Daisuke Yamazaki
Daisuke Yamazaki has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Mitsunori Yuzurihara
Department of Cardiology, Akita Cerebrospinal and Cardiovascular Center, Japan
5 shared publicationsHirokazu Amamizu
Department of Cardiology, Akita Cerebrospinal and Cardiovascular Center, Akita, Japan
3 shared publicationsTakahide Fujihashi
Department of Cardiology, Akita Cerebrospinal and Cardiovascular Center, Akita, Japan
3 shared publicationsToru Takahashi
Department of Cardiology, Akita Cerebrospinal and Cardiovascular Center, Akita, Japan
3 shared publicationsFumiaki Sasaki
Department of Radiology, Akita Cerebrospinal and Cardiovascular Center, Japan
2 shared publications- Chao Liu
State Key Laboratory for Critical Mineral Research and Exploration Institute of Geochemistry Chinese Academy of Science Guiyang P. R. China
1 shared publication
Latest Publications
- Open Access
- 22 February 2026
- Published by Wiley in Clinical Case Reports
- Vol. 14 (3) , e72069
A Case of Tricuspid Valve and Papillary Muscle Rupture Due to Entrapment of the Tendon of the Tricuspid Valve by the PENTARAY TM Catheter
When using multipolar mapping catheters for catheter ablation, take care to pass through the central portion when crossing the valve annulus or chordae tendineae, and avoid applying torque as much as possible.
- 22 February 2026
- Published by Wiley in Clinical Case Reports
- Vol. 14 (3) , e72069
Open AccessA Case of Tricuspid Valve and Papillary Muscle Rupture Due to Entrapment of the Tendon of the Tricuspid Valve by the PENTARAY TM Catheter
When using multipolar mapping catheters for catheter ablation, take care to pass through the central portion when crossing the valve annulus or chordae tendineae, and avoid applying torque as much as possible.
- Open Access
- 4 September 2025
- Published by Springer Nature in Cureus
- Vol. 17 (9) , e91627
Lead Advancement Using Only a Stylet-Driven Lead and Stylet Without a Delivery Catheter: Aiming for Left Bundle Branch Area Pacing Without a Guiding Catheter
Background: Left bundle branch area pacing (LBBAP) using a delivery catheter has become popular for achieving physiologic pacing, since lead advancement requires backup support, which is usually provided by a delivery catheter. However, traditional stylet shaping offers the advantage of flexible pacing site selection. Therefore, in this study, we investigated whether LBBAP can be performed using traditional stylet shaping. Methods: We retrospectively reviewed 12 cases at our institution that underwent pacemaker implantation without using a delivery catheter, aiming to achieve LBBAP. Right ventricular (RV) angiography was performed, and the pacing site was selected using a conventional three-dimensional (3D) shaping stylet in the central region of the right ventricle, which was divided into nine segments, targeting a stimulated left ventricular activation time (LVAT) ≤ 80 ms. Next, we switched to a two-dimensional (2D) shaping stylet to achieve passive backup and performed lead advancement by rotating the lead body without pushing the stylet. We compared the LVAT, QRS width, and lead parameters over time. Results: LVAT was significantly shortened from helix deployment (77.2 ± 10.7 ms) to body turn (71.5 ± 13.2 ms) (p = 0.00016) and further shortened by one week (62.5 ± 13.6 ms) (p = 0.0022). Conclusions: By modifying the stylet-shaping curve and technique, lead advancement into the myocardium was feasible without using a delivery catheter. Although this study did not meet the strict criteria for LBBAP, our findings suggest that catheter-free LBBAP may be achievable with refined stylet shaping and standardized techniques.
- 4 September 2025
- Published by Springer Nature in Cureus
- Vol. 17 (9) , e91627
Open AccessLead Advancement Using Only a Stylet-Driven Lead and Stylet Without a Delivery Catheter: Aiming for Left Bundle Branch Area Pacing Without a Guiding Catheter
Background: Left bundle branch area pacing (LBBAP) using a delivery catheter has become popular for achieving physiologic pacing, since lead advancement requires backup support, which is usually provided by a delivery catheter. However, traditional stylet shaping offers the advantage of flexible pacing site selection. Therefore, in this study, we investigated whether LBBAP can be performed using traditional stylet shaping. Methods: We retrospectively reviewed 12 cases at our institution that underwent pacemaker implantation without using a delivery catheter, aiming to achieve LBBAP. Right ventricular (RV) angiography was performed, and the pacing site was selected using a conventional three-dimensional (3D) shaping stylet in the central region of the right ventricle, which was divided into nine segments, targeting a stimulated left ventricular activation time (LVAT) ≤ 80 ms. Next, we switched to a two-dimensional (2D) shaping stylet to achieve passive backup and performed lead advancement by rotating the lead body without pushing the stylet. We compared the LVAT, QRS width, and lead parameters over time. Results: LVAT was significantly shortened from helix deployment (77.2 ± 10.7 ms) to body turn (71.5 ± 13.2 ms) (p = 0.00016) and further shortened by one week (62.5 ± 13.6 ms) (p = 0.0022). Conclusions: By modifying the stylet-shaping curve and technique, lead advancement into the myocardium was feasible without using a delivery catheter. Although this study did not meet the strict criteria for LBBAP, our findings suggest that catheter-free LBBAP may be achievable with refined stylet shaping and standardized techniques.
- Open Access
- 4 May 2025
- Published by Springer Nature in Cureus
- Vol. 17 (5) , e83474
An Anterolateral Popliteal Artery Puncture Resulting in an Arteriovenous Fistula Involving Three Vessels: Bail Out by Balloon Hemostasis
The anterolateral popliteal artery (PA) puncture technique is mainly used during endovascular therapy of the superficial femoral artery when antegrade wiring fails to pass the wire through the true lumen of the distal artery. This method has many advantages, such as allowing puncture while the patient is in the supine position and relatively easy hemostasis; however, the distance from the body surface to the PA is long, and puncture requires practice. In this case, the distal artery approach was performed for the treatment of chronic occlusive lesions in the left superficial femoral artery. We performed anterolateral PA puncture, inserted a 4.0-Fr sheath, and successfully achieved revascularization using a controlled antegrade and retrograde tracking (CART) technique. Post-procedural angiography after sheath removal revealed an arteriovenous fistula between the fibular artery and fibular vein and another arteriovenous fistula between the fibular artery and the anterior tibial vein. After adding two 10-minute balloon hemostasis, the arteriovenous shunt almost disappeared, and there was no recurrence of the arteriovenous shunt thereafter. The patient has been an outpatient for four years with no recurrence of arteriovenous shunts. Repeated punctures due to inexperience with anterolateral PA puncture and the insertion of a sheath at a low peripheral site may increase the risk of arteriovenous fistula. Becoming skilled at puncture and puncturing the PA at the height of the fibular head can reduce the risk of arteriovenous fistula.
- 4 May 2025
- Published by Springer Nature in Cureus
- Vol. 17 (5) , e83474
Open AccessAn Anterolateral Popliteal Artery Puncture Resulting in an Arteriovenous Fistula Involving Three Vessels: Bail Out by Balloon Hemostasis
The anterolateral popliteal artery (PA) puncture technique is mainly used during endovascular therapy of the superficial femoral artery when antegrade wiring fails to pass the wire through the true lumen of the distal artery. This method has many advantages, such as allowing puncture while the patient is in the supine position and relatively easy hemostasis; however, the distance from the body surface to the PA is long, and puncture requires practice. In this case, the distal artery approach was performed for the treatment of chronic occlusive lesions in the left superficial femoral artery. We performed anterolateral PA puncture, inserted a 4.0-Fr sheath, and successfully achieved revascularization using a controlled antegrade and retrograde tracking (CART) technique. Post-procedural angiography after sheath removal revealed an arteriovenous fistula between the fibular artery and fibular vein and another arteriovenous fistula between the fibular artery and the anterior tibial vein. After adding two 10-minute balloon hemostasis, the arteriovenous shunt almost disappeared, and there was no recurrence of the arteriovenous shunt thereafter. The patient has been an outpatient for four years with no recurrence of arteriovenous shunts. Repeated punctures due to inexperience with anterolateral PA puncture and the insertion of a sheath at a low peripheral site may increase the risk of arteriovenous fistula. Becoming skilled at puncture and puncturing the PA at the height of the fibular head can reduce the risk of arteriovenous fistula.
- Open Access
- 1 May 2025
- Published by Wiley
A case of tricuspid valve and papillary muscle rupture due to entrapment of the tendon of the tricuspid valve by the PENTARAYⓇ catheter
- 1 May 2025
- Published by Wiley
Open AccessA case of tricuspid valve and papillary muscle rupture due to entrapment of the tendon of the tricuspid valve by the PENTARAYⓇ catheter
- 12 April 2025
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 80, 115-118
Anatomical merkmal method for anterolateral popliteal artery puncture technique: A prospective study
- 12 April 2025
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 80, 115-118
Anatomical merkmal method for anterolateral popliteal artery puncture technique: A prospective study
- Open Access
- 15 March 2025
- Published by Springer Nature in Cureus
- Vol. 17 (3) , e80621
Infected Pseudoaneurysm Associated With Umbilical Depression at the Puncture Site Due to Perclose ProStyle Suture®: Restoration for Infection Prevention
Percutaneous coronary intervention is now commonly performed using the transradial artery approach, but endovascular therapy (EVT) is still often performed via the femoral artery (FA). Vascular closure devices have been developed and are commonly used to achieve hemostasis at the FA puncture site. However, there have been some reports of infection complications associated with the use of vascular closure devices. When Perclose ProStyle Suture® (Abbott, Abbott Park, IL, USA) is used for hemostasis in thin patients, the puncture site may become umbilical depressed. We report three cases of umbilical puncture site depression with the Perclose ProStyle Suture®. Case 1 was a 78-year-old male with a body mass index (BMI) of 18 kg/m2 and a thin build who underwent EVT for peripheral arterial disease with rest pain. Stents were implanted in the stenosis of both external iliac arteries and the occluded lesion of the right superficial femoral artery (SFA) via the left FA approach. The puncture site was sutured with Perclose ProStyle Suture®, but the puncture site became depressed like a navel. One month later, he visited the hospital with pus discharge from the left FA puncture site, and one week later, he visited the hospital with bleeding from an infected pseudoaneurysm. Although vascular repair surgery was performed, it recurred a month later, and thus the infected tissue was debrided and vascularization was performed using a bovine pericardial patch. Case 2 was an 88-year-old female with a BMI of 18 kg/m2 who was thin and had intermittent claudication. EVT was performed on the occluded lesion in the left SFA. A stent was implanted in the left SFA via the right FA, and the puncture site was hemostatized with Perclose ProStyle Suture®. Two weeks later, she was referred to our institution because of bleeding from the puncture site in her right FA, and a contrast computed tomography revealed an infected pseudoaneurysm. She was referred to vascular surgery, where the infected area was debrided and vascular repair surgery was performed. Case 3 was a 72-year-old male (BMI 18.4 kg/m2) with intermittent claudication. EVT was performed for a severe stenosis lesion in the right SFA. A stent was implanted in the right SFA via the left FA approach, and the puncture site was hemostatized using Perclose ProStyle Suture®. The puncture site then became depressed like a navel. Based on the experience of cases 1 and 2, the subcutaneous tissue around the suture was incised, the suture was buried in the subcutaneous tissue, and the dermis was sutured with 5-0 absorbable sutures. The patient is being followed up as an outpatient, and there is no evidence of infection, and the condition is good. Due to the design of the device, the Perclose ProStyle Suture® is designed to suture approximately 1 cm proximal to the vessel wall. Therefore, in such cases, where the patient is thin and has thin subcutaneous tissue, the suture is placed close to the dermis, and when ligated, the dermis is depressed like a navel. When the suture is close to the dermis, the risk of vascular infection increases; therefore, it is preferable to perform the repair so that the suture is buried in the subcutaneous tissue.
- 15 March 2025
- Published by Springer Nature in Cureus
- Vol. 17 (3) , e80621
Open AccessInfected Pseudoaneurysm Associated With Umbilical Depression at the Puncture Site Due to Perclose ProStyle Suture®: Restoration for Infection Prevention
Percutaneous coronary intervention is now commonly performed using the transradial artery approach, but endovascular therapy (EVT) is still often performed via the femoral artery (FA). Vascular closure devices have been developed and are commonly used to achieve hemostasis at the FA puncture site. However, there have been some reports of infection complications associated with the use of vascular closure devices. When Perclose ProStyle Suture® (Abbott, Abbott Park, IL, USA) is used for hemostasis in thin patients, the puncture site may become umbilical depressed. We report three cases of umbilical puncture site depression with the Perclose ProStyle Suture®. Case 1 was a 78-year-old male with a body mass index (BMI) of 18 kg/m2 and a thin build who underwent EVT for peripheral arterial disease with rest pain. Stents were implanted in the stenosis of both external iliac arteries and the occluded lesion of the right superficial femoral artery (SFA) via the left FA approach. The puncture site was sutured with Perclose ProStyle Suture®, but the puncture site became depressed like a navel. One month later, he visited the hospital with pus discharge from the left FA puncture site, and one week later, he visited the hospital with bleeding from an infected pseudoaneurysm. Although vascular repair surgery was performed, it recurred a month later, and thus the infected tissue was debrided and vascularization was performed using a bovine pericardial patch. Case 2 was an 88-year-old female with a BMI of 18 kg/m2 who was thin and had intermittent claudication. EVT was performed on the occluded lesion in the left SFA. A stent was implanted in the left SFA via the right FA, and the puncture site was hemostatized with Perclose ProStyle Suture®. Two weeks later, she was referred to our institution because of bleeding from the puncture site in her right FA, and a contrast computed tomography revealed an infected pseudoaneurysm. She was referred to vascular surgery, where the infected area was debrided and vascular repair surgery was performed. Case 3 was a 72-year-old male (BMI 18.4 kg/m2) with intermittent claudication. EVT was performed for a severe stenosis lesion in the right SFA. A stent was implanted in the right SFA via the left FA approach, and the puncture site was hemostatized using Perclose ProStyle Suture®. The puncture site then became depressed like a navel. Based on the experience of cases 1 and 2, the subcutaneous tissue around the suture was incised, the suture was buried in the subcutaneous tissue, and the dermis was sutured with 5-0 absorbable sutures. The patient is being followed up as an outpatient, and there is no evidence of infection, and the condition is good. Due to the design of the device, the Perclose ProStyle Suture® is designed to suture approximately 1 cm proximal to the vessel wall. Therefore, in such cases, where the patient is thin and has thin subcutaneous tissue, the suture is placed close to the dermis, and when ligated, the dermis is depressed like a navel. When the suture is close to the dermis, the risk of vascular infection increases; therefore, it is preferable to perform the repair so that the suture is buried in the subcutaneous tissue.
- Open Access
- 24 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e79541
Rare Complication of Distal Radial Artery Puncture: Arteriovenous Fistula Formation Following Percutaneous Coronary Intervention
Distal radial artery puncture is increasingly utilized in percutaneous coronary intervention (PCI) due to its reduced complication rates compared to conventional approaches. However, arteriovenous fistula (AVF) formation, though rare, remains a potential complication. A 71-year-old man underwent PCI for effort angina of the left main trunk via a distal radial artery (RA) approach. Three years later, he underwent cardiac catheterization and lower limb arteriography for peripheral arterial disease with intermittent claudication. When palpation of the left RA was confirmed, an enlarged cephalic vein with thrill was observed. Ultrasonography revealed an arteriovenous fistula (AVF) with a diameter of 2.0 mm, and arteriography was performed during catheterization to diagnose AVF. Three years after the PCI, the distended cephalic vein was strongly distended, so vascular ligation was performed at another institution. Although a residual, unidentifiable arteriovenous shunt and a weak thrill persisted, the distended cephalic vein showed improvement, and the patient's condition remained favorable. Early detection of distal radial AVFs, potentially manageable by compression, underscores the importance of post-procedural vigilance in PCI patients.
- 24 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e79541
Open AccessRare Complication of Distal Radial Artery Puncture: Arteriovenous Fistula Formation Following Percutaneous Coronary Intervention
Distal radial artery puncture is increasingly utilized in percutaneous coronary intervention (PCI) due to its reduced complication rates compared to conventional approaches. However, arteriovenous fistula (AVF) formation, though rare, remains a potential complication. A 71-year-old man underwent PCI for effort angina of the left main trunk via a distal radial artery (RA) approach. Three years later, he underwent cardiac catheterization and lower limb arteriography for peripheral arterial disease with intermittent claudication. When palpation of the left RA was confirmed, an enlarged cephalic vein with thrill was observed. Ultrasonography revealed an arteriovenous fistula (AVF) with a diameter of 2.0 mm, and arteriography was performed during catheterization to diagnose AVF. Three years after the PCI, the distended cephalic vein was strongly distended, so vascular ligation was performed at another institution. Although a residual, unidentifiable arteriovenous shunt and a weak thrill persisted, the distended cephalic vein showed improvement, and the patient's condition remained favorable. Early detection of distal radial AVFs, potentially manageable by compression, underscores the importance of post-procedural vigilance in PCI patients.
- Open Access
- 18 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e79223
Pocket Perforation Using 3-0 Nylon Suture for Device Fixation
Device infection occurs at a rate of 1.5%, and age over 65 years is considered a risk factor. If a pacemaker infection occurs, it is recommended that both the generator and pacing lead be removed, which is a highly invasive complication that should be avoided. We report the case of an 83-year-old man whose 3-0 nylon suture used to fix the generator had perforated the body surface four years after pacemaker implantation. Fortunately, there was no evidence of infection, and thus we were able to repair the perforated portion of the nylon suture and replace the generator without removing the pacing lead. The patient had a body mass index (BMI) of 20.4 kg/m2 at the time of pacemaker implantation, but over the course of four years, the patient's BMI had progressively decreased to 18.4. The tip of the nylon suture was sharp, and the thinning of the subcutaneous tissue caused the tip of the nylon suture to perforate the skin. In this case, only the nylon suture protruded through the skin, reminding us of the strong penetrating power of the nylon tip. Preventive measures that are easy for physicians to implement include the use of thin nylon sutures with low penetration force for fixation. It is recommended to use silk sutures when fixing the generator, as the cut ends of the silk sutures are not sharp, and to fix the generator so that a knot is formed at the back. Also, implant a leadless pacemaker. We need to be careful because the number of pacemakers implanted in thin elderly patients is expected to increase in the future.
- 18 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e79223
Open AccessPocket Perforation Using 3-0 Nylon Suture for Device Fixation
Device infection occurs at a rate of 1.5%, and age over 65 years is considered a risk factor. If a pacemaker infection occurs, it is recommended that both the generator and pacing lead be removed, which is a highly invasive complication that should be avoided. We report the case of an 83-year-old man whose 3-0 nylon suture used to fix the generator had perforated the body surface four years after pacemaker implantation. Fortunately, there was no evidence of infection, and thus we were able to repair the perforated portion of the nylon suture and replace the generator without removing the pacing lead. The patient had a body mass index (BMI) of 20.4 kg/m2 at the time of pacemaker implantation, but over the course of four years, the patient's BMI had progressively decreased to 18.4. The tip of the nylon suture was sharp, and the thinning of the subcutaneous tissue caused the tip of the nylon suture to perforate the skin. In this case, only the nylon suture protruded through the skin, reminding us of the strong penetrating power of the nylon tip. Preventive measures that are easy for physicians to implement include the use of thin nylon sutures with low penetration force for fixation. It is recommended to use silk sutures when fixing the generator, as the cut ends of the silk sutures are not sharp, and to fix the generator so that a knot is formed at the back. Also, implant a leadless pacemaker. We need to be careful because the number of pacemakers implanted in thin elderly patients is expected to increase in the future.
- Open Access
- 9 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e78771
Transradial Lower Limb Arteriography of the Type Ⅲ Aortic Arch: A Reverse Technique
Percutaneous coronary intervention is generally performed using the radial artery approach, and in recent years, the radial artery approach has also been used more and more for endovascular treatment. Given this trend, the radial artery approach is also preferable for lower limb angiography when considering patient burden. However, in the case of type III aortic arch morphology, it can be difficult to advance the catheter into the descending aorta using the radial artery approach. In such cases, we have a method for guiding the catheter into the lower limb arteries using the radial artery approach. We were able to perform the procedure without complications in all three cases by reversing the Judkins right 4.0 catheter at the aortic valve, guiding the guidewire to the lower limb artery, and then advancing the catheter to perform lower limb angiography.
- 9 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e78771
Open AccessTransradial Lower Limb Arteriography of the Type Ⅲ Aortic Arch: A Reverse Technique
Percutaneous coronary intervention is generally performed using the radial artery approach, and in recent years, the radial artery approach has also been used more and more for endovascular treatment. Given this trend, the radial artery approach is also preferable for lower limb angiography when considering patient burden. However, in the case of type III aortic arch morphology, it can be difficult to advance the catheter into the descending aorta using the radial artery approach. In such cases, we have a method for guiding the catheter into the lower limb arteries using the radial artery approach. We were able to perform the procedure without complications in all three cases by reversing the Judkins right 4.0 catheter at the aortic valve, guiding the guidewire to the lower limb artery, and then advancing the catheter to perform lower limb angiography.
- Open Access
- 18 January 2025
- Published by Elsevier in Cardiovascular Revascularization Medicine: Interesting Cases
- Vol. 5
Bidirectional biopsy forceps approach for calcified common femoral artery lesion
- 18 January 2025
- Published by Elsevier in Cardiovascular Revascularization Medicine: Interesting Cases
- Vol. 5
Open AccessBidirectional biopsy forceps approach for calcified common femoral artery lesion