AEAlexandra Ehlers

Alexandra Ehlers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexandra Ehlers has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accidental intoxications in toddlers: lack of cross-reactivity of vilazodone and its urinary metabolite M17 with drug of abuse screening immunoassays

    by Christina D. Martinez-Brokaw, Joshua B. Radke, Joshua G. Pierce, Alexandra Ehlers, Sean Ekins, Kelly E. Wood, Jon Maakestad, Jacqueline A. Rymer, Kenichi Tamama, Matthew D. Krasowski

    Vilazodone is an FDA approved medication used to treat major depressive disorder. The authors describe two cases of accidental vilazodone exposure in toddlers who presented with symptoms similar to amphetamine exposure and also with unexplained positive amphetamine urine immunoassay drug screens. Given a lack of published data on cross-reactivity of vilazodone and its metabolites with drug of abuse screening tests, the authors investigated drug of abuse immunoassay cross-reactivity of vilazodone and metabolites using computational and empirical approaches. To ascertain the likelihood that vilazodone would cross-react with drug of abuse screening immunoassays, the authors assessed the two-dimensional (2D) similarity of the vilazodone parent molecule and known metabolites to an array of antigenic targets for urine immunoassay drug screens. To facilitate studies of the commercially unavailable M17 metabolite, it was prepared synthetically through a novel scheme. Urine and serum were spiked with vilazodone and M17 into urine (200–100,000 ng/mL) and serum (20–2000 ng/mL) samples and tested for cross-reactivity. Computational analysis using 2D similarity showed that vilazodone and metabolites have generally low similarity to antigenic targets of common drug of abuse screening immunoassays, predicting weak or no cross-reactivity. The M17 metabolite had 2D similarity to amphetamines and tricyclic antidepressants in a range similar to some other compounds exhibiting weak cross-reactivity on these immunoassays. Cross-reactivity testing was therefore performed on two different urine amphetamines immunoassays and a serum tricyclic antidepressant immunoassay. However, actual testing of cross reactivity for vilazodone and the M17 metabolite did not detect cross-reactivity for any urine amphetamines screen at concentrations up to 100,000 ng/mL and for a serum tricyclic antidepressants assays at concentrations up to 2000 ng/mL. While the vilazodone metabolite M17 has weak 2D structural similarity to amphetamines and tricyclic antidepressants, the current study did not demonstrate any experimental cross-reactivity with two different urine amphetamines immunoassays and a serum tricyclic antidepressant immunoassay. Vilazodone ingestions in young children present a diagnostic challenge in their similarity to amphetamine ingestions and the lack of routine laboratory tests for vilazodone. Further work is needed to understand the metabolic profile for vilazodone in children versus adults.


  • Open Access

    A rapid analysis of plasma/serum ethylene and propylene glycol by headspace gas chromatography

    by Alexandra Ehlers, Cory Morris, Matthew D Krasowski

    A rapid headspace-gas chromatography (HS-GC) method was developed for the analysis of ethylene glycol and propylene glycol in plasma and serum specimens using 1,3-propanediol as the internal standard. The method employed a single-step derivitization using phenylboronic acid, was linear to 200 mg/dL and had a lower limit of quantitation of 1 mg/dL suitable for clinical analyses. The analytical method described allows for laboratories with HS-GC instrumentation to analyze ethanol, methanol, isopropanol, ethylene glycol, and propylene glycol on a single instrument with rapid switch-over from alcohols to glycols analysis. In addition to the novel HS-GC method, a retrospective analysis of patient specimens containing ethylene glycol and propylene glycol was also described. A total of 36 patients ingested ethylene glycol, including 3 patients who presented with two separate admissions for ethylene glycol toxicity. Laboratory studies on presentation to hospital for these patients showed both osmolal and anion gap in 13 patients, osmolal but not anion gap in 13 patients, anion but not osmolal gap in 8 patients, and 1 patient with neither an osmolal nor anion gap. Acidosis on arterial blood gas was present in 13 cases. Only one fatality was seen; this was a patient with initial serum ethylene glycol concentration of 1282 mg/dL who died on third day of hospitalization. Propylene glycol was common in patients being managed for toxic ingestions, and was often attributed to iatrogenic administration of propylene glycol-containing medications such as activated charcoal and intravenous lorazepam. In six patients, propylene glycol contributed to an abnormally high osmolal gap. The common presence of propylene glycol in hospitalized patients emphasizes the importance of being able to identify both ethylene glycol and propylene glycol by chromatographic methods.