8426, Japan
1 shared publication - Hiroshi Kondo
Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu, Gifu 501-1194, Japan
1 shared publication - Kazuhito Shiosakai
Clinical Data and Biostatistics Department, Daiichi Sankyo Co., Ltd, Tokyo, Japan
1 shared publication - Kazuo Awai
Department of Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
1 shared publication - Kengo Yoshimitsu
Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka City, Japan
1 shared publication - Masahiro Okada
Department of Radiology, Kinki University School of Medicine, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka 589-8511, Japan
1 shared publication
Latest Publications
- Open Access
- 31 July 2013
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 367
The efficacy of contrast protocol in hepatic dynamic computed tomography: multicenter prospective study in community hospitals
To investigate four different contrast protocols to detect hypervascular hepatocellular carcinoma (HCC) most adaptable for patients at any body weight (BW) in clinical practice. A post-marketing surveillance of liver dynamic CT was prospectively performed by four different protocols in 415 patients: Protocol-A, BW-tailored dose of contrast media (CM: iohexol 300 mgI/mL), fixed injection duration (30s), fixed scan timing at arterial phase (AP); Protocol-B, BW-tailored dose of CM, fixed injection duration (30s), by bolus tracking; Protocol-C, BW-tailored dose of CM, fixed injection flow rate, by bolus tracking; Protocol-D, 100 mL constant of CM at any BW, fixed scan timing. Scan timing and tumor conspicuity at AP was scored qualitatively. The quantitative CT values of aorta and tumor liver contrast (TLC) were obtained. The qualitative rate assessed “good” as scan timing of AP in Protocol-C was significantly lower than those in Protocols A and D (difference:16.6%, 17.4%, P = 0.0069, P = 0.0140, respectively). Scatter plot of Protocol-D (R2 = 0.1283) at AP showed significant inverse relationship between TLC and BW (P =0.0053), although not significant in Protocols A, B, C. In patients with higher BW, protocols of BW-tailored dose of CM and/or fixed injection duration have no dependence on BW to diagnose hypervascular HCCs.
- 31 July 2013
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 367
Open AccessThe efficacy of contrast protocol in hepatic dynamic computed tomography: multicenter prospective study in community hospitals
To investigate four different contrast protocols to detect hypervascular hepatocellular carcinoma (HCC) most adaptable for patients at any body weight (BW) in clinical practice. A post-marketing surveillance of liver dynamic CT was prospectively performed by four different protocols in 415 patients: Protocol-A, BW-tailored dose of contrast media (CM: iohexol 300 mgI/mL), fixed injection duration (30s), fixed scan timing at arterial phase (AP); Protocol-B, BW-tailored dose of CM, fixed injection duration (30s), by bolus tracking; Protocol-C, BW-tailored dose of CM, fixed injection flow rate, by bolus tracking; Protocol-D, 100 mL constant of CM at any BW, fixed scan timing. Scan timing and tumor conspicuity at AP was scored qualitatively. The quantitative CT values of aorta and tumor liver contrast (TLC) were obtained. The qualitative rate assessed “good” as scan timing of AP in Protocol-C was significantly lower than those in Protocols A and D (difference:16.6%, 17.4%, P = 0.0069, P = 0.0140, respectively). Scatter plot of Protocol-D (R2 = 0.1283) at AP showed significant inverse relationship between TLC and BW (P =0.0053), although not significant in Protocols A, B, C. In patients with higher BW, protocols of BW-tailored dose of CM and/or fixed injection duration have no dependence on BW to diagnose hypervascular HCCs.