TYTakanori Yamazaki

Takanori Yamazaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takanori Yamazaki has a total of 63 co-authors. Here are the top co-authors by number of shared publications:

  • Daiju Fukuda

    Department of Cardiovascular Medicine Osaka Metropolitan University Graduate School of Medicine Osaka Japan

    11 shared publications
  • Yasuhiro Izumiya

    Osaka Metropolitan Univ, Grad Sch Med, Dept Cardiovasc Med, 1-4-3 Asahimachi Abenoku, Osaka 5458585, Japan

    7 shared publications
  • Hisako Yoshida

    Department of Medical Statistics Osaka Metropolitan University Graduate School of Medicine Osaka Japan

    4 shared publications
  • Kenichiro Otsuka

    Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan

    4 shared publications
  • Takenobu Shimada

    Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine

    4 shared publications
  • Tomohiro Yamaguchi

    Department of Cardiovascular Medicine Osaka Metropolitan University Graduate School of Medicine Osaka Japan

    4 shared publications

Latest Publications

  • Open Access

    Polarimetric Characterization of CCTA-Defined High-Risk Coronary Plaques: Linking Morphology to Fibrous Matrix Organization and Lipid Burden

    by Naoki Fujisawa, Kenichiro Otsuka, Georgia Lynne Jones, Martin Villiger, Kazuya Sugioka, Hiroki Yamaura, Kotaro Matsumoto, Akihiro Okamoto, Tomohiro Yamaguchi, Shunsuke Kagawa, et al.

    BACKGROUND: High-risk plaque (HRP) features on coronary computed tomography angiography (CCTA) predict future coronary events, yet the microstructural substrate underlying these radiological signatures remains largely unknown. Polarization-sensitive (PS) optical frequency domain imaging (OFDI) quantifies tissue birefringence and depolarization-derived lipid core burden index (LCBI) in vivo. We aimed to investigate the relationship between PS-OFDI–derived polarimetric signals and CCTA-defined HRP features. METHODS: We retrospectively identified 43 patients from a prospective registry of intracoronary polarimetry with PS-OFDI who had undergone CCTA before hospitalization and subsequently underwent OFDI-guided percutaneous coronary intervention. A total of 70 coronary segments were analyzed. HRP was defined as the presence of ≥2 established CCTA features: positive remodeling, low-attenuation plaque, napkin-ring sign, or spotty calcification. Conventional OFDI metrics and PS-OFDI-derived birefringence and depolarization-derived maximum 4-mm LCBI were evaluated in relation to CCTA-defined HRP. Segment-level comparisons accounted for within-patient clustering, and correlation and discrimination analyses incorporated patient-level bootstrap resampling. RESULTS: Among the 70 analyzed segments, 28 (40%) exhibited CCTA-defined HRP. HRP segments showed lower birefringence and higher depolarization-derived maximum 4-mm LCBI than non-HRP segments (both P <0.001). Birefringence was inversely correlated with low-attenuation plaque volume (ρ=−0.350 [95% CI, −0.543 to −0.131]), whereas depolarization-derived maximum 4-mm LCBI correlated with maximum lipid arc (ρ=0.480 [95% CI, 0.277–0.635]), lipid length (ρ=0.463 [95% CI, 0.199–0.654]), and minimum fibrous cap thickness (ρ=−0.466 [95% CI, −0.661 to −0.212]). Adding birefringence to conventional OFDI maximum lipid arc provided exploratory evidence of incremental discrimination for CCTA-defined HRP: apparent area under the curve increased from 0.673 to 0.853 (Δ area under the curve, 0.180 [95% CI, 0.049−0.370]), with the corresponding optimism-corrected area under the curves of 0.672 and 0.840. CONCLUSIONS: PS-OFDI-derived metrics were associated with CCTA-defined HRP features and conventional OFDI lipid parameters. Reduced birefringence in HRP lesions suggests altered collagen organization as a potential microstructural substrate underlying adverse plaque morphology identified by CCTA.


  • Electrocardiographic Characteristics Associated With Lead Position Variations in Left Bundle Branch Area Pacing

    by Naoki Matsumoto, Kenji Shimeno, Yumi Kashima, Yusuke Kure, Masanori Matsuo, Yuya Sakamoto, Takanori Yamazaki, Yoshiki Matsumura, Yukio Abe, Daiju Fukuda

    Background: Physiology‐based electrocardiographic (ECG) criteria are used to assess left bundle branch area pacing (LBBAP), but the impact of lead implantation site on ECG parameters remains unclear. Methods: We analyzed 212 patients who underwent successful LBBAP and classified them into high septum (HS, n = 49), mid septum (MS, n = 119), and low septum (LS, n = 44) groups according to the polarity of leads II and III. ECG parameters, including QRS morphology in lead V1, stimulus‐to‐R‐wave peak times in V6 and V1 (sV6RWPT, sV1RWPT), and the V6–V1 interpeak interval, were compared. The proportions meeting proposed physiology‐based ECG criteria for left bundle branch (LBB) capture were also evaluated. Results: The LS group demonstrated the highest prevalence of dominant R waves in V1 (qR: 38.6%, R: 4.5%, p < 0.01). It had a shorter sV6RWPT than the MS group (59 ± 9 ms, p = 0.011), with no significant difference compared with the HS group. It also demonstrated a longer sV1RWPT (105 ± 11 ms, p = 0.023) and V6–V1 interpeak interval (46 ± 10 ms, p < 0.01). Although no significant differences were observed among the three groups regarding output‐dependent QRS transition or LBB potential, the LS group more frequently met the V6–V1 interpeak interval criterion (>44 ms, 86%, p < 0.01). Conclusions: In LBBAP, low septal lead placement was associated with prominent R waves in V1, shorter sV6RWPT versus the MS group, and longer V6–V1 interpeak intervals, highlighting the importance of implantation site when interpreting ECG findings.

  • Open Access

    Beyond Strut Coverage ― Toward Functional Endothelization After Drug-Eluting Stent Implantation ―

    by Takanori Yamazaki, Keisuke Kojima

    Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.

  • Dual Device Fragment Retrieval Using Two‐Wire and Snare Technique During Percutaneous Coronary Intervention: A Case of Guide Extension Tip and Balloon Shaft Separation

    by Akihiro Okamoto, Takanori Yamazaki, Tomohiro Yamaguchi, Daiju Fukuda

    Device‐related complications during percutaneous coronary intervention (PCI), such as catheter or balloon shaft separation, are uncommon but potentially life‐threatening. Effective retrieval techniques are crucial to avoid surgical intervention. We report a rare case of simultaneous separation of a guide extension catheter tip and balloon shaft, successfully managed using a two‐wire and snare technique. A 58‐year‐old man with a history of familial hypercholesterolemia underwent PCI for in‐stent restenosis in the mid right coronary artery (RCA), previously treated with a sirolimus‐eluting stent. After successful lesion preparation using a scoring balloon and drug‐coated balloon via a 6‐Fr guide extension catheter, the extension catheter became stuck in a tortuous segment. Attempted withdrawal resulted in distal tip separation. A 2.0‐mm balloon was deployed inside the tip for trapping, but during retrieval the balloon shaft itself fractured. To retrieve both fragments, a second guidewire was advanced outside the separated tip with the aid of a microcatheter, followed by deployment of a Goose Neck snare. The snare successfully grasped the initial guidewire, enabling the en bloc retrieval of both the guide extension tip and the broken balloon shaft. No complications occurred, and final angiography confirmed optimal flow. This case illustrates a practical and effective two‐wire plus snare technique for managing simultaneous device fragment separation during PCI. Familiarity with bailout strategies such as this may help avoid surgical retrieval or further complications in similar settings.


  • Open Access

    Plaque morphological changes after drug-coated balloon angioplasty according to underlying plaque components

    by Naoki Fujisawa, Takenobu Shimada, Kenichiro Otsuka, Takanori Yamazaki, Daiju Fukuda


  • Successful revascularization of coronary occlusion due to lotus root‐like plaques by IVUS‐based real‐time three‐dimensional wiring using the tip detection method in a patient with cardiac arrest

    by Akihiro Okamoto, Tomohiro Yamaguchi, Takanori Yamazaki, Daiju Fukuda

    A 32‐year‐old man, who was treated for T‐cell lymphoma, presented in cardiac arrest. He had been treated for heart failure with reduced ejection fraction. Veno‐arterial extracorporeal membrane oxygenation was initiated immediately. We diagnosed him as non‐ST elevated myocardial infarction. Coronary angiography demonstrated the occlusion of the trifurcation in the proximal left anterior descending artery (LAD). We failed to advance the first guidewire into the distal LAD by angio‐based conventional wiring. Intravascular ultrasonography (IVUS) of the proximal diagonal branch revealed two diaphragms separating the distal lumen without connection, which looks like lotus root‐like appearance. We quickly penetrated the plaque using IVUS‐based real‐time 3D wiring using the tip detection method. The contrast injection via the microcatheter showed the distal diagonal branch (D2). After the balloon dilation in D2, IVUS image revealed a torn plaque between D2 and the distal LAD. Subsequently we advanced the guidewire to the distal LAD using IVUS‐based real‐time 3D wiring using the tip detection method through the tear of the plaque. Finally, we successfully performed the revascularization of LAD in a preferable procedure time. The patient recovered well and was discharged 39 days after cardiac arrest. This case highlights the efficacy of IVUS‐based real‐time 3D wiring using the tip detection method even in the emergent and challenging situation.

  • Utility and optimal dose of nicorandil for physiological assessment of the femoropopliteal artery

    by Naoki Yoshioka, Takenobu Shimada, Yoshihiro Iwasaki, Hisako Yoshida, Kenichiro Otsuka, Takanori Yamazaki, Yasuhiro Morita, Shigeru Nakamura, Daiju Fukuda, Itsuro Morishima

    Background: Nicorandil is widely used as a vasodilator for the physiological assessment of coronary arteries because of its usefulness and safety; however, there are no data on its use in peripheral arteries.Aims: To identify the utility of nicorandil and its appropriate dose for the physiological assessment on the femoropopliteal artery.Methods: We retrospectively enrolled patients from three institutes in which physiological assessment was carried out with various doses of nicorandil before treatment. Twenty‐four femoropopliteal artery stenotic lesions from 22 patients were included. The nicorandil doses used were 2, 4, and 6 mg. Twenty‐two lesions were also assessed using 30 mg of papaverine. The pressure gradient (PG) and peripheral fractional flow reserve (pFFR) were calculated based on the mean and systolic pressure levels. We examined the correlation of each parameter with the peak systolic velocity ratio (PSVR) based on the duplex ultrasound images using Spearman's rank correlation coefficient. Systemic blood pressure was assessed for safety.Results: The correlations were higher for mean pressure‐based parameters than for systolic pressure‐based parameters. As the nicorandil dose increased, the correlations among PG, pFFR, and PSVR also increased (mean pressure‐based PG: 2 mg, r = 0.360; 4 mg, r = 0.498; 6 mg, r = 0.694, mean pressure‐based pFFR: 2 mg, r = −0.479; 4 mg, r = −0.469; 6 mg, r = −0.641). The blood pressure after the administration of 6 mg of nicorandil was low, and the median systemic mean pressure was 65 mmHg.Conclusion: A 4 mg dose of nicorandil is effective and safe for the mean pressure‐based physiological assessment of lesions in the femoropopliteal artery.


  • Open Access

    Correction: Tissue responses to everolimus-eluting stents implanted in severely calcified lesions following atherectomy

    by Tomohiro Yamaguchi, Takanori Yamazaki, Hisako Yoshida, Kotaro Matsumoto, Ryosuke Yahiro, Kazuhiro Nakao, Yusuke Kure, Tsukasa Okai, Takenobu Shimada, Kenichiro Otsuka, et al.

  • Open Access

    Tissue responses to everolimus-eluting stents implanted in severely calcified lesions following atherectomy

    by Tomohiro Yamaguchi, Takanori Yamazaki, Hisako Yoshida, Kotaro Matsumoto, Ryosuke Yahiro, Kazuhiro Nakao, Yusuke Kure, Tsukasa Okai, Takenobu Shimada, Kenichiro Otsuka, et al.

    Histopathological examination has revealed that stents on severely calcified plaques were associated with delayed vascular healing. Although atherectomy devices can increase the number of malapposed struts, tissue responses to implanted drug eluting stents in atherectomy patients remain largely unknown. This retrospective observational study included 30 patients who underwent atherectomy and everolimus-eluting stent (EES) deployment for severely calcified coronary lesions (biodegradable polymer EES (BP-EES), n = 15; durable polymer EES (DP-EES), n = 15). Optical coherence tomography was carried out at baseline and follow-up, and struts with acute stent malapposition (ASM) were categorized as struts on modified calcium (mod-Ca), non-modified calcium (non-mod-Ca), or non-calcium (non-Ca). Adequate vascular healing, defined as ASM resolution with neointimal coverage, was compared between the BP-EES and DP-EES groups. Multivariate linear regression analysis using a generalized estimated equation revealed that BP-EES use was associated with significantly better adequate vascular healing compared with DP-EES (odds ratio [OR]: 3.691, 95% confidence interval [CI] 1.175–11.592, P = 0.025). adequate vascular healing was associated with the underlying plaque morphology (mod-Ca vs non-mod-Ca: OR 2.833, 95% CI 1.491–5.384, P = 0.001; non-Ca vs non-mod-Ca: OR 1.248, 95% CI 0.440–3.543, P = 0.677). This study demonstrates that drug-eluting stent selection and calcium modification are possible factors affecting vascular healing of malapposed struts in severely calcified lesions. Graphical Abstract