Jean-Luc Martinoli
Research Subjects
Research Interests
Jean-Luc Martinoli has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Céline Guinet
Biomnis Laboratories R & D, 78 avenue de Verdun, BP 110,94200 Ivry-sur-Seine, Paris, France
1 shared publication - Elisabeth Perzborn
Formerly Acute Care Diseases Research, Bayer Pharma AG, Wuppertal, Germany
1 shared publication - Gabriele Rohde
Bayer HealthCare AG, Aprather Weg 18a, D-42096 Wuppertal, Germany
1 shared publication - Geneviève Contant
Diagnostica Stago SA, 125 avenue Louis Roche, P.A.E. Parispace 3, 92230 Gennevilliers, France
1 shared publication - Lena Le Flem
Biomnis Laboratories R & D, 78 avenue de Verdun, BP 110,94200 Ivry-sur-Seine, Paris, France
1 shared publication - Meyer Michel Samama
Hôtel-Dieu University Hospital, Paris, France
1 shared publication
Latest Publications
- Open Access
- 1 January 2013
- Published by Springer Nature in Thrombosis Journal
- Vol. 11 (1) , 11
Laboratory assessment of rivaroxaban: a review
Research into new anticoagulants for preventing and treating thromboembolic disorders has focused on targeting single enzymes in the coagulation cascade, particularly Factor Xa and thrombin, inhibition of which greatly decreases thrombin generation. Based on the results of phase III clinical trials, rivaroxaban, a direct Factor Xa inhibitor, has been approved in many countries for the management of several thromboembolic disorders. Owing to its predictable pharmacokinetic and pharmacodynamic characteristics, fixed-dose regimens are used without the need for routine coagulation monitoring. In situations where assessment of rivaroxaban exposure may be helpful, anti-Factor Xa chromogenic assays (in tandem with standard calibration curves generated with the use of rivaroxaban calibrators and controls) could be used. It is important to note that test results will be affected by the timing of blood sampling after rivaroxaban intake. In addition, the anti-Factor Xa method measures the drug concentration and not the intensity of the drug’s anticoagulant activity, and a higher than expected rivaroxaban plasma level does not necessarily indicate an increased risk of bleeding complications. Therefore, clinicians need to consider test results in relation to the pharmacokinetics of rivaroxaban and other patient risk factors associated with bleeding.
- 1 January 2013
- Published by Springer Nature in Thrombosis Journal
- Vol. 11 (1) , 11
Open AccessLaboratory assessment of rivaroxaban: a review
Research into new anticoagulants for preventing and treating thromboembolic disorders has focused on targeting single enzymes in the coagulation cascade, particularly Factor Xa and thrombin, inhibition of which greatly decreases thrombin generation. Based on the results of phase III clinical trials, rivaroxaban, a direct Factor Xa inhibitor, has been approved in many countries for the management of several thromboembolic disorders. Owing to its predictable pharmacokinetic and pharmacodynamic characteristics, fixed-dose regimens are used without the need for routine coagulation monitoring. In situations where assessment of rivaroxaban exposure may be helpful, anti-Factor Xa chromogenic assays (in tandem with standard calibration curves generated with the use of rivaroxaban calibrators and controls) could be used. It is important to note that test results will be affected by the timing of blood sampling after rivaroxaban intake. In addition, the anti-Factor Xa method measures the drug concentration and not the intensity of the drug’s anticoagulant activity, and a higher than expected rivaroxaban plasma level does not necessarily indicate an increased risk of bleeding complications. Therefore, clinicians need to consider test results in relation to the pharmacokinetics of rivaroxaban and other patient risk factors associated with bleeding.