Takanori Yamazaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takanori Yamazaki has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Daiju Fukuda
Department of Cardiovascular Medicine Osaka Metropolitan University Graduate School of Medicine Osaka Japan
11 shared publicationsYasuhiro Izumiya
Osaka Metropolitan Univ, Grad Sch Med, Dept Cardiovasc Med, 1-4-3 Asahimachi Abenoku, Osaka 5458585, Japan
7 shared publicationsHisako Yoshida
Department of Medical Statistics Osaka Metropolitan University Graduate School of Medicine Osaka Japan
4 shared publicationsKenichiro Otsuka
Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
4 shared publications- Takenobu Shimada
Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine
4 shared publications - Tomohiro Yamaguchi
Department of Cardiovascular Medicine Osaka Metropolitan University Graduate School of Medicine Osaka Japan
4 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 19 (11)
Polarimetric Characterization of CCTA-Defined High-Risk Coronary Plaques: Linking Morphology to Fibrous Matrix Organization and Lipid Burden
BACKGROUND: High-risk plaque (HRP) features on coronary computed tomography angiography (CCTA) predict future coronary events, yet the microstructural substrate underlying these radiological signatures remains largely unknown. Polarization-sensitive (PS) optical frequency domain imaging (OFDI) quantifies tissue birefringence and depolarization-derived lipid core burden index (LCBI) in vivo. We aimed to investigate the relationship between PS-OFDI–derived polarimetric signals and CCTA-defined HRP features. METHODS: We retrospectively identified 43 patients from a prospective registry of intracoronary polarimetry with PS-OFDI who had undergone CCTA before hospitalization and subsequently underwent OFDI-guided percutaneous coronary intervention. A total of 70 coronary segments were analyzed. HRP was defined as the presence of ≥2 established CCTA features: positive remodeling, low-attenuation plaque, napkin-ring sign, or spotty calcification. Conventional OFDI metrics and PS-OFDI-derived birefringence and depolarization-derived maximum 4-mm LCBI were evaluated in relation to CCTA-defined HRP. Segment-level comparisons accounted for within-patient clustering, and correlation and discrimination analyses incorporated patient-level bootstrap resampling. RESULTS: Among the 70 analyzed segments, 28 (40%) exhibited CCTA-defined HRP. HRP segments showed lower birefringence and higher depolarization-derived maximum 4-mm LCBI than non-HRP segments (both P <0.001). Birefringence was inversely correlated with low-attenuation plaque volume (ρ=−0.350 [95% CI, −0.543 to −0.131]), whereas depolarization-derived maximum 4-mm LCBI correlated with maximum lipid arc (ρ=0.480 [95% CI, 0.277–0.635]), lipid length (ρ=0.463 [95% CI, 0.199–0.654]), and minimum fibrous cap thickness (ρ=−0.466 [95% CI, −0.661 to −0.212]). Adding birefringence to conventional OFDI maximum lipid arc provided exploratory evidence of incremental discrimination for CCTA-defined HRP: apparent area under the curve increased from 0.673 to 0.853 (Δ area under the curve, 0.180 [95% CI, 0.049−0.370]), with the corresponding optimism-corrected area under the curves of 0.672 and 0.840. CONCLUSIONS: PS-OFDI-derived metrics were associated with CCTA-defined HRP features and conventional OFDI lipid parameters. Reduced birefringence in HRP lesions suggests altered collagen organization as a potential microstructural substrate underlying adverse plaque morphology identified by CCTA.
- 1 November 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 19 (11)
Open AccessPolarimetric Characterization of CCTA-Defined High-Risk Coronary Plaques: Linking Morphology to Fibrous Matrix Organization and Lipid Burden
BACKGROUND: High-risk plaque (HRP) features on coronary computed tomography angiography (CCTA) predict future coronary events, yet the microstructural substrate underlying these radiological signatures remains largely unknown. Polarization-sensitive (PS) optical frequency domain imaging (OFDI) quantifies tissue birefringence and depolarization-derived lipid core burden index (LCBI) in vivo. We aimed to investigate the relationship between PS-OFDI–derived polarimetric signals and CCTA-defined HRP features. METHODS: We retrospectively identified 43 patients from a prospective registry of intracoronary polarimetry with PS-OFDI who had undergone CCTA before hospitalization and subsequently underwent OFDI-guided percutaneous coronary intervention. A total of 70 coronary segments were analyzed. HRP was defined as the presence of ≥2 established CCTA features: positive remodeling, low-attenuation plaque, napkin-ring sign, or spotty calcification. Conventional OFDI metrics and PS-OFDI-derived birefringence and depolarization-derived maximum 4-mm LCBI were evaluated in relation to CCTA-defined HRP. Segment-level comparisons accounted for within-patient clustering, and correlation and discrimination analyses incorporated patient-level bootstrap resampling. RESULTS: Among the 70 analyzed segments, 28 (40%) exhibited CCTA-defined HRP. HRP segments showed lower birefringence and higher depolarization-derived maximum 4-mm LCBI than non-HRP segments (both P <0.001). Birefringence was inversely correlated with low-attenuation plaque volume (ρ=−0.350 [95% CI, −0.543 to −0.131]), whereas depolarization-derived maximum 4-mm LCBI correlated with maximum lipid arc (ρ=0.480 [95% CI, 0.277–0.635]), lipid length (ρ=0.463 [95% CI, 0.199–0.654]), and minimum fibrous cap thickness (ρ=−0.466 [95% CI, −0.661 to −0.212]). Adding birefringence to conventional OFDI maximum lipid arc provided exploratory evidence of incremental discrimination for CCTA-defined HRP: apparent area under the curve increased from 0.673 to 0.853 (Δ area under the curve, 0.180 [95% CI, 0.049−0.370]), with the corresponding optimism-corrected area under the curves of 0.672 and 0.840. CONCLUSIONS: PS-OFDI-derived metrics were associated with CCTA-defined HRP features and conventional OFDI lipid parameters. Reduced birefringence in HRP lesions suggests altered collagen organization as a potential microstructural substrate underlying adverse plaque morphology identified by CCTA.
- 28 May 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
Electrocardiographic Characteristics Associated With Lead Position Variations in Left Bundle Branch Area Pacing
Background: Physiology‐based electrocardiographic (ECG) criteria are used to assess left bundle branch area pacing (LBBAP), but the impact of lead implantation site on ECG parameters remains unclear. Methods: We analyzed 212 patients who underwent successful LBBAP and classified them into high septum (HS, n = 49), mid septum (MS, n = 119), and low septum (LS, n = 44) groups according to the polarity of leads II and III. ECG parameters, including QRS morphology in lead V1, stimulus‐to‐R‐wave peak times in V6 and V1 (sV6RWPT, sV1RWPT), and the V6–V1 interpeak interval, were compared. The proportions meeting proposed physiology‐based ECG criteria for left bundle branch (LBB) capture were also evaluated. Results: The LS group demonstrated the highest prevalence of dominant R waves in V1 (qR: 38.6%, R: 4.5%, p < 0.01). It had a shorter sV6RWPT than the MS group (59 ± 9 ms, p = 0.011), with no significant difference compared with the HS group. It also demonstrated a longer sV1RWPT (105 ± 11 ms, p = 0.023) and V6–V1 interpeak interval (46 ± 10 ms, p < 0.01). Although no significant differences were observed among the three groups regarding output‐dependent QRS transition or LBB potential, the LS group more frequently met the V6–V1 interpeak interval criterion (>44 ms, 86%, p < 0.01). Conclusions: In LBBAP, low septal lead placement was associated with prominent R waves in V1, shorter sV6RWPT versus the MS group, and longer V6–V1 interpeak intervals, highlighting the importance of implantation site when interpreting ECG findings.
- 28 May 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
Electrocardiographic Characteristics Associated With Lead Position Variations in Left Bundle Branch Area Pacing
Background: Physiology‐based electrocardiographic (ECG) criteria are used to assess left bundle branch area pacing (LBBAP), but the impact of lead implantation site on ECG parameters remains unclear. Methods: We analyzed 212 patients who underwent successful LBBAP and classified them into high septum (HS, n = 49), mid septum (MS, n = 119), and low septum (LS, n = 44) groups according to the polarity of leads II and III. ECG parameters, including QRS morphology in lead V1, stimulus‐to‐R‐wave peak times in V6 and V1 (sV6RWPT, sV1RWPT), and the V6–V1 interpeak interval, were compared. The proportions meeting proposed physiology‐based ECG criteria for left bundle branch (LBB) capture were also evaluated. Results: The LS group demonstrated the highest prevalence of dominant R waves in V1 (qR: 38.6%, R: 4.5%, p < 0.01). It had a shorter sV6RWPT than the MS group (59 ± 9 ms, p = 0.011), with no significant difference compared with the HS group. It also demonstrated a longer sV1RWPT (105 ± 11 ms, p = 0.023) and V6–V1 interpeak interval (46 ± 10 ms, p < 0.01). Although no significant differences were observed among the three groups regarding output‐dependent QRS transition or LBB potential, the LS group more frequently met the V6–V1 interpeak interval criterion (>44 ms, 86%, p < 0.01). Conclusions: In LBBAP, low septal lead placement was associated with prominent R waves in V1, shorter sV6RWPT versus the MS group, and longer V6–V1 interpeak intervals, highlighting the importance of implantation site when interpreting ECG findings.
- Open Access
- 14 April 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (8) , CJ-26-0189-968
Beyond Strut Coverage ― Toward Functional Endothelization After Drug-Eluting Stent Implantation ―
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 14 April 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (8) , CJ-26-0189-968
Open AccessBeyond Strut Coverage ― Toward Functional Endothelization After Drug-Eluting Stent Implantation ―
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 26 June 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (3) , 1570-1573
Dual Device Fragment Retrieval Using Two‐Wire and Snare Technique During Percutaneous Coronary Intervention: A Case of Guide Extension Tip and Balloon Shaft Separation
Device‐related complications during percutaneous coronary intervention (PCI), such as catheter or balloon shaft separation, are uncommon but potentially life‐threatening. Effective retrieval techniques are crucial to avoid surgical intervention. We report a rare case of simultaneous separation of a guide extension catheter tip and balloon shaft, successfully managed using a two‐wire and snare technique. A 58‐year‐old man with a history of familial hypercholesterolemia underwent PCI for in‐stent restenosis in the mid right coronary artery (RCA), previously treated with a sirolimus‐eluting stent. After successful lesion preparation using a scoring balloon and drug‐coated balloon via a 6‐Fr guide extension catheter, the extension catheter became stuck in a tortuous segment. Attempted withdrawal resulted in distal tip separation. A 2.0‐mm balloon was deployed inside the tip for trapping, but during retrieval the balloon shaft itself fractured. To retrieve both fragments, a second guidewire was advanced outside the separated tip with the aid of a microcatheter, followed by deployment of a Goose Neck snare. The snare successfully grasped the initial guidewire, enabling the en bloc retrieval of both the guide extension tip and the broken balloon shaft. No complications occurred, and final angiography confirmed optimal flow. This case illustrates a practical and effective two‐wire plus snare technique for managing simultaneous device fragment separation during PCI. Familiarity with bailout strategies such as this may help avoid surgical retrieval or further complications in similar settings.
- 26 June 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (3) , 1570-1573
Dual Device Fragment Retrieval Using Two‐Wire and Snare Technique During Percutaneous Coronary Intervention: A Case of Guide Extension Tip and Balloon Shaft Separation
Device‐related complications during percutaneous coronary intervention (PCI), such as catheter or balloon shaft separation, are uncommon but potentially life‐threatening. Effective retrieval techniques are crucial to avoid surgical intervention. We report a rare case of simultaneous separation of a guide extension catheter tip and balloon shaft, successfully managed using a two‐wire and snare technique. A 58‐year‐old man with a history of familial hypercholesterolemia underwent PCI for in‐stent restenosis in the mid right coronary artery (RCA), previously treated with a sirolimus‐eluting stent. After successful lesion preparation using a scoring balloon and drug‐coated balloon via a 6‐Fr guide extension catheter, the extension catheter became stuck in a tortuous segment. Attempted withdrawal resulted in distal tip separation. A 2.0‐mm balloon was deployed inside the tip for trapping, but during retrieval the balloon shaft itself fractured. To retrieve both fragments, a second guidewire was advanced outside the separated tip with the aid of a microcatheter, followed by deployment of a Goose Neck snare. The snare successfully grasped the initial guidewire, enabling the en bloc retrieval of both the guide extension tip and the broken balloon shaft. No complications occurred, and final angiography confirmed optimal flow. This case illustrates a practical and effective two‐wire plus snare technique for managing simultaneous device fragment separation during PCI. Familiarity with bailout strategies such as this may help avoid surgical retrieval or further complications in similar settings.
- Open Access
- 23 October 2024
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (1) , 101651
Plaque morphological changes after drug-coated balloon angioplasty according to underlying plaque components
- 23 October 2024
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (1) , 101651
Open AccessPlaque morphological changes after drug-coated balloon angioplasty according to underlying plaque components
- 10 July 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 104 (2) , 252-255
Successful revascularization of coronary occlusion due to lotus root‐like plaques by IVUS‐based real‐time three‐dimensional wiring using the tip detection method in a patient with cardiac arrest
A 32‐year‐old man, who was treated for T‐cell lymphoma, presented in cardiac arrest. He had been treated for heart failure with reduced ejection fraction. Veno‐arterial extracorporeal membrane oxygenation was initiated immediately. We diagnosed him as non‐ST elevated myocardial infarction. Coronary angiography demonstrated the occlusion of the trifurcation in the proximal left anterior descending artery (LAD). We failed to advance the first guidewire into the distal LAD by angio‐based conventional wiring. Intravascular ultrasonography (IVUS) of the proximal diagonal branch revealed two diaphragms separating the distal lumen without connection, which looks like lotus root‐like appearance. We quickly penetrated the plaque using IVUS‐based real‐time 3D wiring using the tip detection method. The contrast injection via the microcatheter showed the distal diagonal branch (D2). After the balloon dilation in D2, IVUS image revealed a torn plaque between D2 and the distal LAD. Subsequently we advanced the guidewire to the distal LAD using IVUS‐based real‐time 3D wiring using the tip detection method through the tear of the plaque. Finally, we successfully performed the revascularization of LAD in a preferable procedure time. The patient recovered well and was discharged 39 days after cardiac arrest. This case highlights the efficacy of IVUS‐based real‐time 3D wiring using the tip detection method even in the emergent and challenging situation.
- 10 July 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 104 (2) , 252-255
Successful revascularization of coronary occlusion due to lotus root‐like plaques by IVUS‐based real‐time three‐dimensional wiring using the tip detection method in a patient with cardiac arrest
A 32‐year‐old man, who was treated for T‐cell lymphoma, presented in cardiac arrest. He had been treated for heart failure with reduced ejection fraction. Veno‐arterial extracorporeal membrane oxygenation was initiated immediately. We diagnosed him as non‐ST elevated myocardial infarction. Coronary angiography demonstrated the occlusion of the trifurcation in the proximal left anterior descending artery (LAD). We failed to advance the first guidewire into the distal LAD by angio‐based conventional wiring. Intravascular ultrasonography (IVUS) of the proximal diagonal branch revealed two diaphragms separating the distal lumen without connection, which looks like lotus root‐like appearance. We quickly penetrated the plaque using IVUS‐based real‐time 3D wiring using the tip detection method. The contrast injection via the microcatheter showed the distal diagonal branch (D2). After the balloon dilation in D2, IVUS image revealed a torn plaque between D2 and the distal LAD. Subsequently we advanced the guidewire to the distal LAD using IVUS‐based real‐time 3D wiring using the tip detection method through the tear of the plaque. Finally, we successfully performed the revascularization of LAD in a preferable procedure time. The patient recovered well and was discharged 39 days after cardiac arrest. This case highlights the efficacy of IVUS‐based real‐time 3D wiring using the tip detection method even in the emergent and challenging situation.
- 16 February 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 103 (4) , 670-677
Utility and optimal dose of nicorandil for physiological assessment of the femoropopliteal artery
Background: Nicorandil is widely used as a vasodilator for the physiological assessment of coronary arteries because of its usefulness and safety; however, there are no data on its use in peripheral arteries.Aims: To identify the utility of nicorandil and its appropriate dose for the physiological assessment on the femoropopliteal artery.Methods: We retrospectively enrolled patients from three institutes in which physiological assessment was carried out with various doses of nicorandil before treatment. Twenty‐four femoropopliteal artery stenotic lesions from 22 patients were included. The nicorandil doses used were 2, 4, and 6 mg. Twenty‐two lesions were also assessed using 30 mg of papaverine. The pressure gradient (PG) and peripheral fractional flow reserve (pFFR) were calculated based on the mean and systolic pressure levels. We examined the correlation of each parameter with the peak systolic velocity ratio (PSVR) based on the duplex ultrasound images using Spearman's rank correlation coefficient. Systemic blood pressure was assessed for safety.Results: The correlations were higher for mean pressure‐based parameters than for systolic pressure‐based parameters. As the nicorandil dose increased, the correlations among PG, pFFR, and PSVR also increased (mean pressure‐based PG: 2 mg, r = 0.360; 4 mg, r = 0.498; 6 mg, r = 0.694, mean pressure‐based pFFR: 2 mg, r = −0.479; 4 mg, r = −0.469; 6 mg, r = −0.641). The blood pressure after the administration of 6 mg of nicorandil was low, and the median systemic mean pressure was 65 mmHg.Conclusion: A 4 mg dose of nicorandil is effective and safe for the mean pressure‐based physiological assessment of lesions in the femoropopliteal artery.
- 16 February 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 103 (4) , 670-677
Utility and optimal dose of nicorandil for physiological assessment of the femoropopliteal artery
Background: Nicorandil is widely used as a vasodilator for the physiological assessment of coronary arteries because of its usefulness and safety; however, there are no data on its use in peripheral arteries.Aims: To identify the utility of nicorandil and its appropriate dose for the physiological assessment on the femoropopliteal artery.Methods: We retrospectively enrolled patients from three institutes in which physiological assessment was carried out with various doses of nicorandil before treatment. Twenty‐four femoropopliteal artery stenotic lesions from 22 patients were included. The nicorandil doses used were 2, 4, and 6 mg. Twenty‐two lesions were also assessed using 30 mg of papaverine. The pressure gradient (PG) and peripheral fractional flow reserve (pFFR) were calculated based on the mean and systolic pressure levels. We examined the correlation of each parameter with the peak systolic velocity ratio (PSVR) based on the duplex ultrasound images using Spearman's rank correlation coefficient. Systemic blood pressure was assessed for safety.Results: The correlations were higher for mean pressure‐based parameters than for systolic pressure‐based parameters. As the nicorandil dose increased, the correlations among PG, pFFR, and PSVR also increased (mean pressure‐based PG: 2 mg, r = 0.360; 4 mg, r = 0.498; 6 mg, r = 0.694, mean pressure‐based pFFR: 2 mg, r = −0.479; 4 mg, r = −0.469; 6 mg, r = −0.641). The blood pressure after the administration of 6 mg of nicorandil was low, and the median systemic mean pressure was 65 mmHg.Conclusion: A 4 mg dose of nicorandil is effective and safe for the mean pressure‐based physiological assessment of lesions in the femoropopliteal artery.
- Open Access
- 9 February 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 68 (1) , 133-134
Plaque Morphological Changes in Femoropopliteal Arterial Lesions Caused by Balloon Angioplasty: Analysis Through Integrated Backscatter Intravascular Ultrasound
- 9 February 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 68 (1) , 133-134
Open AccessPlaque Morphological Changes in Femoropopliteal Arterial Lesions Caused by Balloon Angioplasty: Analysis Through Integrated Backscatter Intravascular Ultrasound
- Open Access
- 8 December 2023
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (1) , 45-46
Correction: Tissue responses to everolimus-eluting stents implanted in severely calcified lesions following atherectomy
- 8 December 2023
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (1) , 45-46
Open AccessCorrection: Tissue responses to everolimus-eluting stents implanted in severely calcified lesions following atherectomy
- Open Access
- 20 October 2023
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (1) , 34-44
Tissue responses to everolimus-eluting stents implanted in severely calcified lesions following atherectomy
Histopathological examination has revealed that stents on severely calcified plaques were associated with delayed vascular healing. Although atherectomy devices can increase the number of malapposed struts, tissue responses to implanted drug eluting stents in atherectomy patients remain largely unknown. This retrospective observational study included 30 patients who underwent atherectomy and everolimus-eluting stent (EES) deployment for severely calcified coronary lesions (biodegradable polymer EES (BP-EES), n = 15; durable polymer EES (DP-EES), n = 15). Optical coherence tomography was carried out at baseline and follow-up, and struts with acute stent malapposition (ASM) were categorized as struts on modified calcium (mod-Ca), non-modified calcium (non-mod-Ca), or non-calcium (non-Ca). Adequate vascular healing, defined as ASM resolution with neointimal coverage, was compared between the BP-EES and DP-EES groups. Multivariate linear regression analysis using a generalized estimated equation revealed that BP-EES use was associated with significantly better adequate vascular healing compared with DP-EES (odds ratio [OR]: 3.691, 95% confidence interval [CI] 1.175–11.592, P = 0.025). adequate vascular healing was associated with the underlying plaque morphology (mod-Ca vs non-mod-Ca: OR 2.833, 95% CI 1.491–5.384, P = 0.001; non-Ca vs non-mod-Ca: OR 1.248, 95% CI 0.440–3.543, P = 0.677). This study demonstrates that drug-eluting stent selection and calcium modification are possible factors affecting vascular healing of malapposed struts in severely calcified lesions. Graphical Abstract
- 20 October 2023
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (1) , 34-44
Open AccessTissue responses to everolimus-eluting stents implanted in severely calcified lesions following atherectomy
Histopathological examination has revealed that stents on severely calcified plaques were associated with delayed vascular healing. Although atherectomy devices can increase the number of malapposed struts, tissue responses to implanted drug eluting stents in atherectomy patients remain largely unknown. This retrospective observational study included 30 patients who underwent atherectomy and everolimus-eluting stent (EES) deployment for severely calcified coronary lesions (biodegradable polymer EES (BP-EES), n = 15; durable polymer EES (DP-EES), n = 15). Optical coherence tomography was carried out at baseline and follow-up, and struts with acute stent malapposition (ASM) were categorized as struts on modified calcium (mod-Ca), non-modified calcium (non-mod-Ca), or non-calcium (non-Ca). Adequate vascular healing, defined as ASM resolution with neointimal coverage, was compared between the BP-EES and DP-EES groups. Multivariate linear regression analysis using a generalized estimated equation revealed that BP-EES use was associated with significantly better adequate vascular healing compared with DP-EES (odds ratio [OR]: 3.691, 95% confidence interval [CI] 1.175–11.592, P = 0.025). adequate vascular healing was associated with the underlying plaque morphology (mod-Ca vs non-mod-Ca: OR 2.833, 95% CI 1.491–5.384, P = 0.001; non-Ca vs non-mod-Ca: OR 1.248, 95% CI 0.440–3.543, P = 0.677). This study demonstrates that drug-eluting stent selection and calcium modification are possible factors affecting vascular healing of malapposed struts in severely calcified lesions. Graphical Abstract