LLLan Luo

Lan Luo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lan Luo has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Simultaneous measurement of magneto-optical rotation and ellipticity using dual-pointers weak measurement

    by Yifan Wang, Shushu Shi, Lan Luo, Weisheng Yue, Yunfei Luo, Sijie Zhang, Tong Li

    Magneto-optical (MO) effects, manifested as a complex rotation of light polarization under an external magnetic field, have found renewed and advanced applications in integrated photonics, intelligent sensing, ultrafast magnetic recording, and high-resolution magnetic imaging. Accurate measurement of both the rotation angle (the real part) and the ellipticity (the imaginary part) is essential for fundamental research and device applications. However, existing measurement schemes generally require separate measurements or distinct detection configurations and therefore cannot simultaneously retrieve both quantities in a single measurement. In this work, we propose a scheme based on weak measurement using dual-pointers, enabling the simultaneous measurement of the rotation angle and ellipticity within a single meter state. This method was theoretically and experimentally implemented to measure the magneto-optical Kerr effect (MOKE), the Faraday effect, and the Cotton-Mouton effect, demonstrating its broad applicability. This work contributes a characterization technique for the complex angle of MO effects, supporting potential applications across spintronics, quantum materials, and advanced optical sensing.

  • Open Access

    Breaking the trade-off between sensitivity and dynamic range in weak measurement via dual-mode intensity contrast ratio

    by Lan Luo, Tanfu Sun, Feifan He, Lin Ju, Yun Jiang, Bo Liu, Yifan Wang, Zhiyou Zhang

    Quantum weak measurement is constrained by an inherent trade-off: enhancing sensitivity inevitably restricts the linear dynamic range. Here, we propose a generalized dual-mode weak measurement scheme based on the dual-mode intensity contrast ratio (DICR) to overcome the fixed-window limitation associated with this trade-off. We theoretically demonstrate that the measurement performance is governed by two generalized dual-mode parameters: the mode half-separation and mean mode value. Experimentally, we apply this scheme to ultrasensitive polarimetry of chiral solutions. Results reveal that tuning the mean wavelength shifts the optimal measurement region, while reducing the wavelength half-separation significantly enhances the local sensitivity. Together, these results demonstrate that the DICR-based scheme enables flexible adjustment of the local sensitivity and measurement range, together with relocation of the optimal operating region, thereby overcoming the fixed-window constraint of standard weak measurement.

  • Open Access

    Three-Vector-Based Model Predictive Direct Speed Control Strategy for Enhanced Target Tracking in Risley Prism Systems

    by Hao Lu, Bo Liu, Jianwen Guo, Yuqi Shan, Hao Yi, Yun Jiang, Lan Luo, Feifan He, Taibei Liu, Zixun Wang, et al.

    When the Risley prism pair is used for target tracking, the nonlinear relationship between beam deflection and prism rotation makes tracking performance highly dependent on precise and stable motor control over a wide speed range. Although the brushless DC motor serves as the preferred drive source, its inherent commutation torque ripples directly induce beam pointing jitter, severely degrading overall tracking accuracy and stability. To address these issues, this paper proposes a three-vector-based model predictive direct speed control method. This approach establishes a direct speed-to-torque control channel by generating reference active power through dynamic equations, eliminating the need for fitting a constant flux linkage and parameter tuning. Simultaneously, combined with three-vector optimization and seven-segment modulation strategies, it achieves a dynamic balance between high-frequency, instantaneous electromagnetic power fine-tuning and inherent mechanical inertia of the rotor. Simulation results demonstrate that the proposed method exhibits superior speed stability compared to the conventional double-vector-based model predictive power control method and maintains high-precision dynamic tracking over a wide speed range. Ultimately, it leads to an average reduction of over 60% in the time-weighted absolute tracking error integral under various target trajectories, providing an effective solution for drive control of target tracking in Risley prism systems.

  • Hyperspectral Phase Imaging via Optical Differential Microscopy

    by Ling Ye, An Wang, Xiong Liu, Yurong Liu, Su Li, Lan Luo, Rongchun Ge, Zhiyou Zhang

    Edge detection is critical for emerging image processing technologies. Here, we present a dual-channel optical differential system that faithfully retrieves full edges of two-dimensional (2D) images. The system, leveraging the modified Wollaston prism, is compatible with hyperspectral imaging (HSI), enabling real-time phase imaging across 450-750 nm with 30 spectral channels. Experimental results demonstrate that the peak signal-to-noise ratio (PSNR) of the image is improved over 6 dB with the proposed system. Meanwhile, it indicates that edge imaging can achieve higher contrast on biological samples. This work demonstrates the system’s potential for wide applications like target recognition and image enhancement, laying the foundation for hyperspectral phase edge microscopy.

  • Complex signal measurement based on weak measurements

    by Lan Luo, Tong Li, Tianchen Li, Bo Liu, Yu He, Zhiyou Zhang

    In the application of weak measurements, such as the estimation of magnetic parameters, the purely real weak coupling of standard weak measurement (SWM) does not correspond to the true physical parameters. To accommodate more complex application scenarios, we further explore three different weak measurement models in which both complex weak coupling and complex weak values coexist. This paper theoretically analyzes pointer variations and applicable ranges in SWM, double pointer weak measurement (DPWM), and almost-balanced weak measurement (ABWM) under specific conditions. Notably, only ABWM can successfully distinguish the real and imaginary components of weak values under complex weak-coupling conditions. While SWM and DPWM can also solve for weak values, they fail to obtain a unique and correct test value. The ABWM technique provides a higher sensitivity than SWM when measuring extremely small parameters. Furthermore, we apply ABWM to the magneto-optical Kerr effect measurement of a Ni-Fe film. This research deepens the understanding of weak measurement techniques and introduces new methods for multiparameter measurements.


  • Ultrasensitive probing of nematic order parameter via weak measurement

    by Changyou Wang, Yunhan Wang, Yurong Liu, Tong Li, Lan Luo, Sijie Zhang, Zhiyou Zhang

    Nematic order parameter S is one of the most crucial material parameters of the nematic phase, which governs all of the material's anisotropic properties. The enhancement of its measurement precision has always been a great concern. In this Letter, a weak measurement scheme with a modified shift pointer is presented to achieve an ultrasensitive probe of S or the director's orientational angle θ. Using this scheme, we have demonstrated a real-time monitoring of the orientational process of cellulose nano-crystal molecules in solutions and measured the orientational direction of polymer nanowires. A typical precision on the order of 10−3 is achieved in the measurement of S and θ. Compared with the current existing techniques, the present scheme not only offers higher measurement precision but also maintains extreme cost-efficiency, thereby holding significance for the research of orientational materials and devices.


  • Open Access

    High-precision measurement of the complex magneto-optical Kerr effect using weak measurement

    by Tong Li, Yunhan Wang, Yinghang Jiang, Sijie Zhang, Lan Luo, Zhiyou Zhang

    The present paper introduces a quantum weak measurement (WM) scheme for the measurement of the complex magneto-optical Kerr effect (MOKE). We achieve the simultaneous measurement of the Kerr rotation angle and the ellipticity in a single WM process by utilizing two auxiliary pointers derived from the same meter state. The experimental measurement precision for both the Kerr rotation angle and the ellipticity is capable of reaching 10−4 deg. This technique is also employed for the determination of the complex magneto-optical constant Q. The proposed method overcomes the limitation of acquiring the complex magneto-optical Kerr parameters through a multi-step measurement process, which was previously encountered. This breakthrough holds immense significance for efficiently measuring and applying the complex MOKE with high precision and cost-effectiveness.


  • Open Access

    High-precision measurement of the complex magneto-optical Kerr effect using weak measurement

    by Tong Li, Yunhan Wang, Yinghang Jiang, Sijie Zhang, Lan Luo, Zhiyou Zhang

    The present paper introduces a quantum weak measurement (WM) scheme for the measurement of the complex magneto-optical Kerr effect (MOKE). We achieve the simultaneous measurement of the Kerr rotation angle and the ellipticity in a single WM process by utilizing two auxiliary pointers derived from the same meter state. The experimental measurement precision for both the Kerr rotation angle and the ellipticity is capable of reaching $10^{-4}$ deg. This technique is also employed for the determination of the complex magneto-optical constant $Q$. The proposed method overcomes the limitation of acquiring the complex magneto-optical Kerr parameters through a multi-step measurement process, which was previously encountered. This breakthrough holds immense significance for efficiently measuring and applying the complex MOKE with high precision and cost-effectiveness.

  • Weak-value amplified surface plasmon resonance sensor based on joint detection of optical activity and refractive index

    by Liping Xu, Xin Yao, Gang Wen, Jiangtao Xu, Lan Luo, Zhiyou Zhang, Hao Wu, Peng Wu, Tianying Chang, Hong-Liang Cui

    A versatile system combining surface plasmon resonance (SPR) and weak value amplification (WVA) is presented, which can measure the optical activity and refractive index of chiral/achiral molecules, ionic compounds, and their mixture in solution individually or simultaneously. The variations in output light intensity directly exhibit high sensitivity to changes in optical activity and refractive index of the aforementioned substances. Furthermore, by examining the correlation between the intensity variation trend and the optical activity of the chiral molecule, the molecule's absolute configuration can be ascertained. Utilizing this instrument, optical rotation with a resolution of 3.04 × 10−6 rad and refractive index with a resolution of 5.57 × 10−9 RIU were obtained. As an attempt at practical application, this sensor was used to detect the adulteration of glucose and fructose in pure honey. Not only can such compromised honey be distinguished from pure honey using the refractive index or optical rotation, but the difference in optical activity can also be employed to effectively differentiate between adulterated honey samples containing glucose and fructose separately.


  • Observation of the mixed magneto-optical Kerr effects using weak measurement

    by Tong Li, Lan Luo, Xinrui Li, Martin T. Dove, Sijie Zhang, Jianhong He, Zhiyou Zhang

    In this paper, we use weak measurement to study the mixed magneto-optical Kerr effects (MOKEs) in a magnetic single layer of Co and in organic/Co bilayer films. The relationship between the amplified shift and the MOKE parameters is theoretically established and then experimentally observed as a function of both the magnetization intensity and the magnetization direction in magnetic thin films with an arbitrary magnetization. Furthermore, we experimentally observe a magnetic coupling at the organic/ferromagnetic interface. Due to this being a robust coupling, there is a significant dependence of the amplified shift with the thickness of the organic layer. This work has value for its application in the magnetic measurement technique for the more general case based on weak measurement.