KKKai Ke

Kai Ke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kai Ke has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electric-field mask electrospinning enabled elastomer mats with a biomimic pore micro-structure for permeable and robust ultrathin e-skins

    by Liming Wu, Yu-Jie Wu, Qi Jing, Sijie Chen, Ruixing He, Zihao Wang, Lan Jiang, Kai Ke, Jun-Hong Pu, Kai Zhang, et al.

    Inspired by the Cyperus rotundus leaf epidermis, electric-field mask electrospinning is proposed to fabricate ultrathin, mechanically robust, and highly breathable film strain sensors for sweat-resistant healthcare and body motion monitoring.

  • Boosting Piezoelectricity and Mechanical Properties of Silk Fibroin Films via Polyethylene Glycol Phase Manipulation

    by Mu-Han Chen, Yi-Di Hu, Yu-Jie Wu, Jia-Xing Guo, Kai Ke, Yu Wang, Bo Yin, Wei Yang

    Piezoelectric silk fibroin (SF) shows great potential in fabricating sustainable wearable electronics toward health monitoring and human–machine interfacing, yet the processing difficulty and brittleness restrict its practical applications severely. This study proposes a simple strategy to achieve the boosted piezoelectricity and mechanical properties in electrospun regenerated silk fibroin (RSF) nanofiber mats by adding polyethylene glycol (PEG) with different molecular weights to induce the formation of β-sheets via hydrogen bonding and the regulation of PEG phase morphology. Specifically, RSFs consisting of PEG of 2000 and 1000 Da exhibit a significant improvement in the tensile strength (from 6.1 to 9.92 MPa) and elongation at break (from 5.72% to 117.58%), respectively. Meanwhile, RSFs consisting of PEG with a molecular weight of 2000 and 400 Da show a direct piezoelectric force sensitivity of 0.2 mV/N·μm and 0.14 mV/N·μm respectively, superior to that of pure RSF (0.04 mV/N·μm). The piezoelectric force sensors fabricated with RSFs show potential applications in the detection of diverse human motions, including finger tapping for Morse code, grip strength, and knee flexion. Thus, this work unveils a facile strategy to fabricate RSF-based biodegradable piezoelectric force sensors with a trade-off in processability, mechanical ductility, and piezoelectricity.


  • Basalt fibers with surface-coated hybrid carbon nanofillers for linear temperature and pressure sensing

    by Yanhua Sun, Jiaxing Guo, Yidi Hu, Muhan Chen, Lei Jing, Rui-Ying Bao, Kai Ke, Yu Wang, Bo Yin, Wei Yang

    A synergistic surface modification strategy enables fabricating BF-based composites with a conductivity of ∼230 S m −1 , TCR of 0.18% per °C, excellent signal linearity ( R 2 > 0.999) within 30–150 °C, and linear pressure sensing within 0–0.5 MPa.

  • Open Access

    Flash annealing boosts piezoelectricity of PVDF-TrFE

    by Yi-Di Hu, Chun-Yan Tang, Shuang-Jun Li, Yu-Jie Wu, Kai Ke, Ran Chen, Chuanfu Luo, Quan-Xiao Dong, Hong-Xiang Li, Lu Bai, et al.

    Annealing increases β-phase crystal contents of poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE), thus improving its ferroelectricity and piezoelectricity. However, most studies focus on improving piezoelectricity of wet-processed PVDF-TrFE via long-time annealing. Here, we report a flash annealing strategy to boost piezoelectricity of PVDF-TrFE at a temperature above its Curie temperature, which has never been reported for polymer processing. Specifically, electrospun PVDF-TrFE fiber mats show a piezoelectric coefficient d33 of −70.89 pm/V or −68 pC/N after flash annealing, which are superior to that of the mats annealed for 2 h. Besides, the mechanisms for an improvement of β-phase crystal content during flash annealing was interpreted by in-situ Raman spectroscopy, XRD, Fourier transform infrared spectroscopy, and molecular dynamics simulation. The as-fabricated piezoelectric films show promising applications in energy harvesting, high-frequency vibration. It unveils an intriguing way to significantly boost intrinsic piezoelectricity of PVDF-TrFE toward developing advanced flexible electronics and micro-electro-mechanical systems.


  • Open Access

    Silk fibroin-based flexible pressure sensors: processing and application

    by Muhan Chen, Junhong Liu, Yidi Hu, Yujie Wu, Chun-Yan Tang, Kai Ke, Wei Yang

    With the advent of the internet of things and artificial intelligence, flexible and portable pressure sensors have shown great application potential in human-computer interaction, personalized medicine and other fields. By comparison with traditional inorganic materials, flexible polymeric materials conformable to the human body are more suitable for the fabrication of wearable pressure sensors. Given the consumption of a huge amount of flexible wearable electronics in near future, it is necessary to turn their attention to biodegradable polymers for the fabrication of flexible pressure sensors toward the development requirement of green and sustainable electronics. In this paper, the structure and properties of silk fibroin (SF) are introduced, and the source and research progress of the piezoelectric properties of SF are systematically discussed. In addition, this paper summarizes the advance in the studies on SF-based capacitive, resistive, triboelectric, and piezoelectric sensors reported in recent years, and focuses on their fabrication methods and applications. Finally, this paper also puts forward the future development trend of high-efficiency fabrication and corresponding application of SF-based piezoelectric sensors. It offers new insights into the design and fabrication of green and biodegradable bioelectronics for in vitro and in vivo sensing applications.


  • Linear Film Strain Sensors with Nanosphere‐on‐Fiber Hetero‐Modulus Microstructure for Human‐Bionic Finger Interfacing

    by Kai‐Dong Wei, He‐Qing Shao, Kai Ke, Bo Yin, Ming‐Bo Yang, Wei Yang

    Stretchable film strain sensors show potential applications in healthcare and human‐machine interfacing, while poor signal linearity restricts their practical applications owing to inaccurate and instable strain indication. Signal sensitivity and linearity can be improved via constructing hetero‐modulus microstructure on elastomeric substrate to some extent, though it is challenging to construct hetero‐structure with distinct modulus differences for electrical signal linearity modulation over a wide strain range. Herein, a simple strategy is proposed to tune signal sensitivity, linearity, and detection range of stretchable strain sensors by adjusting the distribution of rigid polystyrene (PS) nanospheres coated on electrospun thermoplastic polyurethane (TPU) fiber mats. Heterostructure characteristics can be controlled by spray coating times of PS nanospheres, which are immobilized onto the fiber mats by weak swelling of TPU and the linking layer of reduced graphene oxide (rGO) between TPU and PS induced by hydrogen bonding and π–π stacking. Relatively, the sensors with moderate spray coating times of PS nanospheres show balanced signal sensitivity and linearity over a strain range of 0–80%, as well as fast response to tensile strain and good signal reproducibility. Such elastomeric film strain sensors can be used for monitoring physiological activities and interfacing human hand and bionic fingers.


  • Elastic Janus Microarray Film Strain Sensors with Heterogeneous Modulus and Conductivity for Healthcare and Braille Identification

    by He‐Qing Shao, Kai‐Dong Wei, Tao Gong, Jin Jia, Chun‐Yan Tang, Xiang‐Jun Zha, Kai Ke, Rui‐Ying Bao, Kai Zhang, Yu Wang, et al.

    Most stretchable film strain sensors generally present nonlinear electrical responses to applied strain, leading to an inaccurate acquisition of sophisticated signals, difficult signal processing, and zero‐calibration, which hampers practical applications severely. Here, a Janus hetero‐structured microarray film sensor is developed by in‐situ growth of silver nanoparticles on the surface of micro‐patterned elastomer films fabricated via low‐temperature imprinting followed by scraping‐induced particle trapping. Heterogeneous property designs in both modulus and electrical conductivity via introducing polymer microarrays enable modulating the electron transport manner in the conductive layer of elastic Janus films upon stretching, allowing to tune signal linearity effectively. Therefore, such a hetero‐structured film sensor shows good signal linearity (fluctuation of gauge factor [GF] below ±0.02) and relatively high sensitivity (GF > 10) within 55% strain, a detection limit of 0.2% strain, and a response/recovery time of 16.3/46.9 ms, respectively. Correspondingly, it enables monitoring human respiration and body motion with higher resolution compared with the nonlinear one, meanwhile, it is capable of detecting tiny pressure to discriminate braille alphabets via touch identification. Overall, it unveils a simple strategy to fabricate film strain sensors for high‐resolution healthcare and body motion monitoring, as well as electronic skins toward tactile sensing and touch identification.


  • Electro-microenvironment modulated inhibition of endogenous biofilms by piezo implants for ultrasound-localized intestinal perforation disinfection

    by Xing Zhao, Li-Ya Wang, Chun-Yan Tang, Kai Li, Yan-Hao Huang, Yan-Ran Duan, Shu-Ting Zhang, Kai Ke, Bai-Hai Su, Wei Yang


  • Recent Advances in Multiresponsive Flexible Sensors towards E‐skin: A Delicate Design for Versatile Sensing

    by Wu‐Di Li, Kai Ke, Jin Jia, Jun‐Hong Pu, Xing Zhao, Rui‐Ying Bao, Zheng‐Ying Liu, Lu Bai, Kai Zhang, Ming‐Bo Yang, et al.

    Multiresponsive flexile sensors with strain, temperature, humidity, and other sensing abilities serving as real electronic skin (e‐skin) have manifested great application potential in flexible electronics, artificial intelligence (AI), and Internet of Things (IoT). Although numerous flexible sensors with sole sensing function have already been reported since the concept of e‐skin, that mimics the sensing features of human skin, was proposed about a decade ago, the ones with more sensing capacities as new emergences are urgently demanded. However, highly integrated and highly sensitive flexible sensors with multiresponsive functions are becoming a big thrust for the detection of human body motions, physiological signals (e.g., skin temperature, blood pressure, electrocardiograms (ECG), electromyograms (EMG), sweat, etc.) and environmental stimuli (e.g., light, magnetic field, volatile organic compounds (VOCs)), which are vital to real‐time and all‐round human health monitoring and management. Herein, this review summarizes the design, manufacturing, and application of multiresponsive flexible sensors and presents the future challenges of fabricating these sensors for the next‐generation e‐skin and wearable electronics.


  • Aligned wave-like elastomer fibers with robust conductive layers via electroless deposition for stretchable electrode applications

    by Yan Li, Yi Chen, Yi Yang, Jun-Di Gu, Kai Ke, Bo Yin, Ming-Bo Yang

    Flexible wearable electronics play an important role in the healthcare industry due to their unique skin affinity, portability and breathability. Despite great progress, it still remains a big challenge to facilely fabricate stretchable electrodes with low resistance, excellent stability and a wide tensile range. Here, we propose a handy and time-saving strategy for the fabrication of elastomeric films consisting of wave-like fibers with a robust conductive layer of silver nanoparticles (AgNPs) immobilized using polydopamine (PDA) and silicone rubber (SR). To realize better stretchability, electrospun thermoplastic polyurethane (TPU) mats with oriented nanofibers were treated via ethanol to achieve a wavy structure, which also allowed for the decoration of AgNP precursors on the TPU surface via PDA assisted electroless deposition (ELD). Therefore, the electrodes achieved a stretchability of 120% with high electrical conductivity (486 S cm−1). The films with a reduction time of 30 min showed superior electrical conductivity indicated by a resistance increase of only 100% within 50% strain. The TPU/PDA/AgNP/SR composites with a shorter reduction time of silver precursors could monitor human motions as wearable strain sensors with a wide work strain range (0–98%) and a high sensitivity (with a gauge factor (GF) of up to 81.76) for a strain of 80–98%. Therefore, they are an excellent candidate for potential application in prospective stretchable electronics.