Koldo Redondo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Koldo Redondo has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jose Julio Gutierrez
Department of Communications Engineering, University of the Basque Country, UPV/EHU, 48013 Bilbao, Spain
19 shared publications - Purificacion Saiz
Department of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Spain
19 shared publications L.A. Leturiondo
13 shared publicationsA. Lazkano
11 shared publications- Izaskun Azcarate
Group of Signal and Communications, Bilbao School of Engineering, University of the Basque Country UPV/EHU, Plaza Torres Quevedo 1, 48013 Bilbao, Spain
11 shared publications I. Azcarate
7 shared publications
Latest Publications
- Open Access
- 3 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6918
The Role of Chest Compressions on Ventilation during Advanced Cardiopulmonary Resuscitation
Background: There is growing interest in the quality of manual ventilation during cardiopulmonary resuscitation (CPR), but accurate assessment of ventilation parameters remains a challenge. Waveform capnography is currently the reference for monitoring ventilation rate in intubated patients, but fails to provide information on tidal volumes and inspiration–expiration timing. Moreover, the capnogram is often distorted when chest compressions (CCs) are performed during ventilation compromising its reliability during CPR. Our main purpose was to characterize manual ventilation during CPR and to assess how CCs may impact on ventilation quality. Methods: Retrospective analysis were performed of CPR recordings fromtwo databases of adult patients in cardiac arrest including capnogram, compression depth, and airway flow, pressure and volume signals. Using automated signal processing techniques followed by manual revision, individual ventilations were identified and ventilation parameters were measured. Oscillations on the capnogram plateau during CCs were characterized, and its correlation with compression depth and airway volume was assessed. Finally, we identified events of reversed airflow caused by CCs and their effect on volume and capnogram waveform. Results: Ventilation rates were higher than the recommended 10 breaths/min in 66.7% of the cases. Variability in ventilation rates correlated with the variability in tidal volumes and other ventilatory parameters. Oscillations caused by CCs on capnograms were of high amplitude (median above 74%) and were associated with low pseudo-volumes (median 26 mL). Correlation between the amplitude of those oscillations with either the CCs depth or the generated passive volumes was low, with correlation coefficients of −0.24 and 0.40, respectively. During inspiration and expiration, reversed airflow events caused opposed movement of gases in 80% of ventilations. Conclusions: Our study confirmed lack of adherence between measured ventilation rates and the guideline recommendations, and a substantial dispersion in manual ventilation parameters during CPR. Oscillations on the capnogram plateau caused by CCs did not correlate with compression depth or associated small tidal volumes. CCs caused reversed flow during inspiration, expiration and in the interval between ventilations, sufficient to generate volume changes and causing oscillations on capnogram. Further research is warranted to assess the impact of these findings on ventilation quality during CPR.
- 3 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6918
Open AccessThe Role of Chest Compressions on Ventilation during Advanced Cardiopulmonary Resuscitation
Background: There is growing interest in the quality of manual ventilation during cardiopulmonary resuscitation (CPR), but accurate assessment of ventilation parameters remains a challenge. Waveform capnography is currently the reference for monitoring ventilation rate in intubated patients, but fails to provide information on tidal volumes and inspiration–expiration timing. Moreover, the capnogram is often distorted when chest compressions (CCs) are performed during ventilation compromising its reliability during CPR. Our main purpose was to characterize manual ventilation during CPR and to assess how CCs may impact on ventilation quality. Methods: Retrospective analysis were performed of CPR recordings fromtwo databases of adult patients in cardiac arrest including capnogram, compression depth, and airway flow, pressure and volume signals. Using automated signal processing techniques followed by manual revision, individual ventilations were identified and ventilation parameters were measured. Oscillations on the capnogram plateau during CCs were characterized, and its correlation with compression depth and airway volume was assessed. Finally, we identified events of reversed airflow caused by CCs and their effect on volume and capnogram waveform. Results: Ventilation rates were higher than the recommended 10 breaths/min in 66.7% of the cases. Variability in ventilation rates correlated with the variability in tidal volumes and other ventilatory parameters. Oscillations caused by CCs on capnograms were of high amplitude (median above 74%) and were associated with low pseudo-volumes (median 26 mL). Correlation between the amplitude of those oscillations with either the CCs depth or the generated passive volumes was low, with correlation coefficients of −0.24 and 0.40, respectively. During inspiration and expiration, reversed airflow events caused opposed movement of gases in 80% of ventilations. Conclusions: Our study confirmed lack of adherence between measured ventilation rates and the guideline recommendations, and a substantial dispersion in manual ventilation parameters during CPR. Oscillations on the capnogram plateau caused by CCs did not correlate with compression depth or associated small tidal volumes. CCs caused reversed flow during inspiration, expiration and in the interval between ventilations, sufficient to generate volume changes and causing oscillations on capnogram. Further research is warranted to assess the impact of these findings on ventilation quality during CPR.
- Open Access
- 20 July 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 153
Influence of yaw control on flicker produced by wind turbines
- 20 July 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 153
Open AccessInfluence of yaw control on flicker produced by wind turbines
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 658-663
Improving the Detection of RVCs for a Better Assessment of Their Influence on Flicker
Rapid Voltage Changes (RVC) produce sudden illuminance changes that can generate flicker. The IEC 61 000-4-30 standard defines the procedure for the measurement of RVCs, but it does not include a metric to assess the effect of RVCs on the perception of flicker. The IEC 61 000-4-15 standard establishes the specification of a flickermeter, which assesses the effect of voltage fluctuations on flicker by calculating the flicker severity,$P_\text{st}$ , during a 10 min interval. However,$P_\text{st}$ is ineffective to adequately assess voltage variations as fast and short as RVCs. This work analyzes the main characteristics of the RVCs affecting flicker. The relationship between the amplitude and rate of change of the RVC and the instantaneous flicker perception,$P_\text{inst}$ , during the event is quantified. A method to estimate the amplitude of RVCs, and consequently to detect them, is proposed. The method is based on the maximum variation and rising slope of$P_\text{inst}$ . The model is tested on 576 hours of recordings from five different low voltage locations. It provides high precision, with a mean deviation below 0.2% in the RVC estimated amplitude. This method could be used by the IEC flickermeter to define a more precise and complete strategy to address the flicker assessment.- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 658-663
Improving the Detection of RVCs for a Better Assessment of Their Influence on Flicker
Rapid Voltage Changes (RVC) produce sudden illuminance changes that can generate flicker. The IEC 61 000-4-30 standard defines the procedure for the measurement of RVCs, but it does not include a metric to assess the effect of RVCs on the perception of flicker. The IEC 61 000-4-15 standard establishes the specification of a flickermeter, which assesses the effect of voltage fluctuations on flicker by calculating the flicker severity,$P_\text{st}$ , during a 10 min interval. However,$P_\text{st}$ is ineffective to adequately assess voltage variations as fast and short as RVCs. This work analyzes the main characteristics of the RVCs affecting flicker. The relationship between the amplitude and rate of change of the RVC and the instantaneous flicker perception,$P_\text{inst}$ , during the event is quantified. A method to estimate the amplitude of RVCs, and consequently to detect them, is proposed. The method is based on the maximum variation and rising slope of$P_\text{inst}$ . The model is tested on 576 hours of recordings from five different low voltage locations. It provides high precision, with a mean deviation below 0.2% in the RVC estimated amplitude. This method could be used by the IEC flickermeter to define a more precise and complete strategy to address the flicker assessment.- Open Access
Experimental Study of the Summation of Flicker Caused by Wind Turbines
Integration of wind energy into the grid faces a great challenge regarding power quality. The International Electrotechnical Commission (IEC) 61400-21 standard defines the electrical characteristics that need to be assessed in a Wind Turbine (WT), as well as the procedure to measure the disturbances produced by the WT. One of the parameters to be assessed are voltage fluctuations or flicker. To estimate the flicker emission of a Wind Power Plant (WPP), the standard establishes that a quadratic exponent should be used in the summation of the flicker emission of each WT. This exponent was selected based on studies carried out in WPPs with type I and II WTs. Advances in wind turbine technology have reduced their flicker emission, mainly thanks to the implementation of power electronics for the partial or total management of the power injected into the grid. This work is based on measurements from a WPP with 16 type III WTs. The flicker emission of a single WT and of the WPP were calculated. Low flicker emission values at the Point of Common Coupling (PCC) of the WPP were obtained. The flicker estimation at the PCC, based on the measurement from a single WT, was analyzed using different exponents. The results show that a cubic summation performs better than the quadratic one in the estimation of the flicker emission of a WPP with type III WTs.
Open AccessExperimental Study of the Summation of Flicker Caused by Wind Turbines
Integration of wind energy into the grid faces a great challenge regarding power quality. The International Electrotechnical Commission (IEC) 61400-21 standard defines the electrical characteristics that need to be assessed in a Wind Turbine (WT), as well as the procedure to measure the disturbances produced by the WT. One of the parameters to be assessed are voltage fluctuations or flicker. To estimate the flicker emission of a Wind Power Plant (WPP), the standard establishes that a quadratic exponent should be used in the summation of the flicker emission of each WT. This exponent was selected based on studies carried out in WPPs with type I and II WTs. Advances in wind turbine technology have reduced their flicker emission, mainly thanks to the implementation of power electronics for the partial or total management of the power injected into the grid. This work is based on measurements from a WPP with 16 type III WTs. The flicker emission of a single WT and of the WPP were calculated. Low flicker emission values at the Point of Common Coupling (PCC) of the WPP were obtained. The flicker estimation at the PCC, based on the measurement from a single WT, was analyzed using different exponents. The results show that a cubic summation performs better than the quadratic one in the estimation of the flicker emission of a WPP with type III WTs.
- Open Access
- 21 May 2019
- Published by MDPI AG in Preprints.org
Experimental Study of The Summation of Flicker Caused by Wind Turbines
Integration of wind energy into the grid faces a great challenge regarding power quality. The International Electrotechnical Commission (IEC)~61400-21 standard defines the electrical characteristics that need to be assessed in a Wind Turbine (WT), as well as the procedure to measure the disturbances produced by the WT. One of the parameters to be assessed are voltage fluctuations or flicker. To estimate the flicker emission of a Wind Power Plant (WPP), the standard establishes that a quadratic exponent should be used in the summation of the flicker emission of each WT. This exponent was selected based on studies carried out in WPPs with type I and II WTs. Advances in wind turbines technology have reduced their flicker emission, mainly thaks to the implementation of power electronics for the partial or total management of the power injected into the grid. This work is based on measurements from a WPP with 16 type III WTs. The flicker emission of a single WT and of the WPP were calculated. Low flicker emission values at the Point of Common Coupling (PCC) of the WPP were obtained. The flicker estimation at the PCC, based on the measurement from a single WT, was analyzed using different exponents. The results show that a cubic summation performs better than the quadratic one in the estimation of the flicker emission of a WPP with type III WTs.
- 21 May 2019
- Published by MDPI AG in Preprints.org
Open AccessExperimental Study of The Summation of Flicker Caused by Wind Turbines
Integration of wind energy into the grid faces a great challenge regarding power quality. The International Electrotechnical Commission (IEC)~61400-21 standard defines the electrical characteristics that need to be assessed in a Wind Turbine (WT), as well as the procedure to measure the disturbances produced by the WT. One of the parameters to be assessed are voltage fluctuations or flicker. To estimate the flicker emission of a Wind Power Plant (WPP), the standard establishes that a quadratic exponent should be used in the summation of the flicker emission of each WT. This exponent was selected based on studies carried out in WPPs with type I and II WTs. Advances in wind turbines technology have reduced their flicker emission, mainly thaks to the implementation of power electronics for the partial or total management of the power injected into the grid. This work is based on measurements from a WPP with 16 type III WTs. The flicker emission of a single WT and of the WPP were calculated. Low flicker emission values at the Point of Common Coupling (PCC) of the WPP were obtained. The flicker estimation at the PCC, based on the measurement from a single WT, was analyzed using different exponents. The results show that a cubic summation performs better than the quadratic one in the estimation of the flicker emission of a WPP with type III WTs.
- Open Access
Flicker of Modern Lighting Technologies Due to Rapid Voltage Changes
The purpose of the present paper is to evaluate the sensitivity of modern lighting technologies to different types of RVCs. In order to do that, 27 modern lamps—mainly LED—have been subjected to real RVCs and their response has been assessed. The detection of RVCs on the grid has been performed according to the IEC 61000-4-30 detection method, while the response of the lamps has been measured with a light flickermeter and characterized using the instantaneous flicker perception, as defined in IEC 61000-4-15. The obtained results show a high dispersion in the response of the modern lighting technologies and high values of flicker perception, although with a lower sensitivity than the incandescent lamp. The results led the authors to propose the definition of a new immunity test to be added to the lamp immunity protocol IEC TR-61547-1, to ensure that newly produced lamps cause limited irritation to grid users.
Open AccessFlicker of Modern Lighting Technologies Due to Rapid Voltage Changes
The purpose of the present paper is to evaluate the sensitivity of modern lighting technologies to different types of RVCs. In order to do that, 27 modern lamps—mainly LED—have been subjected to real RVCs and their response has been assessed. The detection of RVCs on the grid has been performed according to the IEC 61000-4-30 detection method, while the response of the lamps has been measured with a light flickermeter and characterized using the instantaneous flicker perception, as defined in IEC 61000-4-15. The obtained results show a high dispersion in the response of the modern lighting technologies and high values of flicker perception, although with a lower sensitivity than the incandescent lamp. The results led the authors to propose the definition of a new immunity test to be added to the lamp immunity protocol IEC TR-61547-1, to ensure that newly produced lamps cause limited irritation to grid users.
- 1 November 2017
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 92, 34-41
Sensitivity of modern lighting technologies at varying flicker severity levels
- 1 November 2017
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 92, 34-41
Sensitivity of modern lighting technologies at varying flicker severity levels
- 1 January 2017
- Published by Elsevier in Measurement
- Vol. 95, 116-127
A proposal for verification tests for the flicker measurement procedure of grid-connected wind turbines
- 1 January 2017
- Published by Elsevier in Measurement
- Vol. 95, 116-127
A proposal for verification tests for the flicker measurement procedure of grid-connected wind turbines
- 1 November 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 140, 312-320
Flicker measurement in real scenarios: Reducing the divergence from the human perception
- 1 November 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 140, 312-320
Flicker measurement in real scenarios: Reducing the divergence from the human perception
- 1 June 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 59, 1384-1395
Towards limiting the sensitivity of energy-efficient lighting to voltage fluctuations
- 1 June 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 59, 1384-1395
Towards limiting the sensitivity of energy-efficient lighting to voltage fluctuations