Ioannis Chasiotis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ioannis Chasiotis has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Debashish Das
University of Illinois at Urbana-Champaign
3 shared publicationsDimitrios A. Antartis
3 shared publications- Shen J. Dillon
Department of Materials Science and Engineering University of California Irvine Irvine California USA
3 shared publications - Debashish Das
Department of Mechanical Engineering Indian Institute of Science Bengaluru Karnataka India
2 shared publications Fan Yang
Aerospace Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801, USA
2 shared publicationsGuy M. Genin
Mechanical Engineering and Materials Science, Washington University, St. Louis, MO 63130, USA
2 shared publications
Latest Publications
- Open Access
- 4 December 2025
- Published by Springer Nature in Experimental Mechanics
- Vol. 66 (1) , 137-152
High-Speed Atomic Force Microscopy for In-Situ Full-Field Measurement of Large Deformations
Background: Atomic Force Microscopy (AFM) is widely used for high-resolution imaging and for probing the contact mechanics and multiphysics of materials at the nanoscale. However, its application to quantitative, full-field finite deformation studies of soft materials remains unexplored. Objective: This work focuses on accurate high-speed, high-resolution AFM imaging of polydimethylsiloxane (PDMS) specimens in order to compute full-field strains with nanoscale spatial resolution. Methods: The AFM cantilever dynamics were optimized for accurate high-speed imaging through independent control of the cantilever resonance frequency and spring constant, and by active Q-control. A miniature mechanical testing device was developed to fit inside a compact AFM, thereby enabling simultaneous mechanical loading and nanoscale imaging via a symmetric specimen stretching mechanism. Full-field in-plane strain fields from PDMS specimens subjected to finite deformations were extracted via Digital Image Correlation (DIC) from AFM images obtained during incremental specimen stretching. Results: This experimental methodology successfully enables low error AFM imaging of PDMS at 100 Hz scan rate, signifying a 100-fold reduction in image acquisition time compared to previous studies using AFM to measure strain fields. The imaging repeatability, assessed with the aid of DIC, was accurate within 0.5% error in mean strain. Full-field strains derived from high-speed AFM images of PDMS specimens tested in situ under an AFM, agreed very well with macroscale optical measurements, including Poisson’s ratio calculations obtained up to the point of specimen failure. Conclusion: The results of this study illustrate the feasibility of high-speed AFM as a quantitative tool for nanoscale full-field strain analysis, offering new opportunities for probing the large deformation mechanics of soft materials.
- 4 December 2025
- Published by Springer Nature in Experimental Mechanics
- Vol. 66 (1) , 137-152
Open AccessHigh-Speed Atomic Force Microscopy for In-Situ Full-Field Measurement of Large Deformations
Background: Atomic Force Microscopy (AFM) is widely used for high-resolution imaging and for probing the contact mechanics and multiphysics of materials at the nanoscale. However, its application to quantitative, full-field finite deformation studies of soft materials remains unexplored. Objective: This work focuses on accurate high-speed, high-resolution AFM imaging of polydimethylsiloxane (PDMS) specimens in order to compute full-field strains with nanoscale spatial resolution. Methods: The AFM cantilever dynamics were optimized for accurate high-speed imaging through independent control of the cantilever resonance frequency and spring constant, and by active Q-control. A miniature mechanical testing device was developed to fit inside a compact AFM, thereby enabling simultaneous mechanical loading and nanoscale imaging via a symmetric specimen stretching mechanism. Full-field in-plane strain fields from PDMS specimens subjected to finite deformations were extracted via Digital Image Correlation (DIC) from AFM images obtained during incremental specimen stretching. Results: This experimental methodology successfully enables low error AFM imaging of PDMS at 100 Hz scan rate, signifying a 100-fold reduction in image acquisition time compared to previous studies using AFM to measure strain fields. The imaging repeatability, assessed with the aid of DIC, was accurate within 0.5% error in mean strain. Full-field strains derived from high-speed AFM images of PDMS specimens tested in situ under an AFM, agreed very well with macroscale optical measurements, including Poisson’s ratio calculations obtained up to the point of specimen failure. Conclusion: The results of this study illustrate the feasibility of high-speed AFM as a quantitative tool for nanoscale full-field strain analysis, offering new opportunities for probing the large deformation mechanics of soft materials.
- 28 June 2025
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 36 (18-19) , 1285-1289
Full-field strain measurements at the nanoscale
A summary of advances in nanomechanical characterization of materials by utilizing high-spatial resolution Atomic Force Microscopy (AFM) for full-field strain measurements is presented along with perspectives for fast and accurate AFM imaging for nanoscale strain mapping. The combination of in situ AFM, and more broadly Scanning Probe Microscopy (SPM), specimen imaging during mechanical testing, with Digital Image Correlation (DIC) based strain calculations has provided full-field nanoscale deformation data in heterogeneous materials, which have enabled the investigation of microstructural effects on local deformation and fracture processes at the nanoscale. However, the inherent line-by-line scanning principle of an AFM requires long image acquisition times, thus prohibiting its application to viscoelastic materials while also increasing the susceptibility of AFM images to noise and thermal drift. Advances in control electronics, photodetectors, and cantilever microfabrication and excitation methods have opened new possibilities to reduce the acquisition time for high-resolution AFM images by 1–2 orders of magnitude, hence making the AFM/DIC experimental methodology an effective tool for nanomechanical studies.
- 28 June 2025
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 36 (18-19) , 1285-1289
Full-field strain measurements at the nanoscale
A summary of advances in nanomechanical characterization of materials by utilizing high-spatial resolution Atomic Force Microscopy (AFM) for full-field strain measurements is presented along with perspectives for fast and accurate AFM imaging for nanoscale strain mapping. The combination of in situ AFM, and more broadly Scanning Probe Microscopy (SPM), specimen imaging during mechanical testing, with Digital Image Correlation (DIC) based strain calculations has provided full-field nanoscale deformation data in heterogeneous materials, which have enabled the investigation of microstructural effects on local deformation and fracture processes at the nanoscale. However, the inherent line-by-line scanning principle of an AFM requires long image acquisition times, thus prohibiting its application to viscoelastic materials while also increasing the susceptibility of AFM images to noise and thermal drift. Advances in control electronics, photodetectors, and cantilever microfabrication and excitation methods have opened new possibilities to reduce the acquisition time for high-resolution AFM images by 1–2 orders of magnitude, hence making the AFM/DIC experimental methodology an effective tool for nanomechanical studies.
- Open Access
- 5 February 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (10) , 1841-1848
An integrated experimental-computational investigation of the mechanical behavior of random nanofiber networks
An integrated experimental-computational methodology was developed to study the mechanical behavior of random polymer nanofiber networks with controlled network structural parameters. Random nanofiber networks, comprised of continuous polyethylene oxide (PEO) nanofibers with ∼250 nm diameter and controlled mean fiber segment length, were designed with a computer algorithm and printed via near-field electrospinning. The structure of the same networks served as input to a computational model to obtain predictions of the macroscopic mechanical response. This methodology provides consistency in fabricating, testing and simulating nominally identical random fiber networks. Specimens with 500 to 5000 nanofibers were subjected to uniaxial tension and compared to modeling predictions for the network mechanical behavior. The predictions by the computational model, with inputs from the experimental network structure, the measured single PEO nanofiber properties, and the fiber crimp parameter, agreed with the experimental results both quantitatively and with respect to the dependence of the measured quantities on the network parameters. The network stiffness and strength followed a power-law scaling with the network density, with exponents 2.78 ± 0.15 and 1.59 ± 0.04, respectively, while the network stretch at failure gradually decreased with increasing network fiber density. Finally, the experimentally determined network toughness demonstrated a rather weak power-law dependence on the network fiber density (exponent of 1.18 ± 0.12).
- 5 February 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (10) , 1841-1848
Open AccessAn integrated experimental-computational investigation of the mechanical behavior of random nanofiber networks
An integrated experimental-computational methodology was developed to study the mechanical behavior of random polymer nanofiber networks with controlled network structural parameters. Random nanofiber networks, comprised of continuous polyethylene oxide (PEO) nanofibers with ∼250 nm diameter and controlled mean fiber segment length, were designed with a computer algorithm and printed via near-field electrospinning. The structure of the same networks served as input to a computational model to obtain predictions of the macroscopic mechanical response. This methodology provides consistency in fabricating, testing and simulating nominally identical random fiber networks. Specimens with 500 to 5000 nanofibers were subjected to uniaxial tension and compared to modeling predictions for the network mechanical behavior. The predictions by the computational model, with inputs from the experimental network structure, the measured single PEO nanofiber properties, and the fiber crimp parameter, agreed with the experimental results both quantitatively and with respect to the dependence of the measured quantities on the network parameters. The network stiffness and strength followed a power-law scaling with the network density, with exponents 2.78 ± 0.15 and 1.59 ± 0.04, respectively, while the network stretch at failure gradually decreased with increasing network fiber density. Finally, the experimentally determined network toughness demonstrated a rather weak power-law dependence on the network fiber density (exponent of 1.18 ± 0.12).
- 13 February 2023
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 57 (4) , 507-519
Local electrical conductivity of carbon black/PDMS nanocomposites subjected to large deformations
The full-field microscale electrical behavior of polydimethylsiloxane (PDMS) matrix composites with 12 wt% (below the electrical percolation threshold) and 20 wt% (above the electrical percolation threshold) carbon black (CB) nanoparticles was obtained with the aid of Conductive Atomic Force Microscopy (C-AFM) as a function of uniaxial tensile strain. A comparison between the macroscale and the microscale 2D strain fields showed that 25 × 25 μm 2 specimen domains can serve as a representative surface element (RSE) to describe the macroscale mechanical response under finite deformations. The same surface domain size was shown to serve as RSE for the local electrical behavior of CB/PDMS nanocomposites at small and large strains. The transverse specimen contraction due to the Poisson’s effect increased the through-thickness conductivity of 12 wt% CB specimens, with a rapid increase in the total electric current measured at the scale of the RSE taking place above 23% uniaxial true strain. The locally dominant tunneling conductance in the undeformed specimen state transitioned to a combination of Ohmic (linear local current-voltage (I–V) characteristics) and tunneling (parabolic local I–V characteristics) at 35% uniaxial true strain. In comparison, the local I–V characteristics of undeformed PDMS composites with 20 wt% CB were a combination of Ohmic (contributing the majority of the total current) and tunneling. Upon application of 35% uniaxial true strain the vast majority of local conduction sites became Ohmic, while the total electric current at the scale of the RSE increased relatively linearly with applied strain.
- 13 February 2023
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 57 (4) , 507-519
Local electrical conductivity of carbon black/PDMS nanocomposites subjected to large deformations
The full-field microscale electrical behavior of polydimethylsiloxane (PDMS) matrix composites with 12 wt% (below the electrical percolation threshold) and 20 wt% (above the electrical percolation threshold) carbon black (CB) nanoparticles was obtained with the aid of Conductive Atomic Force Microscopy (C-AFM) as a function of uniaxial tensile strain. A comparison between the macroscale and the microscale 2D strain fields showed that 25 × 25 μm 2 specimen domains can serve as a representative surface element (RSE) to describe the macroscale mechanical response under finite deformations. The same surface domain size was shown to serve as RSE for the local electrical behavior of CB/PDMS nanocomposites at small and large strains. The transverse specimen contraction due to the Poisson’s effect increased the through-thickness conductivity of 12 wt% CB specimens, with a rapid increase in the total electric current measured at the scale of the RSE taking place above 23% uniaxial true strain. The locally dominant tunneling conductance in the undeformed specimen state transitioned to a combination of Ohmic (linear local current-voltage (I–V) characteristics) and tunneling (parabolic local I–V characteristics) at 35% uniaxial true strain. In comparison, the local I–V characteristics of undeformed PDMS composites with 20 wt% CB were a combination of Ohmic (contributing the majority of the total current) and tunneling. Upon application of 35% uniaxial true strain the vast majority of local conduction sites became Ohmic, while the total electric current at the scale of the RSE increased relatively linearly with applied strain.
- 14 March 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (11) , 114101
Strain rate induced toughening of individual collagen fibrils
The nonlinear mechanical behavior of individual nanoscale collagen fibrils is governed by molecular stretching and sliding that result in a viscous response, which is still not fully understood. Toward this goal, the in vitro mechanical behavior of individual reconstituted mammalian collagen fibrils was quantified in a broad range of strain-rates, spanning roughly six orders of magnitude, from 10−4 to 35 s−1. It is shown that the nonlinear mechanical response is strain rate sensitive with the tangent modulus in the linear deformation regime increasing monotonically from 214 ± 8 to 358 ± 11 MPa. More pronounced is the effect of the strain rate on the ultimate tensile strength that is found to increase monotonically by a factor of four, from 42 ± 6 to 160 ± 14 MPa. Importantly, fibril strengthening takes place without a reduction in ductility, which results in equivalently large increase in toughness with the increasing strain rate. This experimental strain rate dependent mechanical response is captured well by a structural constitutive model that incorporates the salient features of the collagen microstructure via a process of gradual recruitment of kinked tropocollagen molecules, thus giving rise to the initial “toe-heel” mechanical behavior, followed by molecular stretching and sustained intermolecular slip that is initiated at a strain rate dependent stress threshold. The model shows that the fraction of tropocollagen molecules undergoing straightening increases continuously during loading, whereas molecular sliding is initiated after a small fibril strain (1%–2%) and progressively increases with applied strain.
- 14 March 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (11) , 114101
Strain rate induced toughening of individual collagen fibrils
The nonlinear mechanical behavior of individual nanoscale collagen fibrils is governed by molecular stretching and sliding that result in a viscous response, which is still not fully understood. Toward this goal, the in vitro mechanical behavior of individual reconstituted mammalian collagen fibrils was quantified in a broad range of strain-rates, spanning roughly six orders of magnitude, from 10−4 to 35 s−1. It is shown that the nonlinear mechanical response is strain rate sensitive with the tangent modulus in the linear deformation regime increasing monotonically from 214 ± 8 to 358 ± 11 MPa. More pronounced is the effect of the strain rate on the ultimate tensile strength that is found to increase monotonically by a factor of four, from 42 ± 6 to 160 ± 14 MPa. Importantly, fibril strengthening takes place without a reduction in ductility, which results in equivalently large increase in toughness with the increasing strain rate. This experimental strain rate dependent mechanical response is captured well by a structural constitutive model that incorporates the salient features of the collagen microstructure via a process of gradual recruitment of kinked tropocollagen molecules, thus giving rise to the initial “toe-heel” mechanical behavior, followed by molecular stretching and sustained intermolecular slip that is initiated at a strain rate dependent stress threshold. The model shows that the fraction of tropocollagen molecules undergoing straightening increases continuously during loading, whereas molecular sliding is initiated after a small fibril strain (1%–2%) and progressively increases with applied strain.
- 5 March 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 163, 63-77
Nonlinear time-dependent mechanical behavior of mammalian collagen fibrils
- 5 March 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 163, 63-77
Nonlinear time-dependent mechanical behavior of mammalian collagen fibrils
- 6 December 2021
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (3) , 2101583
Control of Surface Wrinkling through Compliant Nanostructured Interfaces
Surface wrinkling occurs due to the mechanical instability induced by the stiffness mismatch between a soft substrate and a stiff film. In a two‐layer system comprised of a thick compliant substrate and a thin stiff film, the wrinkle pattern, as described by the wrinkle wavelength, amplitude, and orientation, is limited by the material properties and thickness of the two layers. In this work, an interface layer of nanostructures fabricated by glancing angle deposition (GLAD) is introduced to modify the surface wrinkling of polydimethylsiloxane due to a Cu film, thus enabling improved control of wrinkling in an otherwise constrained material system. Isotropic (nanospring) and orthotropic (nanochevron) Cu interfaces are GLAD‐deposited with different geometric parameters to control the in‐plane stiffness of the interface. The isotropic nanospring films provide a novel means to control the physical length scale of wrinkle patterns, namely, both the wavelength and the amplitude of surface wrinkles, while maintaining the amplitude‐to‐wavelength aspect ratio. The anisotropic nanochevron films result in anisotropy ratio of ≈10 which provides a unique means to modify the wrinkle direction independently of the direction of the applied load. The prediction by the experimentally calibrated analytical model is shown to be in good agreement with the experiment.
- 6 December 2021
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (3) , 2101583
Control of Surface Wrinkling through Compliant Nanostructured Interfaces
Surface wrinkling occurs due to the mechanical instability induced by the stiffness mismatch between a soft substrate and a stiff film. In a two‐layer system comprised of a thick compliant substrate and a thin stiff film, the wrinkle pattern, as described by the wrinkle wavelength, amplitude, and orientation, is limited by the material properties and thickness of the two layers. In this work, an interface layer of nanostructures fabricated by glancing angle deposition (GLAD) is introduced to modify the surface wrinkling of polydimethylsiloxane due to a Cu film, thus enabling improved control of wrinkling in an otherwise constrained material system. Isotropic (nanospring) and orthotropic (nanochevron) Cu interfaces are GLAD‐deposited with different geometric parameters to control the in‐plane stiffness of the interface. The isotropic nanospring films provide a novel means to control the physical length scale of wrinkle patterns, namely, both the wavelength and the amplitude of surface wrinkles, while maintaining the amplitude‐to‐wavelength aspect ratio. The anisotropic nanochevron films result in anisotropy ratio of ≈10 which provides a unique means to modify the wrinkle direction independently of the direction of the applied load. The prediction by the experimentally calibrated analytical model is shown to be in good agreement with the experiment.
- 1 September 2021
- Published by Elsevier in Solar Energy
- Vol. 225, 643-655
Control of substrate strain transfer to thin film photovoltaics via interface design
- 1 September 2021
- Published by Elsevier in Solar Energy
- Vol. 225, 643-655
Control of substrate strain transfer to thin film photovoltaics via interface design
- 12 March 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (12) , 11715-11721
Nanofibrillar Si Helices for Low-Stress, High-Capacity Li+ Anodes with Large Affine Deformations
We report on the chemical lithiation of long microscale helices composed of densely packed amorphous silicon (aSi) nanofibrils, fabricated by glancing angle deposition (GLAD) through e-beam evaporation. In situ electron microscopy and companion finite element modeling demonstrate that the nanofibrillar structure of the aSi helices allows for 2 orders of magnitude faster effective rates for Li diffusion (D0 = 10–10 cm2/s) compared to solid aSi nanowires, while also averting fragmentation during lithiation. More importantly, it is shown that specific helical geometries can accommodate large, lithium-induced, volumetric expansions without shape distortion. A major advantage of the helical nanostructures is that the compressive force generated due to lithiation-induced expansion is an order of magnitude smaller than in straight nanocolumns that permanently buckle during lithiation. Thus, GLAD-fabricated films composed of dense periodic microscale helices with properly designed coil geometries are highly suitable for robust, high-capacity Li+ anodes.
- 12 March 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (12) , 11715-11721
Nanofibrillar Si Helices for Low-Stress, High-Capacity Li+ Anodes with Large Affine Deformations
We report on the chemical lithiation of long microscale helices composed of densely packed amorphous silicon (aSi) nanofibrils, fabricated by glancing angle deposition (GLAD) through e-beam evaporation. In situ electron microscopy and companion finite element modeling demonstrate that the nanofibrillar structure of the aSi helices allows for 2 orders of magnitude faster effective rates for Li diffusion (D0 = 10–10 cm2/s) compared to solid aSi nanowires, while also averting fragmentation during lithiation. More importantly, it is shown that specific helical geometries can accommodate large, lithium-induced, volumetric expansions without shape distortion. A major advantage of the helical nanostructures is that the compressive force generated due to lithiation-induced expansion is an order of magnitude smaller than in straight nanocolumns that permanently buckle during lithiation. Thus, GLAD-fabricated films composed of dense periodic microscale helices with properly designed coil geometries are highly suitable for robust, high-capacity Li+ anodes.