Nobuhisa Matsumura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nobuhisa Matsumura has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Takashi Shibata
Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
5 shared publicationsYukio Horie
Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
5 shared publicationsMichiya Kubo
Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
3 shared publicationsHironaga Kamiyama
Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
2 shared publicationsNakamasa Hayashi
2 shared publicationsShunro Endo
Department of Neurosurgery, Faculty of Medicine, University of Toyama
2 shared publications
Latest Publications
- Open Access
- 1 January 2014
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 54 (6) , 497-501
An Operating Microscope with Higher Magnification and Higher Resolution for Cerebral Aneurysm Surgery: Preliminary Experience—Technical Note
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2014
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 54 (6) , 497-501
Open AccessAn Operating Microscope with Higher Magnification and Higher Resolution for Cerebral Aneurysm Surgery: Preliminary Experience—Technical Note
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- Open Access
- 1 January 2012
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 3 (1) , 152
A new bayonet spring microsurgical instrument handle with a bar for microneurosurgery
The bayonet-shaped spring surgical instrument is essential and perhaps the most important tool in microneurosurgery. It is needed to be handled gently, and so stable handling to the spring tension of the long instrument handle is necessary for fine action in narrow and deep operative fields under an operating microscope. A bayonet spring microsurgical instrument handle with a bar as a stabilizer is presented for facilitating delicate microsurgical manipulations stably in microneurosurgery. The bar with the handle is a metric projection. The grip of this instrument is a modified writing grasp, which is composed of writing grasp and sandwiching a lateral-projected bar with handle between the medial side of the index finger and the lateral side of the middle finger. Then, this bar as a stabilizer of the instrument is suitable to fix it. Microneurosurgical operations using this instrument system were performed. This was advantageous to stabilize the instrument in deep and narrow operative fields, to be sensitive to move its functional tips by fingertips, and to reduce unwanted movements under an operating microscope. This was disadvantageous to limit the rotational movement within fingers. There were no complications. This handle would provide a steady and balanced grip to ensure precise manipulation of the functional tips of the bayonet instrument for microneurosurgery. It may be useful particularly for the beginners or for the non-dominant hand of microsurgeons.
- 1 January 2012
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 3 (1) , 152
Open AccessA new bayonet spring microsurgical instrument handle with a bar for microneurosurgery
The bayonet-shaped spring surgical instrument is essential and perhaps the most important tool in microneurosurgery. It is needed to be handled gently, and so stable handling to the spring tension of the long instrument handle is necessary for fine action in narrow and deep operative fields under an operating microscope. A bayonet spring microsurgical instrument handle with a bar as a stabilizer is presented for facilitating delicate microsurgical manipulations stably in microneurosurgery. The bar with the handle is a metric projection. The grip of this instrument is a modified writing grasp, which is composed of writing grasp and sandwiching a lateral-projected bar with handle between the medial side of the index finger and the lateral side of the middle finger. Then, this bar as a stabilizer of the instrument is suitable to fix it. Microneurosurgical operations using this instrument system were performed. This was advantageous to stabilize the instrument in deep and narrow operative fields, to be sensitive to move its functional tips by fingertips, and to reduce unwanted movements under an operating microscope. This was disadvantageous to limit the rotational movement within fingers. There were no complications. This handle would provide a steady and balanced grip to ensure precise manipulation of the functional tips of the bayonet instrument for microneurosurgery. It may be useful particularly for the beginners or for the non-dominant hand of microsurgeons.
- 25 October 2011
- Published by Wiley in Microsurgery
- Vol. 31 (8) , 671-672
A newly designed ruler of a 0.1-mm scale on the tip of microsurgical instrument in supermicrosurgery
- 25 October 2011
- Published by Wiley in Microsurgery
- Vol. 31 (8) , 671-672
A newly designed ruler of a 0.1-mm scale on the tip of microsurgical instrument in supermicrosurgery
- 24 August 2011
- Published by Wiley in Microsurgery
- Vol. 31 (7) , 586-588
Novel microsurgical precision grip and spring-handled instrument with a variable stabilizer
- 24 August 2011
- Published by Wiley in Microsurgery
- Vol. 31 (7) , 586-588
Novel microsurgical precision grip and spring-handled instrument with a variable stabilizer
- 29 June 2011
- Published by Georg Thieme Verlag KG in Journal of Reconstructive Microsurgery
- Vol. 27 (06) , 377-382
Basic Training Model for Supermicrosurgery: A Novel Practice Card Model
Supermicrosurgery has been developed and reported the anastomosis of vessels with diameters of about 0.5 mm or less. The anastomosis of vessels of about 0.5 mm or less in diameter is technically more difficult than 1.0 mm or larger. This article describes a novel practice card model for acquiring basic supermicrosurgical techniques. A practice card is composed of very small-caliber silicone tubes simulating very small-caliber vessels and a thick paper. The silicone tube external diameters are 0.3, 0.5, or 0.7 mm. The thickness of the tube wall is 0.05 mm. Microsurgeons can easily begin to practice and warm up the supermicrosurgical suturing and anastomosing techniques using this nonvital practice card under a personal desk stereomicroscope in the office and an operating microscope in the operating room. This training model is a simple system for practicing basic supermicrosurgical techniques repeatedly and for warming up before a supermicrosurgical operation. This article also describes basic training regarding its use at high magnifications. This training-based supermicrosurgical skill may become a valuable technique for microsurgeons in many specialties.
- 29 June 2011
- Published by Georg Thieme Verlag KG in Journal of Reconstructive Microsurgery
- Vol. 27 (06) , 377-382
Basic Training Model for Supermicrosurgery: A Novel Practice Card Model
Supermicrosurgery has been developed and reported the anastomosis of vessels with diameters of about 0.5 mm or less. The anastomosis of vessels of about 0.5 mm or less in diameter is technically more difficult than 1.0 mm or larger. This article describes a novel practice card model for acquiring basic supermicrosurgical techniques. A practice card is composed of very small-caliber silicone tubes simulating very small-caliber vessels and a thick paper. The silicone tube external diameters are 0.3, 0.5, or 0.7 mm. The thickness of the tube wall is 0.05 mm. Microsurgeons can easily begin to practice and warm up the supermicrosurgical suturing and anastomosing techniques using this nonvital practice card under a personal desk stereomicroscope in the office and an operating microscope in the operating room. This training model is a simple system for practicing basic supermicrosurgical techniques repeatedly and for warming up before a supermicrosurgical operation. This article also describes basic training regarding its use at high magnifications. This training-based supermicrosurgical skill may become a valuable technique for microsurgeons in many specialties.
- 1 January 2011
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 51 (12) , 872-874
Higher Magnification Microsurgical Repair of Donor Artery Dissection in Superficial Temporal Artery to Middle Cerebral Artery Anastomosis -Technical Note-
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2011
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 51 (12) , 872-874
Higher Magnification Microsurgical Repair of Donor Artery Dissection in Superficial Temporal Artery to Middle Cerebral Artery Anastomosis -Technical Note-
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- Open Access
- 1 January 2011
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 2 (1) , 6
Microvascular anastomosis at 30-50× magnifications (super-microvascular anastomosis) in neurosurgery
We report a safe and precise technique of microvascular anastomosis at higher magnifications (30 - 50 ×) in neurosurgery and evaluate our experiences to examine the utility of this method for cerebral revascularization in various situations. A retrospective review was carried out of patients who underwent microvascular anastomosis using a high-magnified operating microscope. This method was performed in 30 patients with 35 microvascular anastomoses in various situations. This microscope has two optical systems, a standard zooming system and a newly developed high magnification system. High resolution and good depth of focus are achieved by a new lens design in the optical system, which makes the image of the object very clear at higher magnifications. In this operating microscope, the combination of a 10 × eyepiece and the 200, 250, and 300-mm objective lens enables a range of final magnifications from 2.9 × to 50.4 ×. This method enabled one to pay attention to performing atraumatic manipulations of small vessels and correct suturing, intima-to-intima, of vessel walls. Microvascular anastomoses were performed safely and precisely at higher magnifications. All anastomoses were patent. It is obvious that practical final magnifications of more than 30 × in neurosurgery would be super-magnified operative views. Microvascular anastomosis at 30 - 50 × magnifications (super-microvascular anastomosis) can help neurosurgeons to improve their skills, with good visualization, and to be safe and accurate when conducting cerebral revascularization in various situations.
- 1 January 2011
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 2 (1) , 6
Open AccessMicrovascular anastomosis at 30-50× magnifications (super-microvascular anastomosis) in neurosurgery
We report a safe and precise technique of microvascular anastomosis at higher magnifications (30 - 50 ×) in neurosurgery and evaluate our experiences to examine the utility of this method for cerebral revascularization in various situations. A retrospective review was carried out of patients who underwent microvascular anastomosis using a high-magnified operating microscope. This method was performed in 30 patients with 35 microvascular anastomoses in various situations. This microscope has two optical systems, a standard zooming system and a newly developed high magnification system. High resolution and good depth of focus are achieved by a new lens design in the optical system, which makes the image of the object very clear at higher magnifications. In this operating microscope, the combination of a 10 × eyepiece and the 200, 250, and 300-mm objective lens enables a range of final magnifications from 2.9 × to 50.4 ×. This method enabled one to pay attention to performing atraumatic manipulations of small vessels and correct suturing, intima-to-intima, of vessel walls. Microvascular anastomoses were performed safely and precisely at higher magnifications. All anastomoses were patent. It is obvious that practical final magnifications of more than 30 × in neurosurgery would be super-magnified operative views. Microvascular anastomosis at 30 - 50 × magnifications (super-microvascular anastomosis) can help neurosurgeons to improve their skills, with good visualization, and to be safe and accurate when conducting cerebral revascularization in various situations.
- 1 December 2009
- Published by Elsevier in Surgical Neurology
- Vol. 72 (6) , 690-694
Extracranial-intracranial bypass surgery at high magnification using a new high-resolution operating microscope: technical note
- 1 December 2009
- Published by Elsevier in Surgical Neurology
- Vol. 72 (6) , 690-694
Extracranial-intracranial bypass surgery at high magnification using a new high-resolution operating microscope: technical note
- 1 May 2009
- Published by Elsevier in Surgical Neurology
- Vol. 71 (5) , 616-620
A newly designed training tool for microvascular anastomosis techniques: Microvascular Practice Card
- 1 May 2009
- Published by Elsevier in Surgical Neurology
- Vol. 71 (5) , 616-620
A newly designed training tool for microvascular anastomosis techniques: Microvascular Practice Card