Jens Schriewer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jens Schriewer has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Willam
Medizinische Klinik 4, Universitätsklinikum Erlangen, Erlangen, Deutschland
1 shared publication - Christian Forster
Department of Nephrology and Hypertension, Friedrich-Alexander-University Erlangen-Nuremberg, Ulmenweg 18, Erlangen, 91054, Germany
1 shared publication - Kai-Uwe Eckardt
Department of Nephrology and Hypertension, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
1 shared publication - Stefan John
Zentrum für Intensivmedizin, Klinikum Nürnberg, Nürnberg, Deutschland
1 shared publication
Latest Publications
- Open Access
- 24 July 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (4) , R154
Low-flow CO2removal integrated into a renal-replacement circuit can reduce acidosis and decrease vasopressor requirements
Introduction: Lung-protective ventilation in patients with ARDS and multiorgan failure, including renal failure, is often paralleled with a combined respiratory and metabolic acidosis. We assessed the effectiveness of a hollow-fiber gas exchanger integrated into a conventional renal-replacement circuit on CO2 removal, acidosis, and hemodynamics. Methods: In ten ventilated critically ill patients with ARDS and AKI undergoing renal- and respiratory-replacement therapy, effects of low-flow CO2 removal on respiratory acidosis compensation were tested by using a hollow-fiber gas exchanger added to the renal-replacement circuit. This was an observational study on safety, CO2-removal capacity, effects on pH, ventilator settings, and hemodynamics. Results: CO2 elimination in the low-flow circuit was safe and was well tolerated by all patients. After 4 hours of treatment, a mean reduction of 17.3 mm Hg (−28.1%) pCO2 was observed, in line with an increase in pH. In hemodynamically instable patients, low-flow CO2 elimination was paralleled by hemodynamic improvement, with an average reduction of vasopressors of 65% in five of six catecholamine-dependent patients during the first 24 hours. Conclusions: Because no further catheters are needed, besides those for renal replacement, the implementation of a hollow-fiber gas exchanger in a renal circuit could be an attractive therapeutic tool with only a little additional trauma for patients with mild to moderate ARDS undergoing invasive ventilation with concomitant respiratory acidosis, as long as no severe oxygenation defects indicate ECMO therapy.
- 24 July 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (4) , R154
Open AccessLow-flow CO2removal integrated into a renal-replacement circuit can reduce acidosis and decrease vasopressor requirements
Introduction: Lung-protective ventilation in patients with ARDS and multiorgan failure, including renal failure, is often paralleled with a combined respiratory and metabolic acidosis. We assessed the effectiveness of a hollow-fiber gas exchanger integrated into a conventional renal-replacement circuit on CO2 removal, acidosis, and hemodynamics. Methods: In ten ventilated critically ill patients with ARDS and AKI undergoing renal- and respiratory-replacement therapy, effects of low-flow CO2 removal on respiratory acidosis compensation were tested by using a hollow-fiber gas exchanger added to the renal-replacement circuit. This was an observational study on safety, CO2-removal capacity, effects on pH, ventilator settings, and hemodynamics. Results: CO2 elimination in the low-flow circuit was safe and was well tolerated by all patients. After 4 hours of treatment, a mean reduction of 17.3 mm Hg (−28.1%) pCO2 was observed, in line with an increase in pH. In hemodynamically instable patients, low-flow CO2 elimination was paralleled by hemodynamic improvement, with an average reduction of vasopressors of 65% in five of six catecholamine-dependent patients during the first 24 hours. Conclusions: Because no further catheters are needed, besides those for renal replacement, the implementation of a hollow-fiber gas exchanger in a renal circuit could be an attractive therapeutic tool with only a little additional trauma for patients with mild to moderate ARDS undergoing invasive ventilation with concomitant respiratory acidosis, as long as no severe oxygenation defects indicate ECMO therapy.