Hna Al Nahedh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hna Al Nahedh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
As Alayad
Abdullah S Alayad, BDS, CAGS, MSD, DScD, College of Dentistry, Department of Restorative Dental Sciences, King Saud University, Riyadh, Saudi Arabia
1 shared publicationDf Al-Senan
Dana F Al-Senan, BDS, MSD, College of Dentistry, Clinical Dental Sciences Department, Princess Nourah University, Riyadh, Saudi Arabia
1 shared publication- Loulwa M. Al-Saud
School of Dentistry, University of Leeds, Leeds, West Yorkshire, UK
1 shared publication Nasrien Ateyah
1 shared publicationNn Shono
King Saud University, Riyadh, Saudi Arabia
1 shared publicationNs Sibai
Norah S Sibai, BDS, MSD, King Saud University, Restorative Dental Sciences, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- 1 July 2022
- Published by Operative Dentistry in Operative Dentistry
- Vol. 47 (4) , E197-E210
The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials
SUMMARY: Problem Statement: In an average class II posterior preparation, the curing light tip is placed at a distance from the restoration surface that far exceeds the 1-mm manufacturer’s recommendation. This distance can have potentially detrimental effects on the curing efficiency of the light-curing unit as well as the properties of the resin-based composite restoration, especially at the bottom of the cavity preparation. Purpose: The purpose of this study was to evaluate the effects of various types of light-curing units (LCUs) and the different curing distances on the degree of conversion (DC) and the surface hardness of bulk-fill composite materials. Methods and Materials: A total of 390 specimens of three resin-based composites (RBCs) were fabricated. Two bulk-fill RBCs, including Filtek Bulk Fill Posterior (3M ESPE GmbH, Seefeld, Germany) and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein), as well as a Filtek Z350 XT nano-filled composite (3M ESPE GmbH, Seefeld, Germany), were utilized. In this study, the Vickers microhardness number (VMN) and the DC were evaluated at 2 and 4 mm thicknesses. Polymerization for 20 seconds was performed using two high-power light-curing units, namely the polywave Bluephase G2 light-emitting diode (LED) LCU (Ivoclar Vivadent AG, Schaan, Liechtenstein) and the monowave Elipar Deep Cure S LED LCU (3M Oral Care, St Paul, MN, USA) at 0, 2, and 4 mm distance between the curing tip and the RBC surface. The results were analyzed using the two-way analysis of variance method. Scheffe’s post-hoc multiple comparison tests were used to determine significant differences between the materials, the LCU, and the tip distances. Results: The highest DC (70.17) was shown by Filtek Bulk Fill Posterior at a distance of 0 mm, whereas the lowest DC (45.99) was measured for the conventional Filtek Z350 XT at a 4 mm distance. Moreover, higher VMNs were shown by Filtek Bulk Fill and Filtek Z350 composites at 0 mm distance than by the Tetric N-Ceram Bulk Fill composite material when cured with a Bluephase G2 LCU. For all materials, a significant decrease in the DC and mean VMN values was observed at a 4 mm distance in comparison with 0 and 2 mm distances. Conclusions: The DC and VMN values among the studied bulk fill materials were more significantly affected by the material composition and curing protocols. The increased distance from the light tip has a detrimental effect on the mechanical properties of composite resin materials. Significant differences were observed in the curing efficiency of the two LCUs investigated.
- 1 July 2022
- Published by Operative Dentistry in Operative Dentistry
- Vol. 47 (4) , E197-E210
The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials
SUMMARY: Problem Statement: In an average class II posterior preparation, the curing light tip is placed at a distance from the restoration surface that far exceeds the 1-mm manufacturer’s recommendation. This distance can have potentially detrimental effects on the curing efficiency of the light-curing unit as well as the properties of the resin-based composite restoration, especially at the bottom of the cavity preparation. Purpose: The purpose of this study was to evaluate the effects of various types of light-curing units (LCUs) and the different curing distances on the degree of conversion (DC) and the surface hardness of bulk-fill composite materials. Methods and Materials: A total of 390 specimens of three resin-based composites (RBCs) were fabricated. Two bulk-fill RBCs, including Filtek Bulk Fill Posterior (3M ESPE GmbH, Seefeld, Germany) and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein), as well as a Filtek Z350 XT nano-filled composite (3M ESPE GmbH, Seefeld, Germany), were utilized. In this study, the Vickers microhardness number (VMN) and the DC were evaluated at 2 and 4 mm thicknesses. Polymerization for 20 seconds was performed using two high-power light-curing units, namely the polywave Bluephase G2 light-emitting diode (LED) LCU (Ivoclar Vivadent AG, Schaan, Liechtenstein) and the monowave Elipar Deep Cure S LED LCU (3M Oral Care, St Paul, MN, USA) at 0, 2, and 4 mm distance between the curing tip and the RBC surface. The results were analyzed using the two-way analysis of variance method. Scheffe’s post-hoc multiple comparison tests were used to determine significant differences between the materials, the LCU, and the tip distances. Results: The highest DC (70.17) was shown by Filtek Bulk Fill Posterior at a distance of 0 mm, whereas the lowest DC (45.99) was measured for the conventional Filtek Z350 XT at a 4 mm distance. Moreover, higher VMNs were shown by Filtek Bulk Fill and Filtek Z350 composites at 0 mm distance than by the Tetric N-Ceram Bulk Fill composite material when cured with a Bluephase G2 LCU. For all materials, a significant decrease in the DC and mean VMN values was observed at a 4 mm distance in comparison with 0 and 2 mm distances. Conclusions: The DC and VMN values among the studied bulk fill materials were more significantly affected by the material composition and curing protocols. The increased distance from the light tip has a detrimental effect on the mechanical properties of composite resin materials. Significant differences were observed in the curing efficiency of the two LCUs investigated.
- 1 March 2020
- Published by Operative Dentistry in Operative Dentistry
- Vol. 45 (2) , E43-E56
Fracture Resistance and Marginal Adaptation of Capped and Uncapped Bulk-fill Resin-based Materials
SUMMARY: Objectives: This study tested the fracture resistance of capped and uncapped bulk-fill composite restorations and compared them to a conventional composite. Also, the effect of different radiant exposure was investigated. Methods and Materials: Flowable and high-viscosity bulk-fill composites (SureFil SDR, Filtek Bulk-Fill Posterior, and Tetric N-Ceram Bulk-Fill) and a nanohybrid resin composite (Filtek Z350 XT) were used. Standardized class II cavities were prepared on extracted premolars, and different restoration protocols were used. In protocol 1 (control), restoration was applied using a layering technique; in protocol 2, restoration was applied in bulk with a capping layer; in protocol 3, restoration was applied in bulk without a capping layer; and in protocol 4, restoration was applied in bulk without a capping layer, and the light curing time was extended. After thermocycling, the restorations were examined for marginal gaps and then subjected to the fracture resistance test using a universal testing machine. Statistical analysis was carried out using two-way analysis of variance (ANOVA) followed by one-way ANOVA at a significance level of α = 0.05. Results: A statistically significant difference in the fracture resistance of the tested materials and protocols was detected. Filtek Bulk-Fill Posterior achieved the highest fracture resistance values regardless of the protocol used, and its results were comparable to those of Filtek Z350. SDR and Tetric N-Ceram Bulk-Fill achieved their highest strengths when a capping layer was added. Tetric N-Ceram Bulk-Fill showed improvement in fracture resistance with extended light curing, while SDR and Tetric N-Ceram Bulk-Fill achieved similar results with the addition of a capping layer. The uncapped bulk-fill group showed more gap-free margins than the capped group. Conclusion: The new high-viscosity bulk-fill composite restorations seem to have adequate fracture resistance. However, the results are material dependent, and some materials perform better with a capping layer and extended light curing.
- 1 March 2020
- Published by Operative Dentistry in Operative Dentistry
- Vol. 45 (2) , E43-E56
Fracture Resistance and Marginal Adaptation of Capped and Uncapped Bulk-fill Resin-based Materials
SUMMARY: Objectives: This study tested the fracture resistance of capped and uncapped bulk-fill composite restorations and compared them to a conventional composite. Also, the effect of different radiant exposure was investigated. Methods and Materials: Flowable and high-viscosity bulk-fill composites (SureFil SDR, Filtek Bulk-Fill Posterior, and Tetric N-Ceram Bulk-Fill) and a nanohybrid resin composite (Filtek Z350 XT) were used. Standardized class II cavities were prepared on extracted premolars, and different restoration protocols were used. In protocol 1 (control), restoration was applied using a layering technique; in protocol 2, restoration was applied in bulk with a capping layer; in protocol 3, restoration was applied in bulk without a capping layer; and in protocol 4, restoration was applied in bulk without a capping layer, and the light curing time was extended. After thermocycling, the restorations were examined for marginal gaps and then subjected to the fracture resistance test using a universal testing machine. Statistical analysis was carried out using two-way analysis of variance (ANOVA) followed by one-way ANOVA at a significance level of α = 0.05. Results: A statistically significant difference in the fracture resistance of the tested materials and protocols was detected. Filtek Bulk-Fill Posterior achieved the highest fracture resistance values regardless of the protocol used, and its results were comparable to those of Filtek Z350. SDR and Tetric N-Ceram Bulk-Fill achieved their highest strengths when a capping layer was added. Tetric N-Ceram Bulk-Fill showed improvement in fracture resistance with extended light curing, while SDR and Tetric N-Ceram Bulk-Fill achieved similar results with the addition of a capping layer. The uncapped bulk-fill group showed more gap-free margins than the capped group. Conclusion: The new high-viscosity bulk-fill composite restorations seem to have adequate fracture resistance. However, the results are material dependent, and some materials perform better with a capping layer and extended light curing.
- 1 November 2017
- Published by Operative Dentistry in Operative Dentistry
- Vol. 42 (6) , 658-668
Evaluation of Interfacial Gap Volume of Two Low-shrinkage Composites Using Micro–Computed Tomography
Objectives: To investigate the efficacy of X-ray micro–computed tomography (μCT) in the detection and quantification of interfacial gap formation in standardized Class I and Class II resin composite restorations, to compare the interfacial gaps for two low-shrinkage resin composites with a methacrylate composite material, and to determine any correlation between the cavity configuration factor (C-factor) and the volume of gaps formed. Methods and Materials: Sixty standardized Class I and Class II cavities were prepared and divided into six groups. Three types of composites, with their recommended self-etching adhesive systems, were used: Filtek Z250 XT; Estelite Sigma Quick; and Filtek P90. Each of the composite materials was placed in 10 Class I and 10 Class II cavities. The specimens were digitized using Skyscan 1172 μCT. They were examined for gap volume measurements, the thickness of the adhesive layer, and location of interfacial gaps. Results: There was a significant difference in the mean gap volume percentages of the three materials. The gap volume percent of Estelite Sigma quick was significantly lower than that of Filtek P90. No significant difference in the mean gap volume percentages of Class I and Class II restorations was found, except for Estelite Sigma Quick, in which the Class I gap volume percentage was higher than that of the Class II restorations. Conclusions: μCT is an efficacious tool for the measurement of volumetric gaps formed at the tooth/restoration interface and for the evaluation of the adhesive layer. The differences in the C-factor do not always have a pronounced effect on the gap volumes of low-shrinkage composites.
- 1 November 2017
- Published by Operative Dentistry in Operative Dentistry
- Vol. 42 (6) , 658-668
Evaluation of Interfacial Gap Volume of Two Low-shrinkage Composites Using Micro–Computed Tomography
Objectives: To investigate the efficacy of X-ray micro–computed tomography (μCT) in the detection and quantification of interfacial gap formation in standardized Class I and Class II resin composite restorations, to compare the interfacial gaps for two low-shrinkage resin composites with a methacrylate composite material, and to determine any correlation between the cavity configuration factor (C-factor) and the volume of gaps formed. Methods and Materials: Sixty standardized Class I and Class II cavities were prepared and divided into six groups. Three types of composites, with their recommended self-etching adhesive systems, were used: Filtek Z250 XT; Estelite Sigma Quick; and Filtek P90. Each of the composite materials was placed in 10 Class I and 10 Class II cavities. The specimens were digitized using Skyscan 1172 μCT. They were examined for gap volume measurements, the thickness of the adhesive layer, and location of interfacial gaps. Results: There was a significant difference in the mean gap volume percentages of the three materials. The gap volume percent of Estelite Sigma quick was significantly lower than that of Filtek P90. No significant difference in the mean gap volume percentages of Class I and Class II restorations was found, except for Estelite Sigma Quick, in which the Class I gap volume percentage was higher than that of the Class II restorations. Conclusions: μCT is an efficacious tool for the measurement of volumetric gaps formed at the tooth/restoration interface and for the evaluation of the adhesive layer. The differences in the C-factor do not always have a pronounced effect on the gap volumes of low-shrinkage composites.
- Open Access
- 1 April 2013
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 25 (2) , 61-67
The effectiveness of four methods for stain removal from direct resin-based composite restorative materials
Read the latest articles of The Saudi Dental Journal at ScienceDirect.com, Elsevier’s leading platform of peer-reviewed scholarly literature
- 1 April 2013
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 25 (2) , 61-67
Open AccessThe effectiveness of four methods for stain removal from direct resin-based composite restorative materials
Read the latest articles of The Saudi Dental Journal at ScienceDirect.com, Elsevier’s leading platform of peer-reviewed scholarly literature
- 1 July 2012
- Published by Operative Dentistry in Operative Dentistry
- Vol. 37 (4) , 340-355
Occluding Effect of Nd:YAG Laser and Different Dentin Desensitizing Agents on Human Dentinal Tubules In Vitro: A Scanning Electron Microscopy Investigation
SUMMARY: Objectives: This in vitro study aimed to microscopically evaluate and compare the occluding effect of the Nd:YAG laser and different dentin desensitizing agents on human dentinal tubules. Materials and Methods: The Nd:YAG laser (SunLase™ 800) and four commercially available and professionally applied dentin desensitizers (Gluma® desensitizer, Tenure Quick®, Quell™ desensitizer, and VivaSens®) were investigated in this study. Sixty-four extracted intact human molars were used. Each dentin surface was divided by shallow indentation into two halves, one of which was used for treatment and the other of which served as a control. The dentin surfaces were etched to remove any smear plugs and to mimic the open dentinal tubules of sensitive dentin using 0.5 M ethylenediaminetetraacetic acid (pH 7.4) for two minutes (applied with a microbrush) and then rinsed with an air-water syringe for 30 seconds. The laser samples (n=16) were randomly divided into four groups of four samples each. These groups were the step-up technique group, the 14-day group, the one-minute group, and the two-minute group. Forty-eight samples were treated with the four tested desensitizing agents and were randomly divided into four groups (n=12/group). Each group was further subdivided into three subgroups (n=4). Samples of the first subgroup were treated for 14 days, while those of the second subgroup were treated once. Samples of the last subgroup were fractured longitudinally after a single treatment. All of the samples were then examined under a scanning electron microscope. Results: The Nd:YAG laser–irradiated dentin showed reduction or complete obliteration of the dentinal tubule lumen; thus, the treatment modified the original dentinal structure. The lased dentin surface in the two-minute group showed bubble-like changes in the area of the dentinal tubules' orifices. Statistically, the two-minute group was found to have a significantly higher percentage of partially or fully occluded tubules than did the one-minute group. All of the studied desensitizing agents produced occlusion of the dentinal tubules; however, the appearance of the precipitates, the level of coverage, and the degree of dentinal occlusion varied among the tested products. Conclusion: Throughout the specified period of this study, occlusion and/or narrowing of the open dentinal tubules have been successfully achieved with both treatment approaches.
- 1 July 2012
- Published by Operative Dentistry in Operative Dentistry
- Vol. 37 (4) , 340-355
Occluding Effect of Nd:YAG Laser and Different Dentin Desensitizing Agents on Human Dentinal Tubules In Vitro: A Scanning Electron Microscopy Investigation
SUMMARY: Objectives: This in vitro study aimed to microscopically evaluate and compare the occluding effect of the Nd:YAG laser and different dentin desensitizing agents on human dentinal tubules. Materials and Methods: The Nd:YAG laser (SunLase™ 800) and four commercially available and professionally applied dentin desensitizers (Gluma® desensitizer, Tenure Quick®, Quell™ desensitizer, and VivaSens®) were investigated in this study. Sixty-four extracted intact human molars were used. Each dentin surface was divided by shallow indentation into two halves, one of which was used for treatment and the other of which served as a control. The dentin surfaces were etched to remove any smear plugs and to mimic the open dentinal tubules of sensitive dentin using 0.5 M ethylenediaminetetraacetic acid (pH 7.4) for two minutes (applied with a microbrush) and then rinsed with an air-water syringe for 30 seconds. The laser samples (n=16) were randomly divided into four groups of four samples each. These groups were the step-up technique group, the 14-day group, the one-minute group, and the two-minute group. Forty-eight samples were treated with the four tested desensitizing agents and were randomly divided into four groups (n=12/group). Each group was further subdivided into three subgroups (n=4). Samples of the first subgroup were treated for 14 days, while those of the second subgroup were treated once. Samples of the last subgroup were fractured longitudinally after a single treatment. All of the samples were then examined under a scanning electron microscope. Results: The Nd:YAG laser–irradiated dentin showed reduction or complete obliteration of the dentinal tubule lumen; thus, the treatment modified the original dentinal structure. The lased dentin surface in the two-minute group showed bubble-like changes in the area of the dentinal tubules' orifices. Statistically, the two-minute group was found to have a significantly higher percentage of partially or fully occluded tubules than did the one-minute group. All of the studied desensitizing agents produced occlusion of the dentinal tubules; however, the appearance of the precipitates, the level of coverage, and the degree of dentinal occlusion varied among the tested products. Conclusion: Throughout the specified period of this study, occlusion and/or narrowing of the open dentinal tubules have been successfully achieved with both treatment approaches.
- 1 July 2012
- Published by Operative Dentistry in Operative Dentistry
- Vol. 37 (4) , 406-416
Contrast Ratio and Masking Ability of Three Ceramic Veneering Materials
SUMMARY: Statement of the Problem: Porcelain veneer materials are translucent and are therefore affected by their thickness as well as the color of the underlying substructure, which limits their masking ability and compromises the esthetic result in heavily stained teeth.Purpose: The purpose of this study was to compare the contrast ratio (CR) and masking ability of three different veneering ceramics with two thicknesses by measuring the color differences over white and black backgrounds. Correlations between CR and masking ability of these veneering ceramics were evaluated.Methods and Materials: A total of 30 disc-shaped specimens (12 mm diameter × 1.0 mm or 1.5 mm) were fabricated in shade A2 from three types of all-ceramic systems: IPS e.max Press (IPSe; Ivoclar Vivadent, Schaan, Liechtensein), Vita VM7 (VM7; VITA Zahnfabrik, Bad Säckingen, Germany), and Nobel Rondo Press Alumina: Solo (NRPA; Nobel Biocare, Zürich-Flughafen, Switzerland). The CR, defined as the ratio of illuminance (Y) of the test material when placed on the black background (Yb) to the illuminance of the same material when placed over a white background (Yw), was determined (CR=Yb/Yw). The color (CIE L*a*b*) and Y of each specimen were measured over standard white and black tiles using a spectrophotometer (ColorEye 7000 A, Model C6, GretagMacbeth, New Windsor, NY, USA). Masking abilities of the specimens were determined by measuring the color difference (ΔE) over white and black backgrounds. Both CR and ΔE data were analyzed using two-way analysis of variance (ANOVA). One-way ANOVA was used to compare the mean values of CR across the three materials followed by the Duncan multiple comparison test. The correlations between CR and ΔE were determined by comparing R2 values obtained from a linear regression analysis. A Student t-test for independent samples was used to compare the mean contrast ratio and ΔE values for the two thicknesses.Results: CR values of NRPA were significantly less than those of IPSe and VM7, and the CR of IPSe was higher than that of VM7. Furthermore, CR increased as the thickness of the discs increased to 1.5 mm for all three materials. Mean ΔE values were significantly higher with 1.0-mm-thick discs than with 1.5-mm discs. Among the three materials it was observed that NRPA had the highest ΔE when compared with IPSe or VM7, whereas the ΔE of the latter two were not significantly different from one another. There was a strong linear correlation between CR and masking ability.Conclusion: CR and masking ability are affected by the type as well as the thickness of the ceramic used. IPSe and VM7 are similar in their masking abilities, whereas NRPA had the lowest masking ability. NRPA was the most translucent, followed by VM7; IPSe was the most opaque. None of the materials tested was able to completely mask the black background. It is therefore recommended that the type of ceramic should be chosen according to each clinical situation.
- 1 July 2012
- Published by Operative Dentistry in Operative Dentistry
- Vol. 37 (4) , 406-416
Contrast Ratio and Masking Ability of Three Ceramic Veneering Materials
SUMMARY: Statement of the Problem: Porcelain veneer materials are translucent and are therefore affected by their thickness as well as the color of the underlying substructure, which limits their masking ability and compromises the esthetic result in heavily stained teeth.Purpose: The purpose of this study was to compare the contrast ratio (CR) and masking ability of three different veneering ceramics with two thicknesses by measuring the color differences over white and black backgrounds. Correlations between CR and masking ability of these veneering ceramics were evaluated.Methods and Materials: A total of 30 disc-shaped specimens (12 mm diameter × 1.0 mm or 1.5 mm) were fabricated in shade A2 from three types of all-ceramic systems: IPS e.max Press (IPSe; Ivoclar Vivadent, Schaan, Liechtensein), Vita VM7 (VM7; VITA Zahnfabrik, Bad Säckingen, Germany), and Nobel Rondo Press Alumina: Solo (NRPA; Nobel Biocare, Zürich-Flughafen, Switzerland). The CR, defined as the ratio of illuminance (Y) of the test material when placed on the black background (Yb) to the illuminance of the same material when placed over a white background (Yw), was determined (CR=Yb/Yw). The color (CIE L*a*b*) and Y of each specimen were measured over standard white and black tiles using a spectrophotometer (ColorEye 7000 A, Model C6, GretagMacbeth, New Windsor, NY, USA). Masking abilities of the specimens were determined by measuring the color difference (ΔE) over white and black backgrounds. Both CR and ΔE data were analyzed using two-way analysis of variance (ANOVA). One-way ANOVA was used to compare the mean values of CR across the three materials followed by the Duncan multiple comparison test. The correlations between CR and ΔE were determined by comparing R2 values obtained from a linear regression analysis. A Student t-test for independent samples was used to compare the mean contrast ratio and ΔE values for the two thicknesses.Results: CR values of NRPA were significantly less than those of IPSe and VM7, and the CR of IPSe was higher than that of VM7. Furthermore, CR increased as the thickness of the discs increased to 1.5 mm for all three materials. Mean ΔE values were significantly higher with 1.0-mm-thick discs than with 1.5-mm discs. Among the three materials it was observed that NRPA had the highest ΔE when compared with IPSe or VM7, whereas the ΔE of the latter two were not significantly different from one another. There was a strong linear correlation between CR and masking ability.Conclusion: CR and masking ability are affected by the type as well as the thickness of the ceramic used. IPSe and VM7 are similar in their masking abilities, whereas NRPA had the lowest masking ability. NRPA was the most translucent, followed by VM7; IPSe was the most opaque. None of the materials tested was able to completely mask the black background. It is therefore recommended that the type of ceramic should be chosen according to each clinical situation.
- 1 September 2006
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 7 (4) , 9-16
Effect of Different Bonding Conditions on the Shear Bond Strength of Two Compomers to Bovine Dentin
Aim: Despite the improvements to compomer materials, the bond strength of these materials remains inferior to .composite/resin bonding. systems and limits their clinical use. The purpose of this study was to evaluate the effect of acidic conditioning with phosphoric acid and Prompt L-Pop (PLP) on the shear bond strength of two compomers Dyract AP (DAP) and Composan Glass (CG) to dentin. Methods and Materials: Sixty extracted bovine teeth were used to test the shear bond strength of two compomers to flat dentin labial surfaces. The dentin specimens were randomly assigned to six groups of ten specimens each: Group 1: DAP and Prime & Bond NT (PBNT); Group 2: DAP/PBNT with a 15 second dentin etch prior to bonding; Group 3: DAP placed with PLP adhesive; Group 4: CG and Compobond NE (CBNE); Group 5: CG/CBNE with a 15 second dentin etch; and Group 6: CG placed with PLP adhesive. The specimens were stored at 37°C with 100% humidity for 24 hours then mounted and sheared using an Instron Universal Testing Machine at a cross head speed of 0.5 mm/min. The results were recorded in Mega Pascals (MPa). The sheared specimens were examined under a light microscope, and the type of failure (adhesive, cohesive, or mixed) was recorded. Results: The mean dentin shear bond strength value (MPa) for the groups was: Group 1 (11.6±3.9); Group 2 (13.2±3.3); Group 3 (12.4±2.0); Group 4 (13.0±4.3); Group 5 (19.3±3.7); and Group 6 (13.1±3.0). One way analysis of variance (ANOVA) and Tukey HSD post-hoc tests detected a significantly higher bond strength (P ≤ 0.003) for group 5. For groups 1, 3, 4, and 6, the mode of failure was mostly adhesive. When acid etching of dentin was performed (groups 2 and 5), cohesive fracture within dentin was the predominant mode of failure. Acid etching and the use of PLP significantly reduced the number of adhesive fractures and reduced variability in the shear bond strength results. Conclusions: Acid etching significantly increased the shear bond strength of CG to dentin but did not affect DAP. The application of PLP resulted in a shear bond strength not statistically different from PBNT or CPNE. CG bond to dentin is improved with acid etching using phosphoric acid. However, PLP provided no significant improvement in the shear bond strength of DAP and CG. Citation: Al-Nahedh H, Ateyah N. Effect of Different Bonding Conditions on the Shear Bond Strength of Two Compomers to Bovine Dentin. J Contemp Dent Pract 2006 September;(7)4:009-016.
- 1 September 2006
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 7 (4) , 9-16
Effect of Different Bonding Conditions on the Shear Bond Strength of Two Compomers to Bovine Dentin
Aim: Despite the improvements to compomer materials, the bond strength of these materials remains inferior to .composite/resin bonding. systems and limits their clinical use. The purpose of this study was to evaluate the effect of acidic conditioning with phosphoric acid and Prompt L-Pop (PLP) on the shear bond strength of two compomers Dyract AP (DAP) and Composan Glass (CG) to dentin. Methods and Materials: Sixty extracted bovine teeth were used to test the shear bond strength of two compomers to flat dentin labial surfaces. The dentin specimens were randomly assigned to six groups of ten specimens each: Group 1: DAP and Prime & Bond NT (PBNT); Group 2: DAP/PBNT with a 15 second dentin etch prior to bonding; Group 3: DAP placed with PLP adhesive; Group 4: CG and Compobond NE (CBNE); Group 5: CG/CBNE with a 15 second dentin etch; and Group 6: CG placed with PLP adhesive. The specimens were stored at 37°C with 100% humidity for 24 hours then mounted and sheared using an Instron Universal Testing Machine at a cross head speed of 0.5 mm/min. The results were recorded in Mega Pascals (MPa). The sheared specimens were examined under a light microscope, and the type of failure (adhesive, cohesive, or mixed) was recorded. Results: The mean dentin shear bond strength value (MPa) for the groups was: Group 1 (11.6±3.9); Group 2 (13.2±3.3); Group 3 (12.4±2.0); Group 4 (13.0±4.3); Group 5 (19.3±3.7); and Group 6 (13.1±3.0). One way analysis of variance (ANOVA) and Tukey HSD post-hoc tests detected a significantly higher bond strength (P ≤ 0.003) for group 5. For groups 1, 3, 4, and 6, the mode of failure was mostly adhesive. When acid etching of dentin was performed (groups 2 and 5), cohesive fracture within dentin was the predominant mode of failure. Acid etching and the use of PLP significantly reduced the number of adhesive fractures and reduced variability in the shear bond strength results. Conclusions: Acid etching significantly increased the shear bond strength of CG to dentin but did not affect DAP. The application of PLP resulted in a shear bond strength not statistically different from PBNT or CPNE. CG bond to dentin is improved with acid etching using phosphoric acid. However, PLP provided no significant improvement in the shear bond strength of DAP and CG. Citation: Al-Nahedh H, Ateyah N. Effect of Different Bonding Conditions on the Shear Bond Strength of Two Compomers to Bovine Dentin. J Contemp Dent Pract 2006 September;(7)4:009-016.