Bibin Prasad
Bibin Prasad has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Jung Kyung Kim
School of Mechanical Engineering, Kookmin University, Seoul, 02707, Republic of Korea
9 shared publications - Rajiv Chopra
Department of Radiology, UT Southwestern Medical Center
3 shared publications - Suzy Kim
Department of Radiation Oncology, Seoul National University Boramae Medical Center, Seoul, Korea
3 shared publications - Varun Sadaphal
Department of Radiology, UT Southwestern Medical Center
3 shared publications - David E. Greenberg
Department of Internal Medicine, Infectious Diseases and Geographic Medicine, University of Texas Southwestern Medical Center
2 shared publications Dustin Williams
Department of Orthopaedics, University of Utah, Salt Lake City, UT 84112, USA; Bone and Biofilm Research Lab, University of Utah, Salt Lake City, UT 84112, USA
2 shared publications
Latest Publications
- 21 October 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 102
Analysis of free liquid surface deformation and thermal destratification in liquid storage tanks using OpenFOAM
- 21 October 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 102
Analysis of free liquid surface deformation and thermal destratification in liquid storage tanks using OpenFOAM
- Open Access
- 13 September 2024
- Published by Elsevier in Journal of Infection
- Vol. 89 (5) , 106271
Alternating magnetic fields (AMF) and linezolid reduce Staphylococcus aureus biofilm in a large animal implant model
- 13 September 2024
- Published by Elsevier in Journal of Infection
- Vol. 89 (5) , 106271
Open AccessAlternating magnetic fields (AMF) and linezolid reduce Staphylococcus aureus biofilm in a large animal implant model
- Open Access
- 29 May 2022
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 713-724
Quantifying the relationship between biofilm reduction and thermal tissue damage on metal implants exposed to alternating magnetic fields
Metal implant infections are a devastating problem due to the formation of biofilm which impairs the effectiveness of antibiotics and leads to surgical replacement as definitive treatment. Biofilm ...
- 29 May 2022
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 713-724
Open AccessQuantifying the relationship between biofilm reduction and thermal tissue damage on metal implants exposed to alternating magnetic fields
Metal implant infections are a devastating problem due to the formation of biofilm which impairs the effectiveness of antibiotics and leads to surgical replacement as definitive treatment. Biofilm ...
- Open Access
- 23 December 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 81-96
Feasibility of heating metal implants with alternating magnetic fields (AMF) in scaled up models
Aim: Treatment of infected orthopedic implants remains a major medical challenge, involving prolonged antibiotic therapy and revision surgery, and adding a >$1 billion annual burden to the health care system in the US alone. Exposure of metallic implants to alternating magnetic fields (AMF) generates heat that can provide a noninvasive means to target biofilm adhered to the surface. In this study, an AMF system with a solenoid coil was constructed for targeting a metal plate surgically implanted in a sheep model. Methods: A tissue-mimicking phantom of the sheep leg was developed along with simulation model of phantom and the live sheep leg. This was used evaluate heating with the AMF system and to compare experimental results with numerical simulations. Comparative AMF exposures were performed/simulated in these model for feasibility of design, verification, and validation of simulations. Results: The system produced magnetic field strengths up to 12mT and achieved plate temperatures of 65–80 °C within 10–14 s. Single and intermittent AMF exposures of a tissue-mimicking phantom agreed with numerical simulations within 5 °C. Similar agreement between experimental measurements and simulations was also observed in the live sheep metal implant model. The simulations also predicted 2–3 mm of tissue damage using a CEM43 thermal dose model for 1-h AMF exposures targeting 65 °C for pulse delays of 2.5 and 5 mins. Conclusion: This study confirmed that AMF technology can be scaled up to treat implants in a large animal model with the same rates of heating and peak temperatures achieved in prior in vitro studies. Further, numerical simulations provided accurate predictions of the heating produced by AMF on metal implants and surrounding tissues, and can be used to design AMF coils for treating human prosthetic joint implants with more complex geometrical shapes.
- 23 December 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 81-96
Open AccessFeasibility of heating metal implants with alternating magnetic fields (AMF) in scaled up models
Aim: Treatment of infected orthopedic implants remains a major medical challenge, involving prolonged antibiotic therapy and revision surgery, and adding a >$1 billion annual burden to the health care system in the US alone. Exposure of metallic implants to alternating magnetic fields (AMF) generates heat that can provide a noninvasive means to target biofilm adhered to the surface. In this study, an AMF system with a solenoid coil was constructed for targeting a metal plate surgically implanted in a sheep model. Methods: A tissue-mimicking phantom of the sheep leg was developed along with simulation model of phantom and the live sheep leg. This was used evaluate heating with the AMF system and to compare experimental results with numerical simulations. Comparative AMF exposures were performed/simulated in these model for feasibility of design, verification, and validation of simulations. Results: The system produced magnetic field strengths up to 12mT and achieved plate temperatures of 65–80 °C within 10–14 s. Single and intermittent AMF exposures of a tissue-mimicking phantom agreed with numerical simulations within 5 °C. Similar agreement between experimental measurements and simulations was also observed in the live sheep metal implant model. The simulations also predicted 2–3 mm of tissue damage using a CEM43 thermal dose model for 1-h AMF exposures targeting 65 °C for pulse delays of 2.5 and 5 mins. Conclusion: This study confirmed that AMF technology can be scaled up to treat implants in a large animal model with the same rates of heating and peak temperatures achieved in prior in vitro studies. Further, numerical simulations provided accurate predictions of the heating produced by AMF on metal implants and surrounding tissues, and can be used to design AMF coils for treating human prosthetic joint implants with more complex geometrical shapes.
- Open Access
- 29 August 2019
- Published by Wiley in Journal of Oncology
- Vol. 2019, 1-12
Role of Simulations in the Treatment Planning of Radiofrequency Hyperthermia Therapy in Clinics
Hyperthermia therapy is a treatment modality in which tumor temperatures are elevated to higher temperatures to cause damage to cancerous tissues. Numerical simulations are integral in the development of hyperthermia treatment systems and in clinical treatment planning. In this study, simulations in radiofrequency hyperthermia therapy are reviewed in terms of their technical development and clinical aspects for effective clinical use. This review offers an overview of mathematical models and the importance of tissue properties; locoregional mild hyperthermia therapy, including phantom and realistic human anatomy models; phase array systems; tissue damage; thermal dose analysis; and thermoradiotherapy planning. This review details the improvements in numerical approaches in treatment planning and their application for effective clinical use. Furthermore, the modeling of thermoradiotherapy planning, which can be integrated with radiotherapy to provide combined hyperthermia and radiotherapy treatment planning strategies, are also discussed. This review may contribute to the effective development of thermoradiotherapy planning in clinics.
- 29 August 2019
- Published by Wiley in Journal of Oncology
- Vol. 2019, 1-12
Open AccessRole of Simulations in the Treatment Planning of Radiofrequency Hyperthermia Therapy in Clinics
Hyperthermia therapy is a treatment modality in which tumor temperatures are elevated to higher temperatures to cause damage to cancerous tissues. Numerical simulations are integral in the development of hyperthermia treatment systems and in clinical treatment planning. In this study, simulations in radiofrequency hyperthermia therapy are reviewed in terms of their technical development and clinical aspects for effective clinical use. This review offers an overview of mathematical models and the importance of tissue properties; locoregional mild hyperthermia therapy, including phantom and realistic human anatomy models; phase array systems; tissue damage; thermal dose analysis; and thermoradiotherapy planning. This review details the improvements in numerical approaches in treatment planning and their application for effective clinical use. Furthermore, the modeling of thermoradiotherapy planning, which can be integrated with radiotherapy to provide combined hyperthermia and radiotherapy treatment planning strategies, are also discussed. This review may contribute to the effective development of thermoradiotherapy planning in clinics.
- 2 July 2019
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 33 (7) , 3577-3584
Development of a thermal physiological model to analyze the effect of local radiant heaters in electric vehicles
- 2 July 2019
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 33 (7) , 3577-3584
Development of a thermal physiological model to analyze the effect of local radiant heaters in electric vehicles
- Open Access
- 8 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Quantitative Estimation of the Equivalent Radiation Dose Escalation using Radiofrequency Hyperthermia in Mouse Xenograft Models of Human Lung Cancer
Hyperthermia is a potent radiosensitizer, and its effect varies according to the different types of cancer cells. In the present study, the radiosensitizing effect of hyperthermia on lung cancer cell lines A549 and NCI-H1299 was determined based on the equivalent radiation dose escalation. In vitro cell experiments were conducted using lung cancer cell lines A549 and NCI-H1299 to determine thermal radiosensitivity. In vivo experiments were conducted using mouse heterotopic xenograft models to determine the treatment response and increase in the temperature of tumors using a 13.56 MHz radiofrequency (RF) hyperthermia device. Using the α and β values of the linear–quadratic equations of cell survival curves, numerical simulations were performed to calculate the equivalent radiation dose escalations. The dielectric properties of tumors were measured, and their effect on the calculated equivalent radiation dose was analyzed. Hyperthermia increased the equivalent radiation dose of lung cancer xenografts and a higher escalation was found in NCI-H1299 cells compared with that observed in A549 cells. An underestimation of the calculated equivalent radiation dose was observed when the dielectric property of the tumor was varied. This study may contribute to the effective planning of thermoradiotherapy in clinics.
- 8 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Open AccessQuantitative Estimation of the Equivalent Radiation Dose Escalation using Radiofrequency Hyperthermia in Mouse Xenograft Models of Human Lung Cancer
Hyperthermia is a potent radiosensitizer, and its effect varies according to the different types of cancer cells. In the present study, the radiosensitizing effect of hyperthermia on lung cancer cell lines A549 and NCI-H1299 was determined based on the equivalent radiation dose escalation. In vitro cell experiments were conducted using lung cancer cell lines A549 and NCI-H1299 to determine thermal radiosensitivity. In vivo experiments were conducted using mouse heterotopic xenograft models to determine the treatment response and increase in the temperature of tumors using a 13.56 MHz radiofrequency (RF) hyperthermia device. Using the α and β values of the linear–quadratic equations of cell survival curves, numerical simulations were performed to calculate the equivalent radiation dose escalations. The dielectric properties of tumors were measured, and their effect on the calculated equivalent radiation dose was analyzed. Hyperthermia increased the equivalent radiation dose of lung cancer xenografts and a higher escalation was found in NCI-H1299 cells compared with that observed in A549 cells. An underestimation of the calculated equivalent radiation dose was observed when the dielectric property of the tumor was varied. This study may contribute to the effective planning of thermoradiotherapy in clinics.
- Open Access
- 1 November 2018
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 11 (06)
Near-infrared laser irradiation of a multilayer agar-gel tissue phantom to induce thermal effect of traditional moxibustion
Traditional moxibustion therapy can stimulate heat and blood-vessel expansion and advance blood circulation. In the present study, a novel noncontact-type thermal therapeutic system was developed using a near-infrared laser diode. The device allows direct interaction of infrared laser light with the skin, thereby facilitating a controlled temperature distribution on the skin and the deep tissues below the skin. While using a tissue-mimicking phantom as a substitute for real skin, the most important optical and thermal parameters are the absorption/attenuation coefficient, thermal conductivity, and specific heat. We found that these parameters can be manipulated by varying the agar-gel concentration. Hence, a multilayer tissue-mimicking phantom was fabricated using different agar-gel concentrations. Thermal imaging and thermocouples were used to measure the temperature distribution inside the phantom during laser irradiation. The temperature increased with the increase in the agar-gel concentration and reached a maximum value under the tissue phantom surface. To induce a similar thermal effect of moxibustion therapy, controlled laser-irradiation parameters such as output power, wavelength and pulse width were obtained from further analysis of the temperature distribution. From the known optothermal properties of the patient’s skin, the temperature distribution inside the tissue was manipulated by optimizing the laser parameters. This study can contribute to patient-specific thermal therapy in clinics.
- 1 November 2018
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 11 (06)
Open AccessNear-infrared laser irradiation of a multilayer agar-gel tissue phantom to induce thermal effect of traditional moxibustion
Traditional moxibustion therapy can stimulate heat and blood-vessel expansion and advance blood circulation. In the present study, a novel noncontact-type thermal therapeutic system was developed using a near-infrared laser diode. The device allows direct interaction of infrared laser light with the skin, thereby facilitating a controlled temperature distribution on the skin and the deep tissues below the skin. While using a tissue-mimicking phantom as a substitute for real skin, the most important optical and thermal parameters are the absorption/attenuation coefficient, thermal conductivity, and specific heat. We found that these parameters can be manipulated by varying the agar-gel concentration. Hence, a multilayer tissue-mimicking phantom was fabricated using different agar-gel concentrations. Thermal imaging and thermocouples were used to measure the temperature distribution inside the phantom during laser irradiation. The temperature increased with the increase in the agar-gel concentration and reached a maximum value under the tissue phantom surface. To induce a similar thermal effect of moxibustion therapy, controlled laser-irradiation parameters such as output power, wavelength and pulse width were obtained from further analysis of the temperature distribution. From the known optothermal properties of the patient’s skin, the temperature distribution inside the tissue was manipulated by optimizing the laser parameters. This study can contribute to patient-specific thermal therapy in clinics.
- 1 May 2018
- Published by Elsevier in Journal of Thermal Biology
- Vol. 74, 281-289
Effect of tumor properties on energy absorption, temperature mapping, and thermal dose in 13.56-MHz radiofrequency hyperthermia
- 1 May 2018
- Published by Elsevier in Journal of Thermal Biology
- Vol. 74, 281-289
Effect of tumor properties on energy absorption, temperature mapping, and thermal dose in 13.56-MHz radiofrequency hyperthermia
- 24 September 2017
- Published by Springer Nature
- p. 705-709
Enhanced Particle Detection in a Spinning Helical Microchannel
- 24 September 2017
- Published by Springer Nature
- p. 705-709
Enhanced Particle Detection in a Spinning Helical Microchannel