HEHendrik Emons

Hendrik Emons

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hendrik Emons has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Does DNA extraction affect the specificity of a PCR method claiming the specific detectability of a genome-edited plant?

    by Sophia Edelmann, Christian Savini, Dominik Moor, Jörn Lämke, Kathrin Lieske, Marco Mazzara, Hendrik Emons, Joachim Mankertz, Christopher Weidner

    Under current EU legislation, genetically modified organisms (GMOs) and derived food and feed products must be authorized as GM food, feed, or seed and appropriate detection methods must be made available for use in official controls. A Real-Time PCR method has recently been published by Chhalliyil et al. claiming to be specific for the detection and identification of genome-edited oilseed rape (OSR) lines commercialized in North America. In a previous study, we have independently assessed this method in three reference laboratories for sensitivity, specificity, and robustness. We found that the method does not meet all the minimum performance requirements (MPR) for GMO testing in the EU, which contradicts the claims of the method developer. Here we show, in addition to the previously published method assessment study that a modified DNA extraction is not the reason for the contradictory findings and does not affect the specificity of the method. We also discuss the procedures recently proposed by the method developers for interpreting PCR results with high Cq values.

  • Open Access

    Food allergen analysis: Considerations for establishing a reference measurement system to implement EU legislation

    by Elena Cubero-Leon, Hendrik Emons, Gavin O'COnnor, Jørgen Nørgaard, Piotr Robouch


  • Open Access

    Food Allergen Analysis: Considerations for Establishing a Reference Measurement System to Implement EU Legislation

    by Elena Cubero-Leon, Hendrik Emons, Gavin O'COnnor, Jørgen Nørgaard, Piotr Robouch

    In order to compare food allergen measurement results, food allergen analysis has to provide measurement results for a common measurand, relevant for risk assessments, when using different measurement principles or procedures.This manuscript presents how this could be achieved by introducing the concept of a reference measurement system for food allergens.A prominent role for making measurement results metrologically traceable to the same reference is played by properly designed Reference Measurement Procedures. Additional anchor points are necessary for the practical realisation of a traceability chain, in particular reference materials for calibration.The metrological traceability and calibration hierarchy concept for food allergen measurements are illustrated. The general concept described here could also be applied for other food allergens. However, further research is needed to establish a conversion between the measured quantity and the measurand expressed as “mass fraction of total food ingredient protein in the food commodity”.

  • Open Access

    Assessment of the Real-Time PCR Method Claiming to be Specific for Detection and Quantification of the First Commercialised Genome-Edited Plant

    by Christopher Weidner, Sophia Edelmann, Dominik Moor, Kathrin Lieske, Christian Savini, Sara Jacchia, Maria Grazia Sacco, Marco Mazzara, Jörn Lämke, Kolja Neil Eckermann, et al.

    A real-time PCR method was recently published with a claim to be specific for the detection and identification of some genome-edited oilseed rape (OSR) lines commercialised in North America. The method was designed to detect a single base mutation in the AHAS1C gene, which confers herbicide tolerance. The authors claim that the method is event-specific for the genome-edited OSR line 5715 and fulfils all requirements for GMO analytical methods according to EU regulations. We have thoroughly assessed the method in relation to the minimum performance requirements (MPR) established by the European Network of GMO Laboratories (ENGL). The method was found to be sufficiently sensitive and robust when tested with pure genomic DNA of the OSR line 40 K. However, our results show that the method is not event-specific and detects also OSR lines carrying the same point mutation caused by somaclonal variation. Moreover, impaired robustness was observed using non-modified genomic DNA at the amount specified in the original protocol. Significant non-specific PCR amplifications with PCR products as non-target template DNA and with genomic DNA from numerous OSR varieties as well as from wild radish were found by three ISO/IEC 17025 accredited reference laboratories in tests using different master mixes and PCR cycler models. The assessment shows that the method does not meet the MPR for qualitative PCR methods and therefore is not fit-for-purpose for official controls of genetically modified products in the EU. Suggestions are provided for conditions under which analytical methods for genome-edited organisms should be validated.


  • Open Access

    Expression of GM content in mass fraction from digital PCR data

    by Philippe Corbisier, Gerhard Buttinger, Cristian Savini, Maria Grazia Sacco, Francesco Gatto, Hendrik Emons


  • Open Access

    Determination of Alternaria Toxins in Tomato, Wheat, and Sunflower Seeds by SPE and LC-MS/MS—A Method Validation Through a Collaborative Trial

    by Carlos Gonçalves, Ádam Tölgyesi, Katrien Bouten, Piotr Robouch, Hendrik Emons, Joerg Stroka

    Alternaria toxins are ubiquitous contaminants in highly consumed food products. Therefore, they are candidates to be regulated by EU legislation. In this context, the availability of reliable analytical methods is a keystone both for protecting the health of citizens and smooth functioning of the European market. This paper describes an advanced LC-MS/MS method based on isotope dilution quantification suitable for the determination of altenuene, alternariol, alternariol monomethyl ether, tenuazonic acid, and tentoxin in tomato puree, wheat, and sunflower seeds. The method has been validated in an interlaboratory study that included the analysis of both spiked and naturally contaminated food commodities. Twenty-three participants contributed with analytical data. The average recoveries and relative standard deviations for repeatability and reproducibility obtained across the tested matrixes were: 97, 8.0, and 23%, for altenuene, respectively; 95, 9.2, and 17% for alternariol, respectively; 98, 6.4, and 13% for alternariol monomethyl ether, respectively; 97, 4.2, and 9.3% for tenuazonic acid, respectively; and 102, 5.6, and 15% for tentoxin, respectively. The method enabled the determination of all tested Alternaria toxins close to or below 1 µg/kg. Overall, the method showed a satisfactory trueness and precision, complying with the requirements for the monitoring of mycotoxins in food in the EU. It is currently under evaluation by the European Committee for Standardization for adoption as a standard method. Isotope dilution mass spectrometry method for the determination of Alternaria toxins in food.


  • Open Access

    A reference method for determining the total allergenic protein content in a processed food: the case of milk in cookies as proof of concept

    by Maria José Martinez-Esteso, Gavin O’cOnnor, Jørgen Nørgaard, Andreas Breidbach, Marcel Brohée, Elena Cubero-Leon, Chiara Nitride, Piotr Robouch, Hendrik Emons

    The establishment of a reference method for the determination of the allergen protein content in a processed food material has been explored. An analytical approach was developed to enable the comparability of food allergen measurement results expressed in a decision-relevant manner. A proof of concept is here presented, resulting in quantity values for the common measurand, namely ‘mass of total allergen protein per mass of food’. The quantities are determined with SI traceability to enable the comparability of reported results. A method for the quantification of total milk protein content in an incurred baked food at a concentration level clinically relevant is presented. The strategy on how to obtain the final analytical result is outlined. Challenges associated with this method are discussed, in particular the optimal extraction of the marker proteins, the complete digestion and release of the peptides in an equimolar fashion, the use of conversion factors to translate the amount of measured proteins into total milk protein and the estimation of the uncertainty contributions as well as of the combined uncertainty of the final result. The implementation of such a reference method for the determination of the total allergen content in a processed food is an important step, which will provide comparable measurement data of relevance to risk assessors.


  • Open Access

    Isolation, Characterization and Structural Elucidation of Polybutylene Terephthalate Cyclic Oligomers and Purity Assessment Using a 1H qNMR Method

    by Emmanouil D. Tsochatzis, Joao Alberto Lopes, Margaret V. Holland, Fabiano Reniero, Hendrik Emons, Claude Guillou

    The use of polybutylene terephthalate (PBT) as a food contact material is increasing over the last years. Typical contaminations in the final PBT product include its cyclic oligomers, which are allowed as additives in food contact plastics according to Regulation (EU) No. 10/2011. Their investigation is currently limited by the lack of analytical standards and physical-chemical information. Therefore, four PBT cyclic oligomers have been isolated and purified from a PBT raw material with an automated preparative HPLC-DAD system. Comprehensive characterization of the compounds was performed using Ultra-High Performance Liquid Chromatography (UHPLC) with high resolution time-of-flight mass spectrometry, Fourier-Transform Infrared spectroscopy (FTIR), Differential Scanning Calorimetry (DSC) and Nuclear Magnetic Resonance (NMR) spectroscopy. The purity of each oligomer was assessed using a 1H qNMR method and ranged from 96.1% to 97.0% for PBT tetramer and trimer respectively. The availability of pure and well characterized PBT cyclic oligomer standards will facilitate future studies of release from plastic food packaging materials.