Philippe Lefere
Research Subjects
Philippe Lefere has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Stefaan Gryspeerdt
6 shared publicationsMarc Baekelandt
3 shared publicationsS. Gryspeerdt
Roeselare – Belgique
3 shared publicationsJef Dewyspelaere
Stedelijk Ziekenhuis
2 shared publications- Abraham H. Dachman
The University of Chicago
1 shared publication António Rodrigues
1 shared publication
Latest Publications
- Open Access
- 14 June 2013
- Published by Springer Nature in Insights into Imaging
- Vol. 4 (4) , 491-497
Comparison of the diagnostic performance of CT colonography interpreted by radiologists and radiographers
Objective To compare computed tomographic colonography (CTC) performance of four trained radiographers with the CTC performance of two experienced radiologists. Methods Four radiographers and two radiologists interpreted 87 cases with 40 polyps ≥6 mm. Sensitivity, specificity, and positive predictive value (PPV) were assessed on a per-patient basis. On a per-polyp basis, sensitivity was calculated according to the respective size categories (polyps ≥6 mm as well as polyps ≥10 mm). Results Overall per-patient sensitivity for polyps ≥6 mm was 76.2 % (95 % CI 61.4–91.0) and 76.2 % (95 % CI 61.7–90.6), for the radiographers and radiologists, respectively. Overall per-patient specificity for polyps ≥6 mm were 81.4 % (95 % CI 73.7–89.2) and 81.1 % (95 % CI 73.8–88.3) for the radiographers and the radiologists, respectively. For the radiographers, overall per-polyp sensitivity was 60.3 % (95 % CI 50.3–70.3) and 60.7 % (95 % CI 42.2–79.2) for polyps ≥6 mm and ≥10 mm, respectively. For the radiologists, overall per polyp sensitivity was 59.2 % (95 % CI 46.4–72.0) and 69.0 % (95 % CI 48.1–89.6) for polyps ≥6 mm and ≥10 mm, respectively. Conclusion Radiographers with training in CT colonographic evaluation achieved sensitivity and specificity in polyp detection comparable with that of experienced radiologists. Main messages • The diagnostic accuracy of trained radiographers was comparable to that of experienced radiologists. • The use of radiographers in reading CTC examinations is acceptable, however radiologists would still be necessary for the evaluation of extracolonic findings. • Skilled non-radiologists may play a vital role as a second reader of intraluminal findings or by performing quality control of examinations before patient dismissal.
- 14 June 2013
- Published by Springer Nature in Insights into Imaging
- Vol. 4 (4) , 491-497
Open AccessComparison of the diagnostic performance of CT colonography interpreted by radiologists and radiographers
Objective To compare computed tomographic colonography (CTC) performance of four trained radiographers with the CTC performance of two experienced radiologists. Methods Four radiographers and two radiologists interpreted 87 cases with 40 polyps ≥6 mm. Sensitivity, specificity, and positive predictive value (PPV) were assessed on a per-patient basis. On a per-polyp basis, sensitivity was calculated according to the respective size categories (polyps ≥6 mm as well as polyps ≥10 mm). Results Overall per-patient sensitivity for polyps ≥6 mm was 76.2 % (95 % CI 61.4–91.0) and 76.2 % (95 % CI 61.7–90.6), for the radiographers and radiologists, respectively. Overall per-patient specificity for polyps ≥6 mm were 81.4 % (95 % CI 73.7–89.2) and 81.1 % (95 % CI 73.8–88.3) for the radiographers and the radiologists, respectively. For the radiographers, overall per-polyp sensitivity was 60.3 % (95 % CI 50.3–70.3) and 60.7 % (95 % CI 42.2–79.2) for polyps ≥6 mm and ≥10 mm, respectively. For the radiologists, overall per polyp sensitivity was 59.2 % (95 % CI 46.4–72.0) and 69.0 % (95 % CI 48.1–89.6) for polyps ≥6 mm and ≥10 mm, respectively. Conclusion Radiographers with training in CT colonographic evaluation achieved sensitivity and specificity in polyp detection comparable with that of experienced radiologists. Main messages • The diagnostic accuracy of trained radiographers was comparable to that of experienced radiologists. • The use of radiographers in reading CTC examinations is acceptable, however radiologists would still be necessary for the evaluation of extracolonic findings. • Skilled non-radiologists may play a vital role as a second reader of intraluminal findings or by performing quality control of examinations before patient dismissal.
- 1 June 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 82 (6) , e262-e267
Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer
- 1 June 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 82 (6) , e262-e267
Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer
- 11 February 2013
- Published by Springer Nature
- p. 41-57
Pitfalls in Imaging
- 31 October 2009
- Published by Elsevier in Journal de Radiologie
- Vol. 90 (10) , 1248
Coloscopie virtuelle sur station siemens
- 31 October 2009
- Published by Elsevier in Journal de Radiologie
- Vol. 90 (10) , 1248
Coloscopie virtuelle sur station siemens
- 31 October 2008
- Published by Elsevier in Journal de Radiologie
- Vol. 89 (10) , 1244
Depistage du cancer colorectal par coloscopie virtuelle : les problemes a resoudre
- 31 October 2008
- Published by Elsevier in Journal de Radiologie
- Vol. 89 (10) , 1244
Depistage du cancer colorectal par coloscopie virtuelle : les problemes a resoudre
- 31 October 2008
- Published by Elsevier in Journal de Radiologie
- Vol. 89 (10) , 1248
Coloscopie virtuelle : tout CE que vous voulez savoir
- 31 October 2008
- Published by Elsevier in Journal de Radiologie
- Vol. 89 (10) , 1248
Coloscopie virtuelle : tout CE que vous voulez savoir
- 31 October 2008
- Published by Elsevier in Journal de Radiologie
- Vol. 89 (10) , 1213
Coloscopie virtuelle sur station siemens
- 31 October 2008
- Published by Elsevier in Journal de Radiologie
- Vol. 89 (10) , 1213
Coloscopie virtuelle sur station siemens
- 24 January 2008
- Published by Springer Nature in Der Radiologe
- Vol. 48 (2) , 126-134
CT-Kolonographie: Patientenvorbereitung und Untersuchungstechnik
- 24 January 2008
- Published by Springer Nature in Der Radiologe
- Vol. 48 (2) , 126-134
CT-Kolonographie: Patientenvorbereitung und Untersuchungstechnik
- 17 May 2007
- Published by Springer Nature in Abdominal Radiology
- Vol. 32 (5) , 541-551
Computed tomographic colonography: clinical value
Computed tomographic colonography (CTC) has the potential to reliably detect polyps in the colon. Its clinical value is accepted for several indications. The main target is screening asymptomatic people for colorectal cancer (CRC). As in large multi-centre trials controversial results were obtained, acceptance of this indication on a large scale is still pending. Agreement exists that in experienced hands screening can be performed with CTC. This emphasizes the importance of adequate and intensive training. Besides this, other problems have to be solved. A low complication profile is mandatory. Perforation rate is very low. Ultra-low dose radiation should be used. When screening large patient cohorts, CTC will need a time-efficient and cost-effective management without too many false positives and additional exploration. Can therefore a cut-off size of polyp detection safely be installed? Is the flat lesion an issue? Can extra-colonic findings be treated efficiently? A positive relationship with the gastro-enterologists will improve the act of screening. Improvements of scanning technique and software with dose reduction, improved 3D visualisation methods and CAD are steps in the good direction. Finally, optimisation of laxative-free CTC could be invaluable in the development of CTC as a screening tool for CRC.
- 17 May 2007
- Published by Springer Nature in Abdominal Radiology
- Vol. 32 (5) , 541-551
Computed tomographic colonography: clinical value
Computed tomographic colonography (CTC) has the potential to reliably detect polyps in the colon. Its clinical value is accepted for several indications. The main target is screening asymptomatic people for colorectal cancer (CRC). As in large multi-centre trials controversial results were obtained, acceptance of this indication on a large scale is still pending. Agreement exists that in experienced hands screening can be performed with CTC. This emphasizes the importance of adequate and intensive training. Besides this, other problems have to be solved. A low complication profile is mandatory. Perforation rate is very low. Ultra-low dose radiation should be used. When screening large patient cohorts, CTC will need a time-efficient and cost-effective management without too many false positives and additional exploration. Can therefore a cut-off size of polyp detection safely be installed? Is the flat lesion an issue? Can extra-colonic findings be treated efficiently? A positive relationship with the gastro-enterologists will improve the act of screening. Improvements of scanning technique and software with dose reduction, improved 3D visualisation methods and CAD are steps in the good direction. Finally, optimisation of laxative-free CTC could be invaluable in the development of CTC as a screening tool for CRC.
- 31 May 2006
- Published by S. Karger AG in Oncology Research and Treatment
- Vol. 29 (6) , 281-286
Virtual Colonoscopy: An Overview
Virtual colonoscopy is emerging as a technique for the detection of tumor lesions in the colon. Being a patient-friendly examination, virtual colonoscopy could play an important role in colorectal cancer screening. This article reviews the current state of the art of virtual colonoscopy with future developments and issues to be resolved.
- 31 May 2006
- Published by S. Karger AG in Oncology Research and Treatment
- Vol. 29 (6) , 281-286
Virtual Colonoscopy: An Overview
Virtual colonoscopy is emerging as a technique for the detection of tumor lesions in the colon. Being a patient-friendly examination, virtual colonoscopy could play an important role in colorectal cancer screening. This article reviews the current state of the art of virtual colonoscopy with future developments and issues to be resolved.