    The development of biomedical engineering as experienced by one biomedical engineer

    by Jonathan C Newell

    This personal essay described the development of the field of Biomedical Engineering from its early days, from the perspective of one who lived through that development. It describes the making of a major invention using data that had been rejected by other scientists, the re-discovery of an obscure fact of physiology and its use in developing a major medical instrument, the development of a new medical imaging modality, and the near-death rescue of a research project. The essay concludes with comments about the development and present status of impedance imaging, and recent changes in the evolution of biomedical engineering as a field.


  • Robust Linearized Image Reconstruction for Multifrequency EIT of the Breast

    by Gregory Boverman, Tzu-Jen Kao, Rujuta Kulkarni, Bong Seok Kim, David Isaacson, Gary J. Saulnier, Jonathan C. Newell

    Electrical impedance tomography (EIT) is a developing imaging modality that is beginning to show promise for detecting and characterizing tumors in the breast. At Rensselaer Polytechnic Institute, we have developed a combined EIT-tomosynthesis system that allows for the coregistered and simultaneous analysis of the breast using EIT and X-ray imaging. A significant challenge in EIT is the design of computationally efficient image reconstruction algorithms which are robust to various forms of model mismatch. Specifically, we have implemented a scaling procedure that is robust to the presence of a thin highly-resistive layer of skin at the boundary of the breast and we have developed an algorithm to detect and exclude from the image reconstruction electrodes that are in poor contact with the breast. In our initial clinical studies, it has been difficult to ensure that all electrodes make adequate contact with the breast, and thus procedures for the use of data sets containing poorly contacting electrodes are particularly important. We also present a novel, efficient method to compute the Jacobian matrix for our linearized image reconstruction algorithm by reducing the computation of the sensitivity for each voxel to a quadratic form. Initial clinical results are presented, showing the potential of our algorithms to detect and localize breast tumors.


  • A Versatile High-Permittivity Phantom for EIT

    by Tzu-Jen Kao, Gary J. Saulnier, David Isaacson, Tomas L. Szabo, Jonathan C. Newell

    Phantoms are frequently used in medical imaging systems to test hardware, reconstruction algorithms, and the interpretation of data. This report describes and characterizes the use of powdered graphite as a means of adding a significant reactive component or permittivity to useful phantom media for electrical impedance imaging. The phantom materials produced have usable complex admittivity at the electrical impedance tomography (EIT) frequencies from a few kilohertz to 1 MHz, as measured by our EIT system (ACT4) and by a commercial bioimpedance analyzer (BIS 4000, Xitron). We have also studied a commercial ultrasound coupling gel, which is highly electrically conductive and semisolid but that permits objects to move within it. The mixture of agar-graphite and gel-graphite, increases in permittivity and conductivity are proportional to the graphite concentration. We also report the use of a porous polymer membrane to simulate skin. A thin layer of this membrane increased resistance and the characteristic frequency of the phantoms, providing a promising candidate to simulate the effect of skin and the layered structure of a breast or other anatomical structure. The graphite also provides a realistic level of ldquospecklerdquo in ultrasound images of the phantom, which may be useful in developing dual-mode imaging systems with ultrasound and the EIT.


  • Regional Admittivity Spectra With Tomosynthesis Images for Breast Cancer Detection: Preliminary Patient Study

    by Tzu-Jen Kao, Gregory Boverman, Bong Seok Kim, David Isaacson, Gary J. Saulnier, Jonathan C. Newell, Myoung H. Choi, Richard H. Moore, Daniel B. Kopans

    It has been known for some time that many tumors have a significantly different conductivity and permittivity from surrounding normal tissue. This high ldquocontrastrdquo in tissue electrical properties, occurring between a few kilohertz and several megahertz, may permit differentiating malignant from benign tissues. Here we show the ability of electrical impedance spectroscopy (EIS) to roughly localize and clearly distinguish cancers from normal tissues and benign lesions. Localization of these lesions is confirmed by simultaneous, in register digital breast tomosynthesis (DBT) mammography or 3-D mammograms.


  • The Complete Electrode Model For Imaging and Electrode Contact Compensation in Electrical Impedance Tomography

    by Gregory Boverman, Bong Seok Kim, David Isaacson, Jonathan C. Newell

    Electrical impedance tomography (EIT) is an imaging modality which currently shows promise for the detection and characterization of breast cancer. A very significant problem in EIT imaging is the proper modeling of the interface between the body and the electrodes. We have found empirically that it is very difficult, in a clinical setting, to assure that all electrodes make satisfactory contact with the body. In addition, we have observed a capacitive effect at skin/electrode boundary that is spatially heterogeneous. To compensate for these problems, we have developed a hybrid nonlinear-linear reconstruction algorithm in which we first estimate electrode surface impedances, using a Newton-type iterative optimization procedure with an analytically computed Jacobian matrix. We subsequently make use of a linearized algorithm to perform a three-dimensional reconstruction of perturbations in both contact impedances and in the spatial distributions of conductivity and permittivity. Results show that, using this procedure, artifacts due to electrodes making poor contact can be greatly reduced.


  • An Electrical Impedance Spectroscopy System for Breast Cancer Detection

    by Gary J. Saulnier, Ning Liu, Chandana Tamma, Hongjun Xia, Tzu-Jen Kao, J. C. Newell, David Isaacson

    This paper describes Rensselaer's ACT 4 electrical impedance tomography system which has been developed for breast cancer detection. ACT 4 acquires electrical impedance data at a set of discrete frequencies in the range from 3.33 kHz to 1 MHz and can support up to 72 electrodes. The instrument applies either voltages or currents to all the electrodes simultaneously and measures the resulting currents and/or voltages. Radiolucent electrode arrays are applied to the compression plates of an x-ray mammography system for collecting impedance data in register with x-ray images. The analog front-end electronics are supported with a distributed digital system, including a computer, Digital Signal Processors (DSPs) and Field-Programmable Gate Arrays (FPGAs). A Microsoft Visual C/C++ -based user interface controls the system operation. The overall system architecture is presented as well as performance results.


  • Layered Model for Breasts in Electrical Impedance Tomography

    by Rujuta Kulkarni, Gregory Boverman, David Isaacson, Gary Saulnier, Jonathan C. Newell

    We are presently using Electrical Impedance Tomography as a technique for breast cancer imaging, determining the admittivity distribution inside the breast. The admittivities we observed in compressed breasts in EIT were lower than those seen in earlier studies involving whole chest imaging. We attribute this to a thin low admittance skin layer which dominates in compressed breasts. To more accurately model breasts, we have developed a layered analytical forward model. Our layered model has three layers, thin low admittivity top and bottom layers representing skin and a thicker high admittivity middle layer representing breast tissue. In this paper we derive the forward solution for this layered geometry and compare it to the forward solution for the homogeneous case. We also demonstrate the improvement in reconstruction of a target embedded in a layered body when the homogeneous forward solution is replaced by the layered forward solution.


  • Regional Admittivity Spectra with Tomosynthesis Images for Breast Cancer Detection

    by Tzu-Jen Kao, Gregory Boverman, David Isaacson, Gary J. Saulnier, Jonathan C. Newell, Richard H. Moore, Daniel B. Kopans

    Because the electrical properties of many breast tumors are different from those of surrounding, normal tissue, imaging these properties may provide useful diagnostic information. At the present time, X-ray mammography is the standard imaging modality used for breast cancer screening. The interpretation of EIT imaging is thus enhanced by its use together with X-ray mammography in the same geometry. This paper reports the ability of electrical impedance spectroscopy (EIS) to localize and distinguish cancers from normal tissues. These findings are confirmed by simultaneous, co-registered 3-D mammograms or tomosynthesis images and are verified with biopsy reports.


  • Regional Admittivity Spectra with Mammograms in Breast Biopsy Patients

    by J. C. Newell, G. J. Saulnier, D. Isaacson, T-J. Kao, H. Xia, A. S. Ross, B. S. Kim, R. H. Moore, D. B. Kopans

  • A method for analyzing electrical impedance spectroscopy data from breast cancer patients

    by Bong Seok Kim, David Isaacson, Hongjun Xia, Tzu-Jen Kao, Jonathan C Newell, Gary J Saulnier

    Research on freshly-excised malignant breast tissues and surrounding normal tissues in an in vitro impedance cell has shown that breast tumors have different conductivity and permittivity from normal or non-malignant tissues. This contrast may provide a basis for breast cancer detection using electrical impedance imaging. This paper describes a procedure for collecting electrical impedance spectroscopy data simultaneously and in register with tomosynthesis data from patients. We describe the methods used to analyze the data in order to determine if the electrodes are making contact with the breast of the patient. Canonical voltage patterns are applied and used to synthesize the data that would have resulted from constant voltage patterns applied to each of two parallel mammography plates. A type of Cole-Cole plot is generated and displayed from each of the currents measured on each of the electrodes for each of the frequencies (5, 10, 30, 100 and 300 kHz) of applied voltages. We illustrate the potential usefulness of these displays in distinguishing breast cancer from benign lesions with the Cole-Cole plots for two patients--one having cancer and one having a benign lesion--by comparing these graphs with electrical impedance spectra previously found by Jossinet and Schmitt in tissue samples taken from a variety of patients.