RTRajendra Tiruchelvarayan

Rajendra Tiruchelvarayan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rajendra Tiruchelvarayan has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • HuaBI Ng

    Department of Neurosurgery, National Neuroscience Institute of Singapore, 11 Jalan Tan Tock Seng, 308433, Singapore

    1 shared publication
  • JiMin Ling

    Department of Neurosurgery, National Neuroscience Institute of Singapore, 11 Jalan Tan Tock Seng, 308433, Singapore

    1 shared publication
  • WanT Seow

    Department of Neurosurgery, National Neuroscience Institute of Singapore, 11 Jalan Tan Tock Seng, 308433, Singapore

    1 shared publication

Latest Publications

  • Open Access

    Surgical treatment of adult and pediatric C1/C2 subluxation with intraoperative computed tomography guidance

    by Rajendra Tiruchelvarayan, JiMin Ling, WanT Seow, HuaBI Ng

    Surgical treatment of C1/C2 subluxation has evolved significantly over the past 2 decades, from the relatively simpler posterior wiring to more technically demanding instrumentations such as C1 lateral mass screws - C2 pedicle screws, C1/C2 transarticular screws, and occipital cervical fusion. Navigation with fluoroscopy is currently the standard of practice in most centers. However, fluoroscopy at this level carries several major drawbacks, such as blockage by the mandible and inability to produce axial images for assessment of the reduction of rotatory subluxation. The authors report a series of 21 patients with C1/C2 subluxation treated surgically with intraoperative computed tomography (ICT) guidance. There were 7 children and 14 adults. Eight patients underwent C1/C2 fixation with a Harm's construct, and 13 patients underwent occipital cervical fusion. One out of 17 (6%) C1 lateral mass screws has breached the medial wall of lateral mass by 1 mm. Two out of 20 (10%) C2 pedicle screws have breached the foramen transversarium by 1 mm (Neo classification grade 1). The position of all subaxial screws (49 lateral mass screws and 13 pedicle screws) and occipital screws (50 screws) appeared satisfactory. No neurovascular damage occurred in all the patients. Ninety eight percent of the screws were placed in ideal position with the aid of ICT. Only 2% of the screws deviated from the planned position, but the breaches were not clinically significant and hence no revision was required. This showed that ICT guidance can help to achieve a high accuracy of surgical instrumentation for the treatment of C1/C2 subluxation.