Beng Hai Lee
Research Subjects
Beng Hai Lee has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jiang Liu
Institute for Infocomm Research, Agency for Science, Technology and Research
3 shared publications - Jun Cheng
Institute for Infocomm Research, A*STAR, Singapore, Singapore
3 shared publications - Damon Wing Kee Wong
Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
2 shared publications - Ee Ping Ong
Institute for Infocomm Research, Singapore
2 shared publications - Guozhen Xu
Technology and Research (A*STAR)
2 shared publications - Jimmy Addison Lee
Technology and Research (A*STAR)
2 shared publications
Latest Publications
- 20 November 2015
- Published by Springer Nature
- p. 214-221
Registration of Color and OCT Fundus Images Using Low-dimensional Step Pattern Analysis
- 20 November 2015
- Published by Springer Nature
- p. 214-221
Registration of Color and OCT Fundus Images Using Low-dimensional Step Pattern Analysis
- 20 November 2015
- Published by Springer Nature
- p. 329-337
A Robust Outlier Elimination Approach for Multimodal Retina Image Registration
- 20 November 2015
- Published by Springer Nature
- p. 329-337
A Robust Outlier Elimination Approach for Multimodal Retina Image Registration
- Open Access
- 1 August 2012
- Published by Springer Nature in BMC Medical Imaging
- Vol. 12 (1) , 25
Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty)
Background: The CorneaL GrAft Thickness Evaluation (COLGATE) system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers. Methods: This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC) independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement. Results: There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962). Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963) and 0.967 (95% CI 0.942 to 0.981) for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969). The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949) and 0.968 (95% CI 0.945 to 0.982) for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003). The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts. Conclusion: The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.
- 1 August 2012
- Published by Springer Nature in BMC Medical Imaging
- Vol. 12 (1) , 25
Open AccessReproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty)
Background: The CorneaL GrAft Thickness Evaluation (COLGATE) system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers. Methods: This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC) independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement. Results: There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962). Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963) and 0.967 (95% CI 0.942 to 0.981) for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969). The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949) and 0.968 (95% CI 0.945 to 0.982) for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003). The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts. Conclusion: The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 3037-3040
Corneal graft detection for Descemet's Stripping Automated Endothelial Keratoplasty using Optical Coherence Tomography
The cornea is the window of the eye and when it is severely damaged or diseased, vision is impaired. Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) is a surgical procedure to replace the malfunctioned Descemet's membrane with a healthy one in order to restore the patient's sight. After the operation, ophthalmologists need to monitor the grafted membrane to check for signs of detachment, rejection, etc. and take appropriate actions before graft failure occurs. In this paper, we introduce the COrneaL GrAft Thickness Evaluation (COLGATE) System that we developed for ophthalmologists for the evaluation of the transplanted corneal graft. We discuss the various components in our system and methods we developed. Experiments are conducted and the results are m 1 = 7.5% and m 2 = 7.2%.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 3037-3040
Corneal graft detection for Descemet's Stripping Automated Endothelial Keratoplasty using Optical Coherence Tomography
The cornea is the window of the eye and when it is severely damaged or diseased, vision is impaired. Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) is a surgical procedure to replace the malfunctioned Descemet's membrane with a healthy one in order to restore the patient's sight. After the operation, ophthalmologists need to monitor the grafted membrane to check for signs of detachment, rejection, etc. and take appropriate actions before graft failure occurs. In this paper, we introduce the COrneaL GrAft Thickness Evaluation (COLGATE) System that we developed for ophthalmologists for the evaluation of the transplanted corneal graft. We discuss the various components in our system and methods we developed. Experiments are conducted and the results are m 1 = 7.5% and m 2 = 7.2%.