Frank Winterroth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Frank Winterroth has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey Brian Fowlkes
University of Michigan
9 shared publications - Scott Jeffrey Hollister
Wallace H. Coulter Department of Biomedical Engineering Georgia Institute of Technology Atlanta Georgia USA
6 shared publications Kyle W. Hollman
Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Sound Sight Research, Livonia, Michigan, USA
5 shared publicationsShiuhyang Kuo
Department of Oral and Maxillofacial Surgery, University of Michigan, Ann Arbor, Michigan, USA
5 shared publicationsStephen E. Feinberg
Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Department of Oral and Maxillofacial Surgery, University of Michigan, Ann Arbor, Michigan, USA
5 shared publicationsArindam Ganguly
Department of Chemistry, University of Michigan, Ann Arbor, Michigan
2 shared publications
Latest Publications
- Open Access
- 21 September 2016
- Published by IntechOpen
Applying High-Frequency Ultrasound to Examine Structures and Physical Properties of Cells and Tissues
Applying High-Frequency Ultrasound to Examine Structures and Physical Properties of Cells and Tissues | InTechOpen, Published on: 2016-09-21. Authors: Frank Winterroth
- 21 September 2016
- Published by IntechOpen
Open AccessApplying High-Frequency Ultrasound to Examine Structures and Physical Properties of Cells and Tissues
Applying High-Frequency Ultrasound to Examine Structures and Physical Properties of Cells and Tissues | InTechOpen, Published on: 2016-09-21. Authors: Frank Winterroth
- 1 September 2014
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 40 (9) , 2244-2251
High-Frequency Ultrasonic Imaging of Growth and Development in Manufactured Engineered Oral Mucosal Tissue Surfaces
- 1 September 2014
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 40 (9) , 2244-2251
High-Frequency Ultrasonic Imaging of Growth and Development in Manufactured Engineered Oral Mucosal Tissue Surfaces
- 1 May 2013
- Published by SAGE Publications in Tissue Engineering Part C: Methods
- Vol. 19 (5) , 345-351
Characterizing Morphology and Nonlinear Elastic Properties of Normal and Thermally Stressed Engineered Oral Mucosal Tissues Using Scanning Acoustic Microscopy
This study examines the use of high-resolution ultrasound to monitor changes in the morphology and nonlinear elastic properties of engineered oral mucosal tissues under normal and thermally stressed culture conditions. Nonlinear elastic properties were determined by first developing strain maps from acoustic ultrasound, followed by fitting of nonlinear stress–strain data to a 1-term Ogden model. Testing examined a clinically developed ex vivo produced oral mucosa equivalent (EVPOME). As seeded cells proliferate on an EVPOME surface, they produce a keratinized protective upper layer that fills in and smoothens out surface irregularities. These transformations can also alter the nonlinear stress/strain parameters as EVPOME cells differentiate. This EVPOME behavior is similar to those of natural oral mucosal tissues and in contrast to an unseeded scaffold. If ultrasonic monitoring could be developed, then tissue cultivation could be adjusted in-process to account for biological variations in their development of the stratified cellular layer. In addition to ultrasonic testing, an in-house-built compression system capable of accurate measurements on small (∼1.0–1.5 cm2) tissue samples is presented. Results showed a near 2.5-fold difference in the stiffness properties between the unstressed EVPOME and the noncell-seeded acellular scaffold (AlloDerm®). There were also 4×greater differences in root mean square values of the thickness in the unseeded AlloDerm compared to the mature unstressed EVPOME; this is a strong indicator for quantifying surface roughness.
- 1 May 2013
- Published by SAGE Publications in Tissue Engineering Part C: Methods
- Vol. 19 (5) , 345-351
Characterizing Morphology and Nonlinear Elastic Properties of Normal and Thermally Stressed Engineered Oral Mucosal Tissues Using Scanning Acoustic Microscopy
This study examines the use of high-resolution ultrasound to monitor changes in the morphology and nonlinear elastic properties of engineered oral mucosal tissues under normal and thermally stressed culture conditions. Nonlinear elastic properties were determined by first developing strain maps from acoustic ultrasound, followed by fitting of nonlinear stress–strain data to a 1-term Ogden model. Testing examined a clinically developed ex vivo produced oral mucosa equivalent (EVPOME). As seeded cells proliferate on an EVPOME surface, they produce a keratinized protective upper layer that fills in and smoothens out surface irregularities. These transformations can also alter the nonlinear stress/strain parameters as EVPOME cells differentiate. This EVPOME behavior is similar to those of natural oral mucosal tissues and in contrast to an unseeded scaffold. If ultrasonic monitoring could be developed, then tissue cultivation could be adjusted in-process to account for biological variations in their development of the stratified cellular layer. In addition to ultrasonic testing, an in-house-built compression system capable of accurate measurements on small (∼1.0–1.5 cm2) tissue samples is presented. Results showed a near 2.5-fold difference in the stiffness properties between the unstressed EVPOME and the noncell-seeded acellular scaffold (AlloDerm®). There were also 4×greater differences in root mean square values of the thickness in the unseeded AlloDerm compared to the mature unstressed EVPOME; this is a strong indicator for quantifying surface roughness.
- 31 October 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (10) , 1734-1742
Comparison of Scanning Acoustic Microscopy and Histology Images in Characterizing Surface Irregularities Among Engineered Human Oral Mucosal Tissues
- 31 October 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (10) , 1734-1742
Comparison of Scanning Acoustic Microscopy and Histology Images in Characterizing Surface Irregularities Among Engineered Human Oral Mucosal Tissues
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 286-289
Non-linear stress-strain measurements of ex vivo produced oral mucosal equivalent (EVPOME) compared to normal oral mucosal and skin tissue
Stress-strain curves of oral mucosal tissues were measured using direct mechanical testing. Measurements were conducted on both natural oral mucosal tissues and engineered devices, specifically a clinically developed ex vivo produced oral mucosal equivalent (EVPOME). As seeded cells proliferate on EVPOME devices, they produce a keratinized protective upper layer which fills in surface irregularities. These transformations can further alter stress-strain parameters as cells in EVPOME differentiate, more similar to natural oral mucosal tissues in contrast to an unseeded scaffold. In addition to tissue devices grown under normal conditions (37°C), EVPOMEs were also produced at 43°C. These thermally stressed specimens model possible failure mechanisms. Results from a mechanical deformation system capable of accurate measurements on small (approximately 1.0–1.5 cm 2 ) cylindrical tissue samples are presented. Deformations are produced by lowering a circular piston, with a radius smaller than the sample radius, onto the center of the sample. Resulting force is measured with a precision electronic balance. Cultured EVPOME was less stiff than AlloDerm®, but similar to native porcine buccal tissue. Porcine skin and porcine palate tissues were even less stiff. Thermally stressed EVPOME was less stiff than normally cultured EVPOME as expected because stressed keratin cells were damaged reducing the structural integrity of the tissue.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 286-289
Non-linear stress-strain measurements of ex vivo produced oral mucosal equivalent (EVPOME) compared to normal oral mucosal and skin tissue
Stress-strain curves of oral mucosal tissues were measured using direct mechanical testing. Measurements were conducted on both natural oral mucosal tissues and engineered devices, specifically a clinically developed ex vivo produced oral mucosal equivalent (EVPOME). As seeded cells proliferate on EVPOME devices, they produce a keratinized protective upper layer which fills in surface irregularities. These transformations can further alter stress-strain parameters as cells in EVPOME differentiate, more similar to natural oral mucosal tissues in contrast to an unseeded scaffold. In addition to tissue devices grown under normal conditions (37°C), EVPOMEs were also produced at 43°C. These thermally stressed specimens model possible failure mechanisms. Results from a mechanical deformation system capable of accurate measurements on small (approximately 1.0–1.5 cm 2 ) cylindrical tissue samples are presented. Deformations are produced by lowering a circular piston, with a radius smaller than the sample radius, onto the center of the sample. Resulting force is measured with a precision electronic balance. Cultured EVPOME was less stiff than AlloDerm®, but similar to native porcine buccal tissue. Porcine skin and porcine palate tissues were even less stiff. Thermally stressed EVPOME was less stiff than normally cultured EVPOME as expected because stressed keratin cells were damaged reducing the structural integrity of the tissue.
- 31 January 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (1) , 78-86
Examining and Analyzing Subcellular Morphology of Renal Tissue Treated by Histotripsy
- 31 January 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (1) , 78-86
Examining and Analyzing Subcellular Morphology of Renal Tissue Treated by Histotripsy
- 6 October 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (1) , 44-52
Acoustic Microscopy Analyses to Determine Good vs. Failed Tissue Engineered Oral Mucosa Under Normal or Thermally Stressed Culture Conditions
This study uses scanning acoustic microscopy (SAM) ultrasonic profilometry to determine acceptable vs. failed tissue engineered oral mucosa. Specifically, ex vivo-produced oral mucosal equivalents (EVPOMEs) under normal or thermally stressed culture conditions were scanned with the SAM operator blinded to the culture conditions. As seeded cells proliferate, they fill in and smooth out the surface irregularities; they then stratify and produce a keratinized protective upper layer. Some of these transformations could alter backscatter of ultrasonic signals and in the case of the thermally stressed cells, produce backscatter similar to an unseeded device. If non-invasive ultrasonic monitoring could be developed, then tissue cultivation could be adjusted to measure biological variations in the stratified surface. To create an EVPOME device, oral mucosa keratinocytes were seeded onto acellular cadaveric dermis. Two sets of EVPOMEs were cultured: one at physiological temperature 37 °C and the other at 43 °C. The specimens were imaged with SAM consisting of a single-element transducer: 61 MHz center frequency, 32 MHz bandwidth, 1.52 f#. Profilometry for the stressed and unseeded specimens showed higher surface irregularities compared to unstressed specimens. Elevated thermal stress retards cellular differentiation, increasing root mean square values; these results show that SAM can potentially monitor cell/tissue development.
- 6 October 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (1) , 44-52
Acoustic Microscopy Analyses to Determine Good vs. Failed Tissue Engineered Oral Mucosa Under Normal or Thermally Stressed Culture Conditions
This study uses scanning acoustic microscopy (SAM) ultrasonic profilometry to determine acceptable vs. failed tissue engineered oral mucosa. Specifically, ex vivo-produced oral mucosal equivalents (EVPOMEs) under normal or thermally stressed culture conditions were scanned with the SAM operator blinded to the culture conditions. As seeded cells proliferate, they fill in and smooth out the surface irregularities; they then stratify and produce a keratinized protective upper layer. Some of these transformations could alter backscatter of ultrasonic signals and in the case of the thermally stressed cells, produce backscatter similar to an unseeded device. If non-invasive ultrasonic monitoring could be developed, then tissue cultivation could be adjusted to measure biological variations in the stratified surface. To create an EVPOME device, oral mucosa keratinocytes were seeded onto acellular cadaveric dermis. Two sets of EVPOMEs were cultured: one at physiological temperature 37 °C and the other at 43 °C. The specimens were imaged with SAM consisting of a single-element transducer: 61 MHz center frequency, 32 MHz bandwidth, 1.52 f#. Profilometry for the stressed and unseeded specimens showed higher surface irregularities compared to unstressed specimens. Elevated thermal stress retards cellular differentiation, increasing root mean square values; these results show that SAM can potentially monitor cell/tissue development.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
High-resolution ultrasonic monitoring of cellular differentiation in an ex vivo produced oral mucosal equivalent (EVPOME)
Background, Motivation and Objective This study examines the use of high-resolution ultrasound to monitor an ex vivo produced oral mucosal equivalent (EVPOME) as it develops from oral keratinocytes being seeded on a dermal cadaveric scaffold, with surface variations, into a stratified uniform cellular layer. Ultrasonic profilometry should be able to detect filling and smoothing of surface irregularities as seeded cells proliferate. As these tissue-engineered structures develop, seeded cells stratify due to their differentiation in which they produce a keratinized protective upper layer. These cells change in shape and composition, lose water content, and accumulate proteins (keratins) transformations which could alter ultrasonic backscatter. If non-invasive ultrasonic monitoring could be developed then tissue cultivation could be adjusted in-process to account for variations in the development and manufacture of the stratified cellular layer. Statement of Contribution/Methods To create an EVPOME specimen, oral mucosa keratinocytes were dissociated from human oral tissue samples and then seeded onto a scaffold of acellular cadaveric dermis. EVPOME's were cultured submerged for 4 days to form a continuous epithelial monolayer and then raised to an air-liquid interface for another 7-10 days. At specific intervals (1, 2, 4, and 7 days) specimens were imaged with an ultrasound acoustic microscope that consists of a single-element transducer (61 MHz center frequency, 32 MHz bandwidth, 1.52 f#) with a three-axis stepper-motor-controlled positioning system. Lateral step size was 15 ?m, about half of the 37 ?m resolution. Ultrasonic images were created using confocal image reconstruction. Tissue surfaces were determined by thresholding the magnitude of the signal at the first axial incidence of a value safely above noise. Roughness was measured with root-mean-squared (rms) surface height. Echogenicity was measured using apparent integrated backscatter (AIBS) with respect to a fused silica flat. AIBS was calculated over bandwidth after gating the signal with a window centered at the specimen surface. Results There was no considerable change in measured roughness (20 to 22 ?m) from unseeded scaffold through day 4 after seeding. Between days 4 and 7 rms heights decreased from 22 ?m to 13 ?m. AIBS first changed between days 1 and 2 when it dropped from -30 dB to -41 dB. Echogenicity increased again from days 4 to 7 from -40 dB to -29 dB. Discussion and Conclusions Ultrasonic profilometry did not detect seeded cells filling in scaffold irregularities until cells had sufficiently stratified and differentiated by day 7. The initial drop in AIBS on day 2 may be due to undifferentiated seeded cells attenuating but not scattering ultrasound at that layer. More maturely differentiated cells, present at day 7, show brighter echogenicity possibly due to cellular changes. These initial results show that ultrasonic characterization may have potential to monitor...
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
High-resolution ultrasonic monitoring of cellular differentiation in an ex vivo produced oral mucosal equivalent (EVPOME)
Background, Motivation and Objective This study examines the use of high-resolution ultrasound to monitor an ex vivo produced oral mucosal equivalent (EVPOME) as it develops from oral keratinocytes being seeded on a dermal cadaveric scaffold, with surface variations, into a stratified uniform cellular layer. Ultrasonic profilometry should be able to detect filling and smoothing of surface irregularities as seeded cells proliferate. As these tissue-engineered structures develop, seeded cells stratify due to their differentiation in which they produce a keratinized protective upper layer. These cells change in shape and composition, lose water content, and accumulate proteins (keratins) transformations which could alter ultrasonic backscatter. If non-invasive ultrasonic monitoring could be developed then tissue cultivation could be adjusted in-process to account for variations in the development and manufacture of the stratified cellular layer. Statement of Contribution/Methods To create an EVPOME specimen, oral mucosa keratinocytes were dissociated from human oral tissue samples and then seeded onto a scaffold of acellular cadaveric dermis. EVPOME's were cultured submerged for 4 days to form a continuous epithelial monolayer and then raised to an air-liquid interface for another 7-10 days. At specific intervals (1, 2, 4, and 7 days) specimens were imaged with an ultrasound acoustic microscope that consists of a single-element transducer (61 MHz center frequency, 32 MHz bandwidth, 1.52 f#) with a three-axis stepper-motor-controlled positioning system. Lateral step size was 15 ?m, about half of the 37 ?m resolution. Ultrasonic images were created using confocal image reconstruction. Tissue surfaces were determined by thresholding the magnitude of the signal at the first axial incidence of a value safely above noise. Roughness was measured with root-mean-squared (rms) surface height. Echogenicity was measured using apparent integrated backscatter (AIBS) with respect to a fused silica flat. AIBS was calculated over bandwidth after gating the signal with a window centered at the specimen surface. Results There was no considerable change in measured roughness (20 to 22 ?m) from unseeded scaffold through day 4 after seeding. Between days 4 and 7 rms heights decreased from 22 ?m to 13 ?m. AIBS first changed between days 1 and 2 when it dropped from -30 dB to -41 dB. Echogenicity increased again from days 4 to 7 from -40 dB to -29 dB. Discussion and Conclusions Ultrasonic profilometry did not detect seeded cells filling in scaffold irregularities until cells had sufficiently stratified and differentiated by day 7. The initial drop in AIBS on day 2 may be due to undifferentiated seeded cells attenuating but not scattering ultrasound at that layer. More maturely differentiated cells, present at day 7, show brighter echogenicity possibly due to cellular changes. These initial results show that ultrasonic characterization may have potential to monitor...
- 5 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (5) , 995-1005
Quantitative ultrasound backscatter for pulsed cavitational ultrasound therapy-histotripsy
Histotripsy is a well-controlled ultrasonic tissue ablation technology that mechanically and progressively fractionates tissue structures using cavitation. The fractionated tissue volume can be monitored with ultrasound imaging because a significant ultrasound backscatter reduction occurs. This paper correlates the ultrasound backscatter reduction with the degree of tissue fractionation characterized by the percentage of remaining normal-appearing cell nuclei on histology. Different degrees of tissue fractionation were generated in vitro in freshly excised porcine kidneys by varying the number of therapeutic ultrasound pulses from 100 to 2000 pulses per treatment location. All ultrasound pulses were 15 cycles at 1 MHz delivered at 100 Hz pulse repetition frequency and 19 MPa peak negative pressure. The results showed that the normalized backscatter intensity decreased exponentially with increasing number of pulses. Correspondingly, the percentage of normal appearing nuclei in the treated area decreased exponentially as well. A linear correlation existed between the normalized backscatter intensity and the percentage of normal appearing cell nuclei in the treated region. This suggests that the normalized backscatter intensity may be a potential quantitative real-time feedback parameter for histotripsy-induced tissue fractionation. This quantitative feedback may allow the prediction of local clinical outcomes, i.e., when a tissue volume has been sufficiently treated.
- 5 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (5) , 995-1005
Quantitative ultrasound backscatter for pulsed cavitational ultrasound therapy-histotripsy
Histotripsy is a well-controlled ultrasonic tissue ablation technology that mechanically and progressively fractionates tissue structures using cavitation. The fractionated tissue volume can be monitored with ultrasound imaging because a significant ultrasound backscatter reduction occurs. This paper correlates the ultrasound backscatter reduction with the degree of tissue fractionation characterized by the percentage of remaining normal-appearing cell nuclei on histology. Different degrees of tissue fractionation were generated in vitro in freshly excised porcine kidneys by varying the number of therapeutic ultrasound pulses from 100 to 2000 pulses per treatment location. All ultrasound pulses were 15 cycles at 1 MHz delivered at 100 Hz pulse repetition frequency and 19 MPa peak negative pressure. The results showed that the normalized backscatter intensity decreased exponentially with increasing number of pulses. Correspondingly, the percentage of normal appearing nuclei in the treated area decreased exponentially as well. A linear correlation existed between the normalized backscatter intensity and the percentage of normal appearing cell nuclei in the treated region. This suggests that the normalized backscatter intensity may be a potential quantitative real-time feedback parameter for histotripsy-induced tissue fractionation. This quantitative feedback may allow the prediction of local clinical outcomes, i.e., when a tissue volume has been sufficiently treated.
- 1 February 2009
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 35 (2) , 245-255
Size Measurement of Tissue Debris Particles Generated from Pulsed Ultrasound Cavitational Therapy – Histotripsy
- 1 February 2009
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 35 (2) , 245-255
Size Measurement of Tissue Debris Particles Generated from Pulsed Ultrasound Cavitational Therapy – Histotripsy