HCHyang Hee Choi

Hyang Hee Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hyang Hee Choi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radio-Frequency/Microwave Gas Sensors Using Conducting Polymer

    by Chorom Jang, Jin-Kwan Park, Gi-Ho Yun, Hyang Hee Choi, Hee-Jo Lee, Jong-Gwan Yook

    In this review, the advances in radio-frequency (RF) /microwave chemical gas sensors using conducting polymers are discussed. First, the introduction of various conducting polymers is described. Only polyaniline (PANi), polypyrrole (PPy) and poly(3,4-ethylenedioxythiophene) (PEDOT), which are mainly used for gas sensors in RF/microwave region, are focused in this review. Sensing mechanism of the three conducting polymers are presented. And the RF/microwave characteristics and RF/microwave applications of the three conducting polymers are discussed. Moreover, the gas sensors using conducting polymers in RF/microwave frequencies are described. Finally, the the challenges and the prospects of the next generation of the RF/microwave based chemical sensors for wireless applications are proposed.


  • Open Access

    Microwave Properties of Coplanar Waveguide-Based PEDOT:PSS Conducting Polymer Line in Ethanol Gas Atmosphere

    by Hee-Jo Lee, Nathan Jeong, Hyang Hee Choi

    This study aims to investigate the microwave properties of coplanar waveguide (CPW)-based poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) conducting polymer line in an ethanol gas atmosphere, with the frequency range of 0.5–2 GHz. For an ethanol-exposed PEDOT:PSS line (test sample), the transmission coefficient (S21) decreased immediately; moreover, the microwave effective conductivity (σm/w) decreased simultaneously, compared with the ethanol-free PEDOT:PSS line (reference sample). The immediate variations in ΔS21 ( = S21,ethanol − S21,free) and Δσm/w ( = σm/w,ethanol − σm/w,free) were approximately 10.2 dB and 2.7 × 104 S/m, respectively. Furthermore, in the analysis of the circuit model of the PEDOT:PSS line, the characteristic impedance and distributed elements, i.e., resistance (R) and inductance (L) per length, of the test sample increased, compared with the reference sample. However, upon stopping the exposure to ethanol gas, the microwave properties of the test sample instantaneously recovered to those of the reference sample. According to these critical observations, we could confirm that the coplanar waveguide with a PEDOT:PSS line shows a significant difference in the diverse microwave properties, through rapid response to the ethanol gas at room temperature.


  • Flexible polymer thermoelectric device based on PEDOT:PSS and surface treated pyromellitic dianhydride‐oxydianiline polyimide substrate

    by Juheon Lee, Seohyun Kim, Moonhyun Chung, Hakgeun Jeong, Hyanghee Choi, Haksoo Han

    Flexible polymer thermoelectric devices based on poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) and pyromellitic dianhydride‐oxydianiline polyimide polyimide (PI) were fabricated and investigated in this work. PI was selected as a substrate for PEDOT:PSS to secure from repeated bending cycles of flexible device. To enhance the interfacial adhesion between PEDOT:PSS and PI, oxygen plasma treatment was used on the surface of PI substrate. The effect of the surface treatment with oxygen plasma on the synthesized PI substrate was significant. The polar component of surface free energy of PI was increased from 2.8 to 31.8 mJ/m2. The power factor of PEDOT:PSS on the PI substrate was increased from 25.86 to 43.78 μW m−1 K−2. Also, as a result of 10 k times of bending test, the electrical performance consistency and the mechanical stability of the fabricated devices were confirmed. This verified fabricated flexible polymer thermoelectric devices based on PEDOT:PSS and PI are suitable for the various applications.


  • N-type organic thermoelectric materials based on polyaniline doped with the aprotic ionic liquid 1-ethyl-3-methylimidazolium ethyl sulfate

    by Dohyuk Yoo, Jung Joon Lee, Chanil Park, Hyang Hee Choi, Jung-Hyun Kim

    The thermopower performance of polyaniline doped with the considerably reliable ionic liquid 1-ethyl-3-methylimidazolium ethyl sulfate was investigated to determine its potential as an alternative to fossil fuels. The ionic liquid, a stable ion complex, was used as the chemical dopant to confer n-type electrical properties to the polyaniline conducting polymer. The ionic liquid-doped polyaniline had an electrical conductivity, n-type Seebeck coefficient, and thermopower execution of 0.23 S m−1, −138.8 μV K−1, and 4.43 × 10−3 μW m−1 K−2, respectively as a result of the chemical doping method and thermal treatment. In addition, the ionic liquid-doped polyaniline realized a stable n-type thermoelectric performance under ambient conditions for 15 days.


  • Thermoelectric Behavior of Conducting Polymers Hybridized with Inorganic Nanoparticles

    by Woohyun Son, Seung Hwan Lee, Hongkwan Park, Hyang Hee Choi, Jung Hyun Kim


  • Behavior of Toxic Gas Sensor Based on Conducting Polypyrrole

    by Jung Joon Lee, Dohyuk Yoo, Chanil Park, Jung Hyun Kim, Hyang Hee Choi


  • Gradual thickness-dependent enhancement of the thermoelectric properties of PEDOT:PSS nanofilms

    by Dohyuk Yoo, Woohyun Son, Seyul Kim, Jung Joon Lee, Seung Hwan Lee, Hyang Hee Choi, Jung Hyun Kim

    We investigated the spinning speed dependent surface composition for TE performance with PEDOT:PSS films. The Seebeck coefficient and electrical conductivity of PEDOT:PSS film decrease as the spinning speed elevates. The thicker nanofilm exhibited the best properties in terms of the electrical conductivity and Seebeck coefficient.


  • Novel solution-processable, dedoped semiconductors for application in thermoelectric devices

    by Seung Hwan Lee, Hongkwan Park, Woohyun Son, Hyang Hee Choi, Jung Hyun Kim

    The thermoelectric performance of poly(3,4-ethylenedioxythiophene) complexed with a poly(4-styrenesulfonic acid) (PEDOT:PSS) film was enhanced by a three-step process. First, ultrafiltration was applied to remove non-complexed PSS from PEDOT:PSS grains. The ultrafiltration treatment leads to an improvement in the power factor (S2σ) from 54.9 to 83.2 μW m−1 K−2 and a decrease in the thermal conductivity (κ) from 0.330 to 0.170 W m−1 K−1. Second, the fully de-doped PEDOT:PSS solution was prepared by addition of hydrazine, which acted as a reducing agent. Third, the two PEDOT:PSS solutions (ultrafiltered and hydrazine-treated) were mixed in different ratios by simple ultrasonication blending without any post-treatment. The optimal S2σ value of 115.5 μW m−1 K−2 (∼10 times higher than that of the pristine PEDOT:PSS film) and ZT value of 0.2 were recorded at 33 wt% of the hydrazine-treated, ultrafiltered PEDOT:PSS in the blend.


  • Open Access

    Detection of a CO and NH3 gas mixture using carboxylic acid-functionalized single-walled carbon nanotubes

    by Ki-Young Dong, Jinnil Choi, Yang Doo Lee, Byung Hyun Kang, Youn-Yeol Yu, Hyang Hee Choi, Byeong-Kwon Ju

    Carbon nanotubes (CNT) are extremely sensitive to environmental gases. However, detection of mixture gas is still a challenge. Here, we report that 10 ppm of carbon monoxide (CO) and ammonia (NH3) can be electrically detected using a carboxylic acid-functionalized single-walled carbon nanotubes (C-SWCNT). CO and NH3 gases were mixed carefully with the same concentrations of 10 ppm. Our sensor showed faster response to the CO gas than the NH3 gas. The sensing properties and effect of carboxylic acid group were demonstrated, and C-SWCNT sensors with good repeatability and fast responses over a range of concentrations may be used as a simple and effective detection method of CO and NH3 mixture gas.


  • Open Access

    Noxious gas detection using carbon nanotubes with Pd nanoparticles

    by Hyang Hee Choi, Junmin Lee, Ki-Young Dong, Byeong-Kwon Ju, Wooyoung Lee

    Noxious gas sensors were fabricated using carbon nanotubes [CNTs] with palladium nanoparticles [Pd NPs]. An increase in the resistance was observed under ammonia for both CNTs and CNT-Pd sensors. Under carbon monoxide [CO], the two sensors exhibited different behaviors: for CNT sensors, their resistance decreased slightly with CO exposure, whereas CNT-Pd sensors showed an increase in resistance. The sensing properties and effect of Pd NPs were demonstrated, and CNT-Pd sensors with good repeatability and fast responses over a range of concentrations may be used as a simple and effective noxious gas sensor at room temperature.