Sergei F. Boulyga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sergei F. Boulyga has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Zsuzsanna Macsik
Department of Safeguards, International Atomic Energy Agency, 1400 Vienna, Austria
2 shared publications- Alexander Venzin
Department of Safeguards, Office of Safeguards Analytical Services, International Atomic Energy Agency, Seibersdorf, Austria
1 shared publication Andreas Koepf
Office of Safeguards Analytical Services, Department of Safeguards, International Atomic Energy Agency, 1400 Vienna, Austria
1 shared publication- Andreas Koepf
Department of Safeguards, Office of Safeguards Analytical Services, International Atomic Energy Agency, Seibersdorf, Austria
1 shared publication Guillaume Stadelmann
Office of Safeguards Analytical Services, Department of Safeguards, International Atomic Energy Agency, 1400 Vienna, Austria
1 shared publicationJ. Alan Cunningham
Department of Safeguards, International Atomic Energy Agency, 1400 Vienna, Austria
1 shared publication
Latest Publications
- Open Access
- 17 January 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (7) , 2807
In memory of Maxim Penkin
- 17 January 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (7) , 2807
Open AccessIn memory of Maxim Penkin
- 10 January 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (7) , 2851-2861
Estimating the capabilities of the TIMS TE analytical technique using random effects models applied to quality control measurements
- 10 January 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (7) , 2851-2861
Estimating the capabilities of the TIMS TE analytical technique using random effects models applied to quality control measurements
- 19 September 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (11) , 2226-2237
Development, validation and verification of an ICP-MS procedure for a multi-element analysis of uranium ore concentrates
A validated procedure for SF-ICP-MS determination of 67 minor and trace elements in uranium ore concentrates applied to nuclear safeguards.
- 19 September 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (11) , 2226-2237
Development, validation and verification of an ICP-MS procedure for a multi-element analysis of uranium ore concentrates
A validated procedure for SF-ICP-MS determination of 67 minor and trace elements in uranium ore concentrates applied to nuclear safeguards.
- 5 October 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (11) , 2272-2284
Uranium isotope analysis by MC-ICP-MS in sub-ng sized samples
This study describes the multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) method for the determination of n ( 233 U)/ n ( 238 U), n ( 234 U)/ n ( 238 U), n ( 235 U)/ n ( 238 U), and n ( 236 U)/ n ( 238 U) isotope ratios in purified uranium solutions.
- 5 October 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (11) , 2272-2284
Uranium isotope analysis by MC-ICP-MS in sub-ng sized samples
This study describes the multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) method for the determination of n ( 233 U)/ n ( 238 U), n ( 234 U)/ n ( 238 U), n ( 235 U)/ n ( 238 U), and n ( 236 U)/ n ( 238 U) isotope ratios in purified uranium solutions.
- Open Access
- 1 November 2012
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 113 (8) , 8-15
Direct uranium isotope ratio analysis of single micrometer-sized glass particles
- 1 November 2012
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 113 (8) , 8-15
Open AccessDirect uranium isotope ratio analysis of single micrometer-sized glass particles
- 23 June 2009
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 29 (5) , 685-716
Calcium isotope analysis by mass spectrometry
The variations in the isotopic composition of calcium caused by fractionation in heterogeneous systems and by nuclear reactions can provide insight into numerous biological, geological, and cosmic processes, and therefore isotopic analysis finds a wide spectrum of applications in cosmo‐ and geochemistry, paleoclimatic, nutritional, and biomedical studies. The measurement of calcium isotopic abundances in natural samples has challenged the analysts for more than three decades. Practically all Ca isotopes suffer from significant isobaric interferences, whereas low‐abundant isotopes can be particularly affected by neighboring major isotopes. The extent of natural variations of stable isotopes appears to be relatively limited, and highly precise techniques are required to resolve isotopic effects. Isotope fractionation during sample preparation and measurements and instrumental mass bias can significantly exceed small isotope abundance variations in samples, which have to be investigated. Not surprisingly, a TIMS procedure developed by Russell et al. (Russell et al., . Geochim Cosmochim Acta 42: 1075–1090) for Ca isotope measurements was considered as revolutionary for isotopic measurements in general, and that approach is used nowadays (with small modifications) for practically all isotopic systems and with different mass spectrometric techniques. Nevertheless, despite several decades of calcium research and corresponding development of mass spectrometers, the available precision and accuracy is still not always sufficient to achieve the challenging goals. The present article discusses figures of merits of presently used analytical methods and instrumentation, and attempts to critically assess their limitations. In Sections 2 and 3, mass spectrometric methods applied to precise stable isotope analysis and to the determination of 41Ca are described. Section 4 contains a short summary of selected applications, and includes tracer experiments and the potential use of biological isotope fractionation in medical studies, paleoclimatic and paleoceanographic, and other terrestrial as well as extraterrestrial investigations. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:685–716, 2010
- 23 June 2009
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 29 (5) , 685-716
Calcium isotope analysis by mass spectrometry
The variations in the isotopic composition of calcium caused by fractionation in heterogeneous systems and by nuclear reactions can provide insight into numerous biological, geological, and cosmic processes, and therefore isotopic analysis finds a wide spectrum of applications in cosmo‐ and geochemistry, paleoclimatic, nutritional, and biomedical studies. The measurement of calcium isotopic abundances in natural samples has challenged the analysts for more than three decades. Practically all Ca isotopes suffer from significant isobaric interferences, whereas low‐abundant isotopes can be particularly affected by neighboring major isotopes. The extent of natural variations of stable isotopes appears to be relatively limited, and highly precise techniques are required to resolve isotopic effects. Isotope fractionation during sample preparation and measurements and instrumental mass bias can significantly exceed small isotope abundance variations in samples, which have to be investigated. Not surprisingly, a TIMS procedure developed by Russell et al. (Russell et al., . Geochim Cosmochim Acta 42: 1075–1090) for Ca isotope measurements was considered as revolutionary for isotopic measurements in general, and that approach is used nowadays (with small modifications) for practically all isotopic systems and with different mass spectrometric techniques. Nevertheless, despite several decades of calcium research and corresponding development of mass spectrometers, the available precision and accuracy is still not always sufficient to achieve the challenging goals. The present article discusses figures of merits of presently used analytical methods and instrumentation, and attempts to critically assess their limitations. In Sections 2 and 3, mass spectrometric methods applied to precise stable isotope analysis and to the determination of 41Ca are described. Section 4 contains a short summary of selected applications, and includes tracer experiments and the potential use of biological isotope fractionation in medical studies, paleoclimatic and paleoceanographic, and other terrestrial as well as extraterrestrial investigations. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:685–716, 2010