VBVadim Benkovich

Vadim Benkovich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vadim Benkovich has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nighttime intramedullary nailing of femoral fractures is not associated with worse outcomes: a 13-year Level I trauma center cohort

    by Artsiom Abialevich, Vadim Benkovich, Vladislav Osinsky, Yosef Adiniaev, Ilan Tzaytlin, Yotam Heinemann, Asaf Acker

    Background: Whether nighttime orthopedic trauma surgery adversely affects outcomes remains controversial. Evidence specifically addressing intramedullary fixation across femoral fracture locations remains limited. This study evaluated whether nighttime surgery was associated with a higher rate of recorded postoperative complications than daytime surgery. Methods: This retrospective observational cohort included adult patients with nonperiprosthetic femoral fractures treated with intramedullary fixation between January 2010 and January 2023 at a single Level I trauma center. Of 311 screened records, 23 were excluded because the patient was younger than 18 years ( n = 17) or the fracture was periprosthetic ( n = 6), leaving 288 procedures (242 daytime and 46 nighttime). The primary outcome was any recorded postoperative complication during available follow-up. Secondary outcomes included radiographic abnormality, delayed union (> 24 weeks), nonunion, revision surgery, and mortality. Surgeon experience was categorized as senior surgeon or resident. Exploratory fracture-location subgroup analyses and multivariable logistic regression were performed. Results: Nighttime patients were younger (35.1 ± 19.1 vs. 46.6 ± 24.6 years, p < 0.001), more frequently male (82.6% vs. 64.0%, p = 0.014), more often injured by a high-energy mechanism (80.4% vs. 56.6%, p = 0.002), and underwent surgery sooner after trauma (4.0 [2.0–10.0] vs. 18.0 [7.0–48.0] hours, p < 0.001). Residents were the recorded primary surgeon in 54.3% of nighttime and 39.3% of daytime procedures ( p = 0.057). After adjustment for demographic, injury, fracture-location, time-to-surgery, and surgeon-experience variables, nighttime surgery was not associated with the primary outcome (adjusted odds ratio 0.45, 95% confidence interval 0.15–1.38; p = 0.163). Delayed union (28.3% vs. 19.4%, p = 0.233) and revision surgery (4.3% vs. 12.4%, p = 0.130) did not differ significantly. Conclusions: In this single-center cohort, nighttime intramedullary fixation of femoral fractures was not associated with higher observed rates of postoperative complications, impaired fracture healing, or revision surgery compared with daytime fixation. These findings suggest that operative timing alone may not be a major determinant of outcome within an organized Level I trauma system. Nevertheless, the small nighttime cohort, unequal group sizes, fracture heterogeneity, and limited statistical precision require cautious interpretation and preclude definitive conclusions regarding equivalence or subgroup-specific safety. Larger multicenter studies with standardized assessment of surgeon experience, staffing, fatigue, and fracture-specific outcomes are warranted.

  • Assessment of Scaphoid Screw Centrality Using a Dedicated Axial Fluoroscopic View: A CT-Validated Study

    by Ilan Tzaytlin, Vadim Benkovich, Artsiom Abialevich, Layalee Abo-Naser, Guy Gershon, Nir Nazaro

    Background: Accurate intraoperative assessment of scaphoid screw position is limited by complex anatomy and standard fluoroscopic imaging. The surgical goal is near-central placement within a narrow corridor rather than a single geometric center. This study evaluates a dedicated axial fluoroscopic view for intraoperative assessment of screw centrality. Methods: A retrospective study included 54 patients who underwent scaphoid fixation with intraoperative fluoroscopy, including a dedicated axial view, and postoperative computed tomography (CT). Screw deviation from the geometric center of the scaphoid waist was measured on CT and compared with axial view measurements. Agreement was assessed using Spearman correlation and Bland-Altman analysis. Subgroup analyses were performed based on fracture characteristics. Results: Mean screw deviation was 1.73 ± 1.07 mm on CT and 1.25 ± 0.73 mm on the axial view. The mean absolute difference was 0.82 ± 0.99 mm. The axial view showed modest correlation with CT and a small systematic underestimation (mean bias −0.47 ± 1.20 mm), with wide 95% limits of agreement (−2.82 to 1.87 mm). Individual axial-view measurements should not be interpreted as interchangeable with CT. Displaced fractures demonstrated greater deviation on the axial view. Union was achieved in 93% of cases using a CT-based definition of osseous bridging. Conclusions: The axial fluoroscopic view provides additional intraoperative information for assessing scaphoid screw position. Its value lies in detecting relative eccentricity at the guidewire or screw stage rather than replicating CT measurements. This technique may help surgeons judge case-specific acceptability of guidewire trajectory and reduce unrecognized malposition.

  • Natural history of radiographic tracker pinhole recovery after robotic-assisted cementless total knee arthroplasty

    by Artsiom Abialevich, Boris Schebenkov, Vadim Benkovich

    Robotic-assisted total knee arthroplasty (RATKA) requires tracker pin placement, creating cortical pinholes that may remain visible on postoperative radiographs. This study evaluated the radiographic natural history of tracker pinhole recovery after RATKA. This retrospective cohort study included 369 consecutive primary RATKAs performed using 4.0-mm bicortical array pins. Each patient had one radiograph within approximately 1 month, 3–4 months, 5–6 months, and 9–12 months; no routine radiographs were scheduled at 7–8 months. Recovery phenotypes were early recovery at 5–6 months (n = 224), delayed recovery first documented at 9–12 months (n = 74), and persistent visibility at the 9-12-month assessment (n = 70). One pinhole-related fracture was analyzed separately. Separate exploratory logistic-regression models compared delayed versus early recovery and persistent visibility versus early recovery, with Benjamini-Hochberg false-discovery-rate adjustment. No complete recovery was observed at 1 month or 3–4 months. Early recovery occurred in 224 knees (60.7%), delayed recovery in 74 (20.1%), persistent visibility at 9–12 months in 70 (19.0%), and an adverse pin-site fracture in one (0.3%). Overall, 298 knees (80.8%) demonstrated radiographic recovery by the late assessment. BMI differed across the three recovery groups (Kruskal-Wallis p = 0.002). In adjusted analysis, higher BMI was associated with delayed versus early recovery (adjusted OR 1.10 per kg/m², 95% CI 1.04–1.17; p = 0.002; false-discovery-rate q = 0.022), but not with persistent visibility. Diabetes and smoking were not associated with either trajectory. Two periprosthetic fractures occurred (0.5%), both requiring reoperation; only one involved the tracker pinhole region. No revision TKA, femoral radiolucency, or progressive radiolucency was recorded. Tracker pinholes after RATKA remodel progressively, with most recovery documented by 5–6 months and additional recovery at the 9-12-month assessment. Higher BMI was associated with delayed but eventual recovery in an exploratory adjusted model, while no association was observed with persistent visibility. Persistent visibility was not accompanied by progressive implant-interface radiolucency. A fracture directly involving a tracker pinhole was rare.

  • Body mass index, weight bearing, and delayed union after femoral shaft fracture nailing: a retrospective cohort study

    by Ilan Tzaytlin, Artsiom Abialevich, Vladislav Osinsky, Yotam Heinemann, Vadim Benkovich, Asaf Acker

  • Collared Femoral Stems Have Lower Risk of Postoperative PPFs After THA: A Retrospective Cohort Study

    by Vadim Benkovich, Artsiom Abialevich, Boris Schebenkov, Avraham Benshtein, Evyatar Amar, Artur Akhtemzianov

    Background Periprosthetic fractures (PPFs) remain a serious complication following total hip arthroplasty (THA), contributing to increased morbidity and healthcare costs. Femoral stem design, particularly the presence of a collar, has been hypothesized to enhance axial stability and reduce micromotion, potentially lowering the risk of PPFs. This retrospective cohort study aimed to compare outcomes between collared and non-collared femoral stems in cementless THA. Methods We retrospectively analyzed 618 patients who underwent cementless THA between January 2014 and December 2024. Patients were stratified into two groups based on femoral stem design: collared (n = 308) and non-collared (n = 310). Baseline demographics, comorbidities (Charlson Comorbidity Index), fixation method, stem alignment, and complications were recorded. Periprosthetic fractures were classified using the Vancouver system, and radiological findings were evaluated across Gruen zones. Follow-up outcomes included stem subsidence, alignment, and radiographic changes. Results The collared stem group showed a significantly lower incidence of PPFs (0.97% vs. 3.87%, p = 0.033) and reduced stem subsidence (0.54 mm vs. 0.83 mm, p < 0.001). Radiographic analysis demonstrated improved neutral alignment (p < 0.001), fewer varus (p = 0.009) and valgus alignments (p = 0.021), and less cortical hypertrophy (p = 0.021) in collared stems. Reactive lines were more frequent in the collared group (p = 0.003). Hospital stay was marginally longer in this group (p = 0.012), with no significant difference in early complications. Conclusion Collared cementless femoral stems are associated with improved alignment, less subsidence, and a significantly lower risk of PPFs, supporting their biomechanical advantage in primary THA.

  • Anterior femoral notching during total knee arthroplasty: a predictor of periprosthetic femoral fractures?

    by V. Benkovich, A. Abialevich, B. Schebenkov, I. Tzaytlin, M. Fiterman, A. Aronskind, A. Benshtein

    Introduction Anterior femoral notching during TKA is thought to weaken the distal femur, potentially increasing periprosthetic fracture risk, but its clinical impact remains debated. This study examines whether notching independently predicts such fractures and assesses related clinical outcomes using the Tayside classification system for cortical violations. Methods A retrospective cohort study was conducted on 715 patients who underwent primary TKA. Patients were divided into Group 1 without notching (control group) and Group 2 with any presence of notching according to Tayside classification system, which assesses cortical violations based on the extent of involvement. Fracture incidence and additional multivariate analysis were used to control for confounding factors, including bone quality (presence of osteoporosis) and demographics. Results PPFs were significantly more frequent in the notching group (2.67%) than in the control group (0.24%) (p < 0.01). Despite 6.68% of patients having osteoporosis, no correlation with PPFs was found. All fractures occurred in female patients due to falls. A cortical defect > 2.5 mm was a potential predictor of femoral weakness, with larger defects in the notching group (2.20 ± 0.54 mm) vs. control (0.02 ± 0.16 mm), p < 0.01. PPF incidence was 1.33% for Grade 1 and 2 defects and 0.33% for Grade 3 defects. Conclusion Preventive strategies, including meticulous surgical technique and tailored postoperative rehabilitation, are essential to minimize PPF risk. Anterior femoral notching compromises femoral integrity, with defects > 2.5 mm significantly increasing fracture risk. Careful surgical planning, especially in patients with poor bone quality or advanced age, is crucial to optimize outcomes and reduce complications.


  • Open Access

    Comparative analysis of early radiolucencies in cementless versus cemented total knee arthroplasty

    by Vadim Benkovich, Artsiom Abialevich, Vladislav Osinsky, Guy Benkovich

    Aims: This study aimed to compare early outcomes of cemented and cementless total knee arthroplasty (TKA).Methods: We analyzed 593 patients who underwent cemented or cementless TKA between January 2017 and December 2022. Data collected included demographics, BMI, comorbidities, surgical variables, follow-up duration, and outcomes such as implant survivorship, radiolucencies (assessed using the Modern Knee Society Radiographic Evaluation System (MKSRES)), short-term complications, revision rates, periprosthetic fractures, hospital length of stay, and readmissions.Results: The study included 593 patients, equally divided into cemented and cementless groups. Age (p = 0.354) and sex (p = 0.342) were similar, though BMI was higher in the cementless group (p < 0.001). Comorbidities were comparable. Radiolucencies and osteolysis occurred in 12 cemented and ten cementless cases, with no significant differences across femoral and tibial zones (p ≥ 0.479). All radiolucencies were stable, partial, and non-progressive. No cases of aseptic loosening required revision. Revisions for periprosthetic fractures were rare (p = 0.218). Hospital length of stay (p = 0.623) and readmissions (p = 0.216) were similar between groups. The mean follow-up time postoperatively was slightly longer in the cementless group (4.22 years (SD 0.84)) compared to the cemented group (4.01 years (SD 1.03)) (p < 0.001).Conclusion: Cemented fixation remains the gold standard in TKA due to its reliability, yet advancements in implant design and indications support increasing adoption of cementless TKA. This study found comparable early outcomes for both methods, with stable radiolucent lines and no aseptic loosening during follow-up. The MKSRES facilitates standard radiological assessment, enabling precise implant monitoring and improving TKA outcome evaluation. These findings support the equivalence of cemented and cementless fixation in early survivorship.Cite this article: Bone Jt Open 2025;6(6):707–714.


  • Early radiological outcomes of imageless robotic-assisted total knee arthroplasty with VELYS: a comparative study of CPAK varus vs. valgus phenotypes

    by Benkovich Vadim, Abialevich Artsiom

    Robotic-assisted total knee arthroplasty (RATKA) offers enhanced intraoperative accuracy and real-time feedback. This study evaluates mid-term radiological outcomes of imageless RATKA in patients with mild and severe varus or valgus deformities, focusing on alignment accuracy and post-surgical outliers. A retrospective analysis was conducted on 257 patients who underwent RATKA. Demographic data, BMI, operative side, and key radiographic parameters—including pre- and postoperative hip-knee-ankle (HKA) angle, coronal alignment, joint line obliquity (MPTA + LDFA), tibial slope, and implant details—were recorded. Alignment phenotypes were classified using the CPAK system: Group 1 (varus phenotypes: CPAK I, IV, VII) and Group 2 (valgus phenotypes: CPAK III, VI, IX). RATKA significantly improved alignment in both groups. In Varus Group 1 (N = 181), maximum extension improved (p < 0.001), flexion remained unchanged. JLO and HKA improved (p < 0.001). In Valgus Group 2 (N = 60), extension improved (p < 0.001) with no flexion change. Group 2 had closure to neutral post-operative HKA and JLO (p < 0.001), aligning with close to CPAK 5 Neutral. Tibial resection was lower in Group 2 (7.43 ± 0.96) mm vs. (8.68 ± 1.45 mm). One tibial recut and one revision observed. Liner use favored 5 mm (80.11%) in Group 1, (90%) in Group 2. RATKA effectively optimized alignment and minimized tibial resection in valgus and varus deformities. Imageless RATKA provides accurate alignment correction in both varus and valgus deformities, even in severe cases. It enables minimal tibial resection and precise, balanced placement of cruciate-retaining implants, underscoring its role in optimizing modern TKA outcomes.