Nadja Nijenhuis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nadja Nijenhuis has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Brian Derby
Department of Materials, University of Manchester, Oxford Road, Manchester M13 9PL, U.K.
1 shared publication - Christoph Ballestrem
Wellcome Trust Centre for Cell-Matrix Research, University of Manchester, Manchester, UK
1 shared publication - Lilli Murphy
School of Materials, The University of Manchester, Manchester, UK
1 shared publication - Michael J. Sherratt
Division of Cell Matrix Biology and Regenerative Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
1 shared publication - Rachel Elizabeth Beatrice Watson
Centre for Dermatology Research Salford Royal NHS Foundation Trust, Manchester Academic Health Science Centre, The University of Manchester Manchester UK
1 shared publication - Riaz Akhtar
Department of Materials, Design and Manufacturing Engineering, School of Engineering, University of Liverpool, United Kingdom
1 shared publication
Latest Publications
- 26 April 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 59 (4) , 610-620
Multi-layer phase analysis: quantifying the elastic properties of soft tissues and live cells with ultra-high-frequency scanning acoustic microscopy
Scanning acoustic microscopy is potentially a powerful tool for characterizing the elastic properties of soft biological tissues and cells. In this paper, we present a method, multi-layer phase analysis (MLPA), which can be used to extract local speed of sound values, for both thin tissue sections mounted on glass slides and cultured cells grown on cell culture plastic, with a resolution close to 1 μm. The method exploits the phase information that is preserved in the interference between the acoustic wave reflected from the substrate surface and internal reflections from the acoustic lens. In practice, a stack of acoustic images are captured beginning with the acoustic focal point 4 μm above the substrate surface and moving down in 0.1-μm increments. Scanning parameters, such as acoustic wave frequency and gate position, were adjusted to obtain optimal phase and lateral resolution. The data were processed offline to extract the phase information with the contribution of any inclination in the substrate removed before the calculation of sound speed. Here, we apply this approach to both skin sections and fibroblast cells, and compare our data with the V(f) (voltage versus frequency) method that has previously been used for characterization of soft tissues and cells. Compared with the V(f) method, the MPLA method not only reduces signal noise but can be implemented without making a priori assumptions with regards to tissue or cell parameters.
- 26 April 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 59 (4) , 610-620
Multi-layer phase analysis: quantifying the elastic properties of soft tissues and live cells with ultra-high-frequency scanning acoustic microscopy
Scanning acoustic microscopy is potentially a powerful tool for characterizing the elastic properties of soft biological tissues and cells. In this paper, we present a method, multi-layer phase analysis (MLPA), which can be used to extract local speed of sound values, for both thin tissue sections mounted on glass slides and cultured cells grown on cell culture plastic, with a resolution close to 1 μm. The method exploits the phase information that is preserved in the interference between the acoustic wave reflected from the substrate surface and internal reflections from the acoustic lens. In practice, a stack of acoustic images are captured beginning with the acoustic focal point 4 μm above the substrate surface and moving down in 0.1-μm increments. Scanning parameters, such as acoustic wave frequency and gate position, were adjusted to obtain optimal phase and lateral resolution. The data were processed offline to extract the phase information with the contribution of any inclination in the substrate removed before the calculation of sound speed. Here, we apply this approach to both skin sections and fibroblast cells, and compare our data with the V(f) (voltage versus frequency) method that has previously been used for characterization of soft tissues and cells. Compared with the V(f) method, the MPLA method not only reduces signal noise but can be implemented without making a priori assumptions with regards to tissue or cell parameters.