FYFeng Yi

Feng Yi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Feng Yi has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental setup for testing nanocalorimeter sensors as a plasma diagnostics tool

    by Carles Corbella, Feng Yi, Andrei Kolmakov

    The application of microfabricated nanocalorimeters for real-time, highly sensitive, and selective monitoring of the energy fluxes from low-pressure plasma discharges has been reported recently. Here, we describe the experimental setup for complementary characterization of nanocalorimeters’ performance using plasma diagnostics techniques. The Langmuir probe, retarding field energy analyzer, optical emission spectroscopy, quadrupole mass spectrometry, and thermocouple-based thermometry constitute the plasma monitor suite. We discuss two application examples of the plasma monitor suite: (1) discrimination between electron- and ion-induced heat fluxes via sensor direct current biasing, and (2) detection of fast temperature transients in pulsed discharges. The main goal of this work is to demonstrate a nanocalorimetry platform as a real-time metrology for plasma processing and process control.

  • Understanding microfabricated nanocalorimeter performance and responses to the energy fluxes from low-temperature plasma discharges

    by Carles Corbella, Feng Yi, Andrei Kolmakov

    Plasma diagnostics have a shortage of fast and sensitive calorimetric sensors that can track low-energy fluxes during plasma-assisted microfabrication. In this work, energy fluxes from argon and oxygen radio frequency (RF) glow discharges have been probed using a novel nanocalorimeter sensor. The probe consists of an ultrathin SiNx membrane (100 nm) with a lithographically defined Pt microstrip (100 nm) that serves as a calibrated resistance thermometer. The sensor temperature can increase from room temperature to several hundred degrees within a second upon exposure to RF plasma, depending on the experiment’s geometry and plasma parameters. Such sensitivity and response time are due to the predesigned reduced heat capacity of the sensor and significantly reduced thermal conductance of the cooling channels. These features enable the sensitive detection of low-energy plasma fluxes on surfaces and their rapid discrimination, as in the case of ion and electron fluxes, by biasing the sensor at negative or positive potentials. These biased nanocalorimeter energy readings have been compared with ion and electron kinetic energy dissipations assessed using a Langmuir probe and retarding field energy analyzer. Finally, the robustness of the plasma nanocalorimeter is discussed in terms of its baseline drifts, degradation, and longevity.


  • A nanocalorimeter designed for use with high-resolution transmission electron microscopy

    by Izak McGieson, Shane Q. Arlington, Lakshmi Ravi Narayan, William Osborn, Michael D. Grapes, Timothy P. Weihs, Melissa K. Santala, David A. LaVan, Feng Yi

    Nanocalorimetry is a thermal analysis technique utilizing microfabricated sensors capable of characterizing phase transformations and chemical reactions both isothermally or at fast heating and cooling rates when operated in a scanning mode. Here, a nanocalorimeter was designed to operate in a transmission electron microscope (TEM) holder compatible with TEMs with a narrow pole piece gap. The nanocalorimeters have an electrical connection design to enable in situ TEM observation during high-rate thermal measurements. Both 10 nm alumina and 20 nm silicon nitride membranes were realized as TEM observation windows, to allow for high resolution and high-speed imaging. For certain specimens, the nanocalorimeters may be fabricated with small perforations so the specimen may be imaged over vacuum without any support layer, as demonstrated for a 25 nm thick gold film. Elimination of the amorphous silicon nitride under the TEM observation region reduces the background signal. Preliminary measurements demonstrate the versatility of the nanocalorimeter for in situ TEM observation. Synchronizing nanocalorimetry with a high-frame-rate direct electron detector further extends the measurement capability to couple thermal analysis with the evolution of microstructure.


  • Open Access

    Abstracts of the 2023 49th Annual NATAS Conference

    by David LaVan, Feng Yi, Tina Adams, Ran Tao, Elizabeth Pelczar, Han Xia, Xiao Hu, Stephen Sauerbrunn, Janis Matisons

    We are pleased to announce that the 49th annual meeting of NATAS cwill be held in Rockville, MD, a beautiful city that is part of the Washington D.C. National Capital Area, on the DC metro system (allowing easy access to Washington museums and sites), and close to the National Institute of Standards and Technology (NIST), National Institutes of Health (NIH), Naval Research Laboratory (NRL), Army Research Laboratory (ARL), Johns Hopkins University Applied Physics Laboratory (JHU-APL), Naval Surface Warfare Center (NSWC), Georgetown University, George Washington University, George Mason University, and the University of Maryland. The North American Thermal Analysis Society is a venerable organization that offers scientists and practitioners the opportunity to explore the frontiers of thermal analysis, rheology, and materials characterization. The NATAS meeting always features new developments in the science of thermal analysis as well as applications of these techniques in a wide variety of fields. The meeting includes exhibits from vendors allowing for personalized attention and connecting with providers of instrumentation and software related to thermal analysis. The Society appreciates the financial support of the following contributing sponsors this year: NIST, Mettler-Toledo, TA Instruments, SETARAM, Anton Paar USA, MDPI AG, TAFDV, and QΔT Lab. Exhibitors include AKTS SA, Anton Paar USA, Mettler-Toledo, McCrone Microscopes & Accessories, NETZSCH Instruments North America, TA Instruments, and Thermtest, Inc.


  • Open Access

    Crystallize It before It Diffuses: Kinetic Stabilization of Thin-Film Phosphorus-Rich Semiconductor CuP2

    by Andrea Crovetto, Danny Kojda, Feng Yi, Karen N. Heinselman, David A. LaVan, Klaus Habicht, Thomas Unold, Andriy Zakutayev

    Numerous phosphorus-rich metal phosphides containing both P-P bonds and metal-P bonds are known from the solid-state chemistry literature. A method to grow these materials in thin-film form would be desirable, as thin films are required in many applications and they are an ideal platform for high-throughput studies. In addition, the high density and smooth surfaces achievable in thin films are a significant advantage for characterization of transport and optical properties. Despite these benefits, there is hardly any published work on even the simplest binary phosphorus-rich phosphide films. Here, we demonstrate growth of single-phase CuP2 films by a two-step process involving reactive sputtering of amorphous CuP2+x and rapid annealing in an inert atmosphere. At the crystallization temperature, CuP2 is thermodynamically unstable with respect to Cu3P and P-4. However, CuP2 can be stabilized if the amorphous precursors are mixed on the atomic scale and are sufficiently close to the desired composition (neither too P poor nor too P rich). Fast formation of polycrystalline CuP2, combined with a short annealing time, makes it possible to bypass the diffusion processes responsible for decomposition. We find that thin-film CuP2 is a 1.5 eV band gap semiconductor with interesting properties, such as a high optical absorption coefficient (above 10(5) cm(-1)), low thermal conductivity (1.1 W/(K m)), and composition-insensitive electrical conductivity (around 1 S/cm). We anticipate that our processing route can be extended to other phosphorus-rich phosphides that are still awaiting thin-film synthesis and will lead to a more complete understanding of these materials and of their potential applications.


  • Growth and Decomposition of Pt Surface Oxides

    by Feng Yi, Shane Q. Arlington, Justin Gorham, William Osborn, Ethan J. Crumlin, Slavomir Nemsak, David A. LaVan

    The formation and thermal stability of Pt surface oxides on a Pt thin film were studied in situ using ambient-pressure X-ray photoelectron spectroscopy. At an oxygen pressure of 73 Pa (550 mTorr), the surface Pt oxide was gradually formed, evidenced by the O 1s peak at 529.5 eV as the Pt film was heated. The Pt oxide peak reached a maximum between 217 and 317 °C and then decreased as the sample temperature was further increased. A similar response was seen on cooling from 480 to 23 °C; the intensity of the Pt oxide peak first increased and then decreased. The remaining Pt surface oxides partially decomposed during ultra-high-vacuum (UHV) pumping and completely decomposed during heating in UHV, which highlights the challenge of characterizing these surfaces with UHV instruments. These results have important implications for the understanding of the surface states of platinum films in different environments and the roles of different catalytic mechanisms.


  • Crystallization kinetics and thermodynamics of an Ag–In–Sb–Te phase change material using complementary in situ microscopic techniques

    by Isak McGieson, Victoriea L. Bird, Christopher M. Barr, Khalid Hattar, Bryan W. Reed, Joseph T. McKeown, Feng Yi, David A. LaVan, M. K. Santala


  • Practical Guide to the Design, Fabrication, and Calibration of NIST Nanocalorimeters

    by Feng Yi, Michael D. Grapes, David A. LaVan

    We report here on the design, fabrication, and calibration of nanocalorimeter sensors used in the National Institute of Standards and Technology (NIST) Nanocalorimetry Measurements Project. These small-scale thermal analysis instruments are produced using silicon microfabrication approaches. A single platinum line serves as both the heater and temperature sensor, and it is made from a 500 μm wide, 100 nm thick platinum trace, suspended on a 100 nm thick silicon nitride membrane for thermal isolation. Supplemental materials to this article (available online) include drawing files and LabVIEW code used in the fabrication and calibration process.


  • Nanocalorimetry: Exploring materials faster and smaller

    by Feng Yi, David A. LaVan

    This review explores the development of microchip-based nanocalorimeters for small scale and high rate thermal measurements. Nanocalorimetry is a growing field of importance given the ability to investigate the thermal behavior of thin films and nanomaterials. It can reveal how thermal properties scale with size and provide direct measurements of high rate and multistep reactions, nucleation in complex environments, and surface effects, even on samples below a monolayer.