Andrew Cartwright
Research Subjects
Andrew Cartwright has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Damien McAleer
Randox Laboratories GmbH, Wilhelmstr, 147a, 42489, Wulfrath, Germany
1 shared publication - Ferdinand von Eggeling
Department of Otorhinolaryngology, Jena University Hospital, Jena, Germany
1 shared publication - Hans-Peter Bruch
Klinik für Chirurgie, Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Deutschland
1 shared publication - Hermann Brenner
Cancer Prevention Graduate School, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
1 shared publication - Jens Karsten Habermann
Section for Translational Surgical Oncology & Biobanking, Department of Surgery, University of Lübeck and University Hospital Schleswig-Holstein, 23562 Lübeck, Germany
1 shared publication - Jürgen Büning
Dermatology, University Hospital Schleswig-Holstein, Campus Lübeck
1 shared publication
Latest Publications
- Open Access
- 7 September 2012
- Published by Springer Nature in BMC Cancer
- Vol. 12 (1) , 393
A novel multiplex-protein array for serum diagnostics of colon cancer: a case–control study
Background: More than 1.2 million new cases of colorectal cancer are reported each year worldwide. Despite actual screening programs, about 50% of the patients are diagnosed at advanced tumor stages presenting poor prognosis. Innovative screening tools could aid the detection at early stages and allow curative treatment interventions. Methods: A nine target multiplex serum protein biochip was generated and evaluated using a training- and validation-set of 317 highly standardized, liquid nitrogen preserved serum samples comprising controls, adenomas, and colon cancers. Results: Serum levels of CEA, IL-8, VEGF, S100A11, MCSF, C3adesArg, CD26, and CRP showed significant differences between cases and controls. The largest areas under the receiver operating characteristics curve were observed for CEA, IL-8, and CRP. At threshold levels yielding 90% specificity, sensitivities for CEA, IL-8 and CRP were 26%, 22%, and 17%, respectively. The most promising marker combinations were CEA + IL-8 reaching 37% sensitivity at 83% specificity and CEA + CRP with 35% sensitivity at 81% specificity. In an independent validation set CEA + IL-8 reached 47% sensitivity at 86% specificity while CEA + CRP obtained 39% sensitivity at 86% specificity. Early carcinomas were detected with 33% sensitivity for CEA + IL-8 and 28% for CEA + CRP. Conclusions: Apart from CEA, IL-8, and CRP, the screening value of additional blood markers and the potential advantage of combining serum biochip testing with fecal occult blood testing needs to be studied. Multiplex biochip array technology utilizing serum samples offers an innovative approach to colorectal cancer screening.
- 7 September 2012
- Published by Springer Nature in BMC Cancer
- Vol. 12 (1) , 393
Open AccessA novel multiplex-protein array for serum diagnostics of colon cancer: a case–control study
Background: More than 1.2 million new cases of colorectal cancer are reported each year worldwide. Despite actual screening programs, about 50% of the patients are diagnosed at advanced tumor stages presenting poor prognosis. Innovative screening tools could aid the detection at early stages and allow curative treatment interventions. Methods: A nine target multiplex serum protein biochip was generated and evaluated using a training- and validation-set of 317 highly standardized, liquid nitrogen preserved serum samples comprising controls, adenomas, and colon cancers. Results: Serum levels of CEA, IL-8, VEGF, S100A11, MCSF, C3adesArg, CD26, and CRP showed significant differences between cases and controls. The largest areas under the receiver operating characteristics curve were observed for CEA, IL-8, and CRP. At threshold levels yielding 90% specificity, sensitivities for CEA, IL-8 and CRP were 26%, 22%, and 17%, respectively. The most promising marker combinations were CEA + IL-8 reaching 37% sensitivity at 83% specificity and CEA + CRP with 35% sensitivity at 81% specificity. In an independent validation set CEA + IL-8 reached 47% sensitivity at 86% specificity while CEA + CRP obtained 39% sensitivity at 86% specificity. Early carcinomas were detected with 33% sensitivity for CEA + IL-8 and 28% for CEA + CRP. Conclusions: Apart from CEA, IL-8, and CRP, the screening value of additional blood markers and the potential advantage of combining serum biochip testing with fecal occult blood testing needs to be studied. Multiplex biochip array technology utilizing serum samples offers an innovative approach to colorectal cancer screening.