  • HRV analysis and blood pressure monitoring on weighing scale using BCG

    by Jae Hyuk Shin, Kwang Suk Park

    Using the Ballistocardiogram(BCG) measured on weighing scale, heart rate variability(HRV) and blood pressure were estimated. BCG was measured while subjects were on weighing scale in resting state and under the Valsalva maneuver and static exercise condition to induce the change in cardiac autonomic rhythm. Time domain, frequency domain and nonlinear HRV parameters were estimated from the measured BCG and compared with the ones calculated from ECG measured simultaneously. For blood pressure(BP) estimation, ECG was measured additionally on the feet using dry electrodes simultaneously installed on weighing scale and R-J intervals were extracted as a BP correlated parameter at every beat cycle. HRV estimation results shows the correlation higher than 0.97, and the estimated BP was similar to the measured BP with a reliable correlations.


  • Open Access

    Sleep/wake estimation using only anterior tibialis electromyography data

    by SuHwan Hwang, GihSung Chung, JeongSu Lee, JaeHyuk Shin, So-Jin Lee, Do-Un Jeong, KwangSuk Park

    In sleep efficiency monitoring system, actigraphy is the simplest and most commonly used device. However, low specificity to wakefulness of actigraphy was revealed in previous studies. In this study, we assumed that sleep/wake estimation using actigraphy and electromyography (EMG) signals would show different patterns. Furthermore, each EMG pattern in two states (sleep, wake during sleep) was analysed. Finally, we proposed two types of method for the estimation of sleep/wake patterns using only EMG signals from anterior tibialis muscles and the results were compared with PSG data. Seven healthy subjects and five patients (2 obstructive sleep apnea, 3 periodic limb movement disorder) participated in this study. Night time polysomnography (PSG) recordings were conducted, and electrooculogram, EMG, electroencephalogram, electrocardiogram, and respiration data were collected. Time domain analysis and frequency domain analysis were applied to estimate the sleep/wake patterns. Each method was based on changes in amplitude or spectrum (total power) of anterior tibialis electromyography signals during the transition from the sleep state to the wake state. To obtain the results, leave-one-out-cross-validation technique was adopted. Total sleep time of the each group was about 8 hours. For healthy subjects, the mean epoch-by-epoch results between time domain analysis and PSG data were 99%, 71%, 80% and 0.64 (sensitivity, specificity, accuracy and kappa value), respectively. For frequency domain analysis, the corresponding values were 99%, 73%, 81% and 0.67, respectively. Absolute and relative differences between sleep efficiency index from PSG and our methods were 0.8 and 0.8% (for frequency domain analysis). In patients with sleep-related disorder, our proposed methods revealed the substantial agreement (kappa > 0.61) for OSA patients and moderate or fair agreement for PLMD patients. The results of our proposed methods were comparable to those of PSG. The time and frequency domain analyses showed the similar sleep/wake estimation performance.


  • Non-constrained monitoring of systolic blood pressure on a weighing scale

    by Jae Hyuk Shin, Kang Moo Lee, Kwang Suk Park

    In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured using three different methods: on the chest using Ag/AgCl electrodes, on the hands using dry electrodes and on the feet also using dry electrodes. For a BP correlated parameter, a time interval parameter, which was defined as the time difference between the ECG R-peak and BCG J-peak, was employed for evaluating and estimating beat-to-beat BP. Under a BP varying experiment with a Valsalva manoeuvre, the R-J intervals were extracted at every beat cycle and a systolic blood pressure (SBP) estimation equation was established using linear regression analysis for each subject. In the case of feet delivered ECG (F-ECG), an ensemble average technique synchronized at the BCG J-peak point was applied to extract the ECG signal from the feet. The performance of the proposed method was evaluated using Finapres, a non-invasive blood pressure measurement system, as a reference BP signal, and a scatter plot was used to find the regression line between the reference values and estimated BPs. A moving-window averaging technique was applied to remove the high-frequency noise in the R-J intervals and was applied to enhance the accuracy of the SBP estimation. For all individuals, the estimated SBP was similar to the measured SBP with a reliable correlation, which makes the proposed method suitable for use in a home healthcare system to monitor blood pressure on a weighing scale at the same time as measuring weight.


  • Automatic ballistocardiogram (BCG) beat detection using a template matching approach

    by J. H. Shin, B. H. Choi, Y. G. Lim, D. U. Jeong, K. S. Park

    This paper suggests a beat detection method for ballistocardiogram (BCG) from an unconstrained cardiac signal monitoring devices. A fiducial peak point of BCG is an I-J-K complex which corresponds with ventricle contraction and Electrocardiogram (ECG) QRS complex. The goal of the method is extraction of J peak without ECG synchronization. The detection method is based on a “template matching” rule evaluated using a correlation function in a local moving-window procedure. The total beat detection algorithm operates in two stages, template definition stage and beat detection stage with defined template in previous stage. In the first stage, the BCG template is constructed by the expert with an empirical analysis of BCG signal and measurement device. In the second stage, the correlation function calculates an accuracy of template with BCG signal using a local moving-window. The data analysis has been performed on the subjects tested at Seoul National University Hospital Sleep Medicine Center and presents 95.16% of sensitivity and 94.76% of positive predictivity value for the J peak detection.


  • A Multiparameter Wearable Workload Analysis System for Power Plant Operators

    by Jae Hyuk Shin, Youngjoon Chee, Myungsoo Lee, Kwang Suk Park

    In this paper, we present the wearable workload analysis system that is designed to evaluate the workload and mental stress of operators which employed on power plant. The hardware parts and software part of the wireless sensor system is described which plays an important role in workload analysis system. The software system processes ECG, respiration, EDA, activity signal and extracts some information about worker's conditions. The result of this experiment is reveal that our designed system is suitable for measuring psychophysiological signal from works by non-invasive and comfort method. And derived workload index equation is well reflect the work level and degree of mental stress.