GÖGökhan Ömeroğlu

Gökhan Ömeroğlu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gökhan Ömeroğlu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Investigation of Mixed Convection in CuZnFe2O4–Water Nanofluids Under Magnetic Fields Using Response Surface Methodology

    by Girayhan Arslan, Faraz Afshari, Hayrettin Eroğlu, Burak Muratçobanoğlu, Eyüphan Manay, Gökhan Ömeroğlu, Ahmet Dumlu

    This study experimentally investigates the mixed convection heat transfer performance of CuZnFe2O4–water-based magnetic nanofluids in a cylindrical minichannel under the influence of external magnetic fields. Nanofluids with three different volumetric concentrations (0.25%, 0.50%, and 0.75%) were synthesized and characterized in terms of thermophysical properties. The experiments were conducted within the Richardson number range of 0.1–10 to ensure mixed convection conditions, while magnetic field intensities of 220 G, 300 G, and 380 G were applied using custom-built electromagnets. Results show that suspending CuZnFe2O4 nanoparticles significantly enhances the heat transfer rate compared to pure water, mainly due to increased thermal conductivity and particle–fluid interactions. The application of a magnetic field further augments the Nusselt number by disturbing the thermal boundary layer and intensifying particle motion, leading to up to 64.4% improvement compared with pure water at similar Reynolds numbers. In addition, Analysis of Variance (ANOVA) and Response Surface Methodology (RSM) were employed to determine the most influential parameters on heat transfer performance and to develop a predictive correlation for the Nusselt number as a function of Reynolds number, nanoparticle concentration, and magnetic field intensity. The findings highlight the combined effects of nanoparticle suspension and magnetic field application as a promising approach for enhancing heat transfer in low-flow mixed convection regimes, offering valuable insights for thermal management in miniaturized cooling systems.

  • Open Access

    Experimental investigation of the effect of wave turbulators on heat transfer in pipes

    by Sendogan Karagoz, Semih Erzincanli, Orhan Yildirim, Ilker Firat, Mehmet Kaya, Omer Comakli, Gokhan Omeroglu

    This experimental study deals with the heat transfer and friction effects of sinusoidal part turbulators for single-phase flows occurring in a circular shaped pipe. Turbulators with three different radius values are placed in the pipe to make the flow turbulent. In this way, changes in Nusselt number and friction coefficient are examined. As a result of the experiments made with Reynolds numbers in the range of 6614-20710, the increase rates of the Nusselt numbers of turbulators with 20 mm, 110 mm, and 220 mm radius compared to the empty pipe were obtained as 153.49%, 85.36%, and 52.09%, respectively. As a result of the decrease in the radius, there was an increase in the Nusselt number and the friction factor. Parallel to the Nusselt number, the highest friction factor was obtained in the smallest radius turbulator. It was found that the thermal enhancement factors of 110 mm and 220 mm radius turbulators increased by 179.54% and 132.95%, respectively, compared to the 20 mm radius turbulator. Similarly, it was determined that the thermal enhancement factor of the 110 mm radius turbulator increased by 20% compared to the 220 mm radius turbulator.


  • Farklı Bağlantı Şekillerinin Panel Radyatörlerin Verimleri Üzerine Etkisinin İncelenmesi

    by Gökhan Ömeroğlu

    Bina ısıtma sistemlerinin, gerek konfor standartlarının oluşturulması gerekse insanoğlunun sağlıklı yaşam ortamlarında yaşayabilmeleri için uygulanması günümüzde kaçınılmazdır. Bir binanın ısıtma ihtiyacı yaygın olarak fosil yakıtlar kullanılarak ısıtılan suyun mahal içerisine yerleştirilen radyatörlerde dolaştırılması ile çözümlenmektedir. Mühendisler ısıtılacak mahaller için radyatör boyutlarını ve boru çaplarını projelendirirken radyatörlere yapılacak bağlantı şekilleri üzerine bir belirleme yapmamaktadırlar. Bu durumda sistemi oluşturan kişilerin tercihleri veya tecrübeleri ile rastgele bağlantılar uygulanmaktadır. Enerjinin etkin ve verimli kullanılması açısından doğru projelendirme ve verimin artırılması günümüz dünyasında oldukça önemlidir. Bu nedenle bir mahal içerisine yerleştirilen bir radyatörün doğru olarak boyutlandırılması veya radyatöre doğru boru çapı ile suyun taşınması kadar suyun giriş ve çıkış yönünün de etkisi önemlidir.  Bu çalışmada farklı boylarda modellenen panel radyatörler için 3 farklı bağlantı şeklinin etkisi hesaplamalı akışkanlar dinamiği (CFD) metodu kullanılarak incelenmiştir. Çalışmada radyatör boyunun artması ile panel veriminin bağlantı şekillerine göre azaldığı ve bağlantı şekillerinin verim üzerindeki etkisi gösterilmiştir.

  • Open Access

    CFD Analysis and Electrical Efficiency Improvement of a Hybrid PV/T Panel Cooled by Forced Air Circulation

    by Gökhan Ömeroğlu

    The thermal and electrical efficiency of a custom-designed PV/T panel cooled by forced air circulation was investigated by experimental and computational fluid dynamics (CFD) analysis. Experiments were carried out with four different array configurations, under constant irradiation of 1100 W/m2 and 3 different air velocities (3.3 m/s, 3.9 m/s, and 4.5 m/s). The heat transfer surface area and forced air circulation are known to positively affect the total heat transfer, and therefore, it is foreseeable that an increased number of fins and higher air velocities will help maintain the electrical efficiency of the panel at higher levels. The main objective of this study is to determine the critical threshold for the abovementioned parameters as well as to show how important parameters, such as fin arrangement and consequent turbulent air flows, are for satisfying the heat removal needs. Highest efficiency was achieved with a 108 pc type 1 arrangement at 12.02% as expected. Nevertheless, while the 108 pc type 2 arrangement could maintain the electrical efficiency at 11.81%, a close level of 11.55% could be obtained with a 54 pc type 2 arrangement. Experimental results are compared with ANSYS Fluent program, and the effect of the number and arrangement of the fins on the efficiency of the panel has been shown.


  • Open Access

    Investigation In Electrical And Thermal Efficiency Of An Active Cooling Photovoltaic Thermal (Pv/T) Solar System With Taguchi Method

    by Gökhan Ömeroğlu

    In this study, an attempt was made to optimize the default parameters in various experiments to improve the performance and heat transfer properties of the flat plate solar collector using the Taguchi method. An experimental investigation was carried out using air as working fluid at certain speeds (3.3, 3.9 & 4.5 m/s) on a PV/T collector. In this study, experiments were conducted to investigate the effects of heat transfer characteristics on performance, and the results are evaluated, since the above parameters have a great effect on the performance and heat transfer properties of the flat plate solar collector. Test Design for experiments were the Taguchi L36 Orthogonal Array Design. Experiments were carried out using the results of the outlet temperature of the air, the electrical and thermal efficiency of the collector, and the design of experiments by Taguchi method. The results showed that the selected parameters in this study had a significant effect on the selected responses and the verification results showed a significant improvement in the performance characteristics of the flat plate solar collector. The obtained results were analyzed in the ANSYS fluent program.


  • SU KAYNAMALI YATAY DÜZ BORUDA İKİ FAZLI AKIŞ BASINÇ DÜŞÜMÜ OSİLASYONLARININ ANALİZİ

    by Şendoğan Karagöz, Mehmet Yilmaz, Gökhan Ömeroğlu

    Two phase flows occur in many industrial applications such as refrigeration systems, turbo machinery, and power plant heat exchangers. Prediction of flow parameters is very crucial in design of two-phase flow equipment. Oscillations incurred by instabilities in two-phase flow systems cause mechanical vibrations, boiling crisis, high transient temperatures, control problems and even burnout at wall surface. This study is focused on determining steady state characteristic curves for certain inlet temperature and exit restriction conditions at different mass flow rates and compares variation of pressure drop type dynamic two phase flow instabilities in horizontal tube system. This work aims to predict low frequency pressure drop type oscillations in an in-tube boiling system. Results provide further understanding of mechanism of pressure-drop-type instabilities in a horizontal boiling tube system. They can also be utilized as guidance for design and control strategy of systems to avoid serious oscillation problems.

  • Open Access

    A scrutiny study on wave energy potential and policy in Turkey

    by Muhammet Kaan Yesilyurt, İlhan Volkan Öner, Gökhan Ömeroğlu, Efe Çetin Yilmaz

    A scrutiny study on wave energy potential and policy in TURKEY


  • Experimental and computational fluid dynamics analysis of a photovoltaic/thermal system with active cooling using aluminum fins

    by Gökhan Ömeroğlu

    Being the most widespread renewable energy generation system, photovoltaic (PV) systems face major problems, overheating and low overall conversion efficiency. The electrical efficiency of PV systems is adversely affected by significant increases in cell temperature upon exposure to solar irradiation. There have been several ways to remove excess heat and cool down the PV to maintain efficiency at fair levels. A hybrid photovoltaic/thermal system cooled by forced air circulation blown by a PV-powered fan was set up, and a rectangular control volume with cylindrical ends was built at the back of the PV panel where aluminum fins were placed in different arrangements and numbers. During the experiments, temperature and electrical output parameters were measured for three different air velocities (3.3, 3.9, and 4.5 m/s) and two different fin numbers and arrangements (54 pcs shifted and 108 pcs inline) under a constant radiation value of 1350 W/m2. While the electrical efficiency of the panel was reduced by almost 50% and decreased from 12% to 6.8% without active cooling, at 4.5-m/s air velocity and with 108 fins in inline arrangement, the electrical efficiency could be maintained at 11.5%. To compare and verify the experimental results, a heat transfer simulation model was developed with the ANSYS Fluent, and a good fit between the simulation and the test results was obtained.


  • Open Access

    Experimental Research of Dynamic Instabilities in the Presence of Coiled Wire Inserts on Two‐Phase Flow

    by Gokhan Omeroglu, Omer Comakli, Sendogan Karagoz, Bayram Sahin

    The aim of this study is to experimentally investigate the effect of the coiled wire insertions on dynamic instabilities and to compare the results with the smooth tube for forced convection boiling. The experiments were conducted in a circular tube, and water was used as the working fluid. Two different pitch ratios (H/D = 2.77 and 5.55) of coiled wire with circular cross‐sections were utilised. The constant heat flux boundary condition was applied to the outer side of the test tube, and the constant exit restriction was used at the tube outlet. The mass flow rate changed from 110 to 20 g/s in order to obtain a detailed idea about the density wave and pressure drop oscillations, and the range of the inlet temperature was 15–35°C. The changes in pressure drop, inlet temperature, amplitude, and the period with mass flow rate are presented. For each configuration, it is seen that density wave and pressure drop oscillations occur at all inlet temperatures. Analyses show that the decrease in the mass flow rate and inlet temperature causes the amplitude and the period of the density wave and the pressure drop oscillations to decrease separately.