AKAkihiro Kikuchi

Akihiro Kikuchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Akihiro Kikuchi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroyuki Horikoshi

    Department of Diagnostic Radiology, Gunma Prefectural Cancer Center, Takabayashi Nishimachi 617-1, Ota, Gunma, 373-0828, Japan

    1 shared publication
  • Karl Sjöstrand

    Informatics and Mathematical Modeling, Technical University of Denmark, Copenhagen, Denmark

    1 shared publication
  • Lars Edenbrandt

    Department of Molecular and Clinical Medicine, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden

    1 shared publication
  • Masahisa Onoguchi

    Division of Health Sciences, Graduate School of Medical Science, School of Health Sciences, College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan

    1 shared publication

Latest Publications

  • Open Access

    Computer-aided diagnosis system for bone scintigrams from Japanese patients: importance of training database

    by Hiroyuki Horikoshi, Akihiro Kikuchi, Masahisa Onoguchi, Karl Sjöstrand, Lars Edenbrandt

    Aim Computer-aided diagnosis (CAD) software for bone scintigrams have recently been introduced as a clinical quality assurance tool. The purpose of this study was to compare the diagnostic accuracy of two CAD systems, one based on a European and one on a Japanese training database, in a group of bone scans from Japanese patients. Method The two CAD software are trained to interpret bone scans using training databases consisting of bone scans with the desired interpretation, metastatic disease or not. One software was trained using 795 bone scans from European patients and the other with 904 bone scans from Japanese patients. The two CAD softwares were evaluated using the same group of 257 Japanese patients, who underwent bone scintigraphy because of suspected metastases of malignant tumors in 2009. The final diagnostic results made by clinicians were used as gold standard. Results The Japanese CAD software showed a higher specificity and accuracy compared to the European CAD software [81 vs. 57 % (p < 0.05) and 82 vs. 61 % (p < 0.05), respectively]. The sensitivity was 90 % for the Japanese CAD software and 83 % for the European CAD software (n.s). Conclusion The CAD software trained with a Japanese database showed significantly higher performance than the corresponding CAD software trained with a European database for the analysis of bone scans from Japanese patients. These results could at least partly be caused by the physical differences between Japanese and European patients resulting in less influence of attenuation in Japanese patients and possible different judgement of count intensities of hot spots.