KWKwok Chuen Wong

Kwok Chuen Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kwok Chuen Wong has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Associations between Lifestyle Factors and Neurocognitive Impairment among Chinese Adolescent and Young Adult (AYA) Survivors of Sarcoma

    by Yin Ting Cheung, Chung Tin Ma, Michael Can Heng Li, Keary Rui Zhou, Herbert Ho Fung Loong, Agnes Sui Yin Chan, Kwok Chuen Wong, Chi Kong Li

    Background: The effect of lifestyle on neurocognitive impairment among cancer survivors remain an understudied area. This study explored the association between lifestyle factors and neurocognitive outcomes (specifically, attention, memory, processing speed and cognitive flexibility) in AYA survivors (aged 15–39 years) of sarcoma. Methods: This study recruited 116 AYA survivors (age 28.2 (SD = 8.2) years), who were diagnosed with osteosarcoma (49%) or soft-tissue sarcoma (51%) at age 13.3 (SD = 7.2) years. The neurocognitive battery included measures of attention, memory, motor-processing speed, and cognitive flexibility. Survivors reported health-damaging practices, which included: physical inactivity, smoking, alcohol intake, inadequate sleep (9 h/day). General linear modeling was conducted to examine the association between lifestyle factors and neurocognitive outcomes, adjusting for age at diagnosis, sex, education attainment and clinical/treatment variables. Results: At 14.9 (SD = 7.6) years post-diagnosis, survivors demonstrated impairment in attentiveness (4.3–13.0%), processing speed (34.5%) and cognitive flexibility (18.1%). Nearly half (45.7%) had developed a chronic health condition (CHC). Low physical activity (estimate = −0.97, p = 0.003) and sleep-related fatigue (estimate = −0.08, p = 0.005) were associated with inattention. Survivors who worked >9 h/day (n = 15) demonstrated worse attention (estimate = 5.42, p = 0.023) and cognitive flexibility (estimate = 5.22, p = 0.005) than survivors who worked ≤9 h/day (n = 66). Interaction analysis (CHCs*physical activity) showed that survivors who developed CHCs and reported low physical activity had worse attention (p = 0.032) and cognitive-flexibility (p = 0.019) scores than other subgroups. Conclusion: Treatment-related CHCs, coupled with continued physical inactivity, may exacerbate inattention and executive dysfunction among survivors. Long working hours and sleep-related fatigue are associated with worse functioning; this finding should be validated with prospective assessment of work-related stressors and objective sleep measures.


  • Pelvic reconstruction after partial acetabular resection of bone sarcoma

    by Kwok-Chuen Wong, Xiaohui Niu, Hairong Xu, Yuan Li, Shekhar Madhukar Kumta

    Tumour surgeons have to achieve a negative resection margin for the best oncological outcomes with the reduced risk of local recurrence and improved patient survival. Given that the pelvic bone has a complex geometry with intricately related vital neurovascular structures, surgeons may resect tumours with more margin than oncologically necessary when taking into account the inaccuracy in planning and resection. The lesser normal bone may be retained for reconstruction to restore limbs function. Therefore, bone sarcoma locating near the acetabulum is often resected including the entire acetabulum. Partial acetabular resection of bone sarcoma with pelvic reconstruction has been described in selected patients with periacetabular tumours in a few case series. Early promising results were reported with the advantages of preserving more host bone for reconstruction without compromising the oncological resection margin and increasing the risk of local recurrence when the surgeries were performed with good preoperative planning and guided resection under computer navigation guidance. This article is to review the pelvic reconstruction after partial acetabular resection of bone sarcoma, its pathoanatomy, surgical considerations, current evidence and limitations.

  • Open Access

    Computer Navigation in Orthopaedic Tumour Surgery

    by Kwok-Chuen Wong, Xiaohui Niu, Hairong Xu, Yuan Li, Shekhar Kumta

    In orthopaedic bone tumour surgery, surgeons perform malignant bone tumour resections with tumour-free margin. The bone defects following the resections have to be reconstructed to restore limb function. An inaccurate resection with positive surgical margin increased the risk of local recurrence and compromised patients’ survival. Conventionally, orthopaedic tumour surgeons analyse two-dimensional (2D) imaging information and mentally integrate to formulate a three-dimensional (3D) surgical plan. It is difficult to translate the surgical plan to the operating room in complex cases. Computer-assisted tumour surgery (CATS) has been developed in orthopaedic oncology for the last decade. The technique may enable surgeons’ 3D surgical planning and image-guided bone resection as planned. The technique may apply to difficult surgery in pelvic or sacral tumours, limited resection in joint-preserving tumour surgery or bone defect reconstruction using CAD prostheses or allograft. Early results suggested that the technique may help in safe tumour resection and improve surgical accuracy by replicating the preoperative planning. The improved surgical accuracy may offer clinical benefits. Surgeons have to be aware of the potential errors of the technique that may result in inaccurate bone resections with possible adverse clinical outcomes. Given that bone sarcoma is rare, the published reports from different tumour centres could only analyse relatively small patient population with the heterogeneous histological diagnosis. Multicentre comparative studies with long-term follow-up are necessary to confirm its clinical efficacy. This chapter provides an overview of computer navigation in orthopaedic tumour surgery over the past decade. It (1) describes the current workflow, (2) reports the clinical indications and results and (3) discusses its limitations and future development.


  • Open Access

    Additive manufactured metallic implants for orthopaedic applications

    by Kwok-Chuen Wong, Peter Scheinemann


  • Open Access

    3D-printed patient-specific applications in orthopedics

    by Kwok Chuen Wong

    With advances in both medical imaging and computer programming, two-dimensional axial images can be processed into other reformatted views (sagittal and coronal) and three-dimensional (3D) virtual models that represent a patients’ own anatomy. This processed digital information can be analyzed in detail by orthopedic surgeons to perform patient-specific orthopedic procedures. The use of 3D printing is rising and has become more prevalent in medical applications over the last decade as surgeons and researchers are increasingly utilizing the technology’s flexibility in manufacturing objects. 3D printing is a type of manufacturing process in which materials such as plastic or metal are deposited in layers to create a 3D object from a digital model. This additive manufacturing method has the advantage of fabricating objects with complex freeform geometry, which is impossible using traditional subtractive manufacturing methods. Specifically in surgical applications, the 3D printing techniques can not only generate models that give a better understanding of the complex anatomy and pathology of the patients and aid in education and surgical training, but can also produce patient-specific surgical guides or even custom implants that are tailor-made to the surgical requirements. As the clinical workflow of the 3D printing technology continues to evolve, orthopedic surgeons should embrace the latest knowledge of the technology and incorporate it into their clinical practice for patient-specific orthopedic applications. This paper is written to help orthopedic surgeons stay up-to-date on the emerging 3D technology, starting from the acquisition of clinical imaging to 3D printing for patient-specific applications in orthopedics. It 1) presents the necessary steps to prepare the medical images that are required for 3D printing, 2) reviews the current applications of 3D printing in patient-specific orthopedic procedures, 3) discusses the potential advantages and limitations of 3D-printed custom orthopedic implants, and 4) suggests the directions for future development. The 3D printing technology has been reported to be beneficial in patient-specific orthopedics, such as in the creation of anatomic models for surgical planning, education and surgical training, patient-specific instruments, and 3D-printed custom implants. Besides being anatomically conformed to a patient’s surgical requirement, 3D-printed implants can be fabricated with scaffold lattices that may facilitate osteointegration and reduce implant stiffness. However, limitations including high cost of the implants, the lead time in manufacturing, and lack of intraoperative flexibility need to be addressed. New biomimetic materials have been investigated for use in 3D printing. To increase utilization of 3D printing technology in orthopedics, an all-in-one computer platform should be developed for easy planning and seamless communications among different care providers. Further studies are needed to investigate the real clinical efficacy of 3D printings in orthopedic applications.


  • Computer-assisted Tumor Surgery in Malignant Bone Tumors

    by Kwok Chuen Wong, Shekhar Madhukar Kumta

    Small recent case series using CT-based navigation suggest such approaches may aid in surgical planning and improve accuracy of intended resections, but the accuracy and clinical use have not been confirmed. We therefore evaluated (1) the accuracy; (2) recurrences; and (3) function in patients treated by computer-assisted tumor surgery (CATS). From 2006 to 2009, we performed CATS in 20 patients with 21 malignant tumors. The mean age was 31 years (range, 6–80 years). CT and MR images for 18 cases were fused using the navigation software. Reconstructed two-dimensional/three-dimensional images were used to plan the bone resection. The achieved bone resection was compared with the planned one by assessing margins, dimensions at the level of bone resection, or fitting of CAD custom prostheses. Function was assessed with the Musculoskeletal Tumor Society (MSTS) score. The minimum followup was 31 months (mean, 39 months; range, 5–69 months). Results Histological examination of all resected specimens showed a clear tumor margin. The achieved bone resection matched the planned with a difference of ≤ 2 mm. The achieved positions of custom prostheses were comparable to the planned positions when merging postoperative with preoperative CT images in five cases. Three of the four patients with local recurrence had tumors at the sacral region. The mean MSTS score was 28 (range, 23–30). CATS with image fusion allows accurate execution of the intended bone resection. It may be beneficial to resection and reconstruction in pelvic, sacral tumors and more difficult joint-preserving intercalated tumor surgery. Comparative clinical studies with long-term followup are necessary to confirm its efficacy. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


  • Joint-preserving Tumor Resection and Reconstruction Using Image-guided Computer Navigation

    by Kwok Chuen Wong, Shekhar Madhukar Kumta

    Joint-preserving surgery is performed in select patients with bone sarcomas of extremities and allows patients to retain the native joint with better joint function. However, recurrences may relate to achieving adequate margins and there is frequently little room for error in tumors close to the joint surface. Further, the tumor margin on preoperative CT and/or MR images is difficult to transpose to the actual extent of tumor in the bone in the operating room. We therefore determined whether joint-preserving tumor surgery could be performed accurately under image-guided computer navigation and determined local recurrences, function, and complications. We retrospectively studied eight patients with bone sarcoma of extremities treated surgically by navigation with fused CT-MR images. We assessed the accuracy of resection in six patients by comparing the cross sections at the resection plane with complementary prosthesis templates. Mean age was 17 years (range, 6–46 years). Minimum followup was 25 months (mean, 41 months; range, 25–60 months). The achieved resection was accurate, with a difference of 2 mm or less in any dimension compared to that planned in patients with custom prostheses. We noted no local recurrence at latest followup. The mean Musculoskeletal Tumor Society score was 29 (range, 28–30). There were no complications related to navigation planning and procedures. There was no failure of fixation at the remaining epiphysis. In selected patients, the computer-assisted approach facilitates precise planning and execution of joint-preserving tumor resection and reconstruction. Further followup assessment in a larger study population is required in these patients. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Use of a patient-specific CAD/CAM surgical jig in extremity bone tumor resection and custom prosthetic reconstruction

    by K.C. Wong, S.M. Kumta, K.Y. Sze, C.M. Wong

    Computer navigation has recently been introduced for bone tumor surgery in the orthopedic field, with the aim of achieving increased accuracy and precision in tumor resection and in custom prosthetic reconstruction. However, the technique requires bulky navigation facilities, the presence of a system operator in the operating room, and surgeons with prior experience in navigated surgery. We describe a new and simple method of using a patient-specific computer-aided design/computer-aided modeling (CAD/CAM) surgical jig to realize the preoperative planning in the surgical field. The accuracy of the proposed method was first tested in a cadaver trial. It took one minute to set the location of the jig prior to the bone resection and three minutes to perform the bone resections via the cutting slits of the jig. The dimensional difference between the achieved and planned bone resection was <1 mm on validation with the help of a junctional plate and a navigation system. The technique was then applied successfully to a patient with a low-grade osteosarcoma of the femur. An intercalated tumor resection was performed using a patient-specific surgical jig, and a custom CAD prosthesis reconstruction matched accurately to the skeletal defect. Further assessment in a larger population is necessary to determine the clinical efficacy of the technique.